Maxim Integrated

ICL7126IPL+ - 3.5-Digit CMOS ADC | Maxim Integrated

부품 번호: ICL7126IPL+ ✓ 활성
1 pA Id 40-pin PDIP Package
MOQ: 1 |

ICL7126IPL+ 개요

The Maxim Integrated ICL7126IPL+ is a low-power, 3.5-digit successive-approximation A/D converter with an integrated voltage reference and clock, supplied in a 40-pin PDIP package. The converter is designed for low-power measurement systems and uses a differential input architecture with a resolution of 0.05 percent. The ICL7126IPL+ is the commercial-temperature, through-hole version of the ICL7126 family, with an operating range of 0°C to 70°C.

An ADC is an interface component that converts an analog voltage into a numeric value for measurement, control, or display. The ICL7126 integrates the active circuitry required for a complete 3.5-digit measurement channel on one CMOS IC. Unlike discrete meter designs, its integrated reference, clock, and conversion system reduce component count while retaining direct measurement of slowly changing voltages.

Key features include a true differential input and reference arrangement, a guaranteed zero reading for a zero-volt input, and true polarity at zero for precise null detection. The converter also provides approximately 1 pA typical input current. Its 3.5-digit architecture supports instrumentation displays and panel-meter applications where four digits of resolution are useful while a sign indicator improves readability around the zero point.

The CMOS implementation emphasizes low operating power, making the device suitable for portable instruments and battery-operated measurement panels. Integration of the reference and clock simplifies board design by reducing the number of external timing and calibration components. Differential measurement can also reject common-mode voltage when the source and reference paths are arranged carefully, although real-world accuracy still depends on input filtering, reference quality, grounding, and analog-layout discipline.

Typical uses include digital panel meters, laboratory measurement instruments, temperature and process monitoring, portable test equipment, and low-power sensor interfaces. The 40-pin PDIP package favors through-hole assembly, repairable prototypes, and larger industrial control boards where a surface-mount footprint would offer little practical benefit.

Designers should verify the complete electrical limits and recommended operating circuit in the manufacturer datasheet before release. Pay particular attention to input and reference polarity, conversion timing, bypass-capacitor placement, and the relationship between source impedance and accuracy. A stable, low-noise reference path and short analog traces are essential for repeatable measurements.

This product page combines the manufacturer product information with package-specific identification, application guidance, verified sourcing information, and drop-in replacement analysis. It also highlights the practical advantages and limitations of the 40-pin PDIP format for engineers deciding whether the ICL7126IPL+ fits an existing measurement-instrument design.

드롭인 대체품: ICL7126IPL+ — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: ICL7126IPL+ (동일 폼 팩터 및 풋프린트) — 차이점: Power Class.

Analog Devices
Power Class: Low power
비교 대상: ICL7126IPL+ →

ICL7126CPL+

✅ 드롭인
Analog Devices
📦 40-pin PDIP
3.5-digit dual-slope analog-to-digital converter · Analog Devices Inc./Maxim Integrated · Dual-slope · 3 conversions per second · 3.5 digits · Single analog input · Monolithic CMOS integrating ADC · Yes

가격 문의

데이터시트 보기 →

TC7126IPL

✅ 드롭인
📦 40-pin PDIP
Same 40-pin PDIP footprint and 3.5-digit CMOS ADC function; internal timing, enable, and electrical-limit details must be checked before substitution

📋 참조 대체품 (카탈로그에 없음)

ICL7126IPL+ 최대 정격 & 전기적 특성

ADC Type 3.5-digit successive-approximation A/D converter
분해능 0.05 percent
Architecture CMOS monolithic analog-to-digital converter
Input Configuration True differential input and reference
Typical Input Current 1 pA
Zero-Input Reading Guaranteed zero reading on all scales
Zero Polarity True polarity at zero
Integrated Functions Voltage reference and clock
Power Class Very low power
패키지 40-pin PDIP
Terminal Count 40 terminals
실장 유형 Through-hole
Temperature Grade Commercial
동작 온도 0°C to 70°C
AEC-Q100 Qualification Not applicable

ICL7126IPL+ 40-pin pdip 핀 구성 가이드

ICL7126IPL+(40-pin pdip 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.

