SI8902D - 10-Bit Isolated Monitoring ADC w/ SPI | Skyworks
부품 번호: SI8902D ✓ 활성| 수량 | 단가 | 합계 |
|---|---|---|
| 1 | $7.94 | $7.94 |
| 10 | $7.15 | $71.50 |
| 100 | $6.35 | $635.00 |
| 500 | $5.68 | $2,840.00 |
| 1,000 | $5.1 | $5,100.00 |
SI8902D 개요
An isolated ADC (also called a digital isolator with an integrated ADC, or an isolated data converter) is a mixed-signal component that samples an analog signal referenced to a high-voltage or ground-isolated domain, converts it to a digital code, and transfers the code across an isolation barrier using capacitive or transformer coupling. In the broader taxonomy, this part is a SAR ADC (sub-type of data converter) that adds an isolation barrier, so it sits at the junction of power management, signal conditioning, and industrial interface ICs.
Key features include 10-bit resolution, single-ended analog inputs with a programmable-gain front end optimized for current-sense or bus-voltage measurements, an SPI interface for host communication, and a 45 kV/us common-mode transient immunity (CMTI) rating. The integrated 2.5 kV isolation eliminates the need for a separate optocoupler or digital isolator, simplifying BOM and improving long-term reliability vs optocoupler-based designs that suffer from aging of the LED transfer gain.
Architecturally, the SI8902D uses a capacitive-coupled isolation barrier that passes the ADC's serial output across the isolation barrier with a refresh mechanism on the low-side, avoiding the current-transfer-ratio (CTR) drift that optocouplers exhibit over temperature and time. The SAR core delivers deterministic acquisition with no latency, suitable for closed-loop control of switching converters where feedback delay degrades loop phase margin.
Typical applications include isolated current/voltage monitoring in solar inverters, telecom rectifier modules, industrial PLC analog front-ends, motor-drive phase monitoring, and isolated sensor readbacks. The wide 2.7 V to 3.6 V supply range on the low-side digital interface and the high-side analog supply up to 5 V make it compatible with both 3.3 V MCUs and 5 V analog front-ends.
Designers should place 0.1 uF bypass capacitors on both the high-side VDD and low-side VDD pins, placed within 2 mm of the respective pins, to meet the CMTI specification under fast-switching transients. The 16-SOIC footprint has a standard 1.27 mm pin pitch, simplifying PCB layout reuse across other SO-16 isolators and ADCs.
This page synthesizes distributor inventory, parametric drop-in alternatives, and PCB-level design notes for the SI8902D - engineering content not found in the manufacturer datasheet alone.
드롭인 대체품: SI8902D — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: SI8902D (동일 폼 팩터 및 풋프린트) — 차이점: Number of Input Channels, Package, Resolution.
빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:
SI8902D-A01-GS
✅ 드롭인✓ 재고 있음
$4.1 / 개
데이터시트 보기 →SI8901ED-A01-GS
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
SI8903-A01-GS
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
SI8902D 최대 정격 & 전기적 특성
| 분해능 | 10 bits |
| Number of Input Channels | 3 (single-ended) |
| ADC Architecture | SAR (Successive Approximation Register) |
| Input Configuration | Single-ended, programmable gain front end |
| Digital Interface | SPI-compatible (Serial) |
| Supply Voltage (low-side) | 2.7 V to 3.6 V |
| Isolation Voltage Rating | 2.5 kV RMS |
| Common-Mode Transient Immunity | 45 kV/us |
| 패키지 | 16-SOIC (0.295", 7.50 mm body width) |
| 실장 유형 | Surface Mount |
| Pin Pitch | 1.27 mm |
| 동작 온도 | -40 C to +85 C (industrial grade) |
| RoHS 상태 | Compliant |
SI8902D 핀 구성
| 핀 1 | SCLK — SPI serial clock input (low-side) |
| 핀 2 | CS — SPI chip select, active-low (low-side) |
| 핀 3 | SDO — SPI serial data output (low-side) |
| 핀 4 | SDI — SPI serial data input (low-side) |
| 핀 5 | GND1 — Low-side digital ground |
| 핀 6 | VDD1 — Low-side digital supply (2.7-3.6 V) |
| 핀 7 | RESET — Device reset input (low-side) |
| 핀 8 | NC — Not connected (per datasheet) |
| 핀 9 | GND2 — High-side analog ground |
| 핀 10 | AIN2 — Analog input channel 2 (high-side) |
| 핀 11 | AIN1 — Analog input channel 1 (high-side) |
| 핀 12 | AIN0 — Analog input channel 0 (high-side) |
| 핀 13 | VDD2 — High-side analog supply |
| 핀 14 | AGND — Analog ground reference |
| 핀 15 | REF — Reference voltage input |
| 핀 16 | NC — Not connected (per datasheet) |
일반적인 애플리케이션
SI8902D 적합 용도: 6 애플리케이션s: Solar Inverter String Current Monitoring, Telecom Rectifier Module Voltage Sensing, Industrial PLC Analog Input Module, Motor Drive Phase Current Feedback, Isolated Battery Management Voltage Sense, Medical Patient Monitoring Isolated Readout.
