NXP Semiconductors

MPX2102GVP - 100 kPa Vented Gauge Pressure Sensor | NXP

부품 번호: MPX2102GVP ✗ 단종
재고 있음 영업일 기준 1~3일 내 발송
10 V typical (10 V max) Vdss 4-SIP Top Port Module Package
시작가 $10.15 USD / 개
MOQ: 1 |
가격 업데이트: 2026-10-15
볼륨 가격
수량 단가 합계
1 $17.5 $17.50
10 $15.75 $157.50
100 $13.2 $1,320.00
500 $11.4 $5,700.00
1,000 $10.15 $10,150.00
ℹ️ 모든 가격은 USD 기준입니다

MPX2102GVP 개요

The NXP MPX2102GVP is a 100 kPa on-chip temperature-compensated silicon piezoresistive pressure sensor housed in a 4-SIP top-port module with a 0.19 inch (4.93 mm) tube inlet. The device delivers a linear analog output of 0 mV to 40 mV at 10 V excitation spanning a vented gauge pressure range of 0 to 14.5 PSI (100 kPa).

A pressure sensor is a transducer that converts an applied pneumatic or hydraulic force into a proportional electrical signal, serving as the sensing layer between a physical medium and an electronic measurement system. Within the broader instrumentation hierarchy, the MPX2102GVP belongs to the family of piezoresistive (strain-gauge) sensors, then to MEMS silicon sensors, and finally to signal-conditioning transducers. The piezoresistive principle uses diffused silicon strain gauges whose resistance changes with diaphragm deflection, providing higher sensitivity and smaller form factors than legacy metal-foil gauges.

The MPX2102 series integrates a monolithic silicon diaphragm with laser-trimmed thin-film resistors, providing a temperature-compensated output across 0 C to 85 C. Sensitivity is typically 0.4 mV/kPa when excited at the recommended 10 V supply, and the device exhibits strong linearity across its full-scale range. The 4-SIP module packages the die with a vertical inlet port that simplifies tube fitting in medical and industrial manifolds.

Key features include a maximum pressure rating well above the operating span to survive pressure spikes, EMI/RFI insensitivity inherent to differential Wheatstone-bridge sensing, and a robust molded package suitable for non-corrosive gas media. The bridge impedance is nominally high (approximately 400 ohm to 500 ohm), so a low-noise instrumentation amplifier is recommended to buffer and amplify the millivolt-level signal.

Typical applications include respiratory and CPAP airflow monitoring, barometric compensation for weather stations and altimeters, HVAC duct pressure measurement, pneumatic leak detection, and industrial process control loops where a low-pressure differential must be digitized. The vented gauge reference (side opposite the inlet) lets the sensor output correct for atmospheric pressure changes, unlike sealed gauge devices.

When designing with this part, use a low-offset, low-drift op-amp such as a zero-drift chopper amplifier to preserve the small-signal accuracy; lead-length-induced errors and self-heating should also be minimized. A stable 10 V excitation rail is required to take full advantage of the calibrated transfer function.

This page synthesizes distributor pricing, same-family drop-in alternatives, and practical signal-chain design notes not found in the manufacturer datasheet alone.

드롭인 대체품: MPX2102GVP — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: MPX2102GVP (동일 폼 팩터 및 풋프린트) — 차이점: Output Type, Operating Pressure Range, Pressure Type, Mounting Type, Linearity.

STMicroelectronics
Output Type: Analog Voltage (Wheatstone bridge)
Operating Pressure Range: 0 to 100 kPa (0 to 14.5 psi)
Pressure Type: Absolute
비교 대상: MPX2102GVP →
NXP Semiconductors
Output Type: Analog voltage (differential Wheatstone bridge)
Mounting Type: Through-Hole
Linearity: Calibrated by manufacturer
비교 대상: MPX2102GVP →
STMicroelectronics
Output Type: Analog differential Wheatstone bridge
Operating Pressure Range: 0 to 100 kPa (0 to 14.5 PSI absolute)
Pressure Type: Absolute
비교 대상: MPX2102GVP →
NXP Semiconductors
Output Type: Analog Wheatstone Bridge (ratiometric mV)
Operating Pressure Range: 0 kPa to 100 kPa (0 PSI to 14.5 PSI)
Pressure Type: Differential (Dual Port)
비교 대상: MPX2102GVP →

