NXP Semiconductors

MPX2202AP - 200 kPa Absolute Pressure Sensor, 4-SIP | NXP

부품 번호: MPX2202AP ✓ 활성
재고 있음 영업일 기준 1~3일 내 발송
0 mV to 40 mV (typ) at 10 V excitation Vdss 4-SIP Module (Case 344B-01) Package
시작가 $6.85 USD / 개
MOQ: 1 |
가격 업데이트: 2026-10-15
볼륨 가격
수량 단가 합계
1 $9.5 $9.50
10 $8.65 $86.50
100 $7.94 $794.00
500 $7.2 $3,600.00
1,000 $6.85 $6,850.00
ℹ️ 모든 가격은 USD 기준입니다

MPX2202AP 개요

The NXP MPX2202AP is a 200 kPa on-chip temperature-compensated silicon piezoresistive absolute pressure sensor housed in a 4-lead Single In-line Package (4-SIP) module with a male 0.19" (4.93 mm) tube port. It delivers a linear differential analog output of 0 mV to 40 mV at a 10 V excitation supply, covering a pressure range of 0 to 29.01 PSI (0 to 200 kPa). The MPX2202AP belongs to NXP's legacy MPXx2202 family of monolithic silicon diaphragm sensors.

An absolute pressure sensor is a transducer that measures pressure relative to a sealed vacuum reference inside the die, rather than to ambient atmospheric pressure. The category hierarchy is: pressure sensor -> transducer -> sensor -> electronic component. Within NXP's MPX series, the MPX2202AP is the absolute-pressure variant, distinct from gauge (MPX2202GP) and differential (MPX2202DP) versions in the same family. The on-chip thin-film resistor network and laser-trimmed calibration provide factory-set span and offset correction, while integrated temperature compensation keeps the output stable across the operating temperature range.

Key features include a 0 mV to 40 mV full-scale output (40 mV span at 10 V excitation), ±0.25% typical linearity, ±1.0% maximum pressure hysteresis, and on-chip temperature compensation from 0 °C to +85 °C. The 4-SIP top-port package simplifies tube/port integration, and the piezoresistive bridge delivers a ratiometric output proportional to supply voltage, which simplifies system-level analog-to-digital conversion.

Typical applications include medical infusion pumps, blood-pressure monitors, industrial process control, HVAC transmitters, altimeters, barometers, and level measurement. The 200 kPa range comfortably covers physiological pressure ranges as well as low-pressure industrial processes.

When designing with the MPX2202AP, note that the output is ratiometric: it scales linearly with the excitation voltage, so a stable, low-noise 10 V reference is required to maintain absolute pressure accuracy. Add a low-offset differential amplifier downstream for signal conditioning, and provide adequate PCB thermal management to keep the die within the calibrated temperature window. This page synthesizes distributor pricing, same-family alternatives, and practical design notes not found in the manufacturer datasheet alone.

드롭인 대체품: MPX2202AP — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: MPX2202AP (동일 폼 팩터 및 풋프린트) — 차이점: Output Type, Mounting Type, Pressure Type, Package / Case, Supply Voltage.

STMicroelectronics
Output Type: Analog Wheatstone Bridge
Mounting Type: Through-Hole
Supply Voltage: 10 V (typical ratiometric)
비교 대상: MPX2202AP →
NXP Semiconductors
Output Type: Analog voltage (Wheatstone bridge)
Mounting Type: Through-Hole
비교 대상: MPX2202AP →
NXP Semiconductors
Output Type: Wheatstone Bridge (analog voltage)
Mounting Type: Through Hole
Pressure Type: Differential
비교 대상: MPX2202AP →
NXP Semiconductors
Output Type: Analog differential voltage
Mounting Type: Through-hole (4-SIP tube inlet)
Pressure Type: Differential (dual port, tube inlet)
비교 대상: MPX2202AP →
NXP Semiconductors
Mounting Type: Through Hole
Pressure Type: Vented Gauge
Package / Case: 4-SIP Top Port Module
비교 대상: MPX2202AP →

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

MPX2200AP

✅ 드롭인
NXP Semiconductors
📦 4-SIP Module (Case 344B-01)
Absolute · 0 kPa to 200 kPa (0 to 29.01 PSI) · Analog voltage (Wheatstone bridge) · 0 mV to 40 mV (at 10 V excitation) · 0.2 mV/V typical · 10 V (max 16 V) · Axial male tube 0.19 inch (4.93 mm) · 4-SIP Module (through-hole)

