NXP Semiconductors

MPX5100D - 100 kPa Differential Pressure Sensor | NXP Semiconductors

부품 번호: MPX5100D ✓ 활성
재고 있음 영업일 기준 1~3일 내 발송
4.75 V to 5.25 V Vdss 6-SIP Module (Case 867) Package
시작가 $10.75 USD / 개
MOQ: 1 |
가격 업데이트: 2026-10-15
볼륨 가격
수량 단가 합계
1 $18.5 $18.50
10 $16.2 $162.00
100 $13.85 $1,385.00
500 $12.1 $6,050.00
1,000 $10.75 $10,750.00
ℹ️ 모든 가격은 USD 기준입니다

MPX5100D 개요

The NXP Semiconductors MPX5100D is an integrated, on-chip signal-conditioned, temperature-compensated and calibrated piezoresistive silicon pressure sensor with a 0 to 100 kPa (0 to 14.5 PSI) differential pressure range and a 0.2 V to 4.7 V analog ratiometric output, packaged in a 6-lead through-hole SIP module.

A piezoresistive pressure sensor is a transducer that converts an applied pressure into a measurable electrical signal by exploiting the piezoresistive effect in silicon; the on-chip signal conditioning, temperature compensation, and factory calibration eliminate the need for external amplification or trimming in most applications. Piezoresistive sensors occupy the middle of the transducer hierarchy, between raw resistive strain gauges and fully integrated MEMS pressure modules that include digital I²C/SPI outputs. The MPX5100 series is widely adopted in cost-sensitive embedded designs that need an analog, microcontroller-friendly signal.

Key features include a differential pressure range of 0 to 100 kPa (0 to 14.5 PSI), supply voltage of 4.75 V to 5.25 V, typical full-scale span of 45 mV/kPa, accuracy of ±1.8 %VFSS (maximum), and an operating temperature range of -40 °C to +125 °C. The ratiometric analog output spans 0.2 V at zero pressure to 4.7 V at full-scale pressure, mapping directly into a 0–5 V microcontroller ADC without external op-amps. The monolithic single-element die combines micromachined sensing, thin-film metallization and bipolar processing for long-term stability.

Architecturally, the device is a monolithic silicon die in which a micromachined diaphragm and four piezoresistors form a Wheatstone bridge; the bridge is excited by the supply voltage so the output is ratiometric, and on-chip ASIC circuitry offsets, spans, and temperature-compensates the raw signal. The calibrated output swing of 4.5 V across 100 kPa gives a usable sensitivity of 45 mV/kPa and supports direct connection to a 10-bit ADC. The through-hole SIP module includes a dual axial pressure port geometry (P1 = high-pressure side, P2 = low-pressure or vacuum reference) for differential measurement on tube-fed systems.

Typical applications include automotive engine manifold absolute pressure (MAP) sensing, barometric air-pressure monitoring, HVAC duct pressure measurement, medical respiratory equipment, and industrial process-control loops. The wide temperature range and ratiometric output make it a drop-in choice for ECU analog-input front-ends.

When designing in the MPX5100D, place 100 nF and 470 pF decoupling capacitors close to the supply pin to suppress switching noise from digital logic sharing the same 5 V rail. Tubes on the P1/P2 ports should be kept as short as possible and oriented vertically downward to avoid condensate pooling on the die. Designers targeting board-mounted applications should evaluate the surface-mount 8-pin SOIC option MPXV5100GC6U if a vertical (axial) port orientation is undesirable.

This page synthesizes distributor pricing, MPX5100 family cross-reference data and practical design notes not found in the manufacturer datasheet alone, helping engineers compare drop-in equivalents and choose the correct variant for tube-fed differential sensing, MAP-sensing or HVAC pressure-front-end designs.

드롭인 대체품: MPX5100D — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: MPX5100D (동일 폼 팩터 및 풋프린트) — 차이점: Package, Output Type, Accuracy, Operating Temperature, Operating Pressure Range.

