ADS131M08IPBSR - 24-Bit 8-Ch 32kSPS Delta-Sigma ADC | TI
부품 번호: ADS131M08IPBSR ✓ 활성| 수량 | 단가 | 합계 |
|---|---|---|
| 1 | $9.25 | $9.25 |
| 10 | $8.55 | $85.50 |
| 100 | $7.9 | $790.00 |
| 500 | $7.15 | $3,575.00 |
| 1,000 | $6.6 | $6,600.00 |
ADS131M08IPBSR 개요
A simultaneous-sampling delta-sigma ADC is a precision data-converter architecture in which every channel is digitized at the same instant by its own ΔΣ modulator, eliminating the skew and phase error inherent to multiplexed ADCs. Within the signal-chain hierarchy (sensor front end -> precision ADC -> digital controller), simultaneous sampling is essential for power metrology, where voltage and current channels must be phase-aligned to compute real power, power factor, and harmonic content accurately.
Key features include full 24-bit resolution, per-channel oversampling with programmable data rates up to 32 kSPS, wide dynamic range, and low power operation. TI designed the family with energy-measurement-specific features such as a dedicated CRC on the serial interface for communication integrity, direct interfacing to resistor-divider networks and current transformers or Rogowski-coil front ends, and synchronized clocking across multiple devices for polyphase metering.
Architecturally, each of the eight channels integrates its own ΔΣ modulator and digital decimation filter, allowing all eight inputs to be sampled at exactly the same moment. This removes interchannel phase mismatch, a critical requirement for three-phase energy metering where per-phase voltage-current pairing must remain phase-accurate across the entire measurement bandwidth.
Typical applications include single- and polyphase electricity meters, power-quality analyzers, circuit breakers and protective relays, solar string inverters, and precision power metrology in industrial instrumentation. The wide dynamic range supports shunt- and CT-based current sensing without front-end gain stages.
When designing with the ADS131M08IPBSR, provide a clean analog supply, synchronize the SPI host clocking to the ADC frame timing, and account for anti-alias filtering ahead of the modulator inputs at the selected OSR and data rate.
This page synthesizes distributor pricing, drop-in alternatives within the ADS131M family, application guidance, and design notes not found in the manufacturer datasheet.
드롭인 대체품: ADS131M08IPBSR — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: ADS131M08IPBSR (동일 폼 팩터 및 풋프린트) — 차이점: Interface, Package, Number of Channels, Sampling Rate, Architecture.
빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:
ADS131M08QPBSRQ1
✅ 드롭인✓ 재고 있음
가격 문의
데이터시트 보기 →ADS131M06IPBSR
✅ 드롭인 ⚠️ 사양 미검증📋 참조 대체품 (카탈로그에 없음)
ADS131M04IPBSR
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
ADS131M08IPBSR 최대 정격 & 전기적 특성
| 분해능 | 24 bit |
| Number of Channels | 8 |
| 샘플링 속도 | 32 kSPS |
| Architecture | Delta-Sigma (ΔΣ), simultaneous sampling |
| 인터페이스 | SPI (serial) |
| 패키지 | 32-TQFP (PBS), 5x5 mm |
| 동작 온도 범위 | -40C to +125C |
| 실장 유형 | Surface Mount |
| MSL 레벨 | 2 (260C, 1 year) |
| RoHS 상태 | Compliant |
| Packaging | Tape & Reel (R suffix) |
| 카테고리 | Analog to Digital Converters - ADC |
| REACH Status | unknown |
ADS131M08IPBSR 32-tqfp (pbs), 5x5 mm 핀 구성 가이드
ADS131M08IPBSR(32-tqfp (pbs), 5x5 mm 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.
다음에 대한 상세 핀아웃 데이터 없음: ADS131M08IPBSR.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
ADS131M08IPBSR 적합 용도: 6 애플리케이션s: Polyphase Energy Metering, Circuit Breakers and Protective Relays, Solar String Inverters and PV Monitoring, Power Quality Analyzers, Motor Drive and Servo Current Sensing, Battery Management and EV Charging Stations.
Polyphase Energy Metering
The ADS131M08IPBSR was purpose-built by TI for energy metering, and its eight simultaneous 24-bit channels map directly onto a three-phase meter: three voltage channels via resistor dividers, three current channels via CTs or shunts, plus neutral current and an auxiliary input. Because all eight channels are digitized by independent ΔΣ modulators at the same instant, interchannel phase error is eliminated - essential for accurate real and reactive power computation across 50/60 Hz fundamentals and their harmonics. The 32-kSPS maximum data rate provides ample oversampling margin, and the CRC-protected SPI link safeguards revenue-grade data integrity in the final meter product.
추천
Circuit Breakers and Protective Relays
In circuit-breaker and protective-relay electronics, current and voltage channels must be sampled simultaneously so that protection algorithms (overcurrent, differential, power-direction detection) can act on phase-accurate data. The ADS131M08IPBSR provides eight simultaneous 24-bit channels at up to 32 kSPS, giving relay firmware high-resolution waveforms with no channel-to-channel skew. Its wide dynamic range accommodates both the small quiescent-signal regime and the large fault transients typical of breaker sensing, and the CRC on the serial interface adds a communication integrity check consistent with protection-equipment reliability expectations. The -40C to +125C operating range supports harsh substation and panel environments.