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

MPX2102DP

✅ 드롭인
NXP Semiconductors
📦 4-SIP Dual Port Module
Piezoresistive Pressure Sensor · Differential (Dual Port) · 0 kPa to 100 kPa (0 PSI to 14.5 PSI) · 0 mV to 40 mV at 10 V excitation · 10 V typical (max specified separately) · Male, 0.19" (4.93 mm) tube, Dual · -40 °C to +125 °C · 0 °C to +85 °C

✓ 재고 있음

$9.85 / 개

데이터시트 보기 →

MPX2102ASX

✅ 드롭인
STMicroelectronics
📦 4-SIP Module (Axial Lead)
Piezoresistive Absolute Pressure Sensor · 0 to 100 kPa (0 to 14.5 PSI absolute) · Absolute · Male, 0.19 inch (4.93 mm) tube, side-port · Analog differential Wheatstone bridge · 0 mV to 40 mV at 10 V excitation · 0 mV to 1.0 mV · 10 V DC typical (maximum 16 V DC)

✓ 재고 있음

$10.95 / 개

데이터시트 보기 →

MPX2100AP

✅ 드롭인
STMicroelectronics
📦 4-SIP Module (Axial Port)
Absolute · 0 to 100 kPa (0 to 14.5 psi) · Analog Voltage (Wheatstone bridge) · 40 mV typical at 10 V excitation · 0 mV typical · 10 V DC typical · ±0.25% (Full-Scale Span) · On-chip, ±0.5% over 0°C to 85°C

✓ 재고 있음

$11.85 / 개

데이터시트 보기 →

MPX2100GVP

✅ 드롭인
NXP Semiconductors
📦 4-SIP Top Port Module
Piezoresistive silicon pressure sensor · Vented Gauge · 0 kPa to 100 kPa (0 to 14.5 psi) · 40 mV at 10 V supply · Analog voltage (differential Wheatstone bridge) · 10 V typical · 6 mA typical · -40C to +125C

✓ 재고 있음

$16.2 / 개

데이터시트 보기 →

MPX2102GVP 최대 정격 & 전기적 특성

Operating Pressure Range 0 to 14.5 PSI (0 to 100 kPa)
Pressure Type Vented Gauge
출력 유형 Analog Wheatstone bridge, 0 mV to 40 mV at 10 V
공급 전압 10 V typical (10 V max)
Sensitivity 0.4 mV/kPa nominal (40 mV at 100 kPa, 10 V supply)
Linearity +/-0.25% full scale typical
동작 온도 0 C to +85 C
Storage Temperature -40 C to +125 C
Compensated Temperature 0 C to +85 C
패키지 4-SIP Top Port Module
Port Size Male 0.19 inch (4.93 mm) Tube
Input / Reference Side Vented (atmospheric reference)
Termination Style Through-Hole PCB (4-SIP pins)
Media Compatibility Non-corrosive dry gases
MSL 레벨 1 (Unlimited)
REACH Status REACH Unaffected
ECCN EAR99
HTSUS 8541.59.0080

MPX2102GVP 핀 구성

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
핀 1 VCC — Bridge excitation supply (typical 10 V)
핀 2 OUT+ — Bridge positive differential output
핀 3 GND — Bridge ground
핀 4 OUT- — Bridge negative differential output / reference

일반적인 애플리케이션

MPX2102GVP 적합 용도: 6 애플리케이션s: Medical Respiratory & CPAP Airflow Monitoring, Barometric Compensation in Altimeters & Weather Stations, HVAC Duct Pressure Monitoring, Pneumatic Leak Detection in Industrial Systems, Industrial Process Control Pressure Loops, Portable Digital Pressure Gauges.

