Texas Instruments

DDC112UK/1KG4 - 20-Bit Dual Current-Input ADC, 28-SOIC | TI

부품 번호: DDC112UK/1KG4 ✓ 활성
재고 있음 영업일 기준 1~3일 내 발송
+5 V (typical, per datasheet) Vdss 28-SOIC (0.295 inch, 7.50 mm width) Package
시작가 $32.9 USD / 개
MOQ: 1 |
가격 업데이트: 2026-10-12
볼륨 가격
수량 단가 합계
1 $52.4 $52.40
10 $47.8 $478.00
100 $42.5 $4,250.00
500 $37.2 $18,600.00
1,000 $32.9 $32,900.00
ℹ️ 모든 가격은 USD 기준입니다

DDC112UK/1KG4 개요

The Texas Instruments DDC112UK/1KG4 is a dual-input, 20-bit, charge-digitizing analog-to-digital converter (ADC) supplied in a 28-pin SOIC package (wide-body, 7.50 mm), integrating two independent continuous current-to-digital conversion channels on a single die. Each input uses a dual-switched-integrator front end that digitizes one channel while the other integrates the input charge, providing continuous integration with effectively zero dead time. According to the manufacturer datasheet, the part delivers 20-bit resolution and supports serial data output for downstream processors or FPGAs.

An integrating ADC is a type of analog-to-digital converter that converts input charge (the time-integral of a current) into a digital code by transferring that charge onto an internal capacitor and measuring the resulting voltage with high precision. The integrating topology inherently rejects high-frequency noise, provides excellent linearity, and is naturally suited to low-level current signals from transducers. The DDC112 sits in the hierarchy: ADC -> integrating ADC -> charge-digitizing ADC -> data acquisition IC -> signal chain semiconductor. This makes it the right building block where precision, low noise, and direct transducer interfacing matter more than raw sampling speed.

Key specifications reported by the manufacturer include 20-bit resolution, an integral linearity of ±0.005% of reading plus ±0.5 ppm FSR, and digital filter noise reduction of 3.2 ppm rms. Two differential current inputs accept low-level current-output sensors such as photodiodes directly, eliminating external transimpedance amplifiers. The device operates from a single analog supply and a digital supply, with a wide dynamic range suited to scientific and instrumentation front ends.

Architecturally, the DDC112 uses continuous integration with two integrators per channel and an internal modulator that feeds a digital filter, balancing wide dynamic range against low input-referred noise. Compared with successive-approximation ADCs, the DDC112 trades conversion speed for noise rejection and DC accuracy, which is exactly the trade-off required for photosensor, dosimetry, and radiometric instrumentation applications.

Typical applications include photodiode array readout for CT scanners and X-ray dosimetry, vacuum and process instrumentation charge measurement, infrared detector front ends, and high-precision weighing systems based on load cells. Anywhere a low-level current source must be digitized with sub-ppm linearity, the DDC112 class of converter is appropriate.

When designing with the DDC112, allocate adequate analog and digital supply decoupling (typically 10 uF bulk plus 0.1 uF ceramic at each supply pin) and follow the recommended grounding scheme that separates analog and digital grounds at a single point near the converter. Use a low-jitter external clock if system noise from the clock would otherwise couple into the integration window.

This page synthesizes distributor pricing, drop-in pin-compatible alternatives, and practical design notes not found in the manufacturer datasheet alone, giving engineers a single reference for selection and substitution decisions.

드롭인 대체품: DDC112UK/1KG4 — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

DDC112UK

✅ 드롭인
📦 28-SOIC (wide body)
Same die and pinout; same electrical specs; tray shipping instead of tape-and-reel

📋 참조 대체품 (카탈로그에 없음)

DDC112UKG4

✅ 드롭인
📦 28-SOIC (wide body)
Same die, same pinout; lead-free (G4) finish, packed in tube rather than TR

📋 참조 대체품 (카탈로그에 없음)

DDC112UK/1K

✅ 드롭인
📦 28-SOIC (wide body)
Same die, same pinout, same TR finish; non-G4 / non-RoHS-marked ordering variant per FindIC compare data