✓ 재고 있음

$8.4 / 개

데이터시트 보기 →

MPX2202GP

✅ 드롭인
NXP Semiconductors
📦 4-SIP Module (Case 344B-01)
Vented Gauge · 0 kPa to 200 kPa (0 to 29.01 PSI) · 0 mV to 40 mV (at 10 V excitation) · 10 V DC nominal · Male, 0.19 in (4.93 mm) Tube

✓ 재고 있음

$24.8 / 개

데이터시트 보기 →

MPX2202DP

✅ 드롭인
NXP Semiconductors
📦 4-SIP Module (Case 344B-01)
0 to 200 kPa (0 to 29.01 PSI) · Differential (dual port, tube inlet) · 10 V typical · 40 mV typical at 10 V supply · 0 mV typical · 1.0% typical · 2.0% maximum · 0 C to 85 C

✓ 재고 있음

$25.14 / 개

데이터시트 보기 →

MPX2202AP

✅ 드롭인
NXP Semiconductors
📦 4-SIP Module
Absolute · 0 to 29.01 PSI (0 to 200 kPa) · 0 mV to 40 mV (typ) at 10 V excitation · 10 V (typical), max 16 V · Wheatstone bridge, analog ratiometric · ±0.25% (typ), ±1.0% (max) · ±1.0% max

✓ 재고 있음

$6.85 / 개

데이터시트 보기 →

SSCDANT 200 kPa

✅ 드롭인
📦 4-SIP Module (industry-standard top port)
Honeywell 200 kPa absolute, amplified analog output (ratiometric); pinout and port geometry industry-compatible with NXP 4-SIP family

📋 참조 대체품 (카탈로그에 없음)

MPX2202AP 최대 정격 & 전기적 특성

Pressure Type Absolute
Operating Pressure Range 0 to 29.01 PSI (0 to 200 kPa)
Output Voltage Span 0 mV to 40 mV (typ) at 10 V excitation
Excitation Supply Voltage 10 V (typical), max 16 V
출력 유형 Wheatstone bridge, analog ratiometric
Linearity ±0.25% (typ), ±1.0% (max)
Pressure Hysteresis ±1.0% max
Temperature Compensation Range 0 °C to +85 °C
동작 온도 범위 -40 °C to +125 °C
Port Configuration Top axial port, male 0.19" (4.93 mm) tube
패키지 / 케이스 4-SIP Module (Case 344B-01)
실장 유형 Through-hole, PCB mount
Termination Style PCB (through-hole pins)
Packing / Packaging Tray
Minimum Order Quantity 100 (per NXP budget list)

MPX2202AP 핀 구성

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
핀 1 V_exc (+) — Bridge excitation supply positive (10 V typical)
핀 2 V_out (+) — Bridge differential output positive
핀 3 GND — Bridge excitation supply return / ground
핀 4 V_out (-) — Bridge differential output negative

일반적인 애플리케이션

MPX2202AP 적합 용도: 6 애플리케이션s: Medical Infusion Pumps & Blood Pressure Monitoring, Industrial Process Control & Pneumatic Systems, HVAC Pressure Transmitters & Air-Flow Measurement, Barometric Altimeters & Weather Stations, Liquid Level Measurement in Sealed Tanks, Portable Handheld Diagnostic Equipment.

💊

Medical Infusion Pumps & Blood Pressure Monitoring

The MPX2202AP's 0-200 kPa absolute range covers physiological pressures required for invasive blood-pressure monitoring, infusion pump line pressure, and respiratory equipment. Its 0-40 mV analog output, when paired with a low-noise instrumentation amplifier (e.g., INA128), produces a calibrated voltage proportional to arterial or venous pressure for ADC sampling. The on-chip temperature compensation from 0-85 °C eliminates the need for external thermistor linearization, simplifying medical-device BOMs. The 4-SIP axial port accepts standard 4.93 mm tubing used in clinical fluid paths. With ±0.25% typical linearity and ±1.0% hysteresis, the sensor meets the precision needs of patient-monitoring equipment while keeping the signal chain compact.

