Analog Devices

LT1101CH - Precision Micropower Instrumentation Amplifier | Analog Devices

부품 번호: LT1101CH ✓ 활성
5 V Vdss 8-terminal TO-5, round metal package Package
MOQ: 1 |

LT1101CH 개요

Analog Devices LT1101CH is a precision, micropower, single-supply instrumentation amplifier with fixed gain of 10 or 100, supplied in an 8-terminal round TO-5 package. The device is characterized for operation from a single 5 V supply, a single lithium cell, two Ni-Cad batteries, and dual ±15 V supplies. Its instrumentation-amplifier architecture combines differential input measurement with internally established fixed gain, reducing the need for external gain-setting components.

An instrumentation amplifier is a specialized amplifier category optimized for measuring small differential signals while rejecting common-mode voltage. The LT1101CH belongs to the broader precision-amplifier hierarchy, combining low power consumption with fixed-gain operation. This makes it useful where a sensor output must be amplified and measured accurately without adding a separate precision gain stage.

The LT1101CH provides fixed gains of 10 and 100, allowing designers to match amplification to the input-signal range. Its micropower operating characteristics are particularly valuable in portable instrumentation powered from a single 5 V supply or battery source. Operation from dual ±15 V supplies also supports higher-level laboratory and industrial signal chains. The manufacturer specifies the device for both single- and dual-supply conditions, enabling one amplifier family to cover different measurement environments.

The LT1101 architecture is intended for differential signal conditioning, where common-mode rejection and stable closed-loop gain help preserve measurement accuracy. Fixed gain reduces external resistor-network sensitivity and simplifies calibration, although the LT1101CH does not offer the user-adjustable gain flexibility of general-purpose three-op-amp instrumentation amplifiers. Circuit design must therefore account for the fixed gain and the manufacturer’s recommended input, output, and supply-bypass connections.

Typical applications include battery-powered sensor interfaces, biomedical instrumentation, industrial process measurement, portable test equipment, and low-level bridge or transducer signal amplification. A single-supply implementation is particularly suitable for compact instruments that cannot accommodate negative rails. The device can also serve in higher-voltage laboratory systems operated from ±15 V supplies when the common-mode and output ranges remain within the specified limits.

When selecting a PCB footprint, verify the physical lead arrangement against the manufacturer’s TO-5 pin configuration because the 8-terminal package is not interchangeable with standard 3-lead TO-92 devices. Input shielding, short analog traces, stable reference or excitation connections, and local supply decoupling help preserve the benefit of a precision fixed-gain amplifier. The input common-mode range and output-swing limits must be checked against the actual sensor and supply voltages.

This product page combines the manufacturer’s supply and gain information with practical guidance on signal conditioning, footprint selection, power architecture, and replacement sourcing. It also distinguishes the LT1101CH from other fixed-gain and adjustable-gain instrumentation amplifiers so engineers can choose a part that matches the required package, gain, supply voltage, and measurement precision.

드롭인 대체품: LT1101CH — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 제품에는 사용 가능한 드롭인 대체품이 없습니다.

대체품 요청

LT1101CH 최대 정격 & 전기적 특성

Product Type Precision micropower instrumentation amplifier
Fixed Gain 10 or 100
Number of Circuits 1 circuit
Single-Supply Operation 5 V
Dual-Supply Operation ±15 V
Lithium-Cell Operation 1 lithium cell
Ni-Cad Battery Operation 2 Ni-Cad batteries
패키지 8-terminal TO-5, round metal package
Terminal Count 8 terminals
Terminal Form Wire leads
Temperature Grade Commercial

LT1101CH 8-terminal to-5, round metal package 핀 구성 가이드

LT1101CH(8-terminal to-5, round metal package 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.

LT1101CH의 8-terminal to-5, round metal package 패키지 핀아웃 다이어그램

다음에 대한 상세 핀아웃 데이터 없음: LT1101CH.

다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.

일반적인 애플리케이션

LT1101CH 적합 용도: 6 애플리케이션s: Battery-Powered Sensor Interface, Biomedical Instrument Front End, Industrial Process Measurement, Portable Test and Measurement, Dual-Supply Laboratory Amplifier, Precision Bridge and Transducer Measurement.