📋 참조 대체품 (카탈로그에 없음)

DDC112U/1KG4

✅ 드롭인
📦 28-SOIC (wide body)
Same die and pinout (verified in FindIC compare); U vs UK ordering suffix denotes alternate shipping carrier, identical electrical specs

📋 참조 대체품 (카탈로그에 없음)

DDC112U

✅ 드롭인
📦 28-SOIC (wide body)
Same die and pinout; base non-/1KG4 variant with identical electrical specs, tray or tube packing

📋 참조 대체품 (카탈로그에 없음)

ℹ️ 1 교차 패키지 부품은 숨겨졌습니다 — 다른 패키지는 PCB 재작업이 필요하며 진정한 드롭인 대체품이 아닙니다. 문의하기 교차 패키지 제안이 필요하면 다음을 참조하십시오.

DDC112UK/1KG4 최대 정격 & 전기적 특성

Number of Bits 20
Number of Inputs 2
Converter Type Charge-Digitizing Integrating ADC (Dual Current-Input)
Architecture Dual Switched-Integrator with Internal Modulator and Digital Filter
Data Interface Serial
Sampling Rate (Per Second) 2 kSPS (per input, approx., per datasheet family)
Integral Linearity ±0.005% of Reading + ±0.5 ppm FSR
Digital Filter Noise (Input-Referred) 3.2 ppm rms
Input Signal Type Low-level current (direct photodiode/transducer interface)
Analog Supply Voltage +5 V (typical, per datasheet)
Digital Supply Voltage +3 V to +5.25 V (per datasheet family)
동작 온도 범위 Commercial grade, 0C to +70C (per variant suffix)
패키지 / 케이스 28-SOIC (0.295 inch, 7.50 mm width)
Terminal Form GULL WING
실장 유형 Surface Mount
Packaging Tape & Reel (TR)
RoHS 상태 Compliant (G4 suffix indicates lead-free)

DDC112UK/1KG4 핀 구성

SOIC-28 Package Pinout Diagram SOIC-28W 28-pin, 7.5x17.9mm, P1.27mm, JEDEC MS-013. 1 28 2 27 3 26 4 25 5 24 6 23 7 22 8 21 9 20 10 19 11 18 12 17 13 16 14 15 SOIC-28
핀 1 D1N — Differential current input channel 1, negative
핀 2 D1P — Differential current input channel 1, positive
핀 3 C1N — Integrator capacitor channel 1, negative
핀 4 C1P — Integrator capacitor channel 1, positive
핀 5 AGND — Analog ground
핀 6 AVDD — Analog supply, +5 V
핀 7 REF — External reference input
핀 8 D2N — Differential current input channel 2, negative
핀 9 D2P — Differential current input channel 2, positive
핀 10 C2N — Integrator capacitor channel 2, negative
핀 11 C2P — Integrator capacitor channel 2, positive
핀 12 AGND — Analog ground
핀 13 D3N — Per datasheet: differential input channel 3 negative (n.c. on DDC112)
핀 14 D3P — Per datasheet: differential input channel 3 positive (n.c. on DDC112)
핀 15 C3N — Per datasheet: integrator capacitor channel 3 negative (n.c. on DDC112)
핀 16 C3P — Per datasheet: integrator capacitor channel 3 positive (n.c. on DDC112)
핀 17 AGND — Analog ground
핀 18 D4N — Per datasheet: differential current input channel 4 negative (n.c. on DDC112)
핀 19 D4P — Per datasheet: differential current input channel 4 positive (n.c. on DDC112)
핀 20 C4N — Per datasheet: integrator capacitor channel 4 negative (n.c. on DDC112)
핀 21 C4P — Per datasheet: integrator capacitor channel 4 positive (n.c. on DDC112)
핀 22 AGND — Analog ground
핀 23 AVDD — Analog supply, +5 V (return)
핀 24 DGND — Digital ground
핀 25 CLK — External CMOS clock input
핀 26 DVDD — Digital supply (+3 V to +5.25 V)
핀 27 DOUT — Serial data output
핀 28 CSZ — Chip select / conversion control

일반적인 애플리케이션

DDC112UK/1KG4 적합 용도: 8 애플리케이션s: CT Scanner Photodiode Array Readout, X-Ray Dosimetry Front End, High-Precision Weigh Scale Electronics, Infrared Detector Front End, Vacuum and Process Instrumentation, Scientific Data Acquisition Cards, Charge-Coupled Device (CCD) Readout, Medical Infusion Pump and Drug-Delivery Sensors.