NXP Semiconductors
Package: 6-SIP Module (Unibody)
Output Type: Analog, Ratiometric
비교 대상: MPX5100D →
NXP Semiconductors
Package: 6-SIP Module (Case 867B-04)
Output Type: Analog, ratiometric
Operating Pressure Range: 15 kPa to 115 kPa (2.18 PSI to 16.68 PSI)
비교 대상: MPX5100D →
NXP Semiconductors
Package: 6-SIP Module (through-hole)
Output Type: Analog, ratiometric to Vcc
Accuracy: ±2.5% (0 to 85 °C)
비교 대상: MPX5100D →
NXP Semiconductors
Package: 6-SIP Module (through-hole)
Accuracy: 2.5% over compensated range
Operating Temperature: -40 C to +125 C
비교 대상: MPX5100D →
NXP Semiconductors
Package: 6-SIP Module
Output Type: Analog Voltage
Accuracy: ±1.5% (0°C to 85°C)
비교 대상: MPX5100D →
NXP Semiconductors
Package: 6-SIP Module (6-Sensor)
Output Type: Analog voltage (ratiometric)
Accuracy: 2.5% (per NXP product page)
비교 대상: MPX5100D →

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

MPX5100DP

✅ 드롭인
NXP Semiconductors
📦 6-SIP Module (Case 867)
Differential · 0 kPa to 100 kPa (0 to 14.5 PSI) · 5 V (nominal) · 0.2 V to 4.7 V (ratiometric, ~4.5 V span) · Analog, ratiometric to Vcc · ±2.5% (0 to 85 °C) · 45 mV/kPa nominal

✓ 재고 있음

$12.03 / 개

데이터시트 보기 →

MPX5100GP

✅ 드롭인
NXP Semiconductors
📦 6-SIP Module (Case 867)
Vented Gauge · 0 kPa to 100 kPa (0 to 14.5 psi) · 4.75 V to 5.25 V (5 V nominal) · 0.2 V to 4.7 V · 7 mA to 10 mA typical · 4.5 V typical · 2.5% over compensated range · Single axial port, 0.19" (4.93 mm) tube

✓ 재고 있음

$12.03 / 개

데이터시트 보기 →

XGZP6873A-100KPGN

✅ 드롭인
📦 6-SIP Module
third-party differential 0–100 kPa drop-in with same 0.2–4.7 V ratiometric output, manufactured by CFSensor as cross-reference alternative to MPX5100D/MPX5050D/MPX4250D/MPX5500D/MPX5700D/MPX5999D

📋 참조 대체품 (카탈로그에 없음)

MPX5100AP

✅ 드롭인
NXP Semiconductors
📦 6-SIP Module (Case 867)
Absolute · 15 kPa to 115 kPa (2.18 PSI to 16.68 PSI) · 0.2 V to 4.7 V at VCC = 5.0 V · 5.0 V typical (4.75 V to 5.25 V) · 10 mA typical · +/- 2.5% (0 C to 85 C) · 0 C to +85 C

✓ 재고 있음

$12.03 / 개

데이터시트 보기 →
ℹ️ 1 교차 패키지 부품은 숨겨졌습니다 — 다른 패키지는 PCB 재작업이 필요하며 진정한 드롭인 대체품이 아닙니다. 문의하기 교차 패키지 제안이 필요하면 다음을 참조하십시오.

MPX5100D 최대 정격 & 전기적 특성

센서 유형 Piezoresistive Pressure Sensor (Differential)
Pressure Range 0 kPa to 100 kPa (0 PSI to 14.5 PSI)
Pressure Type Differential
공급 전압 4.75 V to 5.25 V
Full-Scale Span 45 mV/kPa typical
출력 유형 Analog Voltage, Ratiometric
출력 전압 범위 0.2 V (zero pressure) to 4.7 V (full-scale)
Accuracy ±1.8 %VFSS maximum
동작 온도 -40 °C to +125 °C
Pressure Port Dual axial tube ports (Differential), 0.19 inch (4.93 mm)
패키지 6-SIP Module (Case 867)
실장 유형 Through-Hole
RoHS 상태 Compliant
Reflow Compatible No (through-hole module)
Media Compatibility Non-corrosive dry gases (filtered dry air recommended)

MPX5100D 핀 구성

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
핀 1 VCC — +5 V supply voltage (4.75 V to 5.25 V)
핀 2 GND — Ground return for sensor and analog output
핀 3 VOUT — Ratiometric analog output (0.2 V to 4.7 V)
핀 4 NC/Test — Unused in normal operation (factory test pin)
핀 5 NC — Not connected (per datasheet)
핀 6 NC — Not connected (per datasheet)

일반적인 애플리케이션

MPX5100D 적합 용도: 6 애플리케이션s: Engine Manifold Absolute Pressure (MAP) Sensing, HVAC Duct Pressure Monitoring, Medical Respiratory / CPAP Equipment, Barometric Air-Pressure / Altitude Reference, Industrial Process Control Loops, Fuel / Hydraulic Line Pressure Sensing.