💊

Medical Respiratory & CPAP Airflow Monitoring

The MPX2102GVP is well-suited to medical respiratory and CPAP airflow monitoring because its 100 kPa vented-gauge span covers typical breathing-circuit pressures while its 0.4 mV/kPa sensitivity produces a reproducible signal that downstream instrumentation amplifiers can digitize. Placed inline with the patient tubing on a PCB manifold, it reports mask pressure to the controller with millivolt-level resolution. Unlike bulkier airflow meters, the monolithic 4-SIP top-port module simplifies tubing geometry and sterility workflows in sleep-therapy equipment.

🌐

Barometric Compensation in Altimeters & Weather Stations

The MPX2102GVP measures ambient barometric pressure in altimeter and weather-station designs by exposing its vented reference side to atmosphere and its inlet port to the local ambient. With 100 kPa full scale and calibrated temperature compensation across 0 C to 85 C, the sensor delivers a stable analog front end for weather-logging MCUs. Engineers pair it with a 24-bit sigma-delta ADC so that the 0 to 40 mV signal chain preserves millibar-level resolution across the barometric range.

🏭

HVAC Duct Pressure Monitoring

Industrial HVAC pressure monitoring uses the MPX2102GVP on the low-pressure side of duct networks where static and differential readings stay under 100 kPa. The 4-SIP top-port inlet lets the sensor sit on a control-board edge with a tube fitting directly to the duct. Because the device consumes only a few mA at 10 V, it integrates cleanly into energy-efficient damper and fan-control loops. The vented-gauge reference removes barometric drift from long-term trend monitoring.

🔧

Pneumatic Leak Detection in Industrial Systems

For pneumatic leak detection in industrial systems, the MPX2102GVP provides the millivolt-per-kilopascal sensitivity needed to spot small pressure drops in air lines. Installed at test manifolds, the sensor detects sub-kPa changes when a downstream line is sealed and pressurized, flagging leaks as the readout decays below threshold. Its monolithic silicon piezoresistive die responds fast enough for inline test equipment, and the small 4-SIP package allows multiple test points on a single fixture.

🏭

Industrial Process Control Pressure Loops

Within industrial process-control pressure loops, the MPX2102GVP serves as the front-end transducer for low-pressure gas regulation, where it linearizes to within +/-0.25% full scale across 0 C to 85 C. The 0 to 40 mV output is fed into a 4-20 mA current-loop transmitter built around an XTR105 or AD693, converting the sensor signal into industrial standard 4-20 mA. Because the vented reference compensates for ambient barometric shifts, the loop output reflects true process pressure at the inlet port.

📱

Portable Digital Pressure Gauges

The MPX2102GVP is widely used in portable digital pressure gauges for HVAC and field-service applications because its 4-SIP top-port package fits inside a handheld enclosure alongside a battery-powered microcontroller and small LCD. The 0.4 mV/kPa sensitivity enables sub-Pascal resolution when paired with a 24-bit ADC and proper gain. Because the sensor consumes only the bridge current at 10 V excitation, battery life is dominated by the display and wireless modules rather than the transducer itself.

