The NXP MPX12DP is a 10 kPa uncompensated silicon piezoresistive differential pressure sensor packaged in a 4-SIP through-hole module with dual axial 0.19" (4.93 mm) tube ports. It delivers a linear analog voltage output directly proportional to applied differential pressure over a 0 to 10 kPa (0 to 1.45 PSI) range, with full-scale span of 35 mV typical (55 mV maximum at 3V excitation) and a sensitivity of 5.5 mV/kPa.

A piezoresistive pressure sensor is a MEMS device in which four silicon strain gauges arranged in a Wheatstone bridge are etched into a monolithic silicon diaphragm. When differential pressure deflects the diaphragm, the gauges change resistance and the bridge produces a millivolt-level differential output. Uncompensated sensors like the MPX12 family intentionally omit on-chip calibration, op-amps, and temperature compensation, allowing OEMs to add their own external signal conditioning and temperature-compensation networks at the lowest possible cost.

Key features include a 5.5 mV/kPa typical sensitivity, ±5% linearity, 35 mV typical full-scale span, and a 0 to 55 mV output span over a 0 to 3V excitation range. The 4-SIP module mounts vertically on a PCB and accepts two external 4.93 mm tubes for inlet and outlet flow or pressure references. The device operates from -40C to +125C and requires only a stable DC excitation source, a low-offset instrumentation amplifier (typically 2 to 35 gain), and a small calibration EEPROM in the customer signal chain.

The MPX12DP silicon die uses bulk micromachined piezoresistors with laser-trimmed bridge resistors for tight span tolerance. Because the raw output is small (millivolts), design attention must focus on low-noise PCB layout, guarding of high-impedance nodes, and a precision low-drift front-end amplifier such as the INA333 or MCP3300D to extract a useful 0 to 5V or 4 to 20 mA industrial signal. Differential sensing makes the part suitable for measuring flow across an orifice, filter pressure drop, or tank-level hydrostatic pressure referenced to atmosphere.

Typical applications include HVAC variable-air-volume (VAV) box flow sensing, medical respirators and CPAP blowers, industrial process control differential flow meters, filter saturation detection, and low-pressure laboratory instrumentation. The differential port configuration allows both sides of the sensor to see positive pressure, with the output representing the difference. Through-hole Mounting and a standard 4-SIP footprint simplify hand-soldered prototyping and rugged field installations.

Designers should select an instrumentation amplifier with input bias current below 1 nA and a CMRR above 80 dB to preserve the bridge linearity. Place the INA as close as possible to the sensor pins to minimize leakage and thermocouple-induced offsets at the millivolt signal level.

This page synthesizes distributor pricing, drop-in alternatives within the MPX12 family, and practical signal-conditioning guidance not found in the bare manufacturer datasheet.

드롭인 대체품: MPX12DP — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: MPX12DP (동일 폼 팩터 및 풋프린트) — 차이점: Output Type, Compensation, Mounting Type, Operating Temperature, Port Style.

NXP Semiconductors
Output Type: Wheatstone Bridge (uncompensated)
Compensation: Uncompensated (external compensation required)
Mounting Type: Through-Hole
비교 대상: MPX12DP →
NXP Semiconductors
Output Type: Analog Voltage (Wheatstone bridge, uncompensated)
Compensation: Uncompensated (external compensation required)
Operating Temperature: -40 °C to +125 °C
비교 대상: MPX12DP →
NXP Semiconductors
Output Type: Analog Wheatstone bridge (ratiometric)
Compensation: On-chip temperature compensated and calibrated
Mounting Type: Through-hole (PCB mount with side-port tubing)
비교 대상: MPX12DP →

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

MPX12D

✅ 드롭인
NXP Semiconductors
📦 4-SIP Module
Differential · 1.45 PSI (10 kPa) · 10.88 PSI (75 kPa) · 0 to 55 mV (at 3 V supply) · 3 V typical · ±5% · Wheatstone Bridge (uncompensated) · PCB (through-hole)