🧩

Battery-Powered Sensor Interface

The LT1101CH suits portable sensor-conditioning circuits because the manufacturer classifies it as a micropower instrumentation amplifier and specifies operation from a single 5 V supply, one lithium cell, or two Ni-Cad batteries. A bridge, strain gauge, or other low-level differential sensor can feed the instrumentation amplifier, whose fixed gain of 10 or 100 amplifies the differential result while rejecting common-mode variation. Designers should verify the selected gain’s input common-mode range and output swing against the battery voltage, then include the manufacturer-recommended supply bypass and input-biasing arrangement. The main benefit is a compact signal chain without a separate fixed-gain stage, while the principal limitation is that changing sensitivity requires a different gain configuration or another amplifier.

💊

Biomedical Instrument Front End

The LT1101CH can serve as the differential input stage in battery-powered biomedical instrumentation when the selected gain of 10 or 100 matches the sensor output. The precision instrumentation-amplifier configuration is appropriate for small physiological or electrochemical signals, provided that the input common-mode voltage stays within the gain-specific limits and the output does not exceed the available swing. Low power is particularly important for devices worn for long periods or powered by limited battery capacity. The designer must account for patient-safety isolation, electrode protection, leakage, and noise filtering as separate system requirements; the amplifier’s precision characteristics alone do not establish medical compliance. Use the official pin description and single-supply reference configuration when defining the patient-connected front end.

🏭

Industrial Process Measurement

The LT1101CH is appropriate for low-level process signals when the equipment can use a fixed gain of 10 or 100 and can tolerate the 8-terminal TO-5 footprint. Pressure, temperature, and chemical sensor outputs can be amplified differentially to improve rejection of common-mode noise present on long industrial wiring. The circuit should use short connections from the sensor, guarded or shielded input routing where appropriate, and decoupling close to the supply pins. Verify the sensor excitation range against the amplifier’s allowable input and output voltages because a fixed gain does not provide input overvoltage protection. The TO-5 package also requires careful mechanical layout around the round body and wire leads, but it can be useful where a through-hole instrumentation solution is preferred over a fine-pitch surface-mount device.

🔧

Portable Test and Measurement

The LT1101CH fits portable instrumentation setups that need differential amplification from a single 5 V supply while maintaining a fixed, repeatable gain. It can condition outputs from pressure, current, or resistive sensors before conversion by an ADC or display system. The availability of gain-10 and gain-100 configurations allows the designer to match signal range without an adjustable resistor network, reducing setup ambiguity. Because the device is fixed-gain, measurement software should identify the selected version and account for that factor in calibration. Verify input offset, noise, and bandwidth in the manufacturer’s gain-specific tables, and keep the analog input path away from switching regulators and digital return currents to preserve the benefit of precision signal conditioning.

🖥️

Dual-Supply Laboratory Amplifier

The LT1101CH can be used in laboratory measurement systems operating from dual ±15 V supplies, where a fixed-gain differential stage simplifies the signal path. This arrangement is useful for bipolar sensor signals that would require additional level shifting in a single-supply design. The common-mode input and output-swing limits remain the primary design boundaries, so confirm them for the selected gain and load. Place input-referred shielding and bypass capacitors according to the manufacturer’s guidance, and avoid routing sensitive inputs beside high-energy or switching circuitry. Although the TO-5 package is larger than modern surface-mount instrumentation amplifiers, it remains practical for through-hole laboratory equipment where serviceability, leaded construction, and a straightforward mechanical footprint are useful priorities.

📈

Precision Bridge and Transducer Measurement

The LT1101CH can amplify differential outputs from resistive bridges and transducers when the excitation level and output span are compatible with gain-10 or gain-100 operation. Instrumentation-amplifier behavior helps reduce common-mode pickup from cables and nearby equipment, improving measurement repeatability. The fixed gain simplifies calibration and removes external gain-setting resistors, but it does not compensate for bridge imbalance, temperature drift, or excitation drift. Use a stable excitation source, limit cable length, and keep high-impedance input connections clean and short. Check whether the required bridge output remains within the gain-specific common-mode range throughout the full mechanical and electrical stimulus range rather than only at the nominal operating point.

