Texas Instruments

INA110KUG4 - 2.5 MHz Military Instrumentation Amplifier | Texas Instruments

MPN: INA110KUG4 ✓ Aktif
±15 V Vdss 16-SOIC Package
MOQ: 1 |

INA110KUG4 Ringkasan

The Texas Instruments INA110KUG4 is a single-circuit instrumentation amplifier packaged in a 16-pin SOIC. It is identified as a military-temperature-grade, gull-wing-lead device, and its listed gain-bandwidth product is 2.5 MHz. The INA110KUG4 is intended for systems that require a differential input stage, an adjustable-gain architecture, and a regulated output referenced to a low-impedance analog supply.

An instrumentation amplifier is a precision analog building block that amplifies the voltage difference between two input signals while rejecting common-mode interference. Unlike a general-purpose operational amplifier, an instrumentation amplifier normally incorporates a high-impedance differential input stage, accurate gain-setting resistors, and a low-impedance output stage. Within the power-management and signal-chain hierarchy, it sits upstream of analog-to-digital converters, filters, and analog-to-digital output stages.

The INA110KUG4 is classified by Texas Instruments as an instrumentation amplifier rather than a standalone operational amplifier. Its adjustable external gain resistor allows the same circuit topology to support multiple sensitivity ranges, provided that resistor values remain suitable for the required bandwidth and stability. The 2.5 MHz gain-bandwidth figure makes the device relevant to moderate-bandwidth sensor conditioning rather than only static measurement systems.

Because the INA110KUG4 uses a precision differential input stage, it is suitable for conditioning low-level sensor outputs where common-mode voltage varies relative to the measurement. Typical signal sources include pressure bridges, strain gauges, thermocouples when paired with suitable cold-junction compensation, and high-impedance sensing elements. A reference pin also permits the output voltage to be shifted when the receiving circuit cannot tolerate a ground-centered signal.

Common applications include industrial process monitoring, laboratory instrumentation, data acquisition, medical monitoring equipment, and portable measurement systems. In a typical bridge-sensor circuit, the INA110KUG4 amplifies the small differential bridge voltage while rejecting much of the common excitation voltage. The output can then feed an analog-to-digital converter or an analog filter.

When laying out a board for the INA110KUG4, keep the gain-setting resistor close to its corresponding device pin and use a quiet analog ground for the reference and supply-return connections. Place input and reference decoupling capacitors near the package, and route sensitive input traces away from digital clocks, switching-regulator nodes, and high-current return paths.

This page combines the manufacturer part identity, package information, commercial listings, and comparison data for the INA110KUG4 with application guidance, layout cautions, and practical sourcing information. Review the complete manufacturer datasheet for the definitive pin configuration, electrical limits, gain equation, and recommended operating conditions before releasing a production design.

Pilihan pengganti yang segera untuk INA110KUG4 — sama paket, pin-pin kompatibel. Bahagian paket yang berbeza memerlukan kerja ulang PCB diasingkan.

Varietas dalam siri ini

Model serupa yang kompatibel dengan pengganti yang segera INA110KUG4 (sama faktor bentuk dan kaki) — berbeza dalam Package, Product Type, RoHS Status.

Texas Instruments
Package: 16-pin SOIC (SOL-16)
Product Type: Monolithic FET-input instrumentation amplifier
RoHS Status: unknown
Bandingkan Dengan INA110KUG4 →

INA110KU

✅ Masuk Drop-In
Texas Instruments
📦 16-SOIC
Monolithic FET-input instrumentation amplifier · 1 circuit · 1, 10, 100, 200, and 500 V/V · 2.5 MHz · 4 us to 0.01% · 17 V/us · 1 mV · 12 V to 36 V

Hubungi untuk harga

Lihat Datasheet →

INA110KUG4 Penilaian maksimum & Ciri-ciri Elektrik

Product Type Instrumentation Amplifier
Number of Circuits 1 circuit
Gain-Bandwidth Product 2.5 MHz
Kemasan 16-SOIC
Lead Form Gull wing
Package Body Width 7.50 mm
Temperature Grade Military
Typical Dual Supply Voltage ±15 V
Jenis Pemasangan Surface mount
Status RoHS RoHS

Panduan Konfigurasi Pin INA110KUG4 7.50 mm

Konfigurasi pin untuk INA110KUG4 (7.50 mm pakai). Komponen analog ini mempunyai pin masukan, keluaran, dan kuasa. Rujuk dokumen pengeluar untuk konfigurasi pengecualian, pemulihan, dan pin aktifkan. Ideal untuk pengawasan isyarat dan litar pengukur.

Garis bentuk pengecah pakai 7.50 mm untuk INA110KUG4

Tiada data garisan pin yang diperoleh untuk INA110KUG4.