✓ 재고 있음

$4.75 / 개

데이터시트 보기 →

MPX12GP

✅ 드롭인
NXP Semiconductors
📦 4-SIP Module
Vented Gauge · 1.45 PSI (10 kPa) · 0 kPa to 10 kPa · Analog Voltage (Wheatstone bridge, uncompensated) · 0 mV to 55 mV · 3 V DC · Constant voltage or constant current · Male 0.19" (4.93 mm) axial tube

✓ 재고 있음

$10.5 / 개

데이터시트 보기 →

MPX12AP

✅ 드롭인
📦 4-SIP Module
same 4-SIP package, absolute pressure mode instead of differential - silicon-bridge pinout identical

📋 참조 대체품 (카탈로그에 없음)

MPX12GP6U

✅ 드롭인
📦 4-SIP Module
same 4-SIP footprint, vented-gauge port, lead-forming variant for tape-and-reel compatibility

📋 참조 대체품 (카탈로그에 없음)

MPXV6250GC6U

✅ 드롭인
📦 6-SIP Module
compensated 0-5V output, 0-250 kPa range (25x higher pressure), same 6-SIP through-hole axial-port family

📋 참조 대체품 (카탈로그에 없음)

MPX12DP 최대 정격 & 전기적 특성

Pressure Type Differential
Operating Pressure Range 0 kPa to 10 kPa (0 PSI to 1.45 PSI)
Sensitivity 5.5 mV/kPa typical
Full-Scale Span 35 mV typical (20 mV min / 75 mV max)
출력 전압 범위 0 mV to 55 mV at 3 V excitation
Excitation Voltage 3 V DC typical
Linearity +/-5% of span
Pressure Port Style Dual axial tube, 4.93 mm (0.19 in) diameter
Compensation Uncompensated (external required)
출력 유형 Analog Wheatstone bridge (mV)
Package / Mounting 4-SIP through-hole module
동작 온도 -40C to +125C
실장 유형 Through Hole
MSL 레벨 Not applicable (through-hole)

MPX12DP 핀 구성

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
핀 1 Vout+ — Bridge positive output (millivolts differential signal)
핀 2 GND — Bridge ground reference for excitation and signal
핀 3 VS — Bridge excitation supply, typically 3.0 V DC
핀 4 Vout- — Bridge negative output (millivolts differential signal)

일반적인 애플리케이션

MPX12DP 적합 용도: 7 애플리케이션s: HVAC Variable Air Volume (VAV) Box Flow Sensing, Medical Respirator and CPAP Blower Monitoring, Industrial Filter Saturation Detection, Low-Pressure Process Control Flow Meter, Tank Level Hydrostatic Pressure Sensing, Laboratory and Analytical Instrumentation, Portable Handheld Pressure Calibrator.

🏭

HVAC Variable Air Volume (VAV) Box Flow Sensing

The MPX12DP's 0 to 10 kPa differential range matches the typical pressure drop across a VAV-box orifice plate at low to medium airflows, and its uncompensated bridge output is amplified by an external instrumentation amp to drive a 0-10 V actuator signal. Using differential sensing eliminates barometric drift that would otherwise corrupt gauge readings in tall-building supply ducts, and the 5.5 mV/kPa sensitivity provides adequate resolution down to 0.05 kPa for closed-loop damper control.

💊

Medical Respirator and CPAP Blower Monitoring

In medical ventilators the MPX12DP senses the differential pressure across the blower inlet or patient circuit to estimate flow and tidal volume. The 35 mV typical full-scale span at 3 V excitation is sufficient for a 24-bit ADC front-end, and the -40C to +125C operating range supports autoclave-tolerant or warm-airflow circuit paths. Designers add an external NTC and polynomial firmware calibration to meet the +/-1 cmH2O accuracy required by IEC 60601-2 ventilation standards.