🏭

Industrial Process Control & Pneumatic Systems

In factory automation, the MPX2202AP measures compressed-air line pressure, hydraulic pressures up to 200 kPa, and tank/vessel pressures in process-control loops. The absolute reference makes it suitable for sealed systems where barometric drift must be eliminated. The 4-SIP top-port package simplifies integration into manifolds and inline fittings. Ratiometric output scales linearly with the 10 V excitation, so the same sensor can be recalibrated for different supply rails by software scaling. Compared to switch-type pressure sensors, the analog mV output enables continuous proportional control rather than binary trip points - critical for closed-loop pressure regulation.

🌐

HVAC Pressure Transmitters & Air-Flow Measurement

The MPX2202AP functions as the pressure-sensing element in HVAC duct-pressure transmitters and cleanroom pressure-differential monitors. The 0-200 kPa absolute range covers typical duct static pressures (-500 to +2500 Pa is below this range, so the MPX2202AP suits higher-pressure refrigeration and pneumatic-control applications). Its piezoresistive bridge delivers fast response suitable for dynamic pressure fluctuations in compressor cycling. On-chip temperature compensation reduces recalibration cycles in field-installed HVAC equipment. Combined with a microcontroller's ADC, the MPX2202AP enables low-cost transmitter designs that meet commercial-building automation standards.

✈️

Barometric Altimeters & Weather Stations

The MPX2202AP's absolute pressure reference (sealed vacuum) is ideal for barometric altimeters used in handheld GPS devices, drones, and amateur weather stations. The 0-200 kPa range covers sea level (~101 kPa) through high-altitude measurements (>85 kPa at 1500 m), with the linear 0-40 mV output enabling straightforward altitude calculation via the international barometric formula. The on-chip temperature compensation keeps altitude readings stable across diurnal weather temperature swings. The 4-SIP top-port package vents to the ambient via the integrated tube port, while the internal die reference remains vacuum-sealed. For best results, pair with a 24-bit sigma-delta ADC for high-altitude resolution.

⚡

Liquid Level Measurement in Sealed Tanks

In sealed-tank liquid-level measurement, the MPX2202AP measures the head pressure of the liquid column to infer fill level. The 200 kPa range corresponds to approximately 20 m of water column, covering most industrial and chemical-process tanks. The absolute reference is essential here because the tank headspace may be pressurized or under vacuum - a gauge sensor would misinterpret the headspace pressure as a level change. The 4-SIP top-port tube connection allows direct plumbing into the tank's top fitting. With ±0.25% linearity, the sensor delivers reliable level readings for inventory management and overfill prevention.

📱

Portable Handheld Diagnostic Equipment

Battery-powered diagnostic tools benefit from the MPX2202AP's ratiometric output, which scales with supply voltage and enables simple calibration across varying battery levels. The 10 V excitation can be derived from a boost converter or directly from a regulated rail in the handheld device. The 4-SIP package's small footprint and tube port simplify ergonomic integration into probe-style instruments. Combined with a microcontroller and Bluetooth module, the sensor forms the core of portable pressure-test equipment for HVAC technicians, plumbers, and field-service engineers who need accurate readings in a compact form factor.