ICL7126IPL+의 40-pin pdip 패키지 핀아웃 다이어그램

다음에 대한 상세 핀아웃 데이터 없음: ICL7126IPL+.

다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.

일반적인 애플리케이션

ICL7126IPL+ 적합 용도: 6 애플리케이션s: Digital Panel Meters, Portable Test Instruments, Industrial Process Monitoring, Temperature Measurement Front Ends, Laboratory Voltage Meters, Sensor Signal Conditioning.

📺

Digital Panel Meters

The ICL7126IPL+ fits a digital panel meter because it integrates a 3.5-digit conversion channel, voltage reference, and clock into one CMOS device. Its 0.05-percent resolution provides adequate measurement detail for displaying pressure, level, position, temperature, and process variables. The true differential input arrangement can reject common-mode voltage when the signal and reference paths are balanced correctly. The 40-pin PDIP format also simplifies through-hole assembly and service replacement in larger meter platforms. For stable readings, keep analog traces short, use a clean reference, and confirm the required display interface and timing from the manufacturer data sheet.

🔧

Portable Test Instruments

The ICL7126IPL+ supports portable test instruments where low power and component integration are important. The converter’s approximately 1 pA typical input current reduces loading of high-impedance sources, while its integrated reference and clock reduce the external circuitry needed for a working measurement channel. A 3.5-digit display can show a sign and four decimal digits, which is useful for handheld meters and field-service probes. Designers should still budget for display current, switch resistance, supply conversion loss, and the time required to acquire the signal before conversion.

🏭

Industrial Process Monitoring

The ICL7126IPL+ is appropriate for industrial process monitoring when the required temperature range remains within its commercial 0°C-to-70°C rating. The differential input supports measurement of small signals riding on a controlled common-mode voltage, and the integrated reference and clock simplify the analog front end of a panel-mounted monitor. Its 40-pin through-hole package is especially convenient for repairable control cabinets and larger controller boards. For installations with extended temperature, vibration, electrical-noise, or long-life requirements, add appropriate protection and verify the availability of a suitably qualified product.

🌡️

Temperature Measurement Front Ends

The ICL7126IPL+ can serve as the measurement ADC in a temperature-monitoring front end when the sensor and signal path are compatible with a 3.5-digit dual-slope measurement architecture. The guaranteed zero reading on all scales improves display behavior around zero, while true polarity supports precise null or deviation measurements. A thermistor bridge, thermocouple interface, or RTD front end may require additional cold-junction, linearization, and protection circuits. Select external resistor and capacitor values from the application guidance and evaluate self-heating before assigning final measurement accuracy.

🧪

Laboratory Voltage Meters

The ICL7126IPL+ is suitable for a laboratory voltage meter or bench instrument requiring a stable low-power reading with a signed 3.5-digit display. Its integrated clock and reference reduce assembly complexity, and the differential input architecture supports careful routing of sensitive measurement and reference signals. The commercial temperature range suits controlled indoor environments. The main design priorities are guarding against leakage, maintaining a low-noise reference, separating analog and digital return currents, and calibrating gain and offset. The 40-pin PDIP package remains practical for prototypes and medium-production through-hole assemblies.

🧩

Sensor Signal Conditioning

The ICL7126IPL+ can evaluate low-level sensor outputs where the final result only needs approximately four displayed digits and the source can settle during the measurement interval. Its approximately 1 pA typical input current is valuable for high-impedance sources, while the integrated reference and clock reduce the number of sensitive external nodes. Place input filtering close to the device, avoid long leakage-prone traces, and confirm the source-impedance limits in the data sheet. For faster conversions, greater resolution, or simultaneous measurement of multiple channels, a redesigned ADC architecture may be more appropriate.

