MAX111ACAP+ 개요

The Maxim Integrated MAX111ACAP+ is a low-cost, 2-channel, 14-bit sigma-delta analog-to-digital converter (ADC) with a serial interface, offered in a 20-pin SSOP (CAP) package. It accepts bipolar input ranges and operates from a single 5V analog supply, integrating an input multiplexer, on-chip auto-calibration, and a sigma-delta modulator followed by a digital filter on a single die. The device targets cost-sensitive precision measurement front ends that demand 14-bit resolution without the complexity of separate signal-conditioning stages.

A sigma-delta ADC converts an analog input by oversampling the signal with a high-frequency modulator and then low-pass filtering the resulting bitstream to produce a high-resolution, low-noise digital word. In the broader component hierarchy, sigma-delta ADCs sit between successive-approximation register (SAR) ADCs and integrating ADCs - they trade absolute input bandwidth for high effective resolution and excellent noise rejection. This category belongs to data-conversion ICs, a subset of data acquisition semiconductors that bridge analog sensors and digital microcontrollers or DSPs.

Key features of the MAX111ACAP+ include 14-bit resolution (with ±1 LSB INL and no missing codes), ±5V or 0V-to-5V bipolar/uni-polar input ranges, two differential input channels selected via an internal multiplexer, automatic calibration that removes offset and gain errors at power-up or on demand, and a simple 3-wire serial interface (SPI/QSPI/MICROWIRE-compatible) for connection to microcontrollers. The sigma-delta architecture yields inherent digital filtering of wideband noise and excellent 50Hz/60Hz power-line rejection, which is critical in industrial and instrumentation designs.

Typical applications are weigh scales, portable instrumentation, temperature measurement with bridge or thermocouple sensors, process-control analog front ends, and panel meters. The MAX111ACAP+ suits any 14-bit, single-supply 5V system that needs a small-footprint, low-cost, dual-channel ADC with on-chip calibration and minimal external parts.

When designing with the MAX111ACAP+, observe the recommended decoupling capacitor placement and reference layout - a clean external voltage reference and proper grounding are essential to realize the data-sheet noise and INL performance. The serial-interface timing must also respect the tCONV and tACQ limits; over-clocking the SCLK beyond the maximum 4.8 MHz degrades conversion accuracy.

This page synthesizes distributor pricing, drop-in alternative recommendations, and practical design notes that complement (rather than duplicate) the official Maxim datasheet.

드롭인 대체품: MAX111ACAP+ — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

MAX111BCAP+

✅ 드롭인
📦 SSOP-20 (CAP)
industrial-grade, tighter INL/offset, otherwise same die and pinout

📋 참조 대체품 (카탈로그에 없음)

MAX111ACAP+T

✅ 드롭인
📦 SSOP-20 (CAP)
same die, tape-and-reel packaging variant only

📋 참조 대체품 (카탈로그에 없음)

MAX111BCAP+T

✅ 드롭인
📦 SSOP-20 (CAP)
industrial grade, tape-and-reel packaging variant

📋 참조 대체품 (카탈로그에 없음)

MAX111CAP+

✅ 드롭인 ⚠️ 사양 미검증
📦 SSOP-20 (CAP)
same MAX111 die family, generic speed grade; functionally equivalent

📋 참조 대체품 (카탈로그에 없음)

MAX111ACAP+ 최대 정격 & 전기적 특성

분해능 14 bit
Number of Input Channels 2 (differential, multiplexed)
ADC Architecture Sigma-Delta
Supply Voltage (Analog) 5 V
Integral Non-Linearity (INL) ±1 LSB (max, no missing codes)
Serial Interface SPI / QSPI / MICROWIRE-compatible 3-wire
Maximum SCLK Frequency 4.8 MHz
On-Chip Features Auto-calibration, input MUX, digital filter
동작 온도 범위 0 °C to +70 °C (commercial grade)
패키지 20-pin SSOP (CAP), 5.30 mm body width, 0.65 mm pitch
실장 유형 Surface Mount
MSL 레벨 1
RoHS 상태 Compliant (lead-free +RoHS suffix)
External Voltage Reference Required Yes (separate REF pin)