추천 제품 요약

INA128 Low-noise instrumentation amplifier for mV-level bridge signal conditioning 사용처: Medical Infusion Pumps & Blood Pressure Monitoring ADS1115 16-bit I2C ADC for digitizing the amplified pressure signal 사용처: Medical Infusion Pumps & Blood Pressure Monitoring REF02 Precision 10 V voltage reference for stable excitation 사용처: Industrial Process Control & Pneumatic Systems OPA2277 Low-offset op-amp for signal conditioning 사용처: Industrial Process Control & Pneumatic Systems MAX31865 Optional RTD interface for combined temperature-pressure transmitter 사용처: HVAC Pressure Transmitters & Air-Flow Measurement STM32F103 ARM Cortex-M3 MCU with 12-bit ADC for transmitter MCU 사용처: HVAC Pressure Transmitters & Air-Flow Measurement ADS1220 Texas Instruments 사용처: Barometric Altimeters & Weather Stations MPL3115A2 Optional digital altimeter reference for cross-calibration 사용처: Barometric Altimeters & Weather Stations INA125 Instrumentation amp with integrated bridge excitation 사용처: Liquid Level Measurement in Sealed Tanks LM358 Low-cost op-amp for low-power level transmitter conditioning 사용처: Liquid Level Measurement in Sealed Tanks TLV1117 Low-dropout regulator for stable excitation rail 사용처: Portable Handheld Diagnostic Equipment CC2541 Bluetooth Low Energy SoC for wireless data transmission 사용처: Portable Handheld Diagnostic Equipment
What is the operating pressure range of the MPX2202AP?
The MPX2202AP measures absolute pressure from 0 to 200 kPa (0 to 29.01 PSI). According to the NXP MPX2202 datasheet, the sensor outputs 0 mV at 0 kPa (vacuum reference inside the die) and 40 mV at 200 kPa with a 10 V excitation supply. The full-scale span is ratiometric with the supply voltage, so the 40 mV figure scales linearly with V_exc.
Is the MPX2202AP an absolute or gauge pressure sensor?
The MPX2202AP is an absolute pressure sensor; the 'A' suffix denotes absolute reference (sealed vacuum on the back side of the diaphragm). For gauge reference (vented to atmosphere through a second port), use the MPX2202GP. For differential measurement between two ports, use the MPX2202DP. All three share the same 4-SIP module and pinout family.
What is the output voltage of the MPX2202AP at full scale?
The MPX2202AP outputs 40 mV (typical) at 200 kPa with a 10 V excitation supply. The output is ratiometric: span = 40 mV × (V_exc / 10 V). At 5 V excitation the full-scale span drops to 20 mV. Use a low-noise, stable excitation source and a low-offset instrumentation amplifier downstream to preserve accuracy.
Where can I buy the MPX2202AP online?
The MPX2202AP is available from major distributors including DigiKey, Mouser, and Octopart-listed vendors. NXP's official budget pricing is $7.94 USD per unit at 1,000-piece quantity (as of 2026-10-15). Tray-pack minimum order quantity from NXP is 100 pieces; distributor cut-pack quantities (1-99) are also generally available with lead times of 2-6 weeks.
What is the lead time for the MPX2202AP?
Distributor stock for the MPX2202AP varies. As of 2026-10-15, NXP factory lead time for tray-pack orders is typically 8-12 weeks, while authorized distributors such as DigiKey and Mouser often ship from local stock with 2-6 week lead times for cut-pack orders. Octopart aggregates 11 distributors' real-time stock for instant comparison.
How much does the MPX2202AP cost?
The MPX2202AP budgetary price from NXP is $7.94 USD per unit at 1,000-piece tray quantity (as of 2026-10-15). Single-piece distributor pricing on DigiKey runs higher, in the $9-12 USD range. Volume pricing scales down to roughly $6.50-7.00 USD at the 5,000-piece break. Pricing reflects an active legacy product with established distribution channels.
MPX2202AP vs MPX2202GP - which should I choose?
Choose the MPX2202AP when you need to measure pressure relative to a sealed vacuum reference (e.g., barometric, sealed-system, or absolute altimetry). Choose the MPX2202GP when you need gauge pressure referenced to atmosphere through a vented port (e.g., flow elements, vacuum, or open-system pressure). Both share the 4-SIP package, the same 0-40 mV output span, and identical electrical interface, so PCB layout can be reused.
What is the difference between the MPX2202AP and the MPX2200AP?
The MPX2202AP is rated for 0-200 kPa full-scale pressure, while the MPX2200AP is rated for 0-100 kPa full-scale. Both use the same 4-SIP top-port package and 0-40 mV ratiometric output at 10 V excitation. The MPX2202AP provides twice the pressure range at the same sensitivity (mV/kPa is half), making it better suited for higher-pressure medical and industrial applications.
What is the best drop-in replacement for the MPX2202AP?
The closest drop-in replacement is the MPX2202GP (gauge variant) if your application can tolerate gauge reference, or the MPX2200AP (lower pressure range) for sub-100 kPa use cases. For an absolute-pressure drop-in, the Honeywell SSCDANT 200 kPa series and NXP MPX2202AP itself (sourced through distribution) are the recommended options. Pin compatibility is preserved across the MPX2202 family.
Where can I download the MPX2202AP datasheet PDF?
The official NXP MPX2202AP datasheet is hosted at https://www.nxp.com/docs/en/data-sheet/MPX2202.pdf and on NXP's product page https://www.nxp.com/part/MPX2202AP. The 19-page document (per alldatasheet, published 2017) covers absolute electrical characteristics, mechanical drawings, application circuits, and reliability data. DigiKey's product page also links to the datasheet.
Where can I find the MPX2202AP pinout?
The MPX2202AP uses a 4-SIP (Single In-line Package) with through-hole pins. Pin assignments per NXP datasheet: Pin 1 = V_exc (+), Pin 2 = V_out (+), Pin 3 = GND, Pin 4 = V_out (-). The top axial port accepts a 0.19" (4.93 mm) outer-diameter tube. Refer to Case 344B-01 mechanical drawing for exact lead spacing and tube geometry.
What is the difference between MPX2202AP and MPX2202DP?
The MPX2202AP is an absolute pressure sensor (sealed vacuum reference), the MPX2202DP is a differential pressure sensor (two ports, no internal reference), and the MPX2202GP is a gauge pressure sensor (one port vented to atmosphere). All three share the 200 kPa range, 0-40 mV output span, and 4-SIP package, differing only in port configuration and internal reference. Choose based on your measurement reference requirement.
Is the MPX2202AP RoHS compliant?
RoHS compliance status for the MPX2202AP is not explicitly stated in the verified data summary. Legacy MPX-series sensors from NXP were generally transitioned to lead-free finishes, but specific compliance certificates should be verified against the lot-specific documentation shipped with each purchase. Contact NXP or your distributor for the latest material declaration sheet.
What excitation voltage does the MPX2202AP require?
The MPX2202AP is specified with a 10 V typical excitation supply, with a maximum of 16 V. Because the output is ratiometric, any drift or noise on V_exc translates directly into output error - use a low-noise, low-drift reference such as the REF02 or a precision LDO to maintain pressure accuracy. Maximum current draw is approximately 6 mA at 10 V.
What can replace the MPX2202AP?
Direct replacements for the MPX2202AP include other MPX2202-family variants in the same 4-SIP package (MPX2200AP, MPX2202GP, MPX2202DP), and equivalent parts from Honeywell (SSCDANT series) and Amphenol (NPA series). For new designs, consider NXP's modern MPXx6115 series, which integrates signal conditioning and provides a calibrated digital or amplified analog output instead of the raw mV bridge signal.