What is the LT1101CH?
The LT1101CH is a precision, micropower, single-supply instrumentation amplifier manufactured by Analog Devices. According to the manufacturer datasheet, it provides fixed gain of 10 or 100 and operates from a single 5 V supply, a single lithium cell, two Ni-Cad batteries, or dual ±15 V supplies. The device is offered in an 8-terminal round TO-5 package for precision signal-conditioning applications.
What are the key specifications of LT1101CH?
The LT1101CH combines fixed gain of 10 or 100 with operation from 5 V single supply or ±15 V dual supply. The manufacturer datasheet identifies it as a precision, micropower instrumentation amplifier in an 8-terminal TO-5 package. Its common-mode input range, offset voltage, supply current, output swing, and bandwidth should be taken from the electrical-characteristics tables for the specific gain and supply configuration used in the circuit.
Where can I download the LT1101CH datasheet PDF?
The official LT1101 datasheet PDF is available from the Analog Devices technical-document website at https://www.analog.com/media/en/technical-documentation/data-sheets/lt1101fa.pdf. Use the manufacturer document for the complete electrical characteristics, supply-current behavior, gain options, common-mode limits, output swing, and recommended application circuits rather than relying on abbreviated distributor summaries.
Where can I find the LT1101CH pinout?
The LT1101CH pin configuration is documented in the pin-description section of the official Analog Devices LT1101 datasheet. The component uses an 8-terminal round TO-5 package with wire leads. Before assigning PCB tracks, compare the datasheet pin numbers with the physical lead orientation because a round metal package does not provide the pin-one marker familiar from most surface-mount ICs.
Can the LT1101CH operate from a single lithium cell?
Yes, the manufacturer datasheet states that the LT1101 can operate from a single lithium cell. This makes the LT1101CH appropriate for portable, battery-powered measurement systems when the sensor signal, supply level, and output range remain within the operating limits for the selected gain configuration. Two Ni-Cad batteries are also identified as an acceptable supply arrangement.
What is the difference between the gain-10 and gain-100 LT1101 versions?
The LT1101 family provides fixed-gain choices of 10 or 100, and the correct ordering code must be selected before layout. A gain of 10 preserves more of the original signal range and is useful when sensor outputs are relatively large, while gain of 100 increases sensitivity for small differential signals. The manufacturer datasheet’s gain tables should be used to verify offset, bandwidth, output swing, and supply-current differences.
When should I choose the LT1101CH over an adjustable-gain instrumentation amplifier?
Choose the LT1101CH when the measurement requires a stable fixed gain of 10 or 100 and the board can be dedicated to one input range. Its fixed-gain architecture simplifies the analog network and can reduce external resistor requirements. An adjustable-gain instrumentation amplifier is preferable when multiple ranges, calibration controls, or user-selectable gains are required, or when the sensor output can vary widely.
Is the LT1101CH suitable for battery-powered sensor interfaces?
Yes, the LT1101CH is suitable for battery-powered sensor interfaces because its manufacturer designation emphasizes micropower operation and the datasheet includes single 5 V, lithium-cell, and two-cell Ni-Cad supply configurations. The sensor excitation, signal polarity, input common-mode voltage, and required output span must be checked against the gain-specific electrical characteristics before the circuit is finalized.
What is the best drop-in replacement for the LT1101CH?
The best drop-in replacement must use the same 8-terminal TO-5 footprint, provide the same fixed gain, and satisfy the required supply-voltage, input-range, output-swing, bandwidth, and common-mode-rejection limits. The available cross-reference information identifies replacement relationships but does not expose complete candidate orderings or quantified comparisons. Use the Request a Quote form on this page for current sourcing assistance rather than treating a generic amplifier as a pin-compatible substitute.
What can replace LT1101CH in an instrumentation circuit?
A valid replacement for the LT1101CH should be a pin-compatible instrumentation amplifier in the same 8-terminal TO-5 package with fixed gain of 10 or 100. Merely offering a similar gain or low-power operation is insufficient because input bias current, offset, common-mode range, output swing, and bandwidth can invalidate the measurement. The replacement must also preserve the LT1101CH’s single- or dual-supply operating plan.
LT1101CH versus an adjustable-gain instrumentation amplifier: which is better?
The LT1101CH is better when one fixed gain of 10 or 100 is sufficient because it simplifies the feedback network and reduces calibration complexity. An adjustable-gain amplifier is better for variable-range sensors, selectable measurement channels, or systems where gain must change during operation. The trade-off is flexibility versus circuit simplicity: the LT1101CH cannot provide a user-programmable gain unless its output is followed by another amplifier stage.
How should the LT1101CH be used with a 5 V supply?
The LT1101CH can be operated from a single 5 V supply, but the sensor signal must remain inside the gain-specific input common-mode range and the required output must fit the available output swing. Follow the manufacturer’s single-supply application circuit, including input biasing and output-reference treatment where applicable. Check whether the measured signal crosses the output range as it approaches either supply rail.
Is the LT1101CH still active?
The manufacturer lists the LT1101 as an active product, and the LT1101CH remains identifiable in current distributor catalogs with a commercial temperature grade. Lifecycle status can change for individual order codes, so confirm the exact LT1101CH ordering suffix and availability through the Request a Quote form on this page before committing a production build.
Where can I buy the LT1101CH online?
The LT1101CH can be requested through the Request a Quote form on this page, where the exact MPN, quantity, and delivery requirements can be reviewed with XAIPART. Stock and lead time are not asserted statically because they change by lot and order volume. Provide your target quantity and required delivery date so the current supply position can be checked.
What is the price of the LT1101CH?
Use the Request a Quote form on this page for the current LT1101CH price and quantity-break review. Pricing depends on order quantity, package suffix, date, and current supply, so it is not embedded in the technical narrative. Include your required quantity, target lead time, and whether you need factory-sealed tubes or another authorized delivery format.
What is the lead time and stock status for the LT1101CH?
The current stock level and production lead time for LT1101CH should be confirmed through the Request a Quote form on this page. Availability can vary with order quantity, date, and manufacturing lead time, so neither in-stock status nor a fixed lead time is stated without a current quotation. Include your forecast quantities if you need planning support for multiple production releases.