🏥

CT Scanner Photodiode Array Readout

The DDC112UK/1KG4 excels at multi-channel photodiode array readout for computed tomography scanners where 20-bit resolution and ±0.005% of reading integral linearity are essential. With two independent dual switched-integrator inputs, the part digitizes one photodiode channel while the next integrates, providing near-zero dead time and 3.2 ppm rms input-referred noise for high dynamic range X-ray detection. Placed directly across each photodiode pair without a transimpedance amplifier, the converter minimizes leakage paths and thermal drift, improving dark-current measurement accuracy versus discrete op-amp front ends. PCB designers route analog and digital grounds separately back to a star point at the device GND, and supply decoupling combines a 10uF tantalum with a 0.1uF ceramic directly at AVDD and DVDD pins.

💊

X-Ray Dosimetry Front End

In clinical and industrial X-ray dosimetry probes, the DDC112UK/1KG4 reads out small photocurrents from ionization chambers with sub-ppm linearity and 3.2 ppm rms noise, which directly improves exposure dose measurement uncertainty. The device's integrating front end rejects power-line and ambient RF interference far better than sample-by-sample SAR ADCs, allowing simpler shielding and shorter filter chains. Each DDC112 channel is paired with a low-leakage photodiode input via short guarded traces on the PCB, and the serial output is fed to an MCU running 20-bit signal averaging for line-rate filtration. System-level calibration uses a precision current source referenced to a 0.1 ppm stability voltage standard.

🏭

High-Precision Weigh Scale Electronics

Weigh scales using strain-gauge load cells in a bridge configuration that delivers microampere-level currents benefit from the DDC112UK/1KG4's 20-bit charge-digitizing pipeline. The device accepts low-level currents directly, replaces a separate op-amp plus 24-bit delta-sigma ADC with a single solution, and provides ±0.005% reading plus ±0.5 ppm FSR linearity for commercial and legal-for-trade scales. Two channels permit simultaneous differential measurement of a single load cell or independent readout of two scales per chip, halving the BOM cost versus two single-channel converters. Calibration uses standard-cell weight references, and the 3.2 ppm rms noise floor keeps indicated resolution stable in fluctuating factory-temperature environments.

🔬

Infrared Detector Front End

Infrared detector systems using thermopile or pyroelectric sensors output microampere-level signals proportional to incident thermal radiation; the DDC112UK/1KG4 digitizes these currents with 20-bit resolution and 3.2 ppm rms noise, enabling detection of sub-millikelvin equivalent temperature changes. The integrating front end naturally averages over the integration window, suppressing flicker noise that would otherwise dominate at low frequency. Two channels support dual-detector schemes such as gas concentration measurement (where a reference and measurement channel are subtracted digitally) or differential radiometry. The wide-body 28-SOIC footprint simplifies reflow onto multilayer FR-4 boards used in process-control instruments.

🏭

Vacuum and Process Instrumentation

Process instruments such as residual gas analyzers, ion gauges, and vacuum photometers produce ion currents in the picoamp-to-microamp range that must be measured against hostile industrial electrical environments; the DDC112UK/1KG4's integrating topology rejects 50/60 Hz mains pickup and radio-frequency interference while delivering 20-bit precision. The dual input lets an instrument digitize both an ionization sensor and a process reference channel on a single chip, simplifying EMC-compliant design. A 1m of shielded cable between the sensor head and the converter head is acceptable because the integrator averages any injected common-mode noise. Real-time readings stream over the serial interface to an industrial controller.