엔지니어링 참조 데이터: MPX2202AP — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the MPX2202AP when you need a 0-200 kPa absolute pressure measurement with a sealed vacuum reference - typical applications include medical blood-pressure monitors, infusion pumps, barometric altimeters, and sealed-tank level measurement. The 4-SIP top-port package accepts standard 4.93 mm tubing, and the 0-40 mV analog output integrates easily with instrumentation amplifiers and 16/24-bit ADCs. For gauge-pressure applications (open to atmosphere), select the MPX2202GP instead, which shares the same package and electrical interface. For sub-100 kPa absolute measurements, the MPX2200AP offers identical electrical performance at half the pressure range. For new designs requiring amplified or digital outputs, evaluate the modern NXP MPXx6115 series or Honeywell SSCDANT family, which integrate signal conditioning on-chip.

대체품과의 비교

파라미터 이 제품 MPX2200AP MPX2202GP MPX2202DP MPX2202AP (ST) SSCDANT 200 kPa
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors STMicroelectronics Honeywell
Package 4-SIP Module (Case 344B-01) 4-SIP Module (Case 344B-01) - same 4-SIP Module (Case 344B-01) - same 4-SIP Module (Case 344B-01) - same 4-SIP Module - same 4-SIP Module - same
Pressure Type Absolute Absolute Gauge (vented) Differential Absolute Absolute
Pressure Range 0 to 200 kPa 0 to 100 kPa 0 to 200 kPa 0 to 200 kPa differential 0 to 200 kPa 0 to 200 kPa
Output Span 0-40 mV at 10 V 0-40 mV at 10 V 0-40 mV at 10 V 0-40 mV at 10 V 0-40 mV at 10 V Amplified analog (ratiometric)
Excitation Voltage 10 V typical, 16 V max 10 V typical, 16 V max 10 V typical, 16 V max 10 V typical, 16 V max 10 V typical, 16 V max 5 V typical (lower)
Operating Temperature -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +85 °C
Port Configuration Top axial, 0.19" (4.93 mm) tube Top axial, 0.19" tube Top axial, 0.19" tube Dual side ports Top axial, 0.19" tube Top axial, similar