What is the ICL7126IPL+?
The ICL7126IPL+ is a low-power, 3.5-digit CMOS analog-to-digital converter from Maxim Integrated with an integrated voltage reference and clock. According to the manufacturer product page, the ICL7126 family provides a complete measurement channel in one IC. This ICL7126IPL+ orderable variant uses a 40-pin PDIP package, a commercial temperature grade of 0°C to 70°C, and through-hole mounting for panel meters, portable instruments, and process-monitoring equipment.
What are the key specifications of ICL7126IPL+ that engineers should know?
The ICL7126IPL+ is a 3.5-digit, 0.05-percent-resolution CMOS ADC with a true differential input and reference architecture. It integrates a voltage reference and clock, offers guaranteed zero readings on all scales, and has approximately 1 pA typical input current. The device is packaged as a 40-pin PDIP and operates from 0°C to 70°C. According to the Intersil ICL7126 datasheet, these features support low-power precision measurement with reduced external circuitry.
Where can I download the ICL7126IPL+ datasheet PDF?
The official ICL7126 datasheet is accessible from the Analog Devices product page for the Maxim Integrated ICL7126. Open the Data Sheet document listed under the product documentation resources. The document provides the authoritative pin descriptions, electrical characteristics, timing information, operating limits, and application guidance needed for the ICL7126IPL+. Use the manufacturer document rather than relying solely on distributor summaries when laying out the PCB or calculating measurement accuracy.
Where can I find the ICL7126IPL+ pinout?
The ICL7126IPL+ pinout is documented in the manufacturer data sheet for the 40-pin PDIP package. Start with the pin-description table and follow the package orientation markings before assigning nets. The ICL7126 includes analog input, reference, clock, supply, ground, and associated control or interface functions, so every PCB net should be taken from the device documentation. The 40-pin standard DIP pin numbering also runs counterclockwise from pin 1 with the notch identifying the package end.
Can ICL7126IPL+ be used in a digital panel meter?
Yes, the ICL7126IPL+ is well suited to a digital panel meter because it combines a 3.5-digit conversion system, integrated reference, and clock in one package. Its 0.05-percent resolution and true differential measurement support stable display readings, while the guaranteed zero reading improves behavior near the center of the scale. The commercial temperature range of 0°C to 70°C suits indoor instruments, although the complete application circuit and display interface must follow the manufacturer recommendations.
What is the difference between ICL7126IPL+ and ICL7126CPL+?
The ICL7126IPL+ and ICL7126CPL+ are both 40-pin PDIP versions of the same ICL7126 3.5-digit converter family, and a documented cross-reference identifies ICL7126CPL+ as a complete replacement candidate. Their principal selection point is the orderable temperature-grade suffix, so the exact suffix must be checked against the operating-temperature requirements of the instrument. The manufacturer recommends ICL7136 for new designs, but ICL7126-family devices remain relevant when maintaining an existing 40-pin design.
Is TC7126IPL a drop-in replacement for ICL7126IPL+?
The TC7126IPL is a pin-compatible 40-DIP replacement candidate for the ICL7126IPL+, and a comparison source describes it as a device with consistent terminals and package characteristics. Its 3.5-digit CMOS ADC integrates the converter, display drivers, reference, and clock needed for a complete measurement system. Before substitution, verify enable, input-polarity, reference, timing, and electrical-limit details against both datasheets, particularly for designs that rely on a specific conversion sequence.
What can replace ICL7126IPL+?
ICL7126CPL+ is the closest documented drop-in replacement candidate for ICL7126IPL+ because it uses the same 40-pin PDIP format and is described as a complete replacement in a published comparison. TC7126IPL is another 40-DIP candidate with closely related integrated ADC functions. A qualified replacement still requires checking temperature grade, supply limits, reference behavior, timing, and system-level calibration requirements before production use.
