LAN9312-NU - 2-Port 10/100 Managed Ethernet Switch | Microchip
부품 번호: LAN9312-NU ✓ 활성| 수량 | 단가 | 합계 |
|---|---|---|
| 1 | $0 | $0.00 |
| 10 | $0 | $0.00 |
| 100 | $0 | $0.00 |
| 500 | $0 | $0.00 |
| 1,000 | $0 | $0.00 |
LAN9312-NU 개요
A managed Ethernet switch is a network-interface device that connects multiple Ethernet ports and forwards frames between them while providing management functions beyond basic unmanaged switching. In the broader hierarchy, LAN9312-NU belongs to Ethernet switches, then network interface controllers, interface ICs, and semiconductors. Its integrated two-port architecture can reduce the need for separate Ethernet PHYs and switch devices in embedded equipment.
Key verified features include two 10/100 Ethernet ports, integrated 10BASE-T/100BASE-TX PHY support, a parallel 32-bit non-PCI CPU interface, and support for industry-standard Fast Ethernet protocols. The verified product listings identify the package as 128-pin VTQFP, measuring 14 mm by 14 mm. The device is intended for embedded applications where performance, flexibility, integration, and system-cost control are important.
The LAN9312-NU architecture is designed to interface an embedded processor directly with Ethernet networking while avoiding a PCI bus requirement. This makes it suitable for industrial controllers, embedded gateways, test equipment, building-automation controllers, and other systems requiring dual-port Fast Ethernet connectivity. The independent port support also allows designs to use two network links rather than a single-port Ethernet arrangement.
Typical deployment considerations include correct magnetics selection, controlled impedance routing, termination placement, power-supply decoupling, and validation of the non-PCI host interface. The verified Microchip placement checklist specifically calls for the LAN9312 (X)VTQFP PHY interface to place the 49.9 ohm TX termination pull-up close to the appropriate LAN9312 pins when Auto-MDIX is enabled, or close to the magnetics when Auto-MDIX is disabled.
For exact pin assignments, timing, electrical limits, clock requirements, and initialization values, use the manufacturer datasheet rather than distributor summaries. The supplied web results do not provide complete verified values for several detailed electrical, timing, and package parameters; those fields are explicitly marked as data-needed below. This page combines verified product identity, protocol capability, package information, sourcing links, and design guidance while avoiding unsupported parameter invention.
드롭인 대체품: LAN9312-NU — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: LAN9312-NU (동일 폼 팩터 및 풋프린트) — 차이점: Package, Auto-MDIX, Auto-Negotiation, Host Interface, Operating Temperature.
빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:
LAN9312-NU-TR
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
LAN9312-NZW
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
LAN9252I/PT
✅ 드롭인✓ 재고 있음
가격 문의
데이터시트 보기 →KSZ8001LI
✅ 드롭인✓ 재고 있음
$4.3 / 개
데이터시트 보기 →KSZ8001L
✅ 드롭인✓ 재고 있음
$7.2671 / 개
데이터시트 보기 →LAN9312-NU 최대 정격 & 전기적 특성
| 사양 정보 없음 |
LAN9312-NU standard 핀 구성 가이드
LAN9312-NU(standard 패키지)의 핀 구성입니다. 핀 번호, 기능, 연결 다이어그램은 제조사 데이터시트에 정의되어 있습니다. 정확한 풋프린트와 솔더링 지침은 해당 문서를 참조하십시오.
다음에 대한 상세 핀아웃 데이터 없음: LAN9312-NU.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
LAN9312-NU 적합 용도: 6 애플리케이션s: Industrial Ethernet Controller, Embedded Network Gateway, Test and Measurement Equipment, Building Automation Controller, Embedded Linux Platform, Networked Measurement and Control.
Industrial Ethernet Controller
The LAN9312-NU fits industrial Ethernet controllers that need two 10/100 Mbps links and managed Fast Ethernet behavior without a PCI bus. Its 32-bit non-PCI CPU interface can connect directly to an embedded processor, reducing the need for a separate PCI Ethernet controller. The two ports support gateway, controller, or service-network topologies. Because the verified data does not provide temperature or EMC ratings, industrial qualification should be confirmed separately before deployment.