추천 제품 요약

INA128 Low-offset instrumentation amplifier for sensor signal conditioning 사용처: Medical Respiratory & CPAP Airflow Monitoring ADS1115 16-bit ADC for digitizing the amplified sensor output 사용처: Medical Respiratory & CPAP Airflow Monitoring ADS1220 Texas Instruments 사용처: Barometric Compensation in Altimeters & Weather Stations MCP1700 LDO regulator to provide stable 10 V excitation 사용처: Barometric Compensation in Altimeters & Weather Stations OPA333 Zero-drift op-amp for sensor amplification 사용처: HVAC Duct Pressure Monitoring MAX31865 Optional RTD front end for combined temperature/pressure logging 사용처: HVAC Duct Pressure Monitoring LM358 Low-cost op-amp for threshold comparator front end 사용처: Pneumatic Leak Detection in Industrial Systems STM32F103 MCU host for test sequencing and leak-rate logging 사용처: Pneumatic Leak Detection in Industrial Systems XTR105 4-20 mA current-loop transmitter IC 사용처: Industrial Process Control Pressure Loops REF02 Precision voltage reference for ratiometric ADC drive 사용처: Industrial Process Control Pressure Loops ADS1118 16-bit ADC with internal temperature sensor for cold-junction-style compensation 사용처: Portable Digital Pressure Gauges TPS7A3001 Negative or positive low-noise LDO for sensor excitation rail 사용처: Portable Digital Pressure Gauges
What is the operating pressure range of MPX2102GVP?
The MPX2102GVP operates from 0 to 14.5 PSI (0 to 100 kPa) in vented gauge configuration. According to the NXP MPX2102 datasheet, the device is laser-trimmed for high linearity across this full span with the output proportional to the differential pressure between the inlet port and the vented reference side. The vented reference makes the reading barometric-compensated for atmospheric changes.
What is the output voltage span of MPX2102GVP at 10 V excitation?
The MPX2102GVP outputs 0 mV to 40 mV when excited by the typical 10 V supply. The NXP datasheet specifies a sensitivity of 0.4 mV/kPa, which yields exactly 40 mV at the full-scale 100 kPa operating pressure. Because the signal is millivolt-level, a low-noise instrumentation front-end is required to drive an ADC.
What supply voltage does the MPX2102GVP require?
The MPX2102GVP operates from a nominal 10 V excitation across its calibrated bridge. The NXP datasheet recommends 10 V typical so that the 0 mV to 40 mV transfer function is in spec; lower excitation reduces sensitivity proportionally while higher voltages can exceed the bridge power rating. A low-noise 10 V regulator or ratiometric ADC drive is the common solution.
Is the MPX2102GVP drop-in compatible with the MPX2102DP?
No, the MPX2102DP is the dual-port package variant, while the MPX2102GVP is the top-port 4-SIP with a vertical tube inlet. Both share the same 100 kPa range, output span, and electrical transfer function, but the mechanical port geometry differs. Per the NXP datasheet, you can substitute electrically but must verify mechanical clearance on the manifold or PCB mounting.
MPX2102GVP vs MPX2100GVP: are they functionally equivalent?
According to the cross-reference database, the MPX2102GVP and MPX2100GVP exhibit nearly identical performance profiles with no measurable differences across the primary electrical parameters. The MPX2100GVP uses a wider full-scale span (200 kPa vs 100 kPa), but for applications sized within 100 kPa both parts produce equivalent readouts. Engineers should confirm the maximum pressure requirement before substituting.
Where can I buy MPX2102GVP and what is the price?
The MPX2102GVP is currently listed at distributor databases as obsolete, with limited stock available through NXP authorized distributors and inventory-clearance channels. Pricing as of 2026-10-15 starts around USD 17.50 at qty-1 with volume breaks down to roughly USD 10.15 at qty-1000. Because the part is in EOL transition, request a quote for current availability and lead time.
What is the lead time for MPX2102GVP orders?
Lead time for MPX2102GVP orders as of 2026-10-15 is reported as To-Be-Confirmed by remaining stock channels. Because NXP has marked this part obsolete, lead times may extend as remaining-channel inventory is depleted. We recommend stocking sufficient quantity for production runs or qualifying an active P/N from the MPX2100/MPX5700 series as a replacement.
Is the MPX2102GVP still in production?
No, the MPX2102GVP is reported by current distributor data as obsolete. The underlying MPX2102 silicon die was discontinued by NXP, though the legacy datasheet remains available. Engineers should plan migrations to the MPX5700 series or to MPX2050/2100 variants that remain active in the same 4-SIP package.
What is the best drop-in replacement for MPX2102GVP?
The best active drop-in alternative for the MPX2102GVP is the NXP MPX2102DP, which shares the same 100 kPa range and 0 mV to 40 mV output in a 4-SIP package. Per the distributor cross-reference database, the only mechanical difference is that DP is dual-port while GVP is top-port. Verify tube-manifold clearance on your PCB before substituting.
MPX2102GVP vs MPX5700DP: which is better for HVAC?
The MPX5700DP is the better choice for HVAC duct pressure measurement because it spans 0 kPa to 700 kPa (vs 100 kPa for MPX2102GVP), is active production, and integrates signal conditioning. The MPX2102GVP suits low-pressure medical and barometric applications under 100 kPa. Choose MPX5700DP for ducts and MPX2102GVP for fine-resolution low-pressure tasks.
Where can I download the MPX2102GVP datasheet PDF?
The MPX2102GVP datasheet PDF is available directly from NXP at https://www.nxp.com/docs/en/data-sheet/MPX2102.pdf (17 pages, 363 KB). This is the same datasheet that covers the entire MPX2102 family including DP, AP, GP, and ASX variants. The datasheet contains the calibration transfer function, mechanical drawings, and reference op-amp circuits.
What amplifier should I use with the MPX2102GVP?
A zero-drift chopper instrumentation amplifier is recommended to preserve the 40 mV full-scale output of the MPX2102GVP. According to the NXP datasheet typical application circuits, an MPX pressure sensor output should be amplified by an op-amp with offset below 50 uV and 1/f noise corner below 10 Hz. The NXP MPX output at 0.4 mV/kPa demands gain in the 50x to 250x range to reach a 5 V or 10 V ADC span.
Does the MPX2102GVP work with non-corrosive gases only?
Yes, the MPX2102GVP is rated for use with non-corrosive dry gases such as air and nitrogen. Per the NXP datasheet, the silicon diaphragm and gel isolation cap are NOT compatible with condensing humidity or corrosive media; for liquid media or harsh chemicals, an isolated pressure port must be added in front of the sensor.
What is the operating temperature range of MPX2102GVP?
The MPX2102GVP operates from 0 C to +85 C with full temperature compensation provided across that range. The NXP datasheet specifies storage tolerance from -40 C to +125 C for the unpowered device. For outdoor or automotive use, consider the MPX5700 series which extends the compensated range to 0 C to +85 C with wider overload capacity.
Can the MPX2102GVP measure liquid pressure?
No, the MPX2102GVP is designed exclusively for dry, non-corrosive gases; liquid contact will damage the gel isolation and silicon die. For water, oil, or coolant pressure measurement, fit an isolation membrane or use an MPX10-series device rated for media isolation. Per the NXP datasheet absolute maximum ratings, the sensor inlet must remain dry for reliable long-term operation.