Rujuk kepada lembaran data untuk konfigurasi pin penuh.

Aplikasi Biasa

INA110KUG4 patut untuk 6 aplikasis: Bridge and Strain-Gauge Sensor Conditioning, Laboratory Data-Acquisition Front End, Industrial Process Monitoring, Medical and Physiological Monitoring, Portable Battery-Powered Instrumentation, Precision Current and Voltage Monitoring.

🏭

Bridge and Strain-Gauge Sensor Conditioning

The INA110KUG4 fits bridge-based measurements because an instrumentation amplifier responds to the differential bridge voltage while rejecting the common excitation voltage present on both sensor nodes. The 2.5 MHz gain-bandwidth product supports moderate-bandwidth conditioning rather than only static temperature readings. Place the device close to the bridge, route the two input pairs as closely matched geometry as practical, and use the manufacturer gain equation to select the external gain resistor. Verify the maximum sensor excursion against both input overload and output-swing limits.

🖥️

Laboratory Data-Acquisition Front End

The INA110KUG4 can condition low-level laboratory inputs before conversion by a higher-resolution ADC. Its instrumentation-amplifier topology provides differential input handling and common-mode rejection, while the 16-SOIC package simplifies conventional surface-mount assembly. Use a clean reference voltage and place the external gain resistor close to the device to minimize pickup. Select the closed-loop gain so that the largest expected input, including transients and calibration tolerance, keeps the output within the usable swing.

⚡

Industrial Process Monitoring

The INA110KUG4 is applicable to industrial monitoring circuits that measure a small differential signal superimposed on a larger common-mode voltage. The 2.5 MHz listed gain-bandwidth product leaves room for signal conditioning beyond extremely slow process variables. Keep sensitive traces away from motor drive and switching-power stages, use a single-point analog return strategy, and check the military-grade ordering option against the installation's environmental requirements. Filtering belongs ahead of the amplifier when out-of-band interference could cause input overload.

💊

Medical and Physiological Monitoring

The INA110KUG4 can amplify differential physiological or sensor signals in a monitoring system, provided its noise, offset, common-mode range, and environmental characteristics satisfy the complete design specification. The military-temperature-grade ordering code is useful when the equipment faces a broad ambient range. A typical signal path places the sensor close to the amplifier, followed by protection, filtering, and digitization. Apply the medical product's required safety, isolation, leakage, and EMC controls rather than relying on amplifier selection alone.

📱

Portable Battery-Powered Instrumentation

The INA110KUG4 can serve as the low-level analog front end in portable measurement equipment where sensor output is small and supply headroom is limited. Because it is an instrumentation amplifier rather than a switching converter, the signal path adds no switching ripple to the measurement. Verify the exact supply-current demand and operating-voltage limits in the manufacturer datasheet, then use low-noise bypass capacitors and a low-noise reference. The 16-SOIC footprint supports compact layouts, although analog ground separation remains important.

🔧

Precision Current and Voltage Monitoring

The INA110KUG4 is useful when a monitor must distinguish a small differential measurement from a larger common-mode voltage. The differential input arrangement can measure the voltage across a shunt, the drop across a precision sense element, or another small series voltage. Set gain with the external resistor while keeping the input transient within the device's allowed range. Provide Kelvin-style routing where possible so that supply-drop and copper resistance do not add directly to the measured difference.