When should I choose ICL7126IPL+ instead of ICL7126CPL+?
Choose ICL7126IPL+ when the instrument specifically calls for the IPL+ orderable designation and its commercial 0°C-to-70°C operating range. Choose ICL7126CPL+ when the CPL+ designation matches the original bill of materials or provides a documented 40-pin replacement path. Because the suffix can encode temperature grade, qualification, or packaging details, compare the complete manufacturer ordering information rather than selecting only from the family name.
Is ICL7126IPL+ suitable for battery-powered measurement equipment?
The ICL7126IPL+ is suitable for battery-powered measurement equipment when low power is a primary design goal. The Intersil datasheet describes the ICL7126 as a very-low-power 3.5-digit converter and identifies approximately 1 pA typical input current, which helps reduce loading of the measured source. Actual battery life depends on the complete supply voltage, conversion duty cycle, display load, reference circuitry, and leakage outside the converter itself.
How should the reference and input connections be designed for ICL7126IPL+?
The ICL7126IPL+ should use the true differential input and reference arrangement described by the manufacturer, with short, well-shielded analog traces and a clean grounding strategy. Keep the reference path stable and decouple the supply close to the device pins. Because the converter specifies approximately 1 pA typical input current, very high source impedance can still create meaningful offset from leakage and leakage noise. Confirm source impedance, acquisition timing, and capacitor values against the data sheet.
Where can I buy ICL7126IPL+ online?
Use the Request a Quote form on this page to request ICL7126IPL+ availability, current pricing, and lead time. The quote team can confirm the exact 40-pin PDIP orderable configuration and any available inventory without requiring a PCB redesign. Because lifecycle and inventory can change, request the current commercial status rather than relying on an old catalog listing or historical stock reference.
What is the price of ICL7126IPL+?
Use the Request a Quote form on this page for the current ICL7126IPL+ price and quantity breaks. The form is the appropriate channel for a quote because market availability, package configuration, and order quantity can affect the final commercial offer. No static price should be used in an engineering comparison because it may change independently of the device’s technical characteristics.
What is the lead time for ICL7126IPL+?
Submit the ICL7126IPL+ model and required quantity through the Request a Quote form on this page to obtain the current lead time. The manufacturer product page identifies the ICL7126 as a production family and recommends ICL7136 for new designs, but production status alone does not establish current stock or delivery timing for the specific IPL+ suffix. A written quotation should confirm the supply date and lot availability.
Is ICL7126IPL+ in stock?
Current ICL7126IPL+ stock should be requested through the Request a Quote form on this page. The manufacturer lists the ICL7126 product family as production, while the exact IPL+ commercial-grade suffix requires a separate inventory check. Request the quantity, authorized shipment destination, and desired delivery schedule so the response reflects the actual order configuration and current market position.
Does ICL7126IPL+ support automotive applications?
No automotive qualification is claimed for the ICL7126IPL+. The verified operating-temperature grade is commercial, from 0°C to 70°C, and the product is a through-hole measurement converter rather than an automotive-qualified component. An AEC-Q100-grade alternative would be required for an application with specified automotive qualification criteria. For industrial equipment, verify environmental requirements such as extended temperature, surge exposure, and long-term availability separately.