🚗

Engine Manifold Absolute Pressure (MAP) Sensing

The MPX5100D's 0–100 kPa differential range and 0.2–4.7 V ratiometric output translate cleanly to the standard 0–5 V MAP input channel on most engine control units, when the second port is referenced to sealed manifold vacuum. Piezoresistive sensing keeps response time fast enough to track throttle transients in turbocharged engines, while the on-chip temperature compensation holds accuracy across -40 °C to +125 °C under-hood thermal swings. For automotive AEC-Q100 production programs, the qualified variant of the MPX5100 family should be substituted; the MPX5100D remains appropriate for prototypes and off-road / industrial engines.

🏭

HVAC Duct Pressure Monitoring

Building automation controllers use the MPX5100D to measure static pressure across filters, fans, and variable-air-volume boxes in the 0–100 kPa range typical of commercial ductwork. The 45 mV/kPa sensitivity delivers 4.5 V full-scale swing at 100 kPa, mapping cleanly into a 10-bit 5 V ADC with sufficient resolution for filter-loading alarms and damper feedback. The dual axial port geometry is well suited to tube pickup on rectangular ductwork. Designers adding a 4–20 mA loop stage can use the MPX5100D's output as a low-impedance analog reference, with the XTR105 or XTR110 4–20 mA transmitter ICs referenced on the same analog rail.

💊

Medical Respiratory / CPAP Equipment

Low-cost CPAP, BiPAP and ventilator prototypes use the MPX5100D in conjunction with flow-restriction tubing to derive continuous airway pressure feedback within the 0–100 kPa range. The device's ±1.8 %VFSS accuracy is well within the ±5 % error budget of typical respiratory circuits, and the analog output avoids firmware overhead compared to digital I²C pressure sensors that require a precision clock. The 6-SIP module ports accept standard 0.19 inch medical tubing for direct pneumatic connection. Production medical designs typically migrate to the MPXV7002DP or a dedicated digital sensor after prototyping; the MPX5100D is widely used in the proof-of-concept phase.

✈️

Barometric Air-Pressure / Altitude Reference

Weather stations, drone altimeters and GPS-augmented navigation use the MPX5100D with one port left open to ambient and the other sealed at manufacturing time, giving a differential-to-barometric reference. The ratiometric output remains accurate as long as the 5 V supply is regulated, because span and offset scale together with VCC. Piezoresistive sensors of this family also tend to drift less than 50 mbar/year after the first 100 hours of operation, when housed away from UV and humidity. The MPX5100D is therefore a cost-effective drop-in wherever a 0–100 kPa barometric update rate of 1 Hz or slower is acceptable; for higher-precision altimetry an MPL3115A digital sensor is preferred.

🏭

Industrial Process Control Loops

Process-control PLCs and panel meters accept the MPX5100D's 0.2–4.7 V analog output directly on a 0–5 V analog input module, with the differential measurement eliminating ground-loop noise from long pipe runs in chemical and water-treatment plants. The ±1.8 %VFSS accuracy combined with on-chip temperature compensation removes the requirement for periodic re-calibration in field-deployed cabinets. Designers building a 4–20 mA current loop from this output can pair the MPX5100D with an XTR105 or XTR110 transmitter for compliance with industrial 4–20 mA standards. The 6-SIP module's through-hole pins accept screw-terminal adapters for retrofit installations.

⚡

Fuel / Hydraulic Line Pressure Sensing

Diesel fuel-line monitoring, hydraulic ram pressure sensing and oil-pressure gauge retrofits all share the same 0–100 kPa differential window that the MPX5100D is calibrated for, making it a popular choice for aftermarket gauges and off-road machines. The differential topology allows direct comparison of upstream and downstream pressure taps to compute flow-derived blockage alarms. The 6-SIP tube-port geometry adapts to standard 4.93 mm pneumatic fittings used in hydraulic test rigs. For harsh under-hood thermal environments, the surface-mount MPXV5100GC6U surface-mount equivalent provides similar function without the axial-port constraint.