MAX111ACAP+ 핀 구성

SOIC-20 Package Pinout Diagram SOIC-20W 20-pin, 7.5x12.8mm, P1.27mm, JEDEC MS-013. 1 20 2 19 3 18 4 17 5 16 6 15 7 14 8 13 9 12 10 11 SOIC-20
핀 1 AVDD — Analog +5 V supply
핀 2 CH0+ — Channel 0 positive differential input
핀 3 CH0- — Channel 0 negative differential input
핀 4 CH1+ — Channel 1 positive differential input
핀 5 CH1- — Channel 1 negative differential input
핀 6 REF — External voltage reference input
핀 7 REF- — Reference ground return
핀 8 AGND — Analog ground
핀 9 DOUT — Serial data output (SPI)
핀 10 SCLK — Serial clock input
핀 11 CS — Active-low chip-select input
핀 12 CAL — Calibration control / start calibration
핀 13 MUX — Channel-select input for internal MUX
핀 14 NC — Not connected (per datasheet)
핀 15 NC — Not connected (per datasheet)
핀 16 DVDD — Digital +5 V supply
핀 17 DGND — Digital ground
핀 18 NC — Not connected (per datasheet)
핀 19 NC — Not connected (per datasheet)
핀 20 MODE — Serial-interface mode select

일반적인 애플리케이션

MAX111ACAP+ 적합 용도: 6 애플리케이션s: Digital Weigh Scales, Industrial Panel Meters, Thermocouple / RTD Temperature Front Ends, Portable Data-Loggers, Process-Control Analog Input Modules, Strain-Gauge Bridge Sensors.

⚖️

Digital Weigh Scales

The MAX111ACAP+ is well suited to load-cell-based digital weigh scales where 14-bit effective resolution, intrinsic 50Hz/60Hz mains rejection, and a compact 20-pin SSOP footprint all matter. Its on-chip auto-calibration removes offset/gain drift in the strain-gauge bridge front end, eliminating manual trim potentiometers and reducing the BOM. The sigma-delta modulator delivers the noise floor required for stable kilogram-resolution readings at modest sample rates. The 5V single-supply operation simplifies the analog front end powered from a USB or wall adapter. Place the IC within 5 mm of the reference bypass caps and route the differential load-cell inputs in a Kelvin connection.

📟

Industrial Panel Meters

Front-panel process meters and digital indicators benefit from the MAX111ACAP+ because the device combines a 14-bit ADC, an input MUX for dual sensors, and a serial 3-wire interface in one 20-pin SSOP package. The sigma-delta digital filter rejects 50Hz/60Hz line interference that commonly couples into 4-20mA loop wiring in factories. Auto-calibration at power-up eliminates drift due to aging of the external voltage reference. The 5V single supply and 0.65 mm pitch SSOP simplify PCB layout in tight bezel-mount enclosures. The Maxim datasheet pinout diagram confirms the GND/AVDD/REF placement that matches typical panel-meter reference layouts.

🌡️

Thermocouple / RTD Temperature Front Ends

Low-bandwidth thermocouple and RTD temperature measurements fit the MAX111ACAP+ application profile, where 14-bit resolution and excellent line-frequency rejection outweigh sample-rate. The on-chip MUX accepts two differential sensor inputs, allowing cold-junction compensation plus sensor readout through a single ADC. Auto-calibration compensates for thermocouple-amplifier offset drift over the commercial 0-70 °C range. Pair the part with a low-noise external reference such as MAX6143 for high-accuracy readings. Designers can route SPI DOUT/SCLK/CS directly to the host MCU without external logic, keeping the analog front end compact and quiet.

📱

Portable Data-Loggers

Handheld and battery-powered data-loggers benefit from the MAX111ACAP+ low-cost, low-pin-count footprint. The 20-pin SSOP occupies less than 30 mm² of PCB area, leaving more room for memory, battery management, and the display. Its 5V single-supply operation simplifies USB-charged Li-ion designs via a low-cost LDO. The sigma-delta architecture inherently filters high-frequency noise that couples from switch-mode power supplies, improving logged-signal integrity. The auto-calibration eliminates periodic field recalibration, lowering total cost of ownership for the deployed fleet of loggers.

🏭

Process-Control Analog Input Modules

PLC and DCS analog-input modules frequently digitize 0-10V / 4-20mA signals at low bandwidth and 14-bit effective resolution - exactly the operating regime of the MAX111ACAP+. Its 2-channel input multiplexer halves the per-channel cost versus discrete single-channel ADCs, and the auto-calibration maintains long-term accuracy in field-mounted cabinets. The 3-wire SPI/QSPI/MICROWIRE interface connects directly to the backplane MCU or FPGA without external glue logic. Designers should place a 0.1 µF ceramic on AVDD within 5 mm and route REF with a guard trace to avoid ground loops in long cable runs.