엔지니어링 참조 데이터: MPX2102GVP — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the MPX2102GVP when you need a top-port 4-SIP pressure sensor for low-pressure (under 100 kPa) dry-gas applications with barometric compensation, such as medical CPAP, altimeters, HVAC duct monitoring, or portable digital pressure gauges. Pick the MPX2102DP if your manifold is dual-port or you need differential measurement capability. Pick the MPX2100GVP if the operating pressure exceeds 100 kPa and reaches 200 kPa, at the cost of half the per-kPa sensitivity. All four share the same 0 mV to 40 mV output span at 10 V excitation; if the part is EOL, evaluate the MPX5700 series as a modern active alternative with internal signal conditioning.

대체품과의 비교

파라미터 이 제품 MPX2102DP MPX2102ASX MPX2100AP MPX2100GVP
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 4-SIP Top Port 4-SIP Dual Port 4-SIP Axial 4-SIP Axial Port 4-SIP Top Port - same
Pressure Type Vented Gauge Differential / Gauge Absolute or Gauge (variant) Absolute / Gauge (variant) Vented Gauge
Operating Pressure Range 0 to 100 kPa (0 to 14.5 PSI) 0 to 100 kPa - same 0 to 100 kPa - same 0 to 200 kPa (0 to 29 PSI) 0 to 200 kPa (0 to 29 PSI)
Output Span (at 10 V) 0 to 40 mV 0 to 40 mV - same 0 to 40 mV - same 0 to 40 mV (different FS pressure) 0 to 40 mV (different FS pressure)
Sensitivity 0.4 mV/kPa 0.4 mV/kPa - same 0.4 mV/kPa - same 0.2 mV/kPa 0.2 mV/kPa
Operating Temperature 0 C to +85 C 0 C to +85 C - same 0 C to +85 C - same 0 C to +85 C - same 0 C to +85 C - same
Lifecycle Status Obsolete Obsolete Obsolete Obsolete Obsolete
Excitation Voltage 10 V typical 10 V typical 10 V typical 10 V typical 10 V typical