추천 제품 요약

MC68HC908AZ60A ECU microcontroller reading MAP sensor via ADC 사용처: Engine Manifold Absolute Pressure (MAP) Sensing MC9S12XEP100 Automotive MCU alternative for MAP signal conditioning 사용처: Engine Manifold Absolute Pressure (MAP) Sensing XTR105 4-20 mA transmitter paired with sensor analog output 사용처: HVAC Duct Pressure Monitoring MC9S08GT60A HVAC controller MCU for ADC sampling 사용처: HVAC Duct Pressure Monitoring MPXV7002DP NXP Semiconductors 사용처: Medical Respiratory / CPAP Equipment STM32F051C8T6 ARM Cortex-M0 MCU for respiratory controller 사용처: Medical Respiratory / CPAP Equipment MPL3115A2 Digital altimeter alternative for higher-precision designs 사용처: Barometric Air-Pressure / Altitude Reference MMA8451QR1 Companion accelerometer for inertial reference 사용처: Barometric Air-Pressure / Altitude Reference XTR110 Voltage-to-current loop transmitter paired with sensor output 사용처: Industrial Process Control Loops MC56F8013VFAE NXP Semiconductors 사용처: Industrial Process Control Loops MPXV5100GC6U NXP Semiconductors 사용처: Fuel / Hydraulic Line Pressure Sensing S9KEAZN64AMLK Automotive MCU for gauge driver firmware 사용처: Fuel / Hydraulic Line Pressure Sensing
What is the pressure range of the MPX5100D?
The MPX5100D measures differential pressure from 0 kPa to 100 kPa, equivalent to 0 PSI to 14.5 PSI, per the NXP MPX5100 datasheet. The output is ratiometric and spans 0.2 V at zero differential pressure to 4.7 V at full scale, giving a usable 4.5 V signal swing that drives a 5 V microcontroller ADC directly without external signal conditioning.
Is the MPX5100D the same as the MPX5100DP?
Both parts are members of the NXP MPX5100 family and share identical 0–100 kPa differential sensing, 0.2 V–4.7 V ratiometric output, 45 mV/kPa sensitivity and 4.75 V–5.25 V supply. The MPX5100D uses dual through-hole axial ports (Case 867), while the MPX5100DP uses a single dual-port 0.19 inch tube fitting; both are drop-in interchangeable on the same 5 V analog input front-end when port style is acceptable.
Where can I buy the MPX5100D online?
The MPX5100D is currently stocked at NXP franchised distributors including DigiKey part 951810, with same-day shipment on stocked orders, and at Mouser per the Octopart listing. Pricing as of 2026-10-15 ranges from USD 18.50 at qty 1 to USD 10.75 at qty 1000 on distributor websites; XAIPART also quotes the same family for engineering samples.
What is the lead time for the MPX5100D?
DigiKey typically advertises same-day shipment for the MPX5100D when stock is available, with a lead time of 0 days for stocked units as of 2026-10-15. For bulk orders exceeding distributor stock, factory lead time is approximately 8–12 weeks from NXP; placing a non-stocked MOQ order with the manufacturer is recommended for production ramps and obsolescence risk mitigation.
Is the MPX5100D RoHS compliant?
Yes, the MPX5100D is RoHS compliant per the NXP product page, with lead-free terminal finish and exemption-free construction. It is also REACH compliant for current SVHC declarations. The part is not AEC-Q100 qualified; for automotive under-hood applications the AEC-Q100 grade equivalent should be sourced from the MPX5100 automotive-grade family.
What is the best drop-in replacement for the MPX5100D?
The closest drop-in equivalents are the NXP MPX5100DP (same family, different port orientation), the NXP MPXV5100GC6U (surface-mount 8-pin SOIC variant) and the XGZP6873A-100KPGN from CF Sensor (third-party differential 100 kPa drop-in on the same signal chain). All alternatives share 0.2–4.7 V ratiometric output and 4.75–5.25 V supply for direct PCB-level swap.
MPX5100D vs MPXV5100GC6U — which is better for a board-mount design?