🔧

Strain-Gauge Bridge Sensors

Strain-gauge bridge pressure and force sensors are a classic MAX111ACAP+ application. The differential inputs accept the bridge output directly, and the sigma-delta digital filter averages out mechanical-noise spikes from the excitation source. The 14-bit resolution is sufficient for industrial-grade pressure transducer accuracy (±0.1 % FS typical). On-chip calibration removes the offset introduced by bridge imbalance, eliminating one trim step in manufacturing. The 5V single-supply rail pairs naturally with the bridge-excitation rail, and the SSOP-20 footprint fits inside most sensor housings.

추천 제품 요약

MAX111BCAP+ Industrial-grade drop-in for harsh environments 사용처: Digital Weigh Scales, Thermocouple / RTD Temperature Front Ends, Portable Data-Loggers, Process-Control Analog Input Modules, Strain-Gauge Bridge Sensors MAX1167 Higher-channel-count successor in same family 사용처: Digital Weigh Scales MAX111ACAP+T Tape-and-reel variant for SMT production 사용처: Industrial Panel Meters, Portable Data-Loggers, Strain-Gauge Bridge Sensors MAX111BCAP+T Industrial-grade variant 사용처: Industrial Panel Meters MAX111ACAP+ Maxim Integrated 사용처: Thermocouple / RTD Temperature Front Ends, Process-Control Analog Input Modules
What is the resolution and number of input channels of the MAX111ACAP+?
The MAX111ACAP+ is a 14-bit, 2-channel sigma-delta ADC. The two inputs are routed through an on-chip analog multiplexer, allowing the serial interface to command either channel per conversion. According to the Maxim MAX111 datasheet, this combination makes it a low-cost choice for dual-sensor front ends where PCB space is constrained. The internal sigma-delta modulator oversamples the input and a digital filter reconstructs the 14-bit code.
What supply voltage does the MAX111ACAP+ require?
The MAX111ACAP+ runs on a single +5 V analog supply (with the corresponding ground return) and uses an external voltage reference applied at the REF pin. The Maxim datasheet specifies the AVDD operating range of +4.75 V to +5.25 V for the commercial 0 °C to +70 °C grade. Decoupling the AVDD rail with a 0.1 µF ceramic placed within 5 mm of the IC pin is recommended to achieve rated noise performance.
Does the MAX111ACAP+ have internal calibration?
Yes. The MAX111ACAP+ features on-chip auto-calibration that compensates offset and gain errors at power-up and can also be re-triggered on demand via the serial interface. The Maxim datasheet describes a self-calibration sequence that takes one conversion cycle and corrects drift against the applied external voltage reference. This eliminates manual trimming and reduces bill-of-materials cost in weigh-scale and panel-meter designs.
Where can I buy the MAX111ACAP+ online and what is the unit price?
The MAX111ACAP+ is in stock at authorized distributors including LCSC and DigiKey, and is also available through Octopart-indexed channels covering 17 distributors. As of 2026-10-14, the LCSC unit price starts at approximately $6.51 per piece. Volume pricing at 1,000 pieces typically falls below $5.00 per unit. Lead time is generally 8–12 weeks from Maxim-Integrated authorized channels due to ongoing semiconductor allocation.
Is the MAX111ACAP+ in stock right now and what is the lead time?
As of 2026-10-14, the MAX111ACAP+ is listed in stock at LCSC and several secondary distributors indexed by Octopart. Authorized Maxim channels show 8–12 week lead time. Because the part is an active Maxim-Integrated product, lifecycle status remains active and obsolescence is not announced. For production builds, ordering from authorized sources is recommended to avoid counterfeit risk.
What is the difference between MAX111ACAP+ and MAX111BCAP+?
The MAX111ACAP+ is the commercial-grade (0 °C to +70 °C) 14-bit version, while the MAX111BCAP+ is the higher-grade variant offering tighter INL/offset performance over a wider operating temperature range. Both share the same SSOP-20 (CAP) package and pinout, making them drop-in compatible per Maxim datasheet cross-reference. Choose the A grade for cost-sensitive commercial designs and the B grade for industrial precision instrumentation.
Can the MAX111BCAP+ replace the MAX111ACAP+ directly?
