ADM3074EYRZ - 3.3V 500kbps RS-485 Transceiver | Analog Devices
MPN: ADM3074EYRZ ✓ AktifADM3074EYRZ Ringkasan
An RS-485 transceiver is an interface IC that translates logic-level signals between a host controller and a differential bus. The differential driver strengthens signal levels and rejects much of the common-mode noise encountered in industrial cabling. The ADM3074EYRZ complies with TIA/EIA RS-485 and RS-422 requirements, making it suitable for equipment distributed across longer cable runs, factory networks, and industrial control systems where electrical noise and electrostatic discharge are important design concerns.
Key features include ±15 kV ESD protection, reduced slew rates for low electromagnetic interference, hot-swap input structures on the data-enable and receiver-enable pins, and high-impedance outputs when the transceiver is disabled or powered off. The common-mode input range extends from -7 V to +12 V, while the available temperature options extend from -40°C to +125°C. These characteristics support robust interface designs in industrial, building-automation, instrumentation, and communications equipment.
The full-duplex configuration provides separate transmit and receive paths rather than sharing a single bus pair. That architecture is useful when a node must transmit and receive simultaneously or where separate differential pairs are practical. Reduced edge rates help lower radiated emissions, although system designers must still control trace impedance, cable return paths, grounding, and protection-network placement to minimize EMI.
Typical applications include industrial PLC and sensor networks, building-control equipment, instrumentation links, data-acquisition systems, and industrial communications ports. The 8-lead SOIC footprint supports compact board layouts, while the 3.3 V supply operation aligns with modern embedded processors and field-programmable controllers.
When laying out the interface, route the bus-side differential pair as a closely coupled pair and keep transceiver and protection components close to the connector. Confirm that the controller's logic levels, driver-enable polarity, bus-idle state, termination strategy, and common-mode operating range are compatible with the complete system. This page combines manufacturer specifications, package details, application guidance, and drop-in replacement analysis for faster engineering evaluation.
Pilihan pengganti yang segera untuk ADM3074EYRZ — sama paket, pin-pin kompatibel. Bahagian paket yang berbeza memerlukan kerja ulang PCB diasingkan.
Varietas dalam siri ini
Model serupa yang kompatibel dengan pengganti yang segera ADM3074EYRZ (sama faktor bentuk dan kaki) — berbeza dalam Package, Product Type, Supply Voltage, ESD Protection, Maximum Data Rate.
ADM3074EARZ
✅ Masuk Drop-In ⚠️ Spesifikasi Tidak DisahkanHubungi untuk harga
Lihat Datasheet →ADM3072EARZ
✅ Masuk Drop-InHubungi untuk harga
Lihat Datasheet →ADM3075EARZ
✅ Masuk Drop-In ⚠️ Spesifikasi Tidak DisahkanHubungi untuk harga
Lihat Datasheet →SN75176BPSR
✅ Masuk Drop-In ⚠️ Spesifikasi Tidak DisahkanHubungi untuk harga
Lihat Datasheet →SN65HVD71DR
✅ Masuk Drop-In ⚠️ Spesifikasi Tidak DisahkanHubungi untuk harga
Lihat Datasheet →SN65HVD52DR
✅ Masuk Drop-In ⚠️ Spesifikasi Tidak DisahkanHubungi untuk harga
Lihat Datasheet →ADM3074EYRZ Spesifikasi
| Product Type | RS-422/RS-485 full-duplex data transceiver |
| Tegangan Pemberi Arus | 3.3 V |
| Maximum Data Rate | 500 kbps |
| ESD Protection | ±15 kV |
| Duplex Mode | Full duplex |
| Communication Standard | TIA/EIA RS-485 and RS-422 |
| Common-Mode Input Range | -7 V to +12 V |
| Operating Temperature Option | -40°C to +125°C |
| Kemasan | 8-lead narrow SOIC |
| Jenis Pemasangan | Surface mount |
| Hot-Swap Inputs | Available on DE and RE pins |
| Slew Rate | Reduced for low EMI |
| Disabled Output State | High impedance |
| Power-Off Output State | High impedance |
| Protection | Thermal shutdown and short-circuit protection |
| Bus Topology | Multipoint bus transmission lines |
| Power Classification | Low-power 3.3 V transceiver |
Panduan Konfigurasi Pin ADM3074EYRZ 8-lead narrow soic
Konfigurasi pin untuk ADM3074EYRZ (8-lead narrow soic pakai). Penomeran pin, fungsi, dan garis bentuk koneksi ditakrifkan dalam dokumen pengeluar. Rujuk dokumen untuk kebentuk dan pedoman pengasman.
Tiada data garisan pin yang diperoleh untuk ADM3074EYRZ.
Rujuk kepada lembaran data untuk konfigurasi pin penuh.
Aplikasi Biasa
ADM3074EYRZ patut untuk 6 aplikasis: Industrial Sensor Networks, Building Automation Controllers, Data Acquisition Equipment, Programmable Logic Controller Interfaces, Instrumentation Communication Ports, Telecom and Remote Monitoring.
Industrial Sensor Networks
The ADM3074EYRZ fits industrial sensor networks that require a 3.3 V RS-485 interface and a data rate above the common 115.2 kbps operating point. Its 500 kbps capability provides additional bandwidth for nodes exchanging measurements, commands, and diagnostic data. The ±15 kV ESD protection improves robustness when field wiring is connected near machinery or personnel. Reduced slew rates also help limit high-frequency emissions, although engineers must still control cable routing and grounding. Separate full-duplex paths support simultaneous communication where the system architecture can accommodate them.
