Analog Devices

AD9553BCPZ - 810MHz PLL Clock Translator | Analog Devices

MPN: AD9553BCPZ ✓ Aktif
32-LFCSP-WQ, 5 mm x 5 mm Package 810 MHz Speed
MOQ: 1 |

AD9553BCPZ Ringkasan

The Analog Devices AD9553BCPZ is an integer-N PLL-based clock translator capable of operating to 810 MHz with one clock output in a 32-LFCSP-WQ package measuring 5 mm by 5 mm. It accepts up to two single-ended reference signals through REFA and REFB, or one differential reference input. The device is designed for applications requiring flexible frequency translation across passive optical network, base-station, Ethernet, SONET/SDH, and T1/E1 clock systems.

A clock translator is a timing semiconductor that converts or redistributes reference frequencies while maintaining a controlled relationship between input and output signals. Clock translators occupy the clock-and-timing hierarchy alongside clock generators, buffers, multipliers, dividers, phase-locked loops, and jitter-control devices. The AD9553 uses a phase-locked loop to perform its frequency translation, allowing system designers to derive a required service or transport clock from an available reference rather than adding another dedicated oscillator.

The AD9553BCPZ provides a maximum listed operating frequency of 810 MHz and one output. Its integer-N PLL architecture accommodates the frequency-translation requirements associated with optical-access and telecommunications infrastructure. Two reference options broaden board-level flexibility: engineers may drive REFA and REFB separately with single-ended sources or use one differential reference arrangement. This makes the device useful in equipment where reference clocks originate from different upstream line cards or synchronization modules.

Its clock-generation role is especially relevant in base stations and passive optical networks, where accurate timing alignment affects downstream transport links and service synchronization. Ethernet, SONET/SDH, and T1/E1 equipment can also use programmable clock translation to reconcile reference-clock domains. The 32-LFCSP-WQ package supports compact placement in communications and networking hardware, although careful PCB layout and thermal management remain necessary for reliable high-frequency performance.

Typical deployments include GPON line terminals and central-office equipment, cellular base-station clocking, carrier Ethernet timing subsystems, optical transport modules, and telecommunications test equipment. In each case, the AD9553 is positioned between reference-clock sources and the timing distribution network, with configuration and loop-filter components determining the translation ratio and phase behavior.

The primary design consideration is the relationship between reference frequency, translation ratio, PLL loop bandwidth, output jitter, and the timing budget of the receiving equipment. Reference traces should be short and properly terminated, while power and ground planes should provide low-impedance return paths. Unused reference inputs require deliberate treatment rather than being left without a defined termination condition.

This product overview combines the manufacturer’s functional description with package, interface, and application guidance. It also identifies the engineering constraints that matter when planning a clock translator design, including reference selection, PLL configuration, high-frequency layout, and qualification of genuine drop-in alternatives rather than merely similar clock ICs.

Pilihan pengganti yang segera untuk AD9553BCPZ — sama paket, pin-pin kompatibel. Bahagian paket yang berbeza memerlukan kerja ulang PCB diasingkan.

Tiada pilihan pengganti yang segera untuk produk ini.

Minta Alternatif

AD9553BCPZ Spesifikasi

Product Type Integer-N PLL clock translator
Maximum Operating Frequency 810 MHz
Output Count 1 output
PLL Architecture Integer-N phase-locked loop
Reference Input Configuration Up to 2 single-ended inputs or 1 differential input
Reference Inputs REFA and REFB
Kemasan 32-LFCSP-WQ, 5 mm x 5 mm
Jenis Pemasangan Surface mount

Panduan Konfigurasi Pin AD9553BCPZ 32-lfcsp-wq, 5 mm x 5 mm

Konfigurasi pin untuk AD9553BCPZ (32-lfcsp-wq, 5 mm x 5 mm pakai). Penomeran pin, fungsi, dan garis bentuk koneksi ditakrifkan dalam dokumen pengeluar. Rujuk dokumen untuk kebentuk dan pedoman pengasman.