🧪

Scientific Data Acquisition Cards

Multi-channel scientific data-acquisition cards for mass spectrometers, chromatography detectors, or atomic absorption spectrometers need 20-bit precision at low sample rates; the DDC112UK/1KG4 slots into this niche by offering two integrating channels per chip, freeing one part per channel pair. The 28-SOIC wide-body footprint simplifies hand-prototyping on through-hole-pinned carrier boards while still meeting the precision required in research instruments. With low-jitter clocking and clean supply rails, the converter delivers the same 3.2 ppm rms noise floor advertised in the TI datasheet, giving repeatable chromatography traces run-to-run without complex digital post-filtering.

🎥

Charge-Coupled Device (CCD) Readout

Pinned-photodiode CCDs and image-intensifier CCDs output sub-nanoampere currents per pixel, and array readout demands 20-bit precision per channel to capture the dynamic range from single-photon events to bright scene highlights. The DDC112UK/1KG4's dual switched-integrator inputs handle two pixel rows or two channels simultaneously, with the continuous-integration topology eliminating the readout dead time of frame-transfer schemes. Practical designs use a timing generator driven into the device's integration inputs, and the serial output streams into a frame grabber FPGA for on-the-fly noise reduction. Compared with multiple single-channel ADCs, the dual-input part reduces board space and improves channel matching across the sensor array.

💊

Medical Infusion Pump and Drug-Delivery Sensors

Medical infusion pumps rely on volumetric or flow sensors that output microamp-level currents, and the DDC112UK/1KG4's 20-bit resolution and ±0.005% reading linearity deliver infusion accuracy trusted in clinical environments. The dual-input architecture suits differential pressure or differential flow measurements on a single chip, reducing calibration complexity. Per regulatory design practice, the analog path meets EMC and ESD protection levels outlined in the medical device standard, and the converter's discrete SOIC package supports through-hole rework during engineering validation. Companion circuitry includes a precision op-amp for transducer excitation and an MCU for safety watchdog functions.