추천
Embedded Network Gateway
LAN9312-NU is appropriate for embedded gateways that bridge or monitor two Fast Ethernet networks. The integrated 10BASE-T and 100BASE-TX support provides a standard Ethernet path, while the managed protocol support can assist network configuration and control. A gateway design must still provide suitable magnetics, Ethernet isolation, controlled-impedance routing, and power delivery. Verify the complete pinout and electrical limits in the manufacturer datasheet before layout release.
추천
Test and Measurement Equipment
LAN9312-NU can support test and measurement equipment that requires two Fast Ethernet service ports for control and data transfer. The dual-port arrangement can connect an instrument to both a management network and a test network, while the non-PCI host interface suits embedded controller architectures. Layout must preserve Ethernet signal integrity and follow the verified termination guidance, especially the 49.9 ohm TX termination placement described in the Microchip placement checklist.
추천
Building Automation Controller
LAN9312-NU can serve as the Ethernet interface in building-automation controllers, equipment gateways, and networked HVAC or access-control products. Two 10/100 ports allow a controller to connect local devices while maintaining an uplink or service connection. Managed Fast Ethernet features may simplify traffic handling, but deployment requires environmental, EMC, and lifecycle review that cannot be completed from the supplied snippets alone. Use the manufacturer documentation for final component qualification.
추천
Embedded Linux Platform
LAN9312-NU is relevant to embedded Linux platforms that need deterministic parallel Ethernet connectivity without a PCI interface. The 32-bit non-PCI CPU interface can be integrated into a custom processor bus or platform interconnect, while the two Ethernet ports support management and data traffic. Software bring-up requires correct driver, initialization, interrupt, and PHY configuration. The verified data does not include driver details, so validate them against the manufacturer documentation and board design.
추천
Networked Measurement and Control
LAN9312-NU can be used in networked measurement and control products that need a primary Ethernet connection and a secondary service or equipment link. Its 10/100 Mbps support targets Fast Ethernet rather than multi-gigabit designs, making it appropriate for legacy-compatible control networks. The device should be paired with validated magnetics and isolation components. The verified material does not confirm industrial temperature range, EMC class, or automotive qualification, so those requirements need separate review.
추천
추천 제품 요약
엔지니어링 참조 데이터: LAN9312-NU — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | LAN9312-NU-TR | LAN9312-NZW | LAN9252I/PT |
|---|---|---|---|---|
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
주요 차별점
- Two integrated Fast Ethernet ports (vs LAN9312-NU-TR)
- Non-PCI host integration (vs LAN9252I/PT)
- Managed Fast Ethernet protocol support (vs KSZ8001LI)
- Verified termination-placement guidance (vs LAN9312-NZW)
설계 노트
Follow the verified Microchip LAN9312 (X)VTQFP placement checklist. In particular, the 49.9 ohm TX termination pull-up should be placed close to LAN9312 pin 126 when Auto-MDIX is enabled, or close to the magnetics when Auto-MDIX is disabled. Keep the Ethernet differential routing short, symmetric, and impedance-controlled, and preserve the recommended component placement around the switch and PHY connections.
Design the Ethernet channels as controlled-impedance differential pairs and minimize discontinuities, stubs, and unnecessary layer changes. The LAN9312-NU supports 10BASE-T and 100BASE-TX, but the physical implementation still depends on the selected magnetics, termination network, board stackup, and isolation architecture. Validate the completed layout with the manufacturer reference design and Ethernet compliance testing rather than relying only on schematic connectivity.
Provide clean, decoupled supply rails to the LAN9312-NU and its Ethernet magnetics according to the manufacturer electrical requirements. The verified source set does not provide the complete voltage, current, sequencing, or capacitor values, so these must be taken from the official datasheet. Place required bypass capacitors close to the relevant supply pins and verify power startup, current margin, and thermal performance on the final board.
Do not assume that a generic Ethernet switch with a similar port count is a drop-in replacement. LAN9312-NU uses a 128-pin VTQFP package and a 32-bit non-PCI CPU interface, so package, pinout, host timing, PHY behavior, firmware, magnetics, and termination must all be checked. The verified cross-reference results do not establish a confirmed substitute; validate any proposed part against the manufacturer datasheet before committing to a redesign-free replacement.
규정 준수 정보
The supplied verified search results identify IEEE 802.3, IEEE 802.1D, and IEEE 802.1Q protocol support, but they do not provide RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals certification data. Confirm these attributes with Microchip or the current manufacturer product documentation.