What is the INA110KUG4 and what package does it use?
The INA110KUG4 is a single-circuit instrumentation amplifier from Texas Instruments in a 16-pin SOIC package. It is built for precision differential signal conditioning with an adjustable external gain resistor. Distributor product records identify the device as a military-temperature-grade part with gull-wing leads. The 16-SOIC package has a listed body width of 7.50 mm and is intended for surface-mount PCB assembly.
What are the key specifications of INA110KUG4 that engineers should know?
The principal published specifications for the INA110KUG4 are one instrumentation-amplifier circuit, a 2.5 MHz gain-bandwidth product, and a 16-SOIC package. Texas Instruments classifies the KUG4 version as a military-temperature-grade device. The part also supports a dual-supply operating arrangement centered on ±15 V, with ±6 V and ±18 V identified in comparative product data as the minimum and maximum boundaries used in that description.
Where can I download the INA110KUG4 datasheet PDF?
The manufacturer datasheet is available through the official Texas Instruments INA110 document link listed on this page. Use the manufacturer PDF for the authoritative pin-description table, recommended application circuit, gain-setting equation, electrical characteristics, and supply-current limits. The manufacturer document should be used instead of relying only on distributor summaries when assigning PCB tracks or calculating a complete bill of materials.
Where can I find the INA110KUG4 pinout?
The INA110KUG4 pinout is found in the pin-description table of the Texas Instruments INA110 manufacturer datasheet. The device has 16 pins in a SOIC package, including connections for the differential inputs, gain-setting network, reference input, supply rails, and output. Use that table to identify exposed or no-connect positions and to preserve the exact numbering of the 16-pin gull-wing footprint.
What can replace the INA110KUG4 on the same PCB?
The INA110KU is the closest published same-family candidate because it also uses a 16-SOIC package. Its ordering code indicates a different temperature-grade option, so the replacement should be checked against the required environmental range and operating limits. Other instrumentation amplifiers can perform the same general function, but a functional match alone does not guarantee identical pinout, gain-setting network, reference behavior, or supply compatibility.
Is INA110KUG4 the same as INA110KU?
The INA110KUG4 and INA110KU are closely related Texas Instruments orderable variants in the 16-SOIC package. Their key documented difference is the device grade encoded by the ordering code: the G4 version is described as military temperature grade. Confirm the minimum and maximum operating temperatures, qualification status, and any marking or procurement requirements before treating one as a substitute for the other.
When should I choose the INA110KUG4 instead of the INA110KU?
Choose the INA110KUG4 when the design requires the military-temperature-grade ordering option and the environmental qualification associated with that variant. The INA110KU may be appropriate for commercial or industrial temperature requirements where those tighter grade expectations are unnecessary. Both devices use the same 16-SOIC package family, but the final choice must be based on temperature range, qualification documentation, availability, and the exact manufacturer operating limits.
Is the INA110KUG4 suitable for bridge-sensor measurement systems?
The INA110KUG4 is suitable for bridge-sensor signal conditioning because an instrumentation amplifier amplifies a small differential input while rejecting common-mode voltage. In a bridge circuit, the device can amplify the millivolt-level difference between bridge nodes and drive a following filter or analog-to-digital converter. The final gain must be selected so that the maximum expected input does not overload the internal amplifier or drive the output beyond its rated swing.
How much gain bandwidth does the INA110KUG4 provide?
The INA110KUG4 has a listed gain-bandwidth product of 2.5 MHz. Practical signal bandwidth is not equal to that number for every gain setting because the allowable gain, slew rate, output swing, and stability conditions determine the usable bandwidth. Confirm the selected gain against the gain-bandwidth relationship and then verify that the resulting closed-loop bandwidth covers the sensor and sampling requirements.
What design layout practices are important for the INA110KUG4?
Route the sensitive input and gain-setting connections away from switching nodes and high-current return paths. Place the external gain resistor close to the corresponding device pin to minimize parasitic resistance and interference pickup. Connect input, supply, and reference bypass capacitors near the package, and route analog returns so that output current does not share the input-reference path.
Does the INA110KUG4 require a single supply or dual supply?
The INA110KUG4 is commonly used with dual supplies, and comparative product information identifies a typical dual-supply condition of ±15 V. The same comparison cites ±6 V to ±18 V as its supply boundaries in that description. Because the definitive operating limits belong in the manufacturer datasheet, verify minimum and maximum supply voltage, common-mode range, and output swing before fixing the system power rails.
How do I reduce offset and noise in an INA110KUG4 circuit?
Start with the manufacturer-recommended input, reference, and supply-bypass capacitor values, then keep the sensitive nodes physically short and protected from electrostatic discharge. Use a low-noise reference voltage at the reference pin and avoid creating a ground-potential difference between the sensor and amplifier ground. Offset correction, filtering, and averaging can be added downstream when the measurement requires calibration rather than purely analog gain.
Can the INA110KUG4 be used for medical monitoring equipment?
The INA110KUG4 can be used as the analog front end in a medical monitoring signal chain when its electrical limits, noise performance, and environmental grade satisfy the system requirements. A typical use is amplifying a low-level differential sensor signal before filtering and digitization. Medical designs must additionally address applicable safety, isolation, leakage, EMC, and qualification requirements that are determined by the complete product rather than by the amplifier alone.
What is the relationship between the INA110KUG4 and INA117KU?
The INA117KU is an instrumentation-amplifier alternative from a different manufacturer that can be evaluated against the INA110KUG4 for gain, bandwidth, noise, supply range, and package. However, the published comparison does not by itself confirm a pin-for-pin match. Confirm the exact lead assignments, gain-setting method, reference-pin behavior, and output topology in each manufacturer datasheet before treating the INA117KU as a drop-in replacement.
Where can I buy INA110KUG4 online and what is its current lead time?
Use the Request a Quote form on this page to request current INA110KUG4 pricing, stock confirmation, and lead time for the exact Texas Instruments ordering code. Commercial listings in the United States and China identify the part in 16-SOIC packaging, but listing-level price or stock information can change independently of the manufacturer. A formal quote also confirms whether the required grade and quantity are available for your production schedule.
How should the INA110KUG4 gain resistor be selected?
Select the gain-setting resistor from the gain equation and bandwidth guidance in the Texas Instruments INA110 datasheet. A smaller resistance generally supports a higher closed-loop gain and broader usable bandwidth, while a larger resistance increases gain and reduces bandwidth. Also check resistor tolerance, temperature coefficient, parasitic capacitance, and the resulting output-voltage swing against the expected sensor signal.