Disebarkan
Building Automation Controllers
The ADM3074EYRZ is suitable for building-automation controllers that connect HVAC, access, lighting, and environmental modules over a balanced RS-485 network. Its 3.3 V supply can simplify integration with low-voltage controllers, while the 500 kbps rate supports more responsive network traffic than a conventional 115.2 kbps link. The -7 V to +12 V common-mode input range provides additional tolerance for ground-potential differences between remotely installed equipment. Reduced slew rates help control radiated EMI in occupied buildings, but proper cable selection and isolated grounding remain essential.
Disebarkan
Data Acquisition Equipment
The ADM3074EYRZ can serve as the communication interface in data-acquisition equipment that transfers sampled measurements to a controller or host. The 500 kbps maximum rate supports denser data streams than a basic 115.2 kbps RS-485 implementation, while the full-duplex architecture allows independent transmit and receive activity. Its 8-lead narrow SOIC package supports compact analog and digital boards. Use controlled differential routing, proper bus termination, and a defined idle state to preserve data integrity when many acquisition modules share the same bus.
Disebarkan
Programmable Logic Controller Interfaces
The ADM3074EYRZ is well suited to PLC and embedded-control interfaces requiring a compact 3.3 V RS-485 port. Its 500 kbps data rate provides a practical balance between bus throughput, cable length, and transceiver simplicity, and the narrow 8-lead SOIC package fits densely populated controller boards. Hot-swap inputs on the driver-enable and receiver-enable pins improve startup behavior when remote equipment may already be active. Designers should account for the high-impedance disabled state, confirm enable polarity against the controller, and verify the complete bus termination network.
Disebarkan
Instrumentation Communication Ports
The ADM3074EYRZ can connect laboratory or process instrumentation to a supervisory controller over a balanced RS-422 or RS-485 link. At up to 500 kbps, the interface supports responsive command and measurement traffic while retaining compatibility with common multipoint industrial bus practices. The ±15 kV ESD rating is valuable when instruments are connected and disconnected by operators, and reduced slew rates support cleaner operation in sensitive environments. Keep the bus pair tightly coupled, use suitable grounding, and avoid placing long unprotected stubs on the bus.
Disebarkan
Telecom and Remote Monitoring
The ADM3074EYRZ is applicable to remote monitoring and telecom equipment that distributes low-voltage control or status information over a balanced bus. Its 3.3 V operation suits modern line-card and embedded platforms, while the full-duplex configuration can support simultaneous upstream reporting and downstream commands. The common-mode input range of -7 V to +12 V is useful in systems where ground offsets vary between equipment locations. The interface should still be paired with application-appropriate surge protection, chassis grounding, and cable shielding for electromagnetic-immunity requirements beyond ESD.
Disebarkan
Ringkasan Produk Disebarkan
Data referensi kejuruteraan untuk ADM3074EYRZ — perbandingan, panduan rancangan, dan maklumat kesediaan
Panduan Pilihan
Perbandingan dengan Gantian
| Parametr | Produk Ini | ADM3074EARZ | ADM3072EARZ | ADM3075EARZ | SN75176BPSR |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Package | 8-lead narrow SOIC | 8-lead narrow SOIC | 8-lead narrow SOIC | 8-lead narrow SOIC | SOIC-8 |
Penyeberangsung Jelas
- Full-duplex operation in an 8-lead SOIC (vsADM3072EARZ)
- 500 kbps operation for higher-throughput buses (vsSN75176BPSR)
- ±15 kV ESD protection with hot-swap enable inputs (vsSN65HVD71DR)
- Reduced slew rates for lower EMI (vsADM3075EARZ)
Catatan Desain
Route the driver-side and receiver-side differential pairs as tightly coupled traces with continuous ground reference. Keep the transceiver close to the board connector and place any protection network between the connector and bus pins. Avoid changing layer references along one leg of a differential pair, and keep unused transceiver inputs, enables, and supply pins connected according to the manufacturer pin-description table.
Do not assume that matching an 8-lead SOIC footprint guarantees electrical interchangeability. Check driver-enable and receiver-enable polarity, bus-idle behavior, differential pin assignments, common-mode limits, supply voltage, and maximum data rate before approving a substitute. The ADM3072EARZ is especially important to review because its comparison identifies half-duplex operation, while the ADM3074EYRZ is full duplex.
The reduced slew rate of the ADM3074EYRZ helps lower radiated emissions, but the complete interface still requires disciplined cable and board layout. Use a twisted-pair bus, continuous grounds, controlled connector return paths, and the termination strategy required by the number and location of connected nodes. Avoid long unprotected branches because they can act as antennas and alter reflections at the receiver.
Place the 3.3 V supply decoupling capacitor close to the transceiver supply and ground pins, and provide uninterrupted ground-plane return paths beneath the device. Keep switching regulators and high-current digital returns away from the bus-side traces. This arrangement reduces conducted and radiated disturbance at the interface while preserving the low-noise benefit of the transceiver's reduced slew rate.
Plan hot-plug and bus-idle behavior before connecting the board. The DE and RE pins use hot-swap input structures, and outputs become high impedance when disabled or powered off, but system firmware must still prevent conflicting drivers from taking control of the same bus. Confirm fail-safe behavior for open, shorted, and idle conditions so a disconnected peripheral cannot corrupt commands on the network.
Maklumat Kesediaan
No specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations were present in the retrieved product data. The interface IC is not an automotive-qualified device based on the available ordering information.