Texas Instruments

INA117AM - ±200V Difference Amplifier | Texas Instruments

부품 번호: INA117AM ✓ 활성
±200 V Vdss TO-99-8 metal can Package
MOQ: 1 |

INA117AM 개요

Texas Instruments INA117AM is a precision unity-gain difference amplifier with a common-mode input range up to ±200 V, a 200 kHz bandwidth, and an 8-pin TO-99 metal-can package. It is designed to extract small differential voltages from high-voltage or high-impedance signal chains without requiring an external precision resistor network.

A difference amplifier is a specialized amplifier topology that amplifies the voltage between two inputs while rejecting a voltage common to both inputs. The INA117 belongs to the broader hierarchy of differential amplifiers, instrumentation signal conditioners, amplifier ICs, and analog semiconductor devices. Its integrated thin-film resistor network provides matched ratios, allowing accurate differential measurement when its common-mode and output operating limits are respected.

The monolithic INA117 combines a precision operational amplifier with an integrated resistor network. Its unity-gain architecture makes it suitable for direct differential sensing, while the ±200 V common-mode capability separates the usable input signal from the potentially much larger voltage appearing at both inputs. The 200 kHz bandwidth supports measurements beyond static DC conditions but remains focused on precision signal extraction rather than high-speed data conversion. The INA117 family is also specified for operation from -40°C to 85°C.

Two package options are available for the INA117 family: an 8-pin plastic mini-DIP and an 8-pin SO-8 surface-mount package. The INA117AM is the TO-99-8 metal-can ordering option shown by the manufacturer and distributor listings. The metal-can format supports compact through-hole insertion and is useful where a robust, shielded package is preferred over a surface-mount carrier. Its 8-pin configuration also means the differential amplifier requires careful signal routing and grounding around the circular package.

Typical applications include high-voltage current sensing, power-converter feedback monitoring, battery-system measurement, industrial transducer interfaces, and instrumentation where a small differential signal is superimposed on a large common-mode voltage. In these systems, the INA117 can reject the common signal and present a scaled differential result to an ADC, comparator, control loop, or measurement instrument. Input protection, common-mode transient limits, output saturation, and thermal behavior must be evaluated together.

When implementing this device, verify that neither input exceeds the specified common-mode range under every operating condition. Keep sensitive input and reference connections short, use a stable low-noise supply, and provide adequate return paths for high-impedance sources. Account for output settling and bandwidth when filtering small signals from fast common-mode transients, since common-mode rejection and transient performance are distinct design considerations.

This product page combines the manufacturer’s device description, package information, operating-temperature range, exact ordering identifier, source documents, application guidance, and qualified replacement analysis. It also distinguishes genuine pin-compatible alternatives from devices that share only the broad function of high-voltage difference amplification, helping engineers make a PCB-level replacement decision rather than a feature-level comparison.

드롭인 대체품: INA117AM — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: INA117AM (동일 폼 팩터 및 풋프린트) — 차이점: Bandwidth, Gain, Mounting Type, Operating Temperature Range, Package.

Texas Instruments
Bandwidth: 200 kHz for CSO: SHE
Gain: 1 unity gain
Mounting Type: Through-hole
비교 대상: INA117AM →

INA117BM

✅ 드롭인
Texas Instruments
📦 TO-99-8
Precision unity-gain difference amplifier · 1 circuit · 1 unity gain · 200 kHz for CSO: SHE · 500 kHz for CSO: TID · 0.001%

가격 문의

데이터시트 보기 →

INA117AM 최대 정격 & 전기적 특성

Amplifier Type Precision unity-gain difference amplifier
Number of Circuits 1 circuit
Common-Mode Input Voltage Range ±200 V
Gain 1 (unity gain)
Bandwidth 200 kHz
Architecture Monolithic precision operational amplifier with integrated thin-film resistor network
패키지 TO-99-8 metal can
핀 수 8 pins
실장 유형 Through-hole insertion
동작 온도 범위 -40°C to +85°C
Family Package Options 8-pin plastic mini-DIP and 8-pin SO-8 surface mount

INA117AM 8-pin plastic mini-dip and 8-pin so-8 surface mount 핀 구성 가이드

INA117AM(8-pin plastic mini-dip and 8-pin so-8 surface mount 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.

INA117AM의 8-pin plastic mini-dip and 8-pin so-8 surface mount 패키지 핀아웃 다이어그램

다음에 대한 상세 핀아웃 데이터 없음: INA117AM.

다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.

일반적인 애플리케이션

INA117AM 적합 용도: 6 애플리케이션s: High-Voltage Current Sensing, Power-Converter Feedback Monitoring, Battery-System Measurement, Industrial Transducer Interfaces, Precision Signal Isolation Across High Side, Laboratory and Instrumentation Front Ends.

⚡

High-Voltage Current Sensing

The INA117AM fits high-voltage current sensing when a small shunt voltage appears across a resistive sense element while both measurement inputs share a large common-mode voltage. Its ±200 V common-mode range provides substantial headroom in motor, power-converter, and industrial drive systems, while unity gain preserves the measured differential signal for an ADC or controller. Place the amplifier across the shunt and provide a low-impedance reference return. Verify differential input limits, output swing, supply compatibility, and the effects of shunt impedance and bandwidth before production use.

🔧

Power-Converter Feedback Monitoring

INA117AM can monitor small feedback or error voltages in power-converter systems where switching-node or bus voltage appears at both inputs. The ±200 V common-mode range allows the difference amplifier to operate close to elevated power rails without an external high-voltage divider. Use it near the controller feedback network to improve local signal integrity and reduce contamination from the switching node. The 200 kHz bandwidth should be checked against ripple and transient requirements, and the output must remain within the amplifier’s linear output range.

🔋

Battery-System Measurement

The INA117AM is appropriate for battery-management systems that must measure a small differential cell or balancing signal while the input pair sits at a substantial common-mode voltage. The integrated thin-film network supports accurate difference amplification without a discrete resistor divider, and the ±200 V common-mode capability covers many traction, stationary, and industrial battery buses. The designer must still confirm polarity, input protection, supply availability, output headroom, and operating temperature. Protection components should handle fault energy without distorting the measurement bandwidth.

🏭

Industrial Transducer Interfaces

INA117AM can serve as the front end for industrial transducers that produce a small differential output while sharing a high common-mode voltage. Its precision unity-gain architecture helps preserve transducer signals without requiring an external matched divider, and the metal-can TO-99-8 package provides a compact through-hole implementation. Connect the output to an ADC or instrumentation stage with adequate grounding and isolation. Check input bias current, source impedance, output swing, supply range, and common-mode transient behavior because a high input voltage does not replace application-specific protection.

📡

Precision Signal Isolation Across High Side

INA117AM can amplify a low-level differential signal referenced to a high-side or floating potential, making it useful when the measured quantity is small but its common-mode voltage is large. The integrated precision resistor network simplifies matching compared with a discrete difference stage. For a working design, establish a suitable local supply and reference, keep the input loop compact, and verify that both inputs remain within the ±200 V common-mode region even during switching events. The 200 kHz bandwidth is appropriate for many measurement-band signals but not arbitrary high-frequency transients.

🧪

Laboratory and Instrumentation Front Ends

INA117AM is useful in laboratory instrumentation that must measure small differential signals riding on large common-mode voltages. The unity-gain topology gives engineers a defined gain of 1, while the 200 kHz bandwidth supports audio-band and general-purpose measurement work. Use a low-noise local supply and a clean reference return, and evaluate output offset, settling, and common-mode rejection at the actual signal frequency. Because the TO-99-8 package uses a circular through-hole lead arrangement, follow the package drawing exactly when creating the footprint.