Both share the same 0–100 kPa range, 4.75–5.25 V supply and 0.2–4.7 V ratiometric output, so functionally they are interchangeable. The MPXV5100GC6U is the better choice for surface-mount PCB designs because it uses an 8-pin SOIC with a single top pressure port, while the MPX5100D requires through-hole mounting and a dual axial port geometry. Choose MPX5100D only when tube-fed, vertically-mounted mechanical packaging is needed.
Can the MPX5100D be used as a MAP sensor?
Yes, the MPX5100D's 0–100 kPa differential pressure range and 0.2–4.7 V ratiometric analog output match the input requirement of most engine control units' MAP (manifold absolute pressure) channels, provided the second port is referenced to atmosphere in a sealed manifold. For automotive AEC-Q100 under-hood use, however, an automotive-qualified variant from the NXP MPX5100 automotive family is required; the MPX5100D itself is graded for industrial use.
Where can I download the MPX5100D datasheet PDF?
The official NXP MPX5100 datasheet is available as a free PDF at https://www.nxp.com/docs/en/data-sheet/MPX5100.pdf, covering the MPX5100D, MPX5100DP, MPXV5100GC6U and other family variants. Archived copies of the original Motorola/Freescale datasheet are also mirrored at alldatasheet.com (84245) for reference.
Where can I find the MPX5100D pinout?
The MPX5100D pinout for the 6-SIP module (Case 867) is documented in the NXP MPX5100 datasheet, with pin 1 = VCC (5 V supply), pin 2 = GND, pin 3 = VOUT (analog output), pin 4 = open/test, and pins 5–6 = unused/case connection; detailed pinout diagrams also appear on DigiKey's product page for the part. Always consult the latest revision, as legacy Motorola revisions label pin 4 differently.
What is the MPX5100D price per unit at qty 1000?
As of 2026-10-15 the MPX5100D is listed at approximately USD 10.75 per unit at the qty 1000 break on DigiKey, dropping from USD 18.50 at qty 1. Volume pricing for OEM contracts is typically quoted lower than distributor listing; distributors also accept scheduled orders to lock price and lead time for production ramps and to mitigate obsolescence risk.
When should I choose the MPX5100D over an I²C pressure sensor?
Choose the MPX5100D when the host microcontroller lacks an I²C/SPI port, when a true 5 V analog signal is preferred for noise immunity on long cables, or when the application values the legacy 0.2–4.7 V ratiometric signal chain shared with older industrial instrumentation. Choose an I²C pressure sensor (e.g., BMP280, MPXY8000 family) when board space is at a premium and digital noise immunity on noisy power rails outweighs ease of analog front-end design.
Does the MPX5100D require external signal conditioning?
No, the MPX5100D integrates offset, span and temperature compensation on-chip, so the output pin can drive a microcontroller ADC, a panel meter or a 4–20 mA converter stage directly. External protection (TVS diodes on the pressure ports and a 100 nF + 470 pF decoupling capacitor pair on VCC) is still recommended in electrically noisy industrial environments.
How accurate is the MPX5100D over temperature?
The MPX5100D specifies a maximum accuracy of ±1.8 %VFSS (Voltage Full-Scale Span) across 0 °C to +85 °C, per the NXP MPX5100 datasheet. Over the wider -40 °C to +125 °C industrial range accuracy degrades further, so designers should budget additional ADC-side calibration if the application is exposed to extreme thermal cycling.
What is the difference between MPX5100D and MPX5010D?
Both share the same on-chip signal conditioning architecture and 6-SIP package family, but the MPX5100D measures 0–100 kPa (0–14.5 PSI) while the MPX5010D measures 0–10 kPa (0–1.45 PSI), giving the MPX5010D ten times higher mV/kPa sensitivity for low-pressure applications. Use the MPX5100D for HVAC and engine-vacuum pressures; use the MPX5010D for very low pressure drops such as airflow or filtration monitoring.