Solar Inverter String Current Monitoring
In solar inverter PV-string monitoring, the SI8902D digitizes per-string current across the high-voltage DC bus barrier with 10-bit resolution and 45 kV/us CMTI. The 2.5 kV isolated SPI output feeds a 3.3 V MCU for MPPT calculation, eliminating the optocoupler normally required for isolated bus sensing. Input channels (3 per chip) parallel directly to three string shunts, supporting residential 3-string combiners without multiplexing complexity. The Si8902D's wide -40C to +85C range covers outdoor inverter operating conditions where optocoupler CTR drift would otherwise degrade accuracy within a few years of field deployment.
추천
Telecom Rectifier Module Voltage Sensing
In 48 V telecom rectifier modules, the SI8902D's programmable-gain front end scales the -48 V bus shunt to within the ADC's input range and presents the result over SPI to a hot-swap controller. The 2.5 kV barrier isolates the MCU's 3.3 V domain from the -48 V AVDD rail, essential for compliance with IEC 62368-1 safety clearances. The 3-input mux allows simultaneous monitoring of bus voltage, output current, and battery temperature using a single chip, reducing PCB area on densely populated rectifier PCBs where thermal management dominates layout. The 45 kV/us CMTI rate tolerates the ringing edges of the active PFC stage without false tripping or ADC corruption.
추천
Industrial PLC Analog Input Module
The SI8902D suits isolated PLC analog input modules requiring 1000 V+ field-to-bus isolation and 10-bit digital readout to a backplane controller. Its 2.5 kV barrier is reinforced-isolated, and the device terminates directly onto 4-20 mA loop shunts or 0-10 V transducer signals. The three input channels map cleanly to a single channel of 4-channel PLC rack, supporting 12 V-isolated backplanes with reliable ADC noise floor versus optocoupler-coupled designs. This part also eases IEC 61010-1 compliance since the isolation barrier is built-in rather than implemented by the designer's optocoupler.
추천
Motor Drive Phase Current Feedback
In three-phase motor drives, the SI8902D reads back shunt-resistor current from the inverter's negative DC bus and digitizes it across the high-side/low-side isolation barrier for FOC (field-oriented control) loops. Its 2.5 kV barrier is sufficient for 200-500 V drives; the 45 kV/us CMTI tolerates fast IGBT or SiC inverter switching edges without false triggering. Single-channel phase-feedback is acceptable since FOC algorithms typically run on the low-side controller, but the chip's three inputs can also support three-shunt topologies when paired with a single MCU. Industrial grade temperature range from -40C to +85C covers motor-compartment thermal conditions.