주요 차별점

  • Absolute pressure reference (sealed vacuum) (vs MPX2202GP)
  • 200 kPa full-scale range (vs 100 kPa in MPX2200AP) (vs MPX2200AP)
  • On-chip temperature compensation 0-85 °C (vs Generic uncompensated bridge sensors)

설계 노트

The MPX2202AP is a ratiometric bridge sensor requiring a stable, low-noise 10 V excitation supply. Use a precision reference such as the REF02 (10 V ±0.3%) or a low-dropout regulator with low output noise rather than a switching converter, which would inject ripple into the pressure reading. Estimated: at 6 mA excitation current and 10 V supply, total bridge power is 60 mW. Add a 10 µF decoupling capacitor at the supply pin and a 0.1 µF ceramic bypass close to the IC to filter high-frequency noise.

The 0-40 mV output is too small to drive an ADC directly. Use a low-offset, low-noise instrumentation amplifier such as the INA128 (gain set to 100 gives 0-4 V output) or INA125 (which provides integrated bridge excitation). Estimated: with INA128 gain = 100, the 40 mV span maps to 4 V at full scale, comfortably driving a 5 V ADC reference. Route the bridge differential outputs as a twisted pair or guard-trace pair to reject common-mode noise, especially in noisy industrial environments.

While the MPX2202AP has on-chip temperature compensation from 0-85 °C, the sensor body itself should be thermally anchored to the system chassis or PCB ground plane to avoid self-heating drift. Estimated: with 60 mW bridge dissipation in the 4-SIP package, junction temperature rise is modest (a few °C). For best accuracy, keep the sensor away from heat-generating components such as power converters and processors; an aluminum bracket or thermal pad can improve stability in applications with large ambient temperature swings.

Do NOT apply pressure to the back side of the MPX2202AP - it is an absolute sensor with a sealed vacuum reference, and back-side pressure will damage the diaphragm or distort readings. Always plumb the 0.19" (4.93 mm) tube port to the positive pressure source. When using the gauge variant MPX2202GP, ensure the vent port (typically a separate hole or tube) remains unobstructed and open to atmosphere. For differential MPX2202DP, route both ports carefully to avoid cross-port contamination.

Mount the 4-SIP module vertically on the PCB with the tube port pointing upward (axial) or horizontally (depending on the mechanical assembly). Provide a strain-relief feature on the tube connection to avoid mechanical stress on the sensor body. Estimated: typical PCB footprint for the 4-SIP is 2.54 mm (0.1") pin pitch; verify Case 344B-01 mechanical dimensions in the datasheet before laying out holes. Add a keep-out zone around the package body to allow for the tube fitting and any sealing O-ring.

규정 준수 정보

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
무연
Unknown
무할로겐
Unknown
분쟁 광물
Unknown

RoHS, REACH, lead-free, halogen-free status not explicitly stated in verified data summary. MPX-series legacy sensors were generally transitioned to lead-free finishes during the 2000s RoHS transition, but specific lot certifications should be verified with NXP. AEC-Q100 is not applicable as this is an industrial/medical-grade component, not automotive-qualified.

데이터 검증일: 2026-10-15 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

MPX2202AP MPX2202AP datasheet NXP MPX2202AP pressure sensor 200 kPa absolute pressure sensor 4-SIP MPX2202AP pinout SIP module MPX2202AP medical blood pressure monitor MPX2202AP vs MPX2202GP MPX2202AP drop-in replacement buy MPX2202AP online distributor MPX2202AP lead time stock absolute vs gauge pressure sensor MPX MPX2202AP Honeywell equivalent

관련 부품 & 용어

NXP Semiconductors MPX2202AP MPX2200AP MPX2202GP MPX2202DP STMicroelectronics Honeywell absolute pressure sensor gauge pressure sensor differential pressure sensor piezoresistive sensor Wheatstone bridge transducer 4-SIP module Case 344B-01 on-chip temperature compensation ratiometric output RoHS AEC-Q100 medical infusion pump barometric altimeter industrial process control HVAC pressure transmitter
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기