엔지니어링 참조 데이터: MPX5100D — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the MPX5100D when the application needs a true differential pressure measurement in the 0–100 kPa window, with on-chip signal conditioning that lets a 5 V microcontroller ADC read the output with no extra op-amps. Choose the MPX5100DP if you need the same die but with a single-port tube fitting rather than dual axial ports; choose the MPX5100GP gauge variant when one side can be vented to atmosphere. For surface-mount designs without axial ports, move to the MPXV5100GC6U in SO-8. For pure barometric / altimeter use, an I²C digital part such as MPL3115A2 generally offers higher resolution and oversampling, while the MPX5100D remains the better fit for analog panel meters or 4–20 mA loop transmitters built around an XTR105 / XTR110.

대체품과의 비교

파라미터 이 제품 MPX5100DP MPXV5100GC6U MPX5100GP XGZP6873A-100KPGN MPX5100AP
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors CFSensor (third-party) NXP Semiconductors
Package 6-SIP Module (Case 867) 6-SIP Module (Case 867) - same SO-8 (8-SMD) 6-SIP Module (Case 867) - same 6-SIP Module - same 6-SIP Module (Case 867) - same
Pressure Type Differential Differential Differential Gauge Differential Absolute
Pressure Range 0–100 kPa (0–14.5 PSI) 0–100 kPa (0–14.5 PSI) 0–100 kPa (0–14.5 PSI) 0–100 kPa (0–14.5 PSI) 0–100 kPa 0–100 kPa (0–14.5 PSI)
Supply Voltage 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 5 V (typical) 4.75 V to 5.25 V
Output Range 0.2 V to 4.7 V (ratiometric) 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V
Sensitivity 45 mV/kPa typical 45 mV/kPa 45 mV/kPa 45 mV/kPa 45 mV/kPa 45 mV/kPa

주요 차별점

  • Differential topology at the lowest cost in the MPX5100 family (vs MPX5100GP)
  • Through-hole 6-SIP with axial ports for tube-fed installs (vs MPXV5100GC6U)
  • Pure analog output without digital clock overhead (vs BMP280 / MPL3115A2 digital pressure sensors)

설계 노트

Place a 100 nF ceramic decoupling capacitor as close as possible to pin 1 (VCC) and a parallel 470 pF high-frequency bypass to suppress switching noise from digital logic sharing the same 5 V rail. The MPX5100D is ratiometric, so any noise or ripple on VCC appears directly on the output; using a linear regulator (LP2985-5.0, LM7805) instead of a switching converter for the analog 5 V rail preserves the 4.5 V signal swing accuracy.

Keep pneumatic tubes on the dual axial pressure ports as short as practical and orient them vertically downward so condensate cannot pool on the sensing die. Add a small in-line particulate filter (typically 5 µm) ahead of each port if the media is unfiltered ambient air, water vapor or oil mist. For electrically noisy industrial enclosures, place a TVS diode across each port to ground to protect the die from voltage transients induced by long cable runs.

The output is an analog ratiometric signal with finite 5 kΩ source impedance; buffer the output with an op-amp (MCP6001, TLV2371) when driving a long cable, a slow ADC with a high-impedance input, or an RC low-pass filter. Estimated: a 10 kΩ + 100 nF RC network at the output gives a ~1 ms time constant suitable for HVAC pressure-loop control; for engine MAP sensing where bandwidth is critical, remove the filter and let the MCU ADC sample at ≥1 kSPS.

Do not apply pressure beyond 200 kPa (over-range) and do not allow liquid water to reach the sensing die; the MPX5100D is specified for non-corrosive dry gases only. Also, the MPX5100D is NOT AEC-Q100 qualified, so for automotive under-hood production use the AEC-Q100-graded variant of the MPX5100 family. The differential output at 0 kPa is 0.2 V minimum (not 0 V); reserve this offset in any software calibration routine.

규정 준수 정보

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
무연
Yes
무할로겐
Yes
분쟁 광물
Compliant

RoHS compliant per NXP product page. Not AEC-Q100 qualified; for automotive under-hood use, source the AEC-Q100 equivalent from the NXP MPX5100 family. Reach and conflict-mineral declarations available from NXP.

데이터 검증일: 2026-10-15 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

MPX5100D datasheet MPX5100D pressure sensor MPX5100D differential 100 kPa MPX5100 vs MPX5100DP NXP MPX5100 pinout 6-SIP MPX5100D MAP sensor application MPX5100D price buy online MPX5100D vs MPXV5100GC6U 0 to 100 kPa pressure transducer 0.2V to 4.7V MPX5100D drop-in replacement piezoresistive silicon pressure sensor 6-SIP MPX5100D HVAC barometric altimeter what is the output voltage of MPX5100D MPX5100D lead time stock

관련 부품 & 용어

NXP Semiconductors MPX5100D MPX5100DP MPXV5100GC6U MPX5100GP MPX5100AP XGZP6873A-100KPGN piezoresistive pressure sensor differential pressure sensor gauge pressure sensor MEMS transducer analog ratiometric output PWM signal AEC-Q100 RoHS REACH SIP-6 module Case 867 MAP sensor engine control unit HVAC duct pressure altimeter / barometer on-chip signal conditioning temperature compensation factory calibration
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기