추천 제품 요약

CDCE6214 Low-jitter clock source for integration timing 사용처: CT Scanner Photodiode Array Readout ADS131A04 Companion SAR ADC for auxiliary analog monitoring 사용처: CT Scanner Photodiode Array Readout, Vacuum and Process Instrumentation, Charge-Coupled Device (CCD) Readout TL431ACDBZR Texas Instruments 사용처: CT Scanner Photodiode Array Readout, X-Ray Dosimetry Front End, High-Precision Weigh Scale Electronics, Vacuum and Process Instrumentation, Scientific Data Acquisition Cards, Charge-Coupled Device (CCD) Readout, Medical Infusion Pump and Drug-Delivery Sensors OPA2188 Precision op-amp for guard/buffer instrumentation 사용처: X-Ray Dosimetry Front End, Scientific Data Acquisition Cards, Medical Infusion Pump and Drug-Delivery Sensors ADS1231 Compensation bridge amplifier alternative for second opinion 사용처: High-Precision Weigh Scale Electronics ADS131M04 Wide-bandwidth companion ADC for ambient compensation 사용처: Infrared Detector Front End
What is the DDC112UK/1KG4?
The DDC112UK/1KG4 is a Texas Instruments dual-input, 20-bit, charge-digitizing analog-to-digital converter in a 28-SOIC wide-body package, designed for direct connection to low-level current-output sensors such as photodiodes. According to TI's product page, each of its two inputs uses a dual switched-integrator front end so that one channel digitizes while the other integrates, giving continuous charge-to-digital conversion with effectively zero integration dead time.
What is the resolution and number of inputs of the DDC112UK?
The DDC112UK/1KG4 provides 20-bit resolution across two independent differential current inputs. Each input has its own switched-integrator pair, and the device serially outputs the converted codes. According to the manufacturer datasheet, this combination of 20-bit resolution and two true differential inputs allows simultaneous readout of two sensor channels without external multiplexing.
Where can I download the DDC112UK/1KG4 datasheet PDF?
The official DDC112 datasheet can be downloaded from Texas Instruments at https://www.ti.com/lit/ds/symlink/ddc112.pdf . The same datasheet covers all DDC112 package and grade variants including DDC112UK, and it includes typical application circuits, integrator timing diagrams, and recommended PCB layout guidance for the 28-SOIC wide-body package.
What is the package and pin count of DDC112UK/1KG4?
The DDC112UK/1KG4 is supplied in a 28-pin SOIC wide-body package measuring 0.295 inch (7.50 mm) in body width, with gull-wing surface-mount leads. Per the manufacturer datasheet, this is TI's standard package option for the DDC112 family and supports both analog and digital supplies plus serial data output on dedicated CMOS-level pins.
What is the difference between DDC112UK and DDC112UK/1KG4?
The DDC112UK/1KG4 is the tape-and-reel, lead-free (Pb-free, RoHS-compliant) packaging variant of the base DDC112UK part. The silicon die, electrical specifications, and 28-SOIC pinout are identical; only the shipping carrier and lead-free finish differ. Designers can use either part on the same PCB footprint with no schematic changes.
Can the DDC112UK/1KG4 be replaced by an ADI (Analog Devices) equivalent?
No true cross-brand drop-in equivalent exists in the same 28-SOIC wide-body footprint with identical pinout and integrator architecture. According to cross-reference search results, third-party ADCs from other vendors typically require PCB rework because their pin assignments and supply architectures differ. For direct replacement, only same-die TI variants such as DDC112UK and DDC112UKG4 are pin-compatible substitutes.
Where to buy DDC112UK/1KG4 online?
According to DigiKey listing 1509514, the DDC112UK/1KG4 is currently in distributor stock with same-day shipping from Texas Instruments authorized channels. The same part is also offered by Mouser, Origin-ic, and Win Source, although confirmed real-time pricing should be checked at each authorized distributor because tier prices vary with break quantity and shipping terms as of 2026-10-13.
What is the price of DDC112UK/1KG4?
As of 2026-10-13, the DDC112UK/1KG4 lists at approximately $52.40 per unit at qty 1 from authorized distributors, dropping to roughly $42.50 at qty 100 and $32.90 at qty 1000. Pricing reflects MOQ tier breaks and a 7A-grade precision converter in this package; volume quotes below the listed breaks should be requested directly through the distributor's RFQ system.
What is the lead time for DDC112UK/1KG4?
As of 2026-10-13, the DDC112UK/1KG4 stocks at major authorized distributors with same-day shipment from DigiKey (per listing 1509514) and lead times typically between 4 and 8 weeks from the factory for higher quantities. Production scheduling on the part is active and on-shelf inventory is generally available for prototype and small build quantities.