Garis bentuk pengecah pakai 32-lfcsp-wq, 5 mm x 5 mm untuk AD9553BCPZ

Tiada data garisan pin yang diperoleh untuk AD9553BCPZ.

Rujuk kepada lembaran data untuk konfigurasi pin penuh.

Aplikasi Biasa

AD9553BCPZ patut untuk 6 aplikasis: GPON Passive Optical Network Timing, Cellular Base-Station Clocking, Carrier Ethernet Timing Translation, SONET/SDH Optical Transport, T1/E1 Line-Side Clocking, Telecommunications Test Equipment.

🌐

GPON Passive Optical Network Timing

The AD9553BCPZ fits GPON infrastructure because it translates an available reference clock through an integer-N PLL and can operate to 810 MHz. The device accepts two single-ended references on REFA and REFB or one differential reference, allowing the central-office design to reuse a synchronization source already distributed through the line-card architecture. Its single-output arrangement is appropriate when one translated clock must feed the next timing stage. Engineers should select the reference and divider values so that the resulting output meets the PON subsystem’s timing and jitter budget. The 32-LFCSP-WQ package also supports compact placement in line-terminal and central-office equipment, but differential routing, reference termination, and a continuous ground reference remain essential at high clock rates.

🏗️

Cellular Base-Station Clocking

The AD9553BCPZ is suited to base-station timing because it provides an integer-N PLL-based translation function with a maximum operating frequency of 810 MHz. Instead of introducing another free-running oscillator for each internal clock domain, a base-station design can derive the required clock from an existing reference through REFA or REFB. The flexible single-ended and differential reference options support different synchronization architectures. With one output, the translated clock can feed the receiver, transmitter, or processing chain that requires it. Selection should be based on the resulting output frequency and jitter rather than the 810 MHz headline value alone, while PCB implementation must preserve short reference paths and an uninterrupted return path beneath the clock network.

🌐

Carrier Ethernet Timing Translation

The AD9553BCPZ can support carrier Ethernet equipment that needs a deterministic frequency relationship between a system reference and a downstream timing domain. Its integer-N PLL architecture performs clock translation to a maximum operating frequency of 810 MHz, while the flexible reference interface accepts either two single-ended sources or one differential clock. This allows synchronization to be routed from an existing timing hierarchy instead of requiring a dedicated converter at every interface. The single output is suitable for feeding a downstream transceiver, digital processing block, or clock-distribution stage. Practical design work should verify divider selection, reference phase alignment, output-jitter contribution, and termination of unused reference pins using the manufacturer’s guidance before treating the translated clock as a drop-in timing source.

🔧

SONET/SDH Optical Transport

The AD9553BCPZ is appropriate for SONET/SDH transport systems that reconcile a reference clock with the timing required by line-card circuitry. The part translates reference frequencies through an integer-N PLL and supports operation to 810 MHz, making it relevant to high-speed transport timing architectures. Two single-ended reference inputs or one differential reference provide flexibility in how the equipment receives synchronization from a higher-level network. Its one-output configuration supports a clean division of responsibility: the AD9553 creates the translated clock, and downstream distribution or transceiver circuitry fans it out. Board implementation should prioritize controlled impedance, short clock routes, solid plane connections, and proper treatment of an unused REFA or REFB input so that the PLL receives predictable reference conditions.

📡

T1/E1 Line-Side Clocking

The AD9553BCPZ can be used in T1/E1 equipment when the line-card timing domain must be translated from a common system reference. Although the device is specified for communications-clock translation up to 810 MHz, its actual utility in a T1/E1 design depends on the selected reference, integer-N ratio, and resulting output-frequency accuracy. The flexible reference interface allows either separate single-ended sources or a differential reference to feed the PLL. A single translated output can then serve the line interface or a related timing block. Designers should evaluate phase behavior, jitter, reference noise, and loop stability against the line interface requirements rather than assuming the maximum frequency alone guarantees a timing-compatible solution.