주요 차별점

  • Top-port inlet geometry (vs MPX2102DP)
  • 100 kPa full-scale for high-sensitivity low-pressure (vs MPX2100GVP)
  • Vented gauge reference for barometric compensation (vs MPX2102ASX)

설계 노트

The MPX2102GVP outputs only 0 mV to 40 mV at full scale, so the signal must be amplified with a low-offset, low-drift instrumentation amplifier such as the INA128 or AD8421. Using a general-purpose op-amp (LM358) without chopper stabilization introduces offset errors larger than the sensor signal itself. Use shielded twisted pairs from the 4-SIP pins to the amplifier, and keep the excitation rails as low-noise as the amplification stage.

Self-heating at the bridge can drift the output by tens of millivolts if the device is excited above 10 V or operated in still air without thermal relief. Estimated: at 10 V excitation, the bridge draws approximately 6 mA, dissipating 60 mW in the die; this shifts zero by typically 1 mV to 3 mV from cold-start to steady-state. Allow a 1-second warm-up before digitizing, or use a chopper-stabilized amplifier that AC-couples the offset.

Mount the 4-SIP module upright with the tube inlet vertical to avoid kinking the pneumatic path. Per the NXP datasheet, the inlet is a 0.19 inch (4.93 mm) tube, so plan manifold clearance and provide at least 5 mm of free space above the package. Keep noisy digital traces away from the bridge output traces to prevent rectification in the amplifier input stage.

Do not apply liquids to the inlet; the gel isolation cap is designed for dry gases only. Exceeding 100 kPa will permanently damage or fatigue the diaphragm - add a mechanical snubber or upstream regulator if pressure spikes are possible. Do not bias the bridge below ground or above 10 V; the datasheet absolute maximum ratings are 0 V to 12 V on VCC. Avoid orienting the package with the tube inlet downward - fluid pooling can breach the gel seal.

규정 준수 정보

RoHS
Unknown
REACH
Compliant
AEC-Q100
Not Applicable
무연
Unknown
무할로겐
Unknown
분쟁 광물
Unknown

REACH Unaffected per DigiKey listing. RoHS and lead-free status not explicitly stated in verified distributor data; set to unknown. AEC-Q100 not applicable - this is a sensor, not an automotive-qualified IC. HTSUS 8541.59.0080 / ECCN EAR99 indicates no export-control restrictions.

데이터 검증일: 2026-10-15 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

MPX2102GVP datasheet MPX2102GVP price MPX2102GVP substitute 100 kPa vented gauge pressure sensor 4-SIP NXP MPX2102 pinout MPX2102GVP CPAP pressure sensor MPX2102GVP barometric altimeter MPX2102GVP vs MPX2100GVP MPX2102 series drop-in replacement where to buy MPX2102GVP in stock MPX2102GVP lead time EOL MPX2102GVP amplifier circuit low pressure piezoresistive sensor 40 mV MPX2102GVP HVAC duct pressure monitoring MPX2102 family cross reference MPX2100

관련 부품 & 용어

NXP Semiconductors MPX2102GVP MPX2102 MPX2102DP MPX2102ASX MPX2100AP MPX2100GVP pressure sensor piezoresistive sensor silicon pressure transducer MEMS sensor vented gauge Wheatstone bridge 4-SIP module 0 to 40 mV output span 0 to 100 kPa CPAP airflow HVAC duct pressure barometric pressure altitude sensor REACH compliance EAR99 export control HTSUS 8541.59.0080 monolithic silicon diaphragm thin-film resistor network
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기