FF1200R17IP5R - 1700V 1200A PrimePACK 2 IGBT Module | Infineon
부품 번호: FF1200R17IP5R ✓ 활성| 수량 | 단가 | 합계 |
|---|---|---|
| 1 | $385 | $385.00 |
| 10 | $372 | $3,720.00 |
| 50 | $360 | $18,000.00 |
| 100 | $348 | $34,800.00 |
| 500 | $332 | $166,000.00 |
FF1200R17IP5R 개요
An IGBT module is a high-power, integrated switching subsystem that combines one or more insulated-gate bipolar transistors with anti-parallel diodes in a single, isolated package, allowing inverter and converter designers to build three-phase or half-bridge power stages with a single mechanical assembly. IGBT modules sit at the top of the power-electronics hierarchy: IGBT -> power semiconductor -> discrete semiconductor -> power electronics. The PrimePACK 2 family is targeted at medium-voltage, high-current industrial converters where conduction losses, short-circuit ruggedness, and long-term reliability under thermal cycling are the dominant design constraints.
Key features of the FF1200R17IP5R include a 1700 V collector-emitter blocking rating, 1200 A nominal collector current at Tc = 25 °C (with derating at higher Tvj), low VCE(sat) typical of TRENCHSTOP IGBT5, and a screw-type power and signal terminal layout that has become the de-facto standard for 1200 A/1700 V class inverters. The integrated NTC thermistor enables closed-loop temperature monitoring, while the EC5 diode minimizes reverse-recovery losses in hard-switched topologies. The PrimePACK 2 footprint is mechanically compatible with prior-generation PrimePACK 1 modules, simplifying upgrades.
Typical applications for the FF1200R17IP5R include high-power industrial drives, wind-power converters, solar central inverters, traction auxiliaries, and high-power UPS systems, where the module's combination of low conduction loss, high current density, and rugged thermal performance enables compact, high-efficiency converter designs in the megawatt class.
When designing with this module, ensure the dc-link bus bars use low-inductance laminated construction to stay within the module's voltage overshoot limit at 1700 V, and torque the main power screws to the manufacturer-specified value. The NTC pin must be connected to the controller's analog front end and used for both thermal protection and derating of switching frequency.
드롭인 대체품: FF1200R17IP5R — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:
FF1200R17IP5
✅ 드롭인 ⚠️ 사양 미검증📋 참조 대체품 (카탈로그에 없음)
FF1200R17IP5BPSA1
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
FF1200R17IP5PBPSA1
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
FF1200R17KE3
✅ 드롭인 ⚠️ 사양 미검증📋 참조 대체품 (카탈로그에 없음)
FF1200R17IP5R 최대 정격 & 전기적 특성
| Manufacturer | Infineon Technologies |
| 토폴로지 | Half-bridge (dual IGBT) |
| Collector-Emitter Voltage (VCES) | 1700 V |
| Nominal Collector Current (IC nom) | 1200 A |
| IGBT Technology | TRENCHSTOP IGBT5 with .XT interconnection |
| Free-Wheeling Diode | Emitter Controlled 5 (EC5) |
| Integrated NTC Thermistor | Yes |
| Operating Virtual Junction Temperature (Tvjop) | 175 °C (extended, max) |
| Package / Footprint | PrimePACK 2 chassis-mount module |
| 실장 유형 | Chassis mount, screw terminals |
| Chip Attachment | Sintered (for highest power-cycling capability) |
| Bond Wire Material | Copper (high current carrying) |
| Output Current Increase vs Prior Generation | >25% in same footprint |
| Typical Applications | Industrial drives, wind/solar converters, traction, UPS |
FF1200R17IP5R primepack 2 chassis-mount module 핀 구성 가이드
FF1200R17IP5R(primepack 2 chassis-mount module 패키지)의 핀 구성입니다. 이 전력 소자는 게이트, 드레인, 소스 단자를 갖추고 있습니다. 비편향 패키지의 경우 정확한 핀 1 방향과 풋프린트 세부 정보는 제조사 데이터시트를 참조하십시오. 일반적인 응용 분야로는 전원 공급 장치 설계, 모터 구동, 부하 스위칭이 있습니다.
다음에 대한 상세 핀아웃 데이터 없음: FF1200R17IP5R.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
Forward Bias 안전 동작 영역 (FBSOA), indicative
일반적인 애플리케이션
FF1200R17IP5R 적합 용도: 6 애플리케이션s: Industrial Motor Drives, Wind Power Converters, Solar Central Inverters, Traction Auxiliary Converters, Industrial UPS Systems, High-Power SMPS and Induction Heating.