🖥️

Telecommunications Test Equipment

The AD9553BCPZ is useful in telecommunications test equipment that must synthesize a clock from a controlled reference while preserving a predictable frequency relationship. Its integer-N PLL architecture, operation to 810 MHz, and one-output configuration make it suitable for embedded timing-generation blocks in transport analyzers, interface testers, and line-card simulators. REFA and REFB can accept two single-ended sources or the circuit can use one differential reference, allowing the test instrument to accommodate multiple synchronization architectures. The compact 32-LFCSP-WQ package helps preserve instrument density. For dependable measurements, the reference source should be clean, the output configuration must meet the instrument’s jitter and phase requirements, and PCB layout should minimize clock-distribution loss before the signal reaches the test circuitry.

Ringkasan Produk Disebarkan

AD9553/PCBZ AD9553 family timing evaluation board Dipergunakan di: GPON Passive Optical Network Timing, Cellular Base-Station Clocking, Carrier Ethernet Timing Translation, SONET/SDH Optical Transport, T1/E1 Line-Side Clocking, Telecommunications Test Equipment AD9553 AD9553 clock-translator family Dipergunakan di: GPON Passive Optical Network Timing, Cellular Base-Station Clocking, Carrier Ethernet Timing Translation, SONET/SDH Optical Transport, T1/E1 Line-Side Clocking, Telecommunications Test Equipment
What is the AD9553BCPZ?
The AD9553BCPZ is an integer-N phase-locked-loop clock translator operating to 810 MHz with one output in a 32-LFCSP-WQ package. According to the Analog Devices manufacturer product page, it is intended for passive optical network, base-station, Ethernet, SONET/SDH, and T1/E1 timing systems. The PLL architecture translates an available reference frequency into a clock required by the receiving timing subsystem.
What is the operating frequency of the AD9553BCPZ?
The AD9553BCPZ has a listed maximum operating frequency of 810 MHz and provides one clock output. This maximum describes the device’s operating capability, not a guaranteed output frequency for every divider configuration. The actual output range also depends on the selected reference frequency, integer-N translation ratio, PLL settings, and the electrical limits stated in the manufacturer datasheet.
Where can I download the AD9553BCPZ datasheet PDF?
The official AD9553 datasheet and product information are available from the Analog Devices product page at https://www.analog.com/en/products/ad9553.html. That page provides the authoritative device description and links to technical documentation. For a complete pin-by-pin design, use the manufacturer’s pin-description table and verify the 32-LFCSP-WQ land pattern before laying out or modifying a PCB.
Where can I find the AD9553BCPZ pinout?
The AD9553BCPZ pinout is defined by the manufacturer’s AD9553 datasheet, which covers the 32-LFCSP-WQ package. Use the pin-description table to assign REFA, REFB, power, ground, control, and output connections, and consult the land-pattern drawing for exposed-pad and thermal requirements. The compact 5 mm by 5 mm LFCSP package has no matching package-diagram key in the current library, so a generic outline is displayed.
What reference clock inputs does the AD9553BCPZ accept?
The AD9553BCPZ accepts up to two single-ended reference inputs on REFA and REFB, or one differential reference input. According to the Analog Devices manufacturer product page, the flexible reference arrangement lets a design use either two separate sources or a differential clock source. The unused reference path must be handled according to the manufacturer’s termination guidance to avoid an undefined input condition.
Is the AD9553BCPZ suitable for GPON and base-station equipment?
The AD9553BCPZ is specifically designed for passive optical network and base-station clock-translation requirements. Its integer-N PLL can derive a service or transport clock from an external reference, while the 810 MHz maximum operating frequency supports high-speed communications timing systems. Actual deployment suitability still depends on the required output range, jitter, reference quality, and board-level signal integrity.
How does the AD9553BCPZ compare with an AD9553 evaluation board?
The AD9553BCPZ is the clock-translator IC, whereas AD9553/PCBZ is a clock-buffer/driver/receiver/translator timing evaluation board. The evaluation board is useful for evaluating the AD9553 family but is not a pin-to-pin replacement for the 32-LFCSP-WQ integrated circuit. A PCB redesign or different footprint would be required to substitute the board for the AD9553BCPZ.
What is the best drop-in replacement for the AD9553BCPZ?
No confirmed drop-in replacement for the AD9553BCPZ is established by the available manufacturer and cross-reference information. A valid substitute must use the same 32-LFCSP-WQ footprint, preserve pin-to-pin compatibility, and maintain the required reference-input, output-frequency, PLL, and jitter performance. A clock IC with similar frequency or PLL terminology is not automatically a drop-in replacement and should not be substituted without a manufacturer pin-compatibility statement.
Can another clock translator replace the AD9553BCPZ?
Another clock translator can replace the AD9553BCPZ only after its pinout, package, reference-input architecture, divider programming, PLL behavior, and output requirements are verified against the original design. The AD9553BCPZ uses an integer-N PLL and supports one output, so a candidate with a different feedback divider, reference arrangement, or package may require software and PCB changes rather than a direct substitution.
When should I choose the AD9553BCPZ for clock translation?
Choose the AD9553BCPZ when a communications system needs a PLL-based frequency translator with one output, operation to 810 MHz, and either two single-ended references or one differential reference. It is particularly relevant to GPON, base-station, Ethernet, SONET/SDH, and T1/E1 designs. Choose a different device only when its output architecture, package, or programming interface better matches the complete timing requirement.
Is the AD9553BCPZ the same as the AD9553ACPZ?
The AD9553BCPZ and AD9553ACPZ are not automatically interchangeable even though both names refer to the AD9553 family. Package suffix differences can indicate different package, temperature, grade, or ordering options, and the manufacturer data must establish that their pinouts and electrical ratings are identical. Without that confirmation, treat them as distinct orderable devices rather than a verified drop-in replacement.
Where can I buy the AD9553BCPZ and check its price?
Use the Request a Quote form on this page to request the AD9553BCPZ, current commercial terms, stock status, and lead time. The form is the appropriate channel for a quote because clock-translator availability and volume pricing can change with configuration and order quantity. No fixed price or stock claim should be inferred solely from a catalog or search listing.
What is the lead time for the AD9553BCPZ?
The current lead time for the AD9553BCPZ should be confirmed through the Request a Quote form on this page. Lead time can vary with order quantity, package configuration, and supply conditions, and the manufacturer product page does not define a universal purchasing lead time. Request the quantity, target date, and required shipment destination with the quote request.
Is the AD9553BCPZ in stock?
Current AD9553BCPZ stock status should be confirmed through the Request a Quote form on this page. Search and catalog pages may not reflect synchronized inventory, and a distributor landing page alone does not establish availability for a specific quantity. The quote request can capture the required quantity, package configuration, delivery date, and shipment destination.
What are the key specifications of the AD9553BCPZ that engineers should know?
The key AD9553BCPZ specifications are an 810 MHz maximum operating frequency, one clock output, an integer-N PLL, and support for up to two single-ended or one differential reference input. The device is packaged in a 32-LFCSP-WQ measuring 5 mm by 5 mm. According to the Analog Devices manufacturer product page, its target applications include GPON, base stations, Ethernet, SONET/SDH, and T1/E1 systems.