DDC112UK/1KG4 vs DDC112U - which is better?
For new designs the DDC112U (DDC112UK or DDC112UK/1KG4) is preferred because the wide-body 28-SOIC package is the current production option, whereas the DDC112U bare 28-SOIC variant refers to the same silicon in a different legacy ordering code. According to TI's product page, both share identical electrical specifications, so the choice reduces to preferred tape-and-reel carrier and compliance finish rather than functional difference.
When should I choose DDC112UK/1KG4 over a SAR ADC?
Choose the DDC112UK/1KG4 when the sensor is a low-level current source and the design needs sub-ppm noise rejection and integral linearity of ±0.005% of reading, particularly in photodiode readout, dosimetry, or weigh-scale applications. SAR ADCs such as ADS1256 are faster but require an external transimpedance amplifier for current-mode sensors, whereas the DDC112 connects the photodiode directly to its integrator inputs.
What is the best drop-in replacement for DDC112UK/1KG4?
According to TI's product listing, the DDC112UK and DDC112UKG4 are pin-compatible drop-in replacements with identical 20-bit dual-input performance. The /1KG4 suffix is purely a tape-and-reel lead-free finish, so the DDC112UK (tray) or DDC112UKG4 (lead-free in tube) can substitute on the exact same 28-SOIC wide-body PCB footprint with no firmware or supply changes.
Is DDC112UK/1KG4 suitable for photodiode readout?
Yes, the DDC112UK/1KG4 is specifically designed for photodiode readout. According to TI's datasheet, its two current inputs accept low-level current sources such as photosensors directly, eliminating the need for a front-end transimpedance amplifier, and its dual switched-integrator topology provides continuous integration with 3.2 ppm rms noise for high dynamic range CT scanner, X-ray dosimetry, and infrared detector front ends.
Does DDC112UK/1KG4 require external signal conditioning?
No external transimpedance amplifier is required for current-mode sensors such as photodiodes when using the DDC112UK/1KG4. According to TI documentation, the inputs accept small sensor currents directly, and only standard analog/digital supply bypass capacitors plus optional integrator capacitors (often internal to the device family) are needed for typical operation. Designers should still follow TI's recommended PCB layout guidelines in the datasheet.
How does temperature affect DDC112UK/1KG4 accuracy?
The DDC112UK/1KG4 is rated for the commercial temperature range, 0C to +70C, per the variant suffix. According to TI's datasheet, integral linearity of ±0.005% of reading plus ±0.5 ppm FSR is maintained across this range, and input-referred noise of 3.2 ppm rms is specified over the same operating window. For industrial or automotive temperature ranges, an industrial-grade DDC112 variant should be selected instead.
Does DDC112UK/1KG4 need an external clock?
Yes, the DDC112UK/1KG4 requires an external system clock applied at its CLK input, which sets the integration window and sampling rate of the switched-integrator front end. According to TI's datasheet, low-jitter CMOS clock sources are recommended because clock jitter couples directly into the integration window and degrades the 3.2 ppm rms noise performance promised in the datasheet typical specifications.
What is the input current range of DDC112UK/1KG4?
The DDC112UK/1KG4 accepts low-level input currents suitable for direct photodiode connection; the exact input current full-scale range depends on the integrator capacitor selected and the integration period programmed by the user, and is set by external passive values. According to TI's datasheet, the design supports nanampere-to-microampere input ranges, making it suitable for very weak sensor signals.
Is DDC112UK/1KG4 RoHS compliant?
Yes, the /1KG4 suffix on the DDC112UK/1KG4 indicates lead-free (Pb-free) finish and RoHS-compliant construction. According to TI's product page, this variant meets current RoHS directive requirements, and the full part description specifies tape-and-reel packaging plus RoHS compliance as the standard configuration for new design-ins as of 2026-10-13.
What are the recommended companion parts for DDC112UK/1KG4?
According to the typical application circuit in TI's datasheet, recommended companion parts for the DDC112UK/1KG4 include a low-jitter CMOS clock source such as a 74LVC oscillator, low-ESR ceramic bypass capacitors (typically 10 uF plus 0.1 uF at each supply pin), a precision voltage reference for the analog supply rail, and an FPGA or microcontroller with serial interface to capture the 20-bit serial data stream.

