Texas Instruments

INA121UAG4 - Low-Power FET Instrumentation Amplifier | Texas Instruments

MPN: INA121UAG4 ✗ Akhir Hayat
MOQ: 1 |

INA121UAG4 Ringkasan

The Texas Instruments INA121UAG4 is a FET-input, low-power instrumentation amplifier designed for precision differential-signal measurement. The device provides a 1 V/V to 1000 V/V programmable gain range, operates from a 4 V to 36 V supply, and is packaged in an 8-pin SOIC. Its low input bias current, high input impedance, and common-mode rejection support accurate measurement of weak sensor signals in industrial and scientific equipment.

An instrumentation amplifier is a differential amplifier optimized for amplifying a small voltage difference between two inputs while rejecting common-mode voltage. The INA121 belongs to the broader hierarchy of differential amplifiers, analog signal-chain ICs, and amplifiers used within electronic instrumentation. Its three-op-amp architecture provides precision differential amplification in a compact surface-mount package without requiring separate precision resistor networks.

The INA121's principal benefits include programmable gain from 1 V/V to 1000 V/V, low quiescent current, low input offset voltage, and high common-mode rejection ratio. The internal gain-setting resistor allows the gain to be selected with one external resistor while preserving the small package size. These characteristics are useful when the measured differential voltage is much smaller than the voltage common to both input terminals.

The INA121 uses a three-op-amp signal architecture with FET-input stages to provide high input impedance. The differential input is amplified according to the selected external gain resistor, while internal feedback networks reject common-mode voltage and improve gain accuracy. Input protection and feedback arrangements should be checked against the operating input range before connecting sensors whose outputs may exceed the electrical limits.

Typical uses include bridge-transducer measurement, current sensing, biomedical instrumentation, portable measurement equipment, and industrial sensor interfaces. The device can also amplify differential voltages in test and measurement systems when its input, output, supply, and common-mode limits are respected. Its surface-mount package supports compact analog front ends but requires careful grounding and stable reference arrangements.

For best results, place the gain-setting resistor close to the gain pin, connect the reference connection to a low-impedance ground for unipolar output or to a precision midpoint for bipolar output, and provide adequate supply bypassing. Output-voltage headroom, common-mode range, input bias-current effects, and resistor tolerance must all be considered when defining the usable measurement range.

This page combines the manufacturer product information, lifecycle and package details, sourced cross-reference candidates, application guidance, and practical design considerations. It also distinguishes confirmed package and lifecycle facts from electrical parameters that require direct confirmation against the current Texas Instruments datasheet before a new design is released.

Pilihan pengganti yang segera untuk INA121UAG4 — sama paket, pin-pin kompatibel. Bahagian paket yang berbeza memerlukan kerja ulang PCB diasingkan.

Varietas dalam siri ini

Model serupa yang kompatibel dengan pengganti yang segera INA121UAG4 (sama faktor bentuk dan kaki) — berbeza dalam Architecture, Package, Quiescent Current, Gain Configuration, Gain Range.

Texas Instruments
Architecture: Two-op-amp design
Package: 8-pin SOIC, 3.90 mm width
Quiescent Current: 175 µA per channel
Bandingkan Dengan INA121UAG4 →
Texas Instruments
Architecture: Two-op-amp instrumentation amplifier
Package: 8-pin SOIC
Quiescent Current: 175 µA per channel
Bandingkan Dengan INA121UAG4 →
Texas Instruments
Architecture: Three-op-amp instrumentation amplifier
Package: 8-pin SOIC
Gain Range: 1 to 10,000
Bandingkan Dengan INA121UAG4 →
Texas Instruments
Quiescent Current: 700 µA typical
Gain Range: 1 V/V to 10,000 V/V

INA126U

✅ Masuk Drop-In
Texas Instruments
📦 8-pin SOIC
Single-circuit micropower precision instrumentation amplifier · 36 V · ±1.35 V to ±18 V · 175 µA per channel · 250 µV · Two-op-amp design · 1 amplifier · Differential signal acquisition

Hubungi untuk harga

Lihat Datasheet →

INA126UA

✅ Masuk Drop-In
Texas Instruments
📦 8-pin SOIC
Single-channel precision instrumentation amplifier · 1 channel · 36 V · 2.7 V · ±1.35 V to ±18 V · 175 µA per channel · 250 µV maximum · 200 kHz

Hubungi untuk harga

Lihat Datasheet →

INA129U

✅ Masuk Drop-In
Texas Instruments
📦 8-pin SOIC
Precision, low-power instrumentation amplifier · Three-op-amp instrumentation amplifier · ±2.25 V to ±18 V · ±18 V · 1.3 MHz · 200 kHz · 50 µV · 0.5 µV/°C

Hubungi untuk harga

Lihat Datasheet →

INA121UAG4 Penilaian maksimum & Ciri-ciri Elektrik

Tiada spesifikasi tersedia

Panduan Konfigurasi Pin INA121UAG4 standard

Konfigurasi pin untuk INA121UAG4 (standard pakai). Komponen analog ini mempunyai pin masukan, keluaran, dan kuasa. Rujuk dokumen pengeluar untuk konfigurasi pengecualian, pemulihan, dan pin aktifkan. Ideal untuk pengawasan isyarat dan litar pengukur.

Garis bentuk pengecah pakai standard untuk INA121UAG4

Tiada data garisan pin yang diperoleh untuk INA121UAG4.

Rujuk kepada lembaran data untuk konfigurasi pin penuh.

Aplikasi Biasa

INA121UAG4 patut untuk 6 aplikasis: Bridge Transducer Amplification, Precision Current Sensing, Biomedical Sensor Signal Conditioning, Portable Instrumentation, Laboratory Data Acquisition, Industrial Sensor Interface.

🏭

Bridge Transducer Amplification

The INA121UAG4 suits Wheatstone bridge sensing because its FET-input instrumentation-amplifier architecture amplifies the small differential voltage generated by resistance changes while rejecting common-mode voltage. A programmed gain from 1 V/V to 1000 V/V allows the output range to be matched to a bridge excitation and ADC input. The external gain resistor should use a low-tolerance, low-temperature-coefficient network because its error directly becomes gain error. Verify bridge excitation voltage, input common-mode range, output swing, and reference configuration before operation.

⚡

Precision Current Sensing

INA121UAG4 can amplify the differential voltage produced by a current-sense shunt when the signal is small relative to the shunt's common-mode voltage. Its high-impedance FET inputs reduce disturbance of the shunt and support programmed gain up to 1000 V/V. Layout should use a short Kelvin-style connection from the shunt to the amplifier, separate input returns from power-return currents, and local supply bypass. Confirm the shunt voltage, common-mode limits, output swing, and amplifier settling behavior before selecting a gain.

💊

Biomedical Sensor Signal Conditioning

The INA121UAG4 is applicable to low-amplitude differential sensor signals in biomedical and diagnostic equipment when high input impedance and common-mode rejection are important. Its compact 8-pin SOIC footprint permits placement close to the sensor connector, while programmable gain adapts the signal to an ADC or controller input. For patient-connected designs, isolation, protection, leakage, creepage, and applicable medical-device requirements must be evaluated separately; the amplifier's specified operating range alone does not establish patient-safety compliance.

📱

Portable Instrumentation

INA121UAG4 fits portable measurement systems where power efficiency, compactness, and accurate differential amplification are required. The low-power instrumentation-amplifier configuration combines a small SOIC footprint with a gain range of 1 V/V to 1000 V/V, allowing one analog-front-end design to cover multiple sensor sensitivities. Battery-operated equipment should account for quiescent current, startup behavior, reference current, and the input bias current required by the chosen gain resistor when estimating battery life.

🖥️

Laboratory Data Acquisition

INA121UAG4 provides the analog front end for laboratory DAQ modules that must measure small differential voltages superimposed on larger common-mode levels. The FET-input stage and selectable gain support compatibility with sensors such as strain gauges, thermocouple interfaces, and bridge transducers. Keep the gain resistor and bypass capacitors close to the device, use a stable reference for bipolar signals, and provide analog and digital ground routing that avoids forcing return currents through the measurement node. Confirm settling and input-range requirements against the actual signal bandwidth.

🏭

Industrial Sensor Interface

INA121UAG4 can condition differential outputs from industrial sensors when the system operates within the amplifier's 4 V to 36 V supply range and -40 °C to +85 °C temperature range. Its three-op-amp architecture provides gain and common-mode rejection in a compact 8-pin SOIC, reducing the number of discrete precision elements required. Industrial equipment should add appropriate surge and transient protection, isolate long sensor wiring from sensitive inputs, and verify that normal signal excursions remain inside the electrical limits throughout the complete gain range.

What is the INA121UAG4?
The INA121UAG4 is a Texas Instruments FET-input, low-power instrumentation amplifier in an 8-pin SOIC package. According to the manufacturer product page, the INA121 family uses a three-op-amp architecture and is intended for precision differential-signal amplification. It operates from a 4 V to 36 V supply, supports programmed gains from 1 V/V to 1000 V/V, and is specified over -40 °C to +85 °C. The obsolete lifecycle status means new production should not be assumed without written manufacturer confirmation.
What is the operating voltage of INA121UAG4?
The INA121UAG4 operates from a 4 V minimum to 36 V maximum supply voltage. Texas Instruments describes the INA121 as a low-power instrumentation amplifier for precision signal conditioning, and the family page identifies both 8-pin plastic DIP and SO-8 surface-mount options. Designers should use the absolute maximum and recommended operating tables in the manufacturer datasheet when checking supply tolerance, startup behavior, input excursions, and output headroom.
Where can I download the INA121UAG4 datasheet PDF?
The official INA121 datasheet and ordering information are available from the Texas Instruments INA121 product page at https://www.ti.com/product/INA121. The INA121UAG4 ordering code identifies the 8-pin SOIC package, while the family datasheet contains the electrical characteristics, pin configuration, gain-setting relationship, application examples, and ordering information. Use the manufacturer document as the controlling source for design release, especially because this exact order code is listed as obsolete.
Where can I find the INA121UAG4 pinout?
The INA121UAG4 pin configuration is documented in the pin-configuration section of the Texas Instruments INA121 datasheet and its associated 8-pin SOIC package drawing. The device uses eight pins, but an exact numbered pin list is not reproduced here because the official result pages do not expose that table. Before routing a PCB, assign every pin directly from the manufacturer pin-description diagram rather than relying on a generic SOIC-8 drawing.
What are the key specifications of INA121UAG4 that engineers should know?
The INA121UAG4 is a one-circuit, FET-input instrumentation amplifier with programmable gain from 1 V/V to 1000 V/V, a 4 V to 36 V supply range, and an operating temperature range of -40 °C to +85 °C. It uses a three-op-amp architecture and is housed in an 8-pin SOIC. The manufacturer identifies it as low power, while detailed input offset, bias current, CMRR, quiescent-current, and common-mode limits must be taken from the family datasheet.
Can INA121UAG4 measure low-level differential signals?
Yes, the INA121UAG4 is designed for low-level differential-signal measurement because its FET inputs provide high input impedance and its instrumentation-amplifier architecture rejects common-mode voltage. Gain can be set from 1 V/V to 1000 V/V with an external resistor. Practical performance also depends on sensor source impedance, resistor tolerance, reference-node stability, input protection, and remaining output common-mode range across the selected gain.
INA121UAG4 vs INA126U - which is better for bridge sensors?
The INA121UAG4 and INA126U are both instrumentation amplifiers from Texas Instruments, but their gain ranges and input common-mode capabilities differ. The INA121 supports gains up to 1000 V/V, while the INA126 family extends the available gain to 10000 V/V. Choose based on bridge excitation, signal amplitude, input common-mode range, reference arrangement, and the complete datasheet constraints; the cross-reference result alone does not establish unconditional interchangeability.
What is the difference between INA121UAG4 and INA129U?
The INA129U offers a broader gain range than the INA121UAG4, reaching 10000 V/V compared with the INA121's 1000 V/V maximum. The INA129 family also targets high-impedance sensor networks and provides different input and output common-mode considerations. Both use an 8-pin SOIC option, but a shared package does not alone prove pin-to-pin drop-in compatibility. Confirm the gain resistor connection, supply limits, reference pin, and absolute maximum ratings before substitution.
When should I choose INA121UAG4 over INA126U or INA129U?
Choose the INA121UAG4 when a maximum gain of 1000 V/V is sufficient and the design specifically targets the INA121's electrical characteristics and gain-setting method. Consider the INA126U when higher gain is required, and the INA129U when its input-impedance and common-mode behavior better match the sensor. Because INA121UAG4 is obsolete, final selection should also include a written lifecycle and availability review rather than relying on nominal package similarity.
Is INA121UAG4 suitable for industrial sensor interfaces?
The INA121UAG4 can suit industrial sensor interfaces that operate within its 4 V to 36 V supply range and -40 °C to +85 °C temperature range. Its FET inputs and programmable differential gain are useful for bridge and transducer signals, while the compact 8-pin SOIC simplifies board integration. Industrial suitability is conditional on surge, noise, grounding, input common-mode range, and long-term availability requirements being reviewed for the actual installation.
What is the best drop-in replacement for INA121UAG4?
No unconditional best drop-in replacement can be established from the available cross-reference results alone. INA126U, INA126UA, and INA129U appear as related 8-pin instrumentation-amplifier candidates, but their gain ranges and input common-mode requirements differ from INA121UAG4. Treat them as engineering-review candidates rather than automatic replacements. Verify every pin function, the external gain-resistor connection, supply range, input and output headroom, reference behavior, temperature range, and lifecycle status before approving a substitution.
Can INA126U replace INA121UAG4?
The INA126U may be a functional alternative, but it should not be treated as a confirmed drop-in replacement without a pin and parameter audit. It supports a gain range up to 10000 V/V rather than the INA121's 1000 V/V maximum, and the higher gain option has different input and output common-mode constraints. The physical 8-pin package is helpful but does not eliminate the need to verify the gain resistor pin, reference connection, supply requirements, and operating ranges.
What is the best Texas Instruments equivalent for INA121UAG4?
INA126U is a Texas Instruments instrumentation-amplifier candidate for review when a gain range above 1000 V/V is acceptable, while INA129U is another same-family candidate with different high-impedance and common-mode characteristics. Neither should be installed solely because it uses an 8-pin SOIC. The appropriate equivalent depends on the required gain, bridge excitation, sensor impedance, input common-mode range, output swing, reference configuration, and qualified lifecycle needs.
Where can I buy INA121UAG4 and what is the lead time?
Use the Request a Quote form on this page to request INA121UAG4 availability, current lead time, minimum order quantity, and any authorized sourcing options. The component is listed as obsolete, so lead time and supply should not be assumed from general catalog availability. The verified product result describes an 8-SOIC instrument amplifier, and an inventory record identifies tube packaging and an obsolete lifecycle status.
Is INA121UAG4 in stock and what does it cost?
Current stock and transaction pricing for INA121UAG4 should be confirmed through the Request a Quote form on this page. The part is identified as obsolete, which makes current supply condition and lifecycle risk more important than a conventional catalog listing. The verified records include 8-SOIC packaging and tube packaging information, but they do not establish a current, quantity-break unit price for this exact order code.
How should an INA121UAG4 gain resistor be selected?
Select the INA121UAG4 gain-setting resistor using the gain equation and recommended resistor values in the Texas Instruments INA121 datasheet, then verify that the resulting gain fits the sensor signal and the available output common-mode range. Resistor tolerance and temperature coefficient contribute directly to gain error. Keep the resistor close to its designated gain pin, use a suitable low-noise resistor technology, and confirm that the chosen gain does not violate the amplifier's input or output range.

Data referensi kejuruteraan untuk INA121UAG4 — perbandingan, panduan rancangan, dan maklumat kesediaan

Panduan Pilihan

Choose INA121UAG4 when an existing design specifically uses the INA121's 1 V/V to 1000 V/V gain range, FET-input behavior, reference arrangement, and exact 8-pin SOIC pin functions. Consider INA126U or INA126UA when a gain range extending to 10000 V/V is required and their common-mode behavior fits the signal chain. Consider INA129U for high-impedance sensor applications where its input characteristics are preferable. None should be treated as an automatic replacement solely because the package is 8-pin SOIC. Compare the gain-resistor connection, input and output common-mode ranges, supply requirements, offset, bias current, CMRR, settling behavior, temperature grade, and lifecycle status. Since INA121UAG4 is obsolete, production selection also requires a written availability and continuity assessment.

Perbandingan dengan Gantian

Parametr Produk Ini INA126U INA126UA INA129U
Package 8-pin SOIC 8-pin SOIC 8-pin SOIC 8-pin SOIC
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Product Type FET-input instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier
Maximum Gain 1000 V/V 10000 V/V 10000 V/V 10000 V/V
Special Features Three-op-amp architecture and low-power operation Gain up to 10000 V/V Gain up to 10000 V/V Gain up to 10000 V/V

Penyeberangsung Jelas

  • Focused gain range for precision differential measurement (vsINA126U)
  • Established low-power FET-input architecture (vsINA129U)
  • Compact eight-pin surface-mount implementation (vsINA126UA)

Catatan Desain

Place the gain-setting resistor close to its designated INA121 pin and keep the input traces short, symmetrical, and away from switching nodes. Connect the amplifier's reference pin directly to a low-impedance analog ground for unipolar operation or to a carefully filtered precision midpoint for bipolar signals. A high-impedance reference node can introduce offset and noise, so avoid routing the reference connection beside digital clocks or power inductors.

Provide local supply bypass close to the device and maintain the required voltage difference between input, output, and supply pins at every selected gain. Higher gain does not simply increase output amplitude; it also narrows the usable input and output common-mode range. Validate the signal excursion against those limits across temperature and tolerance, and verify startup behavior if the measurement system must distinguish valid readings from an unpowered or settling amplifier.

Do not select INA121UAG4 solely from the 8-pin SOIC outline when comparing it with INA126U, INA126UA, or INA129U. Check the gain-resistor connection, input and output common-mode limits, supply range, reference configuration, and absolute maximum ratings. The three related candