VSC8562XKS-14 - Dual-Port GbE PHY | Microchip | Ethernet
부품 번호: VSC8562XKS-14 ✓ 활성VSC8562XKS-14 개요
A Gigabit Ethernet PHY is the physical-layer component that converts digital data into electrical or optical signaling for a Gigabit Ethernet link. Within a network interface hierarchy, the PHY connects a digital Ethernet controller or switch to copper or fiber media. The VSC8562 integrates two Gigabit Ethernet ports, providing a compact multi-port solution for enterprise switching, industrial communication, cloud infrastructure, smart-grid equipment, video systems, and secure government or enterprise networks.
The device combines dual copper or fiber ports with QSGMII connectivity and MACsec support. QSGMII provides a high-speed serial interface between a PHY and a switching or processing device. MACsec capabilities support hardware-assisted protection of Ethernet traffic at layer 2. Together, these functions target designs that require two Gigabit Ethernet links, efficient serial interconnection, and integrated traffic-security capability within one device.
The VSC8562 uses Microchip's Intellisec technology for securing cloud-network applications. This positioning is significant because enterprise, government, database, collaboration, smart-grid, and industrial systems may require Ethernet security without implementing every protected link through discrete components. Integrating two PHY ports in one package also reduces board-level PHY count compared with separate single-port devices, although a complete design still requires careful power, clock, signal-integrity, and thermal implementation.
Typical installations include access-switch line cards, industrial Ethernet gateways, network-interface modules, video infrastructure, smart-grid controllers, and cloud-network appliances. Each port can support copper or fiber connectivity according to the implementation and external network interface requirements. Product selection should be confirmed against the manufacturer datasheet for supported media, electrical characteristics, clocking, firmware configuration, refclk requirements, and PCB layout constraints.
The main design consideration is that this highly integrated transceiver still requires a carefully engineered PCB. Differential Ethernet pairs, high-speed serial QSGMII links, reference clocks, power rails, decoupling networks, and the exposed-package thermal path must be routed according to the manufacturer's recommended layout. Differential pair geometry and return paths are especially important because incorrect impedance or coupling can reduce signal integrity despite correct logical configuration.
This product page consolidates the verified ordering information, functional identity, package format, sourcing guidance, and design-focused context for the VSC8562XKS-14. It also distinguishes confirmed characteristics from parameters that require confirmation in the Microchip datasheet, helping engineers plan the PCB, power architecture, media interfaces, and compliance work before releasing a production design.
드롭인 대체품: VSC8562XKS-14 — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 제품에는 사용 가능한 드롭인 대체품이 없습니다.
대체품 요청VSC8562XKS-14 사양
| Product Type | Dual-port Gigabit Ethernet physical-layer transceiver |
| Ethernet Ports | 2 ports |
| Supported Media | Copper and fiber |
| Serial Interface | QSGMII |
| Security Capability | MACsec |
| Product Family | VSC8562 |
| 패키지 | 256-pin PBGA |
| Package Dimensions | 17 x 17 mm |
| Temperature Classification | Industrial temperature |
| 실장 유형 | Surface mount |
VSC8562XKS-14 17 x 17 mm 핀 구성 가이드
VSC8562XKS-14(17 x 17 mm 패키지)의 핀 구성입니다. 핀 번호, 기능, 연결 다이어그램은 제조사 데이터시트에 정의되어 있습니다. 정확한 풋프린트와 솔더링 지침은 해당 문서를 참조하십시오.
다음에 대한 상세 핀아웃 데이터 없음: VSC8562XKS-14.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
VSC8562XKS-14 적합 용도: 6 애플리케이션s: Industrial Ethernet Gateway, Enterprise Access-Switch Line Card, Smart-Grid Communications Controller, Secure Cloud-Network Appliance, Video and Surveillance Network Node, Enterprise Collaboration Endpoint.
Industrial Ethernet Gateway
The VSC8562XKS-14 fits dual-port industrial gateways that must bridge copper and fiber networks while adding protected Ethernet traffic handling. Its two GbE PHY ports reduce the number of separate physical-layer devices required for a gateway with redundant or copper-to-fiber connectivity. The QSGMII interface provides a high-speed serial link to a switching or processing block, while MACsec supports hardware-assisted layer-2 protection. The industrial-temperature classification is appropriate for gateways installed in controlled enclosures. Final qualification still requires confirmation of temperature limits, isolation, surge immunity, and environmental standards for the finished equipment.
Enterprise Access-Switch Line Card
The VSC8562XKS-14 is suited to compact access-switch line cards where each module must provide two Gigabit Ethernet ports with copper and fiber choices. Integrating the dual-port PHY with QSGMII allows the line card to use a high-speed serial connection to a switching ASIC rather than exposing an entire parallel data bus across the PCB. MACsec support is valuable where traffic protection must be applied at the physical interface. Designers should plan controlled-impedance routing, isolated magnetic or optical media interfaces, reference-clock distribution, and adequate thermal paths around the 17 x 17 mm PBGA.
Smart-Grid Communications Controller
The VSC8562XKS-14 can support smart-grid communication controllers that connect field equipment through both copper and fiber networks. Two integrated GbE PHY ports are useful where a controller interfaces with local meters, substations, or remote monitoring equipment while also providing an uplink. MACsec can protect communications when the system architecture requires hardware-assisted Ethernet security, although keys, policy, and host-side control remain part of the complete design. Industrial-temperature classification supports equipment deployment, but operating-temperature and isolation requirements must be checked against the specific grid-product standard.
Secure Cloud-Network Appliance
The VSC8562XKS-14 is positioned for cloud-network appliances that need secure dual-GbE connectivity. A server, storage, or collaboration system can use the QSGMII interface for efficient connection to a network processor, while the two PHY ports handle copper and fiber access links. MACsec and Intellisec-oriented security functions make the device relevant to enterprise and government communication paths. The integrated design can simplify media-interface partitioning, but designers must verify firmware support, security configuration, thermal performance, and exact electrical limits before selecting it for a production appliance.
Video and Surveillance Network Node
The VSC8562XKS-14 fits network nodes that distribute or aggregate video traffic over copper and fiber links. Its dual GbE ports can support a camera-facing connection and an upstream trunk, or two independent network segments. QSGMII provides a suitable high-speed path to an embedded switching or processing engine, helping keep the external network interface organized around serial links. MACsec support may assist security-sensitive deployments, although the complete camera system must establish identity, key management, and policy. Layer placement, return paths, and impedance control remain critical for reliable video transport.
Enterprise Collaboration Endpoint
The VSC8562XKS-14 can be integrated into enterprise collaboration endpoints requiring two Gigabit Ethernet connections and protected network traffic. The dual copper/fiber PHY arrangement is useful for endpoints that offer both electrical and optical network options, while QSGMII connects the PHY block to a host processor or network controller. MACsec enables hardware-assisted protection for suitable Ethernet links. Because the device is a complex 256-pin PBGA, the design must include meticulous power-plane segmentation, low-noise decoupling, reference-clock routing, and package-aware thermal analysis to preserve network performance.
엔지니어링 참조 데이터: VSC8562XKS-14 — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 |
|---|---|
| Brand | Microchip Technology |
| Package | 256-pin PBGA (17 x 17 mm) |
| Port Count | 2 |
| Ethernet Speed | Gigabit Ethernet |
| Media Support | Copper and fiber |
| Host Serial Interface | QSGMII |
| Security Feature | MACsec |
| Temperature Classification | Industrial temperature |
| Mounting Type | Surface mount |
주요 차별점
- Two-port media integration in one transceiver (vs A discrete dual-PHY implementation)
- High-speed QSGMII host connection (vs A parallel-interface PHY arrangement)
- Integrated Ethernet traffic protection (vs A PHY design without integrated MACsec)
- Industrial-oriented ordering configuration (vs A commercial-temperature VSC8562 configuration)
설계 노트
Treat the 256-pin PBGA as a mixed-signal, high-speed design rather than a conventional digital IC. Route Ethernet differential pairs and QSGMII links as controlled-impedance nets with continuous reference planes, short vias, appropriate length matching, and no plane splits beneath the device. Keep copper-media magnetics or fiber-interface circuitry close to the relevant PHY balls, and follow the manufacturer stack-up and ball-escape guidance. Because the exact ball functions and recommended layer stack are not reproduced here, verify them in the Microchip datasheet before PCB release.
Separate and decouple the PHY's core, analog, and digital supply domains as directed by the manufacturer datasheet. Place bulk and high-frequency capacitors close to their assigned power balls, provide short return paths, and avoid sharing noisy return-current routes with Ethernet and QSGMII signaling. The exact voltage rails, capacitor values, sequencing requirements, and permissible ripple must be taken from the manufacturer documentation. Validate startup, load transitions, and supply noise with the final PHY, clock source, media interface, and switching or host device.
Plan thermal relief and heat spreading beneath and around the 17 x 17 mm PBGA from the beginning of layout. The 256-ball package exposes many connections and may require a multilayer board to route high-speed interfaces while maintaining thermal performance. Use the manufacturer's thermal model and recommended via pattern, preserve copper where practical, and confirm junction-temperature margin at the highest expected ambient temperature and traffic load. A plastic PBGA construction can limit top-side heat removal, making the bottom-layer thermal path and enclosure airflow especially important.
Design reference-clock distribution, Ethernet differential pairs, and QSGMII interfaces as separate high-speed subsystems. Use low-jitter clock sources, maintain the required impedance and spacing, and minimize stubs from test points, connectors, and optional circuitry. Keep analog copper or fiber media paths away from noisy digital and switching paths. After schematic completion, perform pre-layout signal-integrity and power-integrity analysis with actual stack-up, connector models, and enclosure assumptions; this step is especially valuable for dual-port designs where channel-to-channel skew can affect interoperability.
규정 준수 정보
Compliance declarations and qualification records are not stated in the product information for this exact ordering code. Confirm the manufacturer declarations and the requirements of the finished equipment before making a compliance claim.