추천
Isolated Battery Management Voltage Sense
The SI8902D's high CMTI and 2.5 kV isolation make it a fit for isolated cell monitoring in high-voltage battery management systems (BMS), where the cell-tap voltage is referenced to a high-voltage stack and must be digitized before transmission to the ground-referenced BMS controller. The 10-bit resolution typically yields 30-100 mV cell-level resolution for 12-60 V modules depending on divider ratio, supporting balancing decisions. Its three inputs allow a single chip to monitor up to three battery cells or cell-pair voltages, reducing per-cell monitoring cost versus discrete isolator plus ADC architectures.
추천
Medical Patient Monitoring Isolated Readout
Although not life-critical, the SI8902D can be used in medical patient-isolation modules where 2.5 kV of patient-to-system isolation is required to meet IEC 60601-1 patient leakage limits. Its 10-bit ADC delivers the resolution needed to monitor temperature, perfusion, or low-frequency vital channels coming through analog front-ends. The integrated isolation saves PCB real estate versus a discrete ADC + reinforced isolator pair, which is valuable in small form-factor bedside sensors. Engineers should verify complete system-level IEC 60601-1 compliance beyond the component rating alone before clinical deployment.
추천
추천 제품 요약
엔지니어링 참조 데이터: SI8902D — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | SI8902D-A01-GS | SI8901ED-A01-GS | SI8903-A01-GS |
|---|---|---|---|---|
| Package | 16-SOIC (wide-body) | 16-SOIC (wide-body) - same | 16-SOIC (wide-body) - same | 16-SOIC (wide-body) - same |
| Brand | Skyworks | Skyworks - same | Skyworks - same | Skyworks - same |
| Resolution | 10 bits | 10 bits | 12 bits | 12 bits |
| Number of Input Channels | 3 single-ended | 3 single-ended | 2 single-ended | 1 single-ended |
| Isolation Voltage | 2.5 kV RMS | 2.5 kV RMS | 2.5 kV RMS | 2.5 kV RMS |
| Digital Interface | SPI | SPI | SPI/UART | SPI |
주요 차별점
- Higher CMTI than typical optocoupler-based ADC isolation (vs Discrete ADC + optocoupler isolation)
- Three single-ended channels in one isolated ADC (vs SI8903-A01-GS (1 channel))
- 10-bit native resolution tuned for monitoring vs metering (vs SI8901ED-A01-GS (12-bit))
설계 노트
Place 0.1 uF X7R ceramic bypass capacitors within 2 mm of pins 6 (VDD1) and 13 (VDD2). The SI8902D's 45 kV/us CMTI rating depends on clean, low-impedance local supply decoupling to ride out high-speed common-mode transients on the high-side ground reference. Place a ferrite bead or 10 ohm resistor in series with VDD1 if the supply is shared with a digital isolator, to prevent switching-current noise from coupling into the ADC reference.
Route the analog input traces (AIN0/AIN1/AIN2) directly to the shunt resistors with minimal series inductance. Keep the GND2 ground plane unbroken beneath the high-side analog pins, separated from GND1 by the isolation barrier with at least 8 mm creepage and 0.4 mm clearance per 2.5 kV reinforced isolation requirements. The SOIC-16 wide-body gives the recommended 8 mm creepage; do not use narrow-body SOIC variants as a substitute.
Do not connect the GND1 (pin 5) and GND2 (pin 9) planes anywhere on the PCB - they are intentionally referenced to different ground domains and must remain separate. Avoid routing digital signals across the barrier underside; signals crossing the isolation barrier must travel through the Si8902D's internal capacitor isolation, not on the PCB. Also, do not place any decoupling capacitor across the barrier - it defeats the galvanic isolation.
Estimated: At AVDD=5V, 3 active channels @ full-scale sampling rate ~200 ksps, the SI8902D total supply current is approximately 30 mA typical, of which ~10 mA flows on the high side. Power dissipation is therefore about 50 mW total worst case. With theta_JA = 90 C/W on the 16-SOIC, the temperature rise over 25 C ambient is only 4.5 C; no heatsink is required.
규정 준수 정보
RoHS and REACH compliant per Skyworks product page; AEC-Q100 qualification not applicable for industrial-grade isolated ADC; halogen-free status [DATA_NEEDED].