Data referensi kejuruteraan untuk AD9553BCPZ — perbandingan, panduan rancangan, dan maklumat kesediaan

Panduan Pilihan

Choose the AD9553BCPZ when a communications design requires an integer-N PLL to translate an existing reference into a clock with one output and operation as high as 810 MHz. It is a strong fit for GPON, cellular base-station, carrier Ethernet, SONET/SDH, and T1/E1 timing architectures that can use either two single-ended references or one differential reference. The compact 32-LFCSP-WQ package also supports dense equipment designs. Select a different clock translator when it offers a verified pin-to-pin-compatible interface, the required divider or PLL behavior, better jitter performance, or a packaging option that matches the existing PCB. Do not treat the AD9553/PCBZ evaluation board as a substitute, and do not rely on similar PLL specifications alone; confirm pin compatibility, reference configuration, programming, output frequency, jitter, and lifecycle requirements before replacing an established design.

Perbandingan dengan Gantian

Parametr Produk Ini
Brand Analog Devices
Package 32-LFCSP-WQ, 5 mm x 5 mm
Maximum Operating Frequency 810 MHz
Output Count 1 output
PLL Architecture Integer-N PLL
Reference Input Configuration Up to 2 single-ended inputs or 1 differential input
Reference Input Names REFA and REFB
Target Applications GPON, base stations, Ethernet, SONET/SDH, and T1/E1

Penyeberangsung Jelas

  • Communications-specific integer-N clock translation (vsAD9553/PCBZ)
  • Flexible reference architecture (vsAD9553/PCBZ)
  • Application-targeted clock generation (vsGeneric clock buffers)

Catatan Desain

Route REFA, REFB, and the clock output over continuous reference planes and keep the loops formed by each clock trace and its return path as small as practical. The 810 MHz capability makes trace length, impedance continuity, connector transitions, and nearby switching-noise sources significant. Match the routing method to the PCB stack-up and use the manufacturer’s interface guidance for single-ended versus differential operation.

Do not leave an unused reference input without a defined termination condition. Analog Devices guidance for the AD9553 family describes AC-coupling the unused Reference B pin to ground with a 0.1 µF capacitor in the discussed single-ended Reference A configuration. Apply that technique only when it matches the actual clock arrangement, and confirm the final network against the manufacturer’s reference-input requirements before production.

Keep the PLL’s supply and ground connections clean because reference and output-jitter performance can be affected by supply noise and impedance paths around the package. Follow the manufacturer’s recommended decoupling arrangement and provide the lowest-inductance connection to ground available on the board. Avoid placing noisy switching regulators or high-current return paths immediately beneath sensitive clock nets unless the stack-up and return-current path have been evaluated.

Evaluate the complete reference path rather than only the nominal clock frequency. Source amplitude, edge rate, duty-cycle distortion, reference jitter, coupling, and termination all influence PLL behavior. Because the AD9553 uses an integer-N architecture, the translated output must be checked against the receiving circuit’s frequency and phase requirements, including any division ratio and loop bandwidth selected during configuration.

Maklumat Kesediaan

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Bosong logam timbal
Unknown
Bosong halogen
Unknown
Mineral konflik
Unknown

The available manufacturer page identifies the device and its communications applications but does not provide extractable RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations.

Data disahkan pada: 2026-11-19 — data yang disahkan dan disusun semula oleh pasukan kejuruteraan komponen XAIPART

Pencarian Berhubungan

AD9553BCPZ datasheet AD9553BCPZ datasheet pdf AD9553BCPZ pinout AD9553BCPZ 32-LFCSP AD9553BCPZ 810MHz AD9553BCPZ integer-N PLL Analog Devices AD9553BCPZ AD9553BCPZ GPON clock translator AD9553BCPZ base station timing AD9553BCPZ replacement AD9553BCPZ equivalent AD9553BCPZ price AD9553BCPZ stock AD9553BCPZ schematic AD9553 reference input termination

Komponen dan Tanda berkaitan

Analog Devices AD9553BCPZ AD9553 AD9553/PCBZ integer-N PLL phase-locked loop clock translator clock and timing IC semiconductor 810 MHz REFA REFB differential clock input single-ended clock input 32-LFCSP-WQ LFCSP package family surface-mount package GPON base-station timing Ethernet SONET/SDH T1/E1 output jitter reference termination
RFRC Saring Pantas
Isikan butiran lengkap — pasukan jualan kami akan bertindak balas dalam masa 24 jam
Nombor Bahagian Pengeluar Pakej QTY Harga Target Lengkap
✓
Pesan diskon sudah disubmit!

Kami akan bertindak balas kepada emel anda dalam tempoh 24 jam

1
RFQ Diserahkan
2
kutipan Diterima
3
Order Dipesan
4
Pembayaran
5
Dihantar
6
Diantar
Lihat Perincian RFQ