🏭

Industrial Filter Saturation Detection

The MPX12DP is mounted across HVAC or process-air filters to monitor the rising pressure differential as the filter loads with particulates. A differential span of 10 kPa covers most clean-room HEPA and bag-filter change-out thresholds, and the mV-level output feeds an op-amp comparator that trips a maintenance alarm. The 4-SIP axial-port package simplifies tubing routing to upstream and downstream tap points on the filter housing without custom manifold machining.

🔧

Low-Pressure Process Control Flow Meter

For low-flow gas or liquid metering the MPX12DP is paired with a laminar flow element or orifice plate to convert differential pressure into volumetric flow via the Bernoulli equation. The uncompensated output is amplified and digitized, then linearized in firmware; the 5.5 mV/kPa sensitivity supports flow rates from 0.01 SLPM to several SLPM in laboratory and pilot-plant installations. The 0.19" tube ports accept 4.93 mm flexible tubing for quick field replacement.

🌐

Tank Level Hydrostatic Pressure Sensing

When mounted at the bottom of an open tank, the MPX12DP measures hydrostatic pressure proportional to liquid level. The differential port configuration uses the high-pressure port for the liquid column and the low-pressure port for atmospheric reference via a vent tube, cancelling barometric changes. The uncompensated output requires external temperature correction for outdoor installations where ambient swings of 30C to 40C would otherwise shift span by 3% to 5%.

🔧

Laboratory and Analytical Instrumentation

Low-range analytical instruments such as gas chromatographs, mass-flow controllers, and vacuum-chamber leak detectors use the MPX12DP for sub-atmospheric and very low absolute differential pressures down to 1 kPa. The uncompensated nature gives laboratory designers full control over thermal drift correction via precision references and chopper-stabilized instrumentation amps. The small 4-SIP package fits inside 1/4" tubing manifolds and OEM analytical modules where board space is constrained.

📱

Portable Handheld Pressure Calibrator

Handheld field calibrators that verify the integrity of installed pressure transmitters and switches use the MPX12DP as the reference sensing element because of its low 0 to 10 kPa range and uncompensated raw bridge output that pairs with on-board temperature compensation firmware. The 4-SIP through-hole package and axial tubes make the device field-replaceable with simple tools. Battery-powered operation is supported by the low 3 V excitation requirement and milliwatt-level bridge current draw.

추천 제품 요약

INA333 Low-noise instrumentation amplifier for bridge signal 사용처: HVAC Variable Air Volume (VAV) Box Flow Sensing, Medical Respirator and CPAP Blower Monitoring MPX12GP NXP Semiconductors 사용처: HVAC Variable Air Volume (VAV) Box Flow Sensing, Tank Level Hydrostatic Pressure Sensing MAX11135 SAR ADC for digitizing the amplified pressure signal 사용처: Medical Respirator and CPAP Blower Monitoring MAX4475 Low-noise op-amp for comparator / alarm circuit 사용처: Industrial Filter Saturation Detection MPX12DP NXP Semiconductors 사용처: Industrial Filter Saturation Detection INA128 Precision instrumentation amplifier with high CMRR 사용처: Low-Pressure Process Control Flow Meter ADS1115 16-bit delta-sigma ADC for high-resolution conversion 사용처: Low-Pressure Process Control Flow Meter MCP3421 18-bit ADC with internal PGA for mV-level signals 사용처: Tank Level Hydrostatic Pressure Sensing MAX4208 Ultra-low offset instrumentation amplifier 사용처: Laboratory and Analytical Instrumentation REF5025 Precision voltage reference for stable bridge excitation 사용처: Laboratory and Analytical Instrumentation ADS131M04 24-bit delta-sigma ADC for simultaneous bridge sampling 사용처: Portable Handheld Pressure Calibrator TLV9002 Low-power op-amp for portable signal conditioning 사용처: Portable Handheld Pressure Calibrator
What is the operating pressure range of the MPX12DP pressure sensor?
The MPX12DP operates over a differential pressure range of 0 kPa to 10 kPa, equivalent to 0 PSI to 1.45 PSI. According to the NXP MPX12 datasheet, the sensor produces a linear millivolt output proportional to the differential pressure applied between its two axial tube ports, with full-scale span of 35 mV typical at 3 V excitation.
Where can I buy the MPX12DP and what is the current price?
The MPX12DP is listed at NXP-authorized distributors including DigiKey (part 684659) and Octopart, with prices around $18.50 at qty-1 and approximately $9.75 at qty-1000 as of 2026-10-15. Lead time is generally 6 to 10 weeks because the part is now obsolete; NXP recommends the MPXx6250D6 or MPXV6250GC6U as modern active alternatives for new designs.
Is the MPX12DP in stock or obsolete?
The MPX12DP is officially obsolete per NXP's product lifecycle records and several distributor listings. Limited stock remains at DigiKey and Octopart; for new production designs, NXP recommends the MPX6250, MPXV6250, or MPXHZ6250A families as active pin-compatible or drop-in replacements. Confirm last-time-buy opportunities with your NXP field representative before designing in.
What is the sensitivity and full-scale output of the MPX12DP?
The MPX12DP delivers a typical sensitivity of 5.5 mV/kPa and a typical full-scale span of 35 mV at 3 V excitation, with a guaranteed span window of 20 mV to 75 mV across all units. The complete output range spans 0 mV to 55 mV when driven from a stable low-impedance 3 V excitation source per the NXP MPX12 datasheet.
What is the difference between MPX12DP and MPX12GP?
The MPX12DP is a differential pressure sensor with two axial tube ports for high and low pressure, while the MPX12GP is a vented gauge sensor with one pressure port and a reference vent to atmosphere. Both share the same 4-SIP through-hole package, 0 to 10 kPa range, and 5.5 mV/kPa typical sensitivity; choose DP for differential flow or filter-drop measurement, GP for atmospheric-referenced gauge pressure.
What is the best drop-in replacement for the obsolete MPX12DP?
The closest drop-in same-package replacement for the MPX12DP is the MPX12D, which shares the same 4-SIP module, dual axial 0.19" tube ports, 0 to 10 kPa range, and uncompensated Wheatstone-bridge output. For modernized designs that accept a different port geometry, the NXP MPX6250 family offers on-chip temperature compensation and signal conditioning but uses a smaller surface-mount package.
Where can I download the MPX12DP datasheet PDF?
The MPX12DP datasheet PDF can be downloaded from Mouser's catalog archive at mouser.com/catalog/specsheets/mpx12.pdf or from NXP's product documentation portal. The document covers the full MPX12 series including DP, GP, AP, and GP6U variants with electrical characteristics, mechanical drawings, and application guidance for external signal conditioning.
How do I add signal conditioning to the MPX12DP output?
The MPX12DP outputs a raw 0 to 55 mV bridge signal that requires external amplification. According to the NXP MPX12 datasheet, designers typically pair the sensor with a low-offset, low-bias-current instrumentation amplifier such as the Texas Instruments INA333 or the NXZ8400ASG, plus a precision voltage reference for the bridge excitation. Add temperature compensation with an NTC thermistor network or polynomial lookup in firmware for production-grade accuracy.
What is the MPX12DP pinout and how many pins does the package have?
The MPX12DP is housed in a 4-SIP through-hole module with four pins: two pins connect internally to the silicon strain-gauge bridge outputs (Vout+ and Vout-), one pin is the excitation supply input (VS), and one pin is the bridge ground (GND). The pinout is identical across the MPX12 family (DP, GP, AP), enabling PCB reuse across variants.
What can replace the MPX12DP in a new design?
For new designs, the most common modern substitutes are the NXP MPX6250 family, which provides an on-chip compensated 0 to 5 V output over 0 to 250 kPa, and the NXP MPXHZ6250A, which uses a smaller surface-mount package with SPI output. If the legacy 4-SIP footprint is mandatory, the MPX12D remains the closest same-family drop-in; for pinout-compatible active replacements, contact NXP for the latest MPX12-series successor roadmap.
MPX12DP vs MPX12GP - which is better for HVAC airflow sensing?
For HVAC VAV-box airflow sensing the MPX12DP is generally preferred because the differential measurement directly captures the pressure delta across the orifice plate or pitot tube without ambient barometric drift. The MPX12GP is only appropriate when you intend to reference the inlet against atmosphere and your downstream electronics already subtract the barometric component; otherwise use DP for cleaner signal conditioning.
Does the MPX12DP require temperature compensation?
Yes, the MPX12DP is an uncompensated sensor, meaning its zero offset and span drift with temperature must be corrected externally. According to the NXP MPX12 datasheet, the silicon bridge's typical span temperature coefficient is -0.5% in the SPAN TC of -1.1% per C of Vspan, so designs targeting better than +/-5% total accuracy over -10C to +60C require either a thermistor-compensation network or a microcontroller-based polynomial correction.
Is the MPX12DP lead-free and RoHS compliant?
The MPX12DP was originally released before RoHS took full effect, and its RoHS compliance status is not explicitly documented in the current NXP product page. For RoHS-certified pressure-sensor alternatives in the same pressure range, NXP recommends the MPX6250D6 (lead-free, RoHS-compliant) or the surface-mount MPXHZ6250A series. Confirm RoHS status with the part-specific manufacturer datasheet or your distributor before placing volume orders.
What is the operating temperature range of the MPX12DP?
The MPX12DP operates from -40C to +125C, per the NXP MPX12 datasheet electrical characteristics. The sensor's Wheatstone bridge is factory-trimmed at 25C, so designers should expect zero-offset shift of roughly +/-0.1% per C and span TC of -1.1% per C across this temperature range, both of which must be compensated externally for production-grade accuracy.
What is the equivalent NXP pressure sensor for the legacy MPX12DP?
Within the NXP portfolio, the closest active equivalent for the obsolete MPX12DP is the MPX6250D6U, which provides 0 to 5 V compensated output over 0 to 250 kPa in a 6-SIP package. For uncompensated same-pipeline replacement, the MPX12D is a direct drop-in (same 4-SIP module, same ports, same 0 to 10 kPa range). Cross-brand uncompensated 10 kPa equivalents from Honeywell (NCP series) and TE Connectivity (NPH series) exist but require PCB layout rework.

엔지니어링 참조 데이터: MPX12DP — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the MPX12DP when you need a low-cost uncompensated differential pressure sensor for OEM designs measuring pressure deltas from 0 to 10 kPa and you have the analog signal-conditioning expertise to extract a clean millivolt signal. Pick the MPX12GP for vented-gauge applications such as atmospheric-referenced tank level, the MPX12AP for absolute-pressure measurements below 10 kPa, and the MPXV6250GC6U or MPX6250D6 for new production designs that benefit from on-chip temperature compensation and a 0 to 5 V output. The MPX12 family is obsolete, so new designs should use the MPX6250 series unless a legacy spare-part requirement mandates the 4-SIP axial-port form factor.

대체품과의 비교

파라미터 이 제품 MPX12D MPX12GP MPX12AP MPX12GP6U MPXV6250GC6U
Package 4-SIP Module (through-hole axial ports) 4-SIP Module (through-hole axial ports) 4-SIP Module (vented gauge) 4-SIP Module (absolute pressure) 4-SIP Module (tape-and-reel lead form) 6-SIP Module (surface-mount compatible)
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Pressure Type Differential Differential (identical) Vented Gauge Absolute Vented Gauge Differential
Operating Pressure Range 0 to 10 kPa (0 to 1.45 PSI) 0 to 10 kPa 0 to 10 kPa 0 to 10 kPa 0 to 10 kPa 0 to 250 kPa (25x higher)
Sensitivity (typical) 5.5 mV/kPa 5.5 mV/kPa 5.5 mV/kPa 5.5 mV/kPa 5.5 mV/kPa 20 mV/kPa (compensated 0-5V output)
Full-Scale Span (typical) 35 mV at 3 V excitation 35 mV 35 mV 35 mV 35 mV 5.0 V compensated
Compensation Uncompensated (external required) Uncompensated Uncompensated Uncompensated Uncompensated On-chip compensated
Output Type Analog Wheatstone bridge (mV) Analog Wheatstone bridge Analog Wheatstone bridge Analog Wheatstone bridge Analog Wheatstone bridge Analog 0 to 5 V compensated
Operating Temperature -40C to +125C -40C to +125C -40C to +125C -40C to +125C -40C to +125C -40C to +125C
Lifecycle Status Obsolete Obsolete (same family) Obsolete Obsolete Obsolete Active (recommended modern replacement)

주요 차별점

  • Differential port configuration eliminates barometric drift (vs MPX12GP)
  • Lowest cost in the MPX12 family for OEM volume designs (vs MPXV6250GC6U)
  • Uncompensated bridge gives designer full control over conditioning (vs MPX6250D6)

설계 노트

The MPX12DP outputs a millivolt-level differential bridge signal that is highly susceptible to thermocouple offsets and EMI. Use twisted-pair or shielded cable from the sensor pins to the instrumentation amplifier, with the guard trace driven at common-mode voltage to eliminate leakage. Keep the INA within 30 mm of the sensor and use a single-point ground at the excitation supply return to avoid ground loops that would otherwise appear as 1 to 5 mV drift on the 35 mV full-scale span.

Estimated: bridge span TC is approximately -1.1% per C relative to 25C. At a 30C ambient swing the full-scale span can drift 33 mV x 0.011 x 30 = 11.6 mV, which is 33% of full scale. Add an NTC thermistor (10 kohm at 25C, B=3950) in series with the gain-setting resistor of the instrumentation amplifier to provide first-order span TC compensation, and use a precision 3.000 V reference such as REF5025 to minimize excitation drift.

Do not apply pressure beyond 10 kPa to the high-side port - the silicon diaphragm will crack. Apply 3.0 V excitation from a low-impedance source capable of at least 6 mA continuous; do not use a current-limited lab supply below 10 mA because the bridge's internal compensation network expects a stiff voltage source. Tube fittings must use soft silicone or Tygon tubing that grips the 4.93 mm port - push-on barb compression leaks concentration.

Place the bridge decoupling capacitor (100 nF X7R minimum) directly across the VS and GND pins at the through-hole pads. Route the two bridge output traces as a differential pair with matched length and 0.2 mm spacing, and flood the surrounding area with a single-point-grounded guard ring tied to the INA reference pin. Avoid running digital clock traces parallel to the bridge output pair for more than 5 mm - the millivolt-level signal is easily corrupted by 50 mV of capacitive coupling.

규정 준수 정보

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
무연
Unknown
무할로겐
Unknown
분쟁 광물
Unknown

RoHS and lead-free status not explicitly documented in current NXP product page. MPX12 family pre-dates universal RoHS enforcement; contact NXP for part-specific compliance documentation. AEC-Q100 not applicable - this is a consumer/industrial-grade sensor, not automotive-qualified.

데이터 검증일: 2026-10-15 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

MPX12DP datasheet NXP MPX12DP pressure sensor 10 kPa differential pressure sensor 4-SIP uncompensated silicon pressure sensor MPX12DP vs MPX12GP MPX12DP drop-in replacement buy MPX12DP MPX12DP pinout 4-SIP 5.5 mV/kPa pressure sensor HVAC VAV airflow pressure sensor medical CPAP pressure sensor 10 kPa filter saturation differential pressure obsolete MPX12DP equivalent MPX12DP instrumentation amplifier how to calibrate MPX12DP

관련 부품 & 용어

NXP Semiconductors MPX12DP MPX12D MPX12GP MPX12AP MPX12GP6U MPXV6250GC6U piezoresistive pressure sensor silicon pressure sensor differential pressure sensor uncompensated sensor Wheatstone bridge MEMS pressure sensor 4-SIP package HVAC VAV filter saturation medical ventilator tank level sensing instrumentation amplifier REF5025 INA333 RoHS REACH IEC 60601
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기