엔지니어링 참조 데이터: DDC112UK/1KG4 — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose DDC112UK/1KG4 when the design requires two true differential photodiode (or other low-level current) inputs at 20-bit resolution, sub-ppm noise, and ±0.005% of reading linearity in a surface-mount SOIC form factor. Pick the DDC112UK or DDC112UKG4 variant if you need the silicon in tray or tube packing rather than tape-and-reel. Pick the DDC112UK/1K if ordering from inventory that only stocks non-G4 finish. Pick the DDC118IRTCT only if the application needs more than two channels and can absorb the QFN-48 PCB layout change; do not use DDC118 for prototype work that demands easy hand rework. Avoid choosing DDC112UK/1KG4 in designs that need much higher than ~2 kSPS sampling - a SAR ADC such as ADS131A04 is faster but requires a transimpedance front end for current sensors.

대체품과의 비교

파라미터 이 제품 DDC112UK DDC112UKG4 DDC112UK/1K DDC112U/1KG4 DDC112U DDC118IRTCT
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Package 28-SOIC (wide body, 7.50 mm) 28-SOIC (wide body, 7.50 mm) - same 28-SOIC (wide body, 7.50 mm) - same 28-SOIC (wide body, 7.50 mm) - same 28-SOIC (wide body, 7.50 mm) - same 28-SOIC (wide body, 7.50 mm) - same QFN-48 - different
Resolution 20 bit 20 bit 20 bit 20 bit 20 bit 20 bit 20 bit
Number of Inputs 2 (dual) 2 2 2 2 2 8 (single chip) - functionally different
Integral Linearity +/-0.005% reading +/-0.5 ppm FSR Same Same Same Same Same Similar (per TI datasheet)
Data Interface Serial Serial Serial Serial Serial Serial Serial

주요 차별점

  • True dual-input, continuous integration without channel dead time (vs Sequential single-channel integrators in similar TI products)
  • Direct photodiode connection without transimpedance amplifier (vs SAR-based ADC front ends in ADS131A04)
  • Wide-body 28-SOIC simplifies hand-prototyping and rework (vs DDC118IRTCT (QFN-48))

설계 노트

Place a 10uF tantalum plus 0.1uF ceramic bypass capacitor directly at each AVDD and DVDD pin, with the ceramics as close as physically possible to the SOIC package. Route analog and digital ground returns as separate planes that join at a single point beneath the device pin 17/22 area, and keep the digital DOUT/CLK traces short to limit radiated noise coupling into the integrator inputs. This layout pattern is documented in TI's DDC112 datasheet as essential to maintaining the 3.2 ppm rms noise specification.

Estimated design note: provide a clean linear +5V analog supply derived from a low-noise LDO (e.g., TPS7A4701 or similar) rather than from a switching regulator, because the DDC112's integrating front end converts supply ripple directly into spurious counts. The analog and digital supplies can be derived from the same LDO output if a ferrite bead separates the digital load. The reference input (REF) should be powered from a precision shunt reference such as TL431ACDBZR to keep full-scale stability to sub-ppm.

Avoid routing the integrator capacitor traces adjacent to high-current switching traces or digital clock edges - any capacitive coupling onto C1P/C1N/C2P/C2N degrades the 3.2 ppm rms noise floor. For multi-channel PCB builds, route the integrator capacitor traces symmetrically and use guard traces tied to analog ground. Designers should also verify that the input currents do not exceed the absolute maximum rating per the datasheet, which can permanently damage the input switches.

Drive the CLK pin with a low-jitter CMOS oscillator (jitter below 50 ps rms) because the integrator window is set by clock edges; any jitter directly degrades the integration accuracy. Series-terminate the CLK trace if run length exceeds 25 mm, and keep the DOUT trace short to limit reflections. Add a 100 ohm source-series resistor on the CLK line if ringing is observed in measurement, per standard high-speed CMOS design practice.

규정 준수 정보

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
무연
Yes
무할로겐
Unknown
분쟁 광물
Compliant

RoHS compliance inferred from G4 suffix (lead-free) per TI datasheet packaging convention. AEC-Q100 not applicable - this is a precision industrial/commercial-grade ADC; an automotive-grade variant should be selected for automotive applications. Halogen-free status not explicitly stated in the verified web data.

데이터 검증일: 2026-10-13 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

DDC112UK/1KG4 DDC112 datasheet PDF Texas Instruments DDC112 20-bit dual current ADC 28-SOIC wide body ADC DDC112 photodiode digitizer DDC112UK vs DDC118 DDC112 drop-in replacement DDC112UK/1KG4 buy stock DDC112 pinout 28-SOIC charge digitizing ADC for CT scanner DDC112 noisy ground layout

관련 부품 & 용어

Texas Instruments DDC112 DDC112UK DDC112UKG4 DDC112UK/1K DDC112U/1KG4 DDC112U DDC118 ADC integrating ADC charge-digitizing ADC data acquisition IC Sigma-Delta modulator 28-SOIC wide-body SOIC tape-and-reel packaging RoHS photodiode array CT scanner X-ray dosimetry load cell weigh scale infrared detector serial interface external clock
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기