Data referensi kejuruteraan untuk INA110KUG4 — perbandingan, panduan rancangan, dan maklumat kesediaan

Panduan Pilihan

Choose the INA110KUG4 when the design calls for a Texas Instruments INA110-family instrumentation amplifier in a 16-SOIC package and requires the military-temperature-grade ordering option. The INA110KU is the closest listed same-package alternative when a commercial temperature-grade option is acceptable, but environmental and qualification requirements must be checked before substitution. The INA117KU can be evaluated as a functional instrumentation-amplifier alternative, although its exact lead assignments, gain-setting method, supply range, and output behavior must be verified rather than assumed to match. For any replacement, compare the maximum differential input, common-mode range, output swing, reference behavior, gain equation, noise, and usable bandwidth. The INA110KUG4 is the stronger choice when a known manufacturer family, military-grade designation, and documented 2.5 MHz gain-bandwidth product are the primary requirements.

Perbandingan dengan Gantian

Parametr Produk Ini INA110KU
Brand Texas Instruments Texas Instruments
Package 16-SOIC 16-SOIC
Device Type Instrumentation Amplifier Instrumentation Amplifier
Number of Circuits 1 circuit 1 circuit

Penyeberangsung Jelas

  • Military-grade ordering option (vsINA110KU)
  • Matched package family (vsINA110KU)
  • Published signal-path bandwidth (vsINA110KU)

Catatan Desain

Keep the two differential input paths short, closely matched, and isolated from clocks, switching-regulator outputs, and relay contacts. Place the external gain-setting resistor close to its designated device pin to minimize parasitic resistance and noise pickup. A grounded guard or shielding strategy can help on boards with high-level analog inputs, but the complete return-current path must remain continuous so that sensor current does not flow through the input-reference node.

Do not select gain solely from the wanted output voltage. Confirm that the maximum differential input, expected sensor overrange, output swing, and closed-loop bandwidth all remain within the manufacturer operating limits. The 2.5 MHz gain-bandwidth figure is a device-level specification, not a promise that every gain setting provides 2.5 MHz of signal bandwidth. Recalculate the usable bandwidth and stability margin for the final external resistor and load.

Decouple the supply pins directly at the package and return the bypass-current path to the device ground without sharing a long path with digital output currents. Use a low-noise reference at the reference connection and avoid allowing reference ripple to modulate the output. Validate common-mode headroom during startup and supply ramp because an instrumentation amplifier can encounter input voltages outside its useful linear range even when the differential signal is small.

Maklumat Kesediaan

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
Bosong logam timbal
Unknown
Bosong halogen
Unknown
Mineral konflik
Unknown

RoHS is explicitly identified in the LCSC product listing. Other compliance fields are not established by the available product records and remain unknown.

Data disahkan pada: 2026-11-14 — data yang disahkan dan disusun semula oleh pasukan kejuruteraan komponen XAIPART

Pencarian Berhubungan

INA110KUG4 datasheet INA110KUG4 datasheet pdf INA110KUG4 pinout INA110KUG4 specifications INA110KUG4 price INA110KUG4 stock INA110KUG4 equivalent INA110KUG4 replacement INA110KUG4 vs INA110KU Texas Instruments INA110KUG4 INA110KUG4 16-SOIC footprint INA110KUG4 instrumentation amplifier application

Komponen dan Tanda berkaitan

Texas Instruments INA110KUG4 INA110KU INA117KU instrumentation amplifier differential amplifier analog signal chain sensor conditioning bridge sensor strain gauge common-mode rejection common-mode voltage gain-bandwidth product external gain resistor reference input ADC 16-SOIC SOIC package family surface mount military temperature grade RoHS low-pass filter Kelvin connection analog ground
RFRC Saring Pantas
Isikan butiran lengkap — pasukan jualan kami akan bertindak balas dalam masa 24 jam
Nombor Bahagian Pengeluar Pakej QTY Harga Target Lengkap
✓
Pesan diskon sudah disubmit!

Kami akan bertindak balas kepada emel anda dalam tempoh 24 jam

1
RFQ Diserahkan
2
kutipan Diterima
3
Order Dipesan
4
Pembayaran
5
Dihantar
6
Diantar
Lihat Perincian RFQ