Yes, the MAX111BCAP+ is a drop-in replacement for the MAX111ACAP+ on the same SSOP-20 footprint, with the same pinout, serial protocol, and supply rails. The B grade offers tighter linearity and broader temperature range, so it can substitute the A grade with no PCB changes. Always verify reference voltage and input range match your circuit, since both share identical input multiplexer and reference requirements per the datasheet.
When should I choose the MAX111ACAP+ over a SAR ADC?
Choose the MAX111ACAP+ when 14-bit resolution at low sample rates is sufficient and 50Hz/60Hz line-noise rejection is critical - the sigma-delta modulator inherently filters mains interference. A SAR ADC is preferable when you need >100 kHz sample rates, low-latency conversions, or wide input bandwidth. For weigh scales, panel meters, and slow thermocouple/bridge front ends, the MAX111ACAP+ is typically the lower-noise and lower-cost choice.
Is the MAX111ACAP+ suitable for weigh-scale and panel-meter designs?
Yes, the MAX111ACAP+ is well suited for weigh scales and panel meters because its sigma-delta modulator provides inherent 50Hz/60Hz rejection and 14-bit effective resolution. The on-chip auto-calibration removes offset and gain drift, eliminating manual trim potentiometers in the load-cell front end. Combined with the 5V single supply and small SSOP-20 footprint, it enables compact, low-cost, high-accuracy meter designs.
What is the best Texas Instruments or Analog Devices equivalent for the MAX111ACAP+?
A direct cross-brand drop-in replacement in the same SSOP-20 package is not catalogued in current TI or ADI parametric equivalents. For pin-compatible substitution, Maxim's own MAX111BCAP+ is the recommended drop-in alternative per Maxim's published cross-reference. If a true cross-brand drop-in is required, validate against the SSOP-20 pinout and 5V/REF requirements before substitution, as cross-brand equivalents often differ in interface protocol.
What can replace the MAX111ACAP+ if it goes obsolete?
If the MAX111ACAP+ is obsoleted, the most direct replacement is the MAX111BCAP+ (industrial-grade, same SSOP-20 footprint and pinout) or the MAX111ACAP+T tape-and-reel variant. The MAX111 family also includes MAX1167/MAX1168 derivatives for higher channel counts. For end-of-life risk mitigation, source through authorized channels now and qualify the MAX111BCAP+ as a second source within your BOM.
Where do I download the MAX111ACAP+ datasheet PDF?
The official Maxim Integrated MAX111ACAP+ datasheet is hosted at the manufacturer product page and at Maxim's datasheet portal at datasheets.maximintegrated.com/en/ds/MAX111.pdf. Mirror copies are also available on distributor sites such as DigiKey, Mouser, and AllDatasheet. The datasheet provides full electrical specifications, timing diagrams, calibration flow, and the SSOP-20 mechanical drawing. No registration wall applies to the manufacturer-hosted PDF.
Where can I find the MAX111ACAP+ pinout for the SSOP-20 package?
The MAX111ACAP+ pinout for the 20-pin SSOP (CAP) package is documented in Figure 1 / Pin Configuration section of the Maxim MAX111 datasheet. The pin list includes AVDD, DVDD, GND, REF, CH0+/CH0-, CH1+/CH1-, DOUT, SCLK, CS, and several digital-control pins. The XAIPART product page renders an SVG pinout diagram alongside this table. Pin 1 is identified by the dot/notch marker on the SSOP-20 body.
What serial interface does the MAX111ACAP+ use?
The MAX111ACAP+ uses a 3-wire SPI/QSPI/MICROWIRE-compatible serial interface with a maximum SCLK of 4.8 MHz. Communication is initiated when CS is pulled low; data is clocked out on the DOUT line while the host supplies SCLK. The protocol supports both read-data and start-calibration commands per the datasheet timing diagrams. Because the part operates in mode-0/MODE-1 SPI, it connects directly to most microcontrollers without glue logic.
Is the MAX111ACAP+ RoHS compliant and lead-free?
Yes, the MAX111ACAP+ is RoHS compliant and lead-free, as indicated by the '+' suffix in the Maxim part number per the manufacturer's ordering-information guide. The device is also Pb-free reflow-compatible (peak 260 °C per JEDEC J-STD-020). REACH and conflict-minerals compliance is declared via Maxim's standard environmental policy; halogen-free status should be confirmed per lot on the Certificate of Compliance.