Industrial Motor Drives
The FF1200R17IP5R is well-suited for medium-voltage industrial motor drives in the 600-1000 kW range, where its 1200 A nominal current and 1700 V VCES support 690 V AC and 980 V AC bus operation. The TRENCHSTOP IGBT5 silicon keeps VCE(sat) low, reducing conduction losses that dominate at high load, while the EC5 diode's soft recovery minimizes turn-on losses in the opposing switch during hard-switched PWM at typical 2-4 kHz switching frequencies. The PrimePACK 2 chassis-mount footprint integrates cleanly with liquid-cooled or forced-air heatsinks, and the integrated NTC enables direct baseplate temperature monitoring for derating and fault protection. Sintered chip attach and copper bond wires extend power-cycling life, which is critical in drives that undergo frequent start-stop cycles.
추천
Wind Power Converters
In wind turbine converters, the FF1200R17IP5R serves as the power-stage building block in the generator-side and grid-side inverters of 2-3 MW turbines. The module's 1700 V VCES provides ample margin for the 1100-1200 V DC-link typical of full-converter topologies, while its 1200 A rating supports the high currents seen at low generator speeds during startup. TRENCHSTOP IGBT5's low VCE(sat) reduces steady-state losses across the turbine's wide operating range, and the EC5 diode's low Qrr minimizes reverse-recovery stress during low-voltage ride-through events. The 175 °C Tvjop qualification allows derated operation at altitudes or in nacelle environments with restricted cooling, while sintered attachment and copper bonds deliver the long-term reliability demanded by 20+ year service intervals.
추천
Solar Central Inverters
Solar central inverters in the 1-2 MW class commonly use the FF1200R17IP5R for the DC-AC stage that converts 1000-1500 V DC bus to medium-voltage AC. The module's 1700 V VCES rating provides the necessary safety margin for transient over-voltages from the DC bus and grid-side disturbances, while the 1200 A current rating supports high power throughput in a compact subassembly. TRENCHSTOP IGBT5's low conduction losses translate directly into higher CEC-weighted inverter efficiency, a key metric for utility-scale PV plants. The EC5 free-wheeling diode's soft recovery reduces EMI in PWM operation, simplifying filter design. The PrimePACK 2 footprint is shared across major Tier-1 inverter platforms, enabling direct substitution with the FF1200R17IP5BPSA1 or PB-BPSA1 ordering variants without mechanical rework.
추천
Traction Auxiliary Converters
Traction auxiliary converters in locomotives and EMUs use the FF1200R17IP5R for auxiliary power supplies that feed lighting, HVAC, battery chargers, and control electronics from the 1500 V DC overhead line or 750 V DC third-rail bus. The module's 1700 V rating provides margin for the harsh voltage transients typical of traction environments, and its half-bridge topology simplifies the bidirectional boost/buck stages common in auxiliary supplies. The 175 °C Tvjop qualification supports operation in the under-car equipment compartments where ambient temperatures are high and cooling is restricted. Sintered chip attachment and copper bonds deliver the vibration tolerance and long-term reliability required by rolling stock service standards (typically EN 50155 / IEC 61373 for shock and vibration).
추천
Industrial UPS Systems
High-power industrial UPS systems in the 500 kVA to 1.5 MVA range deploy the FF1200R17IP5R as the rectifier/inverter switch in their double-conversion power stages. The 1200 A current rating supports the high peak currents seen during load-step transients and battery-mode operation, while the 1700 V VCES allows direct connection to the 690 V AC bus without additional step-up stages. The module's low VCE(sat) on TRENCHSTOP IGBT5 reduces steady-state losses in always-on UPS installations, where continuous efficiency directly translates to lower operating cost. The integrated NTC thermistor enables thermal monitoring for ambient-adaptive fan or cooling control, while the PrimePACK 2 footprint matches the standard UPS power-module mechanical interface used by leading UPS OEMs.
추천
High-Power SMPS and Induction Heating
The FF1200R17IP5R is used in high-power switched-mode power supplies and industrial induction-heating inverters where 1700 V blocking and 1200 A continuous current are required. In resonant and hard-switched SMPS topologies, the EC5 diode's soft recovery behavior reduces switching losses and EMI, while the TRENCHSTOP IGBT5's tight VCE(sat) distribution supports parallel operation of multiple modules. In induction-heating inverters operating at 10-50 kHz, the 175 °C Tvjop qualification enables sustained high-frequency switching without exceeding thermal limits. The PrimePACK 2 chassis-mount package integrates directly with water-cooled cold plates used in induction-heating cabinets, simplifying thermal management.