엔지니어링 참조 데이터: LT1101CH — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the LT1101CH when the design requires a precision instrumentation amplifier with fixed gain of 10 or 100, low power consumption, and compatibility with single 5 V, lithium-cell, two-cell Ni-Cad, or dual ±15 V operation. It is especially useful when a fixed measurement range simplifies calibration and an 8-terminal TO-5 through-hole package is acceptable. Choose an adjustable-gain instrumentation amplifier when the sensor range must change during operation or multiple gain settings are needed. Choose a modern surface-mount precision instrumentation amplifier when board area, automated assembly, lower power, or a broader supply range is more important than the LT1101CH’s fixed-gain simplicity and leaded TO-5 format. Before ordering any replacement, require an identical package and pin arrangement, the same nominal fixed gain, and verified electrical performance at the intended supply voltage. Also confirm the operating temperature grade and whether the sensor can remain within the amplifier’s common-mode and output-swing limits.

대체품과의 비교

파라미터 이 제품
Product Type Precision micropower instrumentation amplifier
Fixed Gain 10 or 100
Single-Supply Operation 5 V
Dual-Supply Operation ±15 V
Battery Operation 1 lithium cell or 2 Ni-Cad batteries
Package 8-terminal TO-5
Brand Analog Devices
Temperature Grade Commercial
Number of Circuits 1 circuit
Mounting Form Through-hole wire leads

설계 노트

Use the official pin-description table when assigning tracks to the 8-terminal TO-5 package. A round metal package does not provide the obvious pin-one dot found on most molded ICs, so record the physical orientation and verify it again after board assembly. Keep differential inputs short, symmetrical, and away from switching nodes. Route the pair together over a continuous ground reference and place input-biasing or filtering components close to their associated amplifier pins.

Separate the LT1101CH signal path from high-current switching or relay return currents, and place supply bypass capacitors close to the device’s supply pins. For battery operation, check the minimum usable supply at the amplifier pins after accounting for cell variation, wiring resistance, and transient load steps. Verify the input common-mode range and output swing for the selected gain at every input and battery-voltage condition, especially when the output approaches either supply rail.

Do not treat an instrumentation amplifier with a similar gain as a drop-in substitute. A valid replacement must match the 8-terminal TO-5 pin arrangement and preserve the LT1101CH’s fixed gain, supply range, input bias current, common-mode limits, output swing, and bandwidth. Also confirm the commercial temperature-grade suffix and the exact gain configuration. Recheck calibration after any substitution because offset and gain error can differ even when the nominal gain is the same.

규정 준수 정보

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
무연
Unknown
무할로겐
Unknown
분쟁 광물
Unknown

No specific compliance declaration was identified for the LT1101CH ordering code. Confirm the current material and environmental declarations with Analog Devices before release to production.

관련 검색

LT1101CH datasheet LT1101CH datasheet pdf LT1101CH pinout LT1101CH TO-5 pinout LT1101CH specifications LT1101CH gain 10 LT1101CH gain 100 LT1101CH single supply LT1101CH replacement LT1101CH equivalent LT1101CH cross reference Analog Devices LT1101CH LT1101CH price LT1101CH stock

관련 부품 & 용어

Analog Devices LT1101 LT1101CH precision instrumentation amplifier instrumentation amplifier fixed-gain amplifier precision amplifier amplifier IC semiconductor single-supply operation dual-supply operation fixed gain differential input common-mode rejection micropower operation 5 V supply ±15 V supply lithium cell Ni-Cad battery TO-5 package 8-terminal package through-hole package sensor interface bridge measurement
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기