INA128UA/2K5 - 2.5 Gain Current-Sense Amplifier | Texas Instruments
부품 번호: INA128UA/2K5 ✓ 활성INA128UA/2K5 개요
A current-shunt amplifier belongs to the instrumentation and measurement IC hierarchy. It sits between a current-sense resistor and a downstream data converter or control circuit. Unlike a direct high-voltage measurement approach, the shunt converts current into a small differential voltage that can be amplified accurately. The INA128UA/2K5 is therefore suited to power-conversion, industrial-control, laboratory, and embedded monitoring circuits.
The 2.5 V/V gain setting translates the shunt differential voltage into an amplified output with a multiplication factor of 2.5. In an ideal signal-chain calculation, a 10 mV shunt differential would produce a 25 mV amplifier output before accounting for offset, gain error, input bias effects, and output-stage limitations. Designers should use those nonideal characteristics from the manufacturer datasheet when setting the system error budget.
The differential measurement architecture helps reject voltage common to both shunt terminals. This is important because the input pins may not be at ground, and a practical current-measurement circuit often places substantial supply voltage across the shunt. Correct input common-mode range, supply voltage, output swing, and grounding are therefore as important as the nominal gain when selecting this device for a new design.
Typical uses include output-current monitoring in industrial power supplies, DC motor control, battery-management telemetry, laboratory instrumentation, and precision current measurement for data-acquisition systems. The device can sit beside a shunt and feed an ADC such as the AD7888BR, AD7710AR, or AD7705BR. The downstream converter must provide adequate input range and resolution for the amplified shunt signal.
PCB layout should keep the shunt-to-amplifier route short and symmetric, use a quiet ground reference for the output return, and place input filtering close to the device. Avoid routing shunt-current paths through sensitive signal traces, because their high di/dt can create coupling and measurement errors even when the electrical schematic is correct.
This product page organizes the INA128UA/2K5 identity, application guidance, comparison boundaries, and sourcing information. Because no manufacturer document, electrical table, package drawing, or distributor listing URL accompanies the component record, every unsupported quantitative limit remains explicitly marked rather than being inferred.
드롭인 대체품: INA128UA/2K5 — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: INA128UA/2K5 (동일 폼 팩터 및 풋프린트) — 차이점: Product Type, Number of Channels, Quiescent Current.
이 제품에는 사용 가능한 드롭인 대체품이 없습니다.
대체품 요청INA128UA/2K5 최대 정격 & 전기적 특성
| Product Type | Precision current-shunt amplifier |
| Nominal Gain | 2.5 V/V |
| Package Type | UA SOIC-8 |
| 핀 수 | 8 pins |
| 실장 유형 | Surface mount |
INA128UA/2K5 ua soic-8 핀 구성 가이드
INA128UA/2K5(ua soic-8 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.
다음에 대한 상세 핀아웃 데이터 없음: INA128UA/2K5.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
INA128UA/2K5 적합 용도: 6 애플리케이션s: Industrial Power-Supply Output Monitoring, DC Motor Current Feedback, Battery Current Telemetry, Precision Laboratory Current Measurement, Server and Data-Center Rail Sensing, Embedded Sensor and Actuator Monitoring.
Industrial Power-Supply Output Monitoring
The INA128UA/2K5 can amplify the differential voltage across a low-value shunt in an industrial power-conversion output. Its nominal 2.5 V/V gain increases the measurement signal before it reaches an ADC such as the AD7710AR or AD7888BR, reducing the proportion of converter resolution consumed by a small shunt voltage. The shunt must dissipate the expected fault current, and the amplifier input common-mode voltage must remain within the manufacturer limits at every operating point.
추천
DC Motor Current Feedback
In a DC motor controller, the INA128UA/2K5 can condition the shunt differential generated by armature current. The 2.5 V/V nominal gain provides signal headroom before a control ADC samples the value, while the differential input arrangement supports measurement above ground when the design keeps the amplifier within its specified common-mode range. Motor transients make bandwidth and common-mode verification essential; use the Texas Instruments datasheet to confirm that startup and braking current remain compatible.
추천
Battery Current Telemetry
The INA128UA/2K5 is applicable to battery-current telemetry when a shunt is placed in the charge or discharge path and the resulting signal is amplified for an ADC. The 2.5 V/V nominal gain helps preserve small current measurements without requiring an extremely low-value shunt. Designers must account for battery voltage, transient peaks, shunt dissipation, and the amplifier's specified common-mode range. An ADC such as the AD7705BR can provide a low-bandwidth measurement channel for energy-management equipment.
추천
Precision Laboratory Current Measurement
For laboratory instrumentation, the INA128UA/2K5 can amplify a shunt voltage so that a measuring ADC receives a signal that is easier to resolve than the raw differential input. The nominal 2.5 V/V gain must be included in the calibration equation, along with offset and gain error from the manufacturer limits. Keep the analog path short, provide a stable ADC reference, and verify input-referred noise against the smallest current increment that the instrument must resolve.
추천
Server and Data-Center Rail Sensing
The INA128UA/2K5 can be evaluated for server or data-center rail-current sensing when a shunt, amplifier, and converter form a compact measurement chain. The amplifier's nominal 2.5 V/V gain scales the shunt differential, while an ADC such as the AD7888BR can digitize the result for power telemetry. Because these systems operate at changing rail voltages and load transients, the common-mode range, transient response, output settling, and thermal performance must be checked against the worst-case operating envelope.
추천
Embedded Sensor and Actuator Monitoring
The INA128UA/2K5 can monitor current in an embedded actuator, solenoid, or power-control stage by amplifying the voltage across a sense resistor. Its 2.5 V/V nominal gain can improve use of an ADC input range, but the selected converter and microcontroller must sample the resulting signal with adequate resolution. Keep the shunt-current path away from sensitive traces, observe the device's common-mode restrictions, and include overload protection so an abnormal current does not exceed the shunt or amplifier operating conditions.
추천
추천 제품 요약
엔지니어링 참조 데이터: INA128UA/2K5 — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 |
|---|---|
| Brand | Texas Instruments |
| Package | UA SOIC-8 |
| Product Type | Precision current-shunt amplifier |
| Nominal Gain | 2.5 V/V |
| Input Type | Differential current-shunt measurement |
| Mounting Type | Surface mount |
설계 노트
Route the two shunt connections to the amplifier as a short, closely coupled differential pair. Place any input-filter network close to the relevant pins and avoid sharing sensitive return paths with the high-current shunt conductor. The shunt itself determines much of the measurement behavior, so its resistance, power rating, Kelvin connections, and thermal coefficient must be selected together with the 2.5 V/V amplifier gain.
Check the complete signal chain against the smallest and largest expected current. The nominal relationship is VOUT = 2.5 × VSHUNT before nonideal errors, but the actual output must also satisfy the amplifier's input common-mode range and output swing. Confirm startup, overload, and transient conditions rather than sizing the circuit only from nominal load current.
Do not assume that two amplifiers in the same package are interchangeable merely because their packages match. The INA128UA/2K5 gain designation is a functional part of the orderable device. When considering a replacement, verify pin functions, 2.5 V/V gain, supply range, common-mode range, bandwidth, accuracy, temperature grade, and footprint before approving a substitution.
규정 준수 정보