추천
Solar String Inverters and PV Monitoring
Grid-tied solar inverters require phase-aligned sampling of PV-side and grid-side voltages and currents to implement MPPT, anti-islanding, and grid power-quality compliance. The ADS131M08IPBSR's eight simultaneous channels capture DC input, AC output voltage, and output current waveforms without multiplexer skew, while 24-bit resolution resolves the small ripple components used for MPPT decisions. The direct resistor-divider interface for voltage channels and CT/Rogowski support for current channels reduces front-end complexity and cost. The TI reference-design ecosystem also documents pairing this ADC with C2000 MCUs for precise bidirectional power-stage control in inverter topologies.
추천
Power Quality Analyzers
Power-quality analyzers measure harmonics, flicker, sags, and swells, which demands simultaneous, high-resolution capture of all phases. The ADS131M08IPBSR samples eight channels at the same instant with 24-bit resolution and up to 32-kSPS output rate, providing the bandwidth to characterize harmonics well beyond the 40th order of a 50/60 Hz fundamental while maintaining channel phase alignment for direction and power-factor calculations. Its programmable oversampling lets the analyzer trade bandwidth against noise floor per IEC-style measurement profiles, and the energy-metering-specific feature set (CRC-checked SPI, direct divider interfacing) simplifies the signal chain in portable and panel-mounted PQ instruments.
추천
Motor Drive and Servo Current Sensing
Precision motor-control systems benefit from simultaneously sampled phase currents, because torque calculations and field-oriented control assume instantaneous phase alignment. A TI reference design demonstrates exactly this topology: a C2000 MCU controlling a bidirectional interleaved buck power stage with the ADS131M08 providing precision current and voltage feedback. In a three-phase servo drive, three of the eight channels capture motor phase currents via shunts while others monitor DC bus voltage and temperature-derived signals, all sampled with zero skew. The 24-bit resolution enables low-shunt-value sensing with minimal power loss, improving drive efficiency without sacrificing control-loop accuracy.
추천
Battery Management and EV Charging Stations
DC fast-charging stations and battery-test systems need accurate, phase-consistent measurement of voltage and current to compute delivered energy within billing-grade accuracy. The ADS131M08IPBSR digitizes up to eight sense points simultaneously at 24-bit resolution, letting one device cover multiple charging ports or a battery pack's current shunt, bus voltage, and auxiliary channels without multiplexing artifacts. Its -40C to +125C temperature range suits outdoor EVSE enclosures, and the CRC-protected SPI interface maintains data integrity across the isolation barrier when combined with a digital isolator. For automotive-qualified deployments, the pin-compatible ADS131M08QPBSRQ1 variant applies directly.
추천
추천 제품 요약
엔지니어링 참조 데이터: ADS131M08IPBSR — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | ADS131M08QPBSRQ1 | ADS131M06IPBSR | ADS131M04IPBSR | AD7768-4 |
|---|---|---|---|---|---|
| Package | 32-TQFP (PBS), 5x5 mm | 32-TQFP (PBS), 5x5 mm - same | 32-TQFP (PBS), 5x5 mm - same | 32-TQFP (PBS), 5x5 mm - same | Different package/pinout - not drop-in |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices |
| Resolution | 24 bit | 24 bit | 24 bit | 24 bit | 24 bit |
| Channels | 8 simultaneous | 8 simultaneous | 6 simultaneous | 4 simultaneous | 4 simultaneous |
| Max Sample Rate | 32 kSPS | 32 kSPS | 32 kSPS | 32 kSPS | 256 kSPS |
| Interface | SPI with CRC | SPI with CRC | SPI with CRC | SPI with CRC | SPI |
주요 차별점
- Eight simultaneous channels in one package (vs ADS131M04IPBSR)
- Energy-metering-specific feature set (vs AD7768-4)
- Metrology bandwidth efficiency (vs AD7768-4)
설계 노트
Provide clean, well-decoupled analog and digital supplies and a low-jitter master clock - delta-sigma noise performance depends directly on clock quality and supply ripple. Place 100 nF ceramic decoupling capacitors at each supply pin as close to the device as possible, with bulk capacitance nearby. Separate the analog ground region under the TQFP from the SPI digital return path, joining them at a single point to keep digital switching currents out of the analog front end.
Front-end conditioning determines achievable accuracy: use precision resistor dividers for voltage channels sized for power dissipation and ratio drift, and burden or sense networks matched per channel for CT inputs. Because channels sample simultaneously, mismatch between channel front ends shows up directly as gain/phase error in power calculations - use 0.1% or better resistors for metrology-grade accuracy. Anti-alias filtering ahead of the modulator inputs should be selected for the chosen oversampling ratio and data rate.
Frame timing on the SPI interface is fixed by the ADC: the host must read conversion data within the defined frame window or data is lost - do not assume arbitrary SPI transaction timing. When synchronizing multiple ADS131M08 devices for polyphase systems, route SYNC and clock lines with matched lengths. For handling, note MSL 2 rating (260C, 1 year floor-life) - reflow-baked or sealed storage is required if floor life is exceeded.
규정 준수 정보
RoHS compliant per distributor compliance data (PartGenie: RoHS Compliant, MSL Level 2-260C-1 YEAR). Not AEC-Q100 qualified - use ADS131M08QPBSRQ1 for automotive. REACH and conflict-minerals status not stated in provided data.