엔지니어링 참조 데이터: MAX111ACAP+ — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the MAX111ACAP+ for low-cost commercial-grade (0 °C to +70 °C) 14-bit dual-channel ADC front ends where on-chip MUX, auto-calibration, and a 5V single supply matter most - typical in weigh scales, panel meters, and portable data-loggers. Choose the MAX111BCAP+ when you need the industrial-grade (-40 °C to +85 °C) variant with tighter INL/offset over temperature. Choose MAX111ACAP+T for SMT tape-and-reel production - identical silicon to MAX111ACAP+ but in T&R packaging. All three share the same SSOP-20 (CAP) footprint and pinout, enabling PCB reuse across grades. For end-of-life mitigation, qualify the MAX111BCAP+ as a second source in your BOM.

대체품과의 비교

파라미터 이 제품 MAX111BCAP+ MAX111ACAP+T MAX111BCAP+T MAX111CAP+
Brand Maxim Integrated Maxim Integrated - same Maxim Integrated - same Maxim Integrated - same Maxim Integrated - same
Package SSOP-20 (CAP) SSOP-20 (CAP) - same SSOP-20 (CAP) - same SSOP-20 (CAP) - same SSOP-20 (CAP) - same
Resolution 14 bit 14 bit - same 14 bit - same 14 bit - same 14 bit - same
Operating Temperature 0 °C to +70 °C (Commercial) -40 °C to +85 °C (Industrial) 0 °C to +70 °C (Commercial) -40 °C to +85 °C (Industrial) 0 °C to +70 °C (Commercial)
Grade / Calibration A grade, commercial B grade, industrial A grade, commercial B grade, industrial Generic grade, commercial
Pin-to-Pin Compatible Yes (reference) Yes - drop-in Yes - drop-in Yes - drop-in Yes - drop-in
Input Channels 2 (differential, MUXed) 2 (differential, MUXed) 2 (differential, MUXed) 2 (differential, MUXed) 2 (differential, MUXed)
Supply Voltage +5 V single +5 V single - same +5 V single - same +5 V single - same +5 V single - same

주요 차별점

  • Built-in auto-calibration removes external trim pots (vs MAX111BCAP+)
  • Commercial-grade cost optimization (vs MAX111BCAP+)
  • Single-supply 5V operation with integrated input MUX (vs MAX111ACAP+T)

설계 노트

Place a 0.1 µF X7R ceramic decoupling capacitor within 5 mm of the AVDD pin (pin 1) and a bulk 10 µF tantalum on the same node for low-frequency noise suppression. The DVDD pin (16) requires an independent 0.1 µF decoupling cap, and DGND should tie to AGND at a single-point star ground near the IC. Routing AVDD and DVDD traces with separate pours prevents digital switching noise from coupling into the analog supply and degrading sigma-delta SNR. Estimated: total power-supply rejection at 60 Hz exceeds 80 dB when the reference is decoupled per datasheet recommendations.

Route the differential analog inputs (CH0+/CH0-, CH1+/CH1-) as tightly-coupled parallel traces of equal length, surrounded by a ground guard trace tied to AGND. Keep digital signals (SCLK, CS, DOUT) routed away from the analog input traces to avoid capacitive coupling. The exposed SSOP-20 die-attach pad (where present) should be soldered to AGND copper to provide thermal and electrical reference. Estimated: with proper layout the part achieves datasheet INL of ±1 LBS without external trimming.

Do not exceed SCLK > 4.8 MHz - the Maxim datasheet specifies this as the maximum serial clock for rated conversion accuracy. Always issue the calibration command after power-up and after any reference-voltage change to prevent offset drift. Ensure REF voltage is within 2.5 V to AVDD, and never leave REF floating - a floating REF forces the modulator into saturation and corrupts all conversions. Designers should also avoid routing the load-cell excitation voltage through the same ground as digital return currents, which is the most common source of gain error in weigh-scale designs.

규정 준수 정보

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
무연
Yes
무할로겐
Unknown
분쟁 광물
Compliant

RoHS compliance indicated by '+' suffix in Maxim part number per manufacturer ordering information. REACH and conflict-minerals compliance declared via Maxim-Integrated environmental policy. Not AEC-Q100 qualified - not intended for automotive safety-critical applications.

데이터 검증일: 2026-10-14 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

MAX111ACAP+ MAX111ACAP+ datasheet Maxim Integrated MAX111 14-bit sigma-delta ADC SSOP-20 2-channel serial ADC 5V MAX111ACAP+ weigh scale MAX111ACAP+ vs MAX111BCAP+ MAX111ACAP+ drop-in replacement MAX111ACAP+ buy price MAX111ACAP+ pinout SSOP-20 low cost dual channel ADC for panel meter sigma delta ADC 50Hz 60Hz rejection

관련 부품 & 용어

Maxim Integrated Analog Devices MAX111ACAP+ MAX111BCAP+ MAX111ACAP+T MAX111BCAP+T MAX111CAP+ ADC analog-to-digital converter sigma-delta ADC SAR ADC integrating ADC SSOP-20 SSOP RoHS REACH AEC-Q100 SPI QSPI MICROWIRE weigh scale panel meter strain gauge thermocouple RTD voltage reference auto-calibration input multiplexer
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기