추천
추천 제품 요약
엔지니어링 참조 데이터: FF1200R17IP5R — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | FF1200R17IP5 | FF1200R17IP5BPSA1 | FF1200R17IP5PBPSA1 | FF1200R17KE3 |
|---|---|---|---|---|---|
| Brand | Infineon Technologies | Infineon Technologies | Infineon Technologies | Infineon Technologies | Infineon Technologies |
| Package | PrimePACK 2 | PrimePACK 2 - same | PrimePACK 2 - same | PrimePACK 2 - same | PrimePACK 2 - same |
| Topology | Half-bridge | Half-bridge | Half-bridge | Half-bridge | Half-bridge |
| VCES | 1700 V | 1700 V | 1700 V | 1700 V | 1700 V |
| IC nom | 1200 A | 1200 A | 1200 A | 1200 A | 1200 A |
| IGBT Generation | TRENCHSTOP IGBT5 with .XT | TRENCHSTOP IGBT5 with .XT | TRENCHSTOP IGBT5 with .XT | TRENCHSTOP IGBT5 with .XT | TRENCHSTOP IGBT5 with .XT (E3 = .XT variant) |
| Integrated NTC | Yes | Yes | Yes | Yes | Yes |
| Tvjop max | 175 °C | 175 °C | 175 °C | 175 °C | 175 °C |
주요 차별점
- Highest power-cycling capability in the 1700 V/1200 A PrimePACK 2 class (vs FF1200R17IP5 (base variant))
- Extended Tvjop of 175 °C vs. typical 150 °C (vs Legacy IGBT4-based PrimePACK 2 modules)
- More than 25% output current increase in same PrimePACK 2 footprint (vs Prior-generation PrimePACK 2 modules (IGBT4))
설계 노트
Use low-inductance laminated bus bars for the dc-link to keep the voltage overshoot at IGBT turn-off within the module's 1700 V VCES rating. Typical PrimePACK 2 designs target a commutation loop inductance below 30 nH; with a 1200 A di/dt of 5 kA/µs this keeps the peak overshoot under 150 V. Place the dc-link capacitors as close as physically possible to the module's power terminals and use a symmetrical bus-bar layout to minimize the differential-mode inductance between the upper and lower IGBTs of the half-bridge.
The PrimePACK 2 baseplate must be mounted to a heatsink with thermal compound applied evenly and torque applied per the Infineon datasheet (typically 5 Nm for the M6 mounting screws). The integrated NTC is intended for baseplate temperature sensing only; for accurate junction temperature estimation, use the thermal impedance curves (Zthjc and Zthch) from the datasheet and apply the loss profile of your specific switching frequency and conduction duty cycle. The 175 °C Tvjop allows short excursions above the typical 150 °C industrial limit, but continuous operation above 150 °C will accelerate power-cycling wear.
Do not exceed the gate-emitter voltage rating of ±20 V during operation; transients above this limit will damage the IGBT gate oxide. Use a gate-drive circuit that actively clamps gate spikes to within ±20 V and that pulls the gate to a defined negative voltage (typically -8 V to -15 V) during the off-state to prevent parasitic turn-on from Miller-capacitive coupling. Avoid paralleling PrimePACK 2 modules without matched gate-drive impedance; the TRENCHSTOP IGBT5 has a relatively flat VCE(sat) curve and paralleling requires careful symmetry of power-loop inductance and gate-drive timing.
Although the FF1200R17IP5R is a chassis-mount module with screw power terminals, the gate-drive auxiliary signals are routed through a dedicated signal pin header on the side of the module. Keep the gate-drive PCB or cable assembly as short as possible (typically under 100 mm) to minimize gate-loop inductance, and route the auxiliary emitter (E) trace in a tight loop with the gate (G) trace to keep the gate-drive loop inductance under 20 nH. Use twisted-pair or coaxial cabling for the NTC signal to prevent noise pickup in the high-dV/dt environment near the power terminals.
규정 준수 정보
RoHS and REACH compliance per Infineon product page. AEC-Q100 not applicable for industrial IGBT modules. Halogen-free status not explicitly stated in the verified web data and is marked as 'unknown' pending datasheet confirmation. Conflict-minerals statement available from Infineon corporate compliance.