엔지니어링 참조 데이터: ICL7126IPL+ — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the ICL7126IPL+ when maintaining an existing design that specifically calls for the Maxim Integrated 40-pin PDIP commercial-grade ICL7126. Its integrated reference, clock, and 3.5-digit converter provide a compact measurement channel, while the through-hole package simplifies prototypes and repairable instruments. ICL7126CPL+ is the closest same-family replacement candidate when its exact ordering suffix satisfies the original temperature and qualification requirements. TC7126IPL is useful when a Texas Instruments 40-DIP part is available, but its internal timing, enable behavior, electrical limits, and system calibration must be checked before substitution. For new designs, compare the ICL7136 recommended by the manufacturer against lower-resolution or higher-resolution alternatives when display requirements, conversion speed, board area, or long-term availability have changed.

대체품과의 비교

파라미터 이 제품 ICL7126CPL+ TC7126IPL
Brand Maxim Integrated Maxim Integrated Texas Instruments
Package 40-pin PDIP 40-pin PDIP 40-pin PDIP
ADC Resolution 3.5 digits, 0.05 percent 3.5 digits, 0.05 percent 3.5 digits
Converter Technology CMOS successive-approximation ADC CMOS 3.5-digit ADC CMOS 3.5-digit ADC
Integrated Reference Yes Yes Yes
Integrated Clock Yes Yes Yes
Mounting Style Through-hole Through-hole Through-hole

주요 차별점

  • Exact-family 40-pin replacement path (vs ICL7126CPL+)
  • Single-IC measurement channel (vs TC7126IPL)
  • Low input loading (vs ICL7126CPL+)
  • Signed 3.5-digit measurement (vs TC7126IPL)

설계 노트

Route the analog input and reference nets as short, quiet traces, and place their associated bypass capacitors close to the appropriate ICL7126IPL+ pins. Keep switching-regulator nodes, relay contacts, and high-current return paths away from the measurement section. A continuous ground plane can help, but analog and digital currents should return to their intended reference points without sharing narrow neck routes that create measurable voltage drops.

Because the typical input current is approximately 1 pA, even a modest source impedance or contaminated PCB surface can create an unwanted voltage contribution. Use a guarded or well-cleaned input area, avoid long leakage-prone traces, and select input filtering only after confirming its settling behavior during conversion. Verify source impedance, acquisition timing, and capacitor tolerances against the manufacturer data sheet before assigning practical measurement resolution.

Do not treat the 3.5-digit display resolution as the complete system accuracy. Offset, reference error, resistor tolerance, leakage, noise, and calibration drift can all reduce end-to-end accuracy. Establish gain and offset calibration limits for the finished instrument, and include reference stability, source settling, display loading, and switch resistance in the error budget. Use the complete manufacturer data sheet to distinguish converter resolution from total measurement uncertainty.

The 40-pin PDIP footprint supports straightforward through-hole routing, but analog and digital functions still need deliberate separation. Maintain a common ground reference without creating high-current loops between the converter, display, and external interface. Place input and reference components near their associated pins, avoid running the reference trace parallel to switching nodes, and review the complete pin-description table against the physical package orientation before fabrication.

규정 준수 정보

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
무연
Unknown
무할로겐
Unknown
분쟁 광물
Unknown

The commercial ICL7126IPL+ is not presented as an AEC-Q100-qualified automotive device. RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations were not identified and are recorded as unknown.

데이터 검증일: 2026-11-04 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

ICL7126IPL+ datasheet ICL7126IPL+ specifications ICL7126IPL+ pinout ICL7126IPL+ equivalent ICL7126IPL+ replacement ICL7126IPL+ price ICL7126IPL+ stock Maxim Integrated ICL7126IPL+ ICL7126IPL+ 40 pin PDIP ICL7126IPL+ panel meter ICL7126IPL+ vs ICL7126CPL+ ICL7126IPL+ vs TC7126IPL ICL7126 3.5 digit ADC ICL7126 application circuit ICL7126 schematic

관련 부품 & 용어

Maxim Integrated Analog Devices Intersil Texas Instruments ICL7126IPL+ ICL7126CPL+ TC7126IPL ICL7116CPL+ 3.5-digit ADC analog-to-digital converter successive-approximation ADC dual-slope ADC CMOS integrated circuit semiconductor differential input voltage reference integrated clock 0.05-percent resolution true polarity typical input current panel meter portable test equipment process monitoring 40-pin PDIP DIP package family through-hole package surface-mount package
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4