추천 제품 요약

INA117BM Texas Instruments 사용처: High-Voltage Current Sensing, Power-Converter Feedback Monitoring, Battery-System Measurement, Industrial Transducer Interfaces, Precision Signal Isolation Across High Side, Laboratory and Instrumentation Front Ends INA149 High-voltage difference-amplifier family for design comparison 사용처: High-Voltage Current Sensing, Power-Converter Feedback Monitoring, Industrial Transducer Interfaces, Precision Signal Isolation Across High Side, Laboratory and Instrumentation Front Ends INA188 Current and voltage measurement amplifier discussed for replacement analysis 사용처: Battery-System Measurement
What is the INA117AM?
The INA117AM is a precision unity-gain difference amplifier that measures small differential voltages in the presence of common-mode signals up to ±200 V. According to the Texas Instruments manufacturer datasheet, the device combines a precision operational amplifier and an integrated thin-film resistor network in one monolithic IC. The INA117AM ordering option uses an 8-pin TO-99-8 metal-can package and is specified over a -40°C to 85°C temperature range.
Where can I download the INA117 datasheet PDF?
The official INA117 datasheet PDF is available from the Texas Instruments document link on this page. It describes the precision unity-gain architecture, integrated thin-film network, ±200 V common-mode capability, package options, and operating characteristics. Use the manufacturer document for final pin assignments, absolute maximum ratings, supply requirements, input and output limits, and application guidance before committing a TO-99-8 circuit to a PCB.
Where can I find the INA117AM pinout?
The INA117AM pin assignments are found in the pin-configuration section of the Texas Instruments INA117 manufacturer datasheet. The device has 8 pins in a TO-99-8 metal-can package, and its numbering follows the physical package rather than the SO-8 variant. Because the circular lead arrangement differs from a conventional dual-row IC, use the package drawing to assign each lead before PCB routing. Do not infer TO-99-8 numbering from an SO-8 footprint.
What are the key specifications of INA117AM that engineers should know?
The key INA117AM specifications are a ±200 V common-mode input range, unity gain, 200 kHz bandwidth, one amplifier circuit, and an 8-pin TO-99-8 metal-can package. The Texas Instruments manufacturer datasheet identifies the INA117 as a precision unity-gain difference amplifier built from a precision operational amplifier and an integrated thin-film resistor network. Its specified operating temperature range is -40°C to 85°C, making it suitable for industrial instrumentation when the complete device operating limits are observed.
How does the INA117AM reject common-mode voltage?
The INA117AM uses an integrated precision resistor network and matched amplifier topology to amplify the voltage difference between its inputs while suppressing the voltage shared by both inputs. The manufacturer datasheet identifies the architecture as a monolithic combination of a precision operational amplifier and thin-film resistor network. Its common-mode input range extends to ±200 V, allowing the device to extract a small differential signal without requiring a separate external resistor divider.
Can INA117AM measure small signals on high-voltage rails?
Yes, the INA117AM is designed to measure small differential voltages in the presence of common-mode signals up to ±200 V. This makes it appropriate for high-voltage sensing when both inputs remain inside the specified common-mode range and the output can settle within the amplifier’s output limits. The Texas Instruments manufacturer datasheet should be checked for differential input limits, output swing, supply requirements, and behavior during common-mode transients before finalizing the measurement chain.
What is the bandwidth of the INA117AM?
The INA117AM has a 200 kHz bandwidth. This supports measurement of differential signals extending well beyond DC while retaining the precision-focused architecture of the INA117 family. Bandwidth must be considered together with common-mode rejection, output settling, source impedance, and any post-amplifier filtering. A useful design practice is to place suitable input protection and filtering close to the amplifier without adding excessive capacitance that could impair settling.
Where can I buy INA117AM online?
Use the Request a Quote form on this page to request INA117AM availability, current lead time, order quantity, and commercial terms from XAIPART. The part is identified specifically as the Texas Instruments INA117AM in an 8-pin TO-99-8 package. Provide the required quantity and assembly preferences with the request so the correct ordering option can be confirmed without confusing it with the INA117 family’s plastic mini-DIP or SO-8 versions.
What is the price of INA117AM?
Current INA117AM pricing is shown through the Request a Quote form on this page and depends on order quantity, sourcing conditions, and packaging requirements. Submit the quantity you need to obtain a current quotation for the exact INA117AM ordering option. The device is a TO-99-8 metal-can package, so confirm that the requested format is appropriate for your assembly process before accepting a quotation.
What is the lead time and stock status for INA117AM?
Request current INA117AM stock status and lead time through the Request a Quote form on this page. Lead time can vary with order quantity, package availability, and supply conditions, so a current quotation is the appropriate source for planning. Identify the full ordering code INA117AM when requesting supply, ensuring that the order is for the TO-99-8 version rather than another member of the INA117 package family.
What can replace the INA117AM?
The INA117BM is the qualified same-package replacement identified for the INA117AM, because both use the 8-pin TO-99-8 format and belong to the same Texas Instruments INA117 family. Its TO-99-8 lead arrangement preserves the PCB footprint requirement. Texas Instruments’ replacement discussion treats INA828 and INA188 as related possibilities, but their package and electrical requirements must be checked before either is treated as a drop-in substitute.
Is INA117BM the same as INA117AM?
INA117BM is a closely related TO-99-8 member of the Texas Instruments INA117 family and is the relevant same-package option for a PCB-level replacement. Both ordering options use the 8-pin TO-99-8 package, while the exact electrical and grade-related distinctions should be confirmed in the manufacturer ordering information. Do not substitute an SO-8 INA117 variant on an existing TO-99-8 board because the lead arrangement and footprint are different.
INA117AM vs INA149 - which is better for high-voltage sensing?
Choose INA117AM when the design specifically needs the INA117’s ±200 V common-mode range and an existing TO-99-8 footprint. INA149 is another high-voltage difference-amplifier family named in the comparison material, but its package and detailed electrical limits must be verified before substitution. The correct decision depends on common-mode voltage, gain requirement, bandwidth, output swing, supply voltage, and whether the PCB can be changed—not merely on the shared measurement function.
When should I choose INA117AM instead of a lower-voltage difference amplifier?
Choose INA117AM when both sensing inputs can share a common-mode voltage as high as ±200 V but the useful signal between them is small. A lower-voltage difference amplifier may be preferable when its common-mode range comfortably covers the application and offers lower cost, lower supply demand, or tighter precision. Confirm the actual worst-case common-mode excursion, transient margin, output swing, and bandwidth before selecting the higher-voltage INA117 architecture.
Is INA117AM suitable for industrial instrumentation and power monitoring?
INA117AM is suitable for many industrial instrumentation, power-monitoring, and high-voltage feedback applications when the signal chain remains within the device ratings. Its ±200 V common-mode input range is the primary fit for measurements involving elevated common-mode voltage, while the -40°C to 85°C operating specification supports industrial temperature conditions. Use the manufacturer datasheet to verify supply voltage, input protection, output swing, thermal performance, and transient behavior.
What design limits matter most when using INA117AM?
The most important design limits are the ±200 V common-mode input range, the differential input rating, output swing, supply voltage, and operating temperature. The manufacturer datasheet provides the authoritative absolute maximum ratings and recommended operating conditions. Keep input transients controlled, provide a low-impedance reference or return connection, and verify that the selected output signal remains within the linear operating range under worst-case input and load conditions.

엔지니어링 참조 데이터: INA117AM — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose INA117AM when a small differential signal must be measured while both inputs can experience common-mode voltages up to ±200 V and the board already accommodates an 8-pin TO-99-8 footprint. Its unity gain, integrated thin-film network, 200 kHz bandwidth, and -40°C to 85°C operating range suit precision measurement and power-monitoring circuits. Choose INA117BM when it is the specifically approved ordering option for the same package and electrical design. Consider INA149 when comparing alternative high-voltage difference-amplifier architectures, but verify its package, gain, bandwidth, supply, and output limits before changing the PCB. INA828 and INA188 may support related measurement functions, yet they are not established as TO-99-8 drop-in replacements here. Final selection must include worst-case common-mode voltage, differential input limits, output swing, supply range, thermal dissipation, and transient protection.

대체품과의 비교

파라미터 이 제품 INA117BM
Package TO-99-8 metal can TO-99-8 metal can
Brand Texas Instruments Texas Instruments
Amplifier Type Precision unity-gain difference amplifier Precision unity-gain difference amplifier
Gain 1 (unity gain) 1 (unity gain)
Bandwidth 200 kHz 200 kHz
Operating Temperature -40°C to +85°C -40°C to +85°C
Circuit Count 1 circuit 1 circuit
Internal Resistor Network Integrated thin-film resistor network Integrated thin-film resistor network

주요 차별점

  • High common-mode measurement capability (vs INA149)
  • Integrated precision resistor network (vs INA117BM)
  • Defined unity-gain measurement behavior (vs INA828)

설계 노트

Do not treat the ±200 V common-mode capability as permission to apply arbitrary voltages to either input. Check the differential input rating, absolute maximum ratings, input current behavior, and output swing in the Texas Instruments manufacturer datasheet. Add protection that limits fault energy without introducing excessive leakage or capacitance, and verify that startup, shutdown, and fault conditions cannot move either input outside its safe operating region.

Route the two sense inputs as a tightly coupled pair and provide a low-impedance return close to the source. The TO-99-8 package has a circular lead arrangement, so create the footprint from the package drawing rather than adapting an SO-8 land pattern. Keep high-current switching paths and protection devices away from the input pins. A solid ground plane, short output route, and local supply bypassing help preserve signal integrity around the monolithic amplifier and integrated resistor network.

Evaluate the complete signal path against the 200 kHz bandwidth rather than checking only DC accuracy. Source impedance, input capacitance, protection leakage, output loading, and post-amplifier filtering can each affect settling and differential-to-common-mode conversion. Measure common-mode rejection at the frequencies present in the design and include startup or protection-related transients in system validation. The manufacturer datasheet remains the controlling reference for recommended operating conditions.

Design the local supply for the amplifier’s exact voltage and current requirements, including startup behavior at the highest expected input common-mode voltage. Confirm that the output can remain linear at the intended signal level and load. Because the TO-99-8 package must dissipate internally, calculate worst-case internal power from the actual supply, output voltage, and load. Use the manufacturer thermal information and maintain the package’s specified environmental and copper conditions.

규정 준수 정보

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
무연
Unknown
무할로겐
Unknown
분쟁 광물
Unknown

The INA117AM is a precision analog amplifier in a TO-99-8 package. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals statements require confirmation from the manufacturer’s current product documentation.

관련 검색

ina117 datasheet ina117 pdf ina117 datasheet pdf INA117AM datasheet INA117AM pinout INA117AM TO-99-8 INA117AM ±200V amplifier INA117AM high voltage sensing INA117AM drop-in replacement INA117AM vs INA149 INA117AM price INA117AM stock Texas Instruments INA117AM what is INA117AM

관련 부품 & 용어

Texas Instruments INA117AM INA117BM INA117 INA149 INA828 INA188 difference amplifier differential amplifier precision amplifier unity-gain amplifier operational amplifier analog IC common-mode voltage input bias current common-mode rejection ratio integrated thin-film resistor network TO-99-8 metal-can package through-hole package high-voltage sensing industrial instrumentation power-converter feedback battery management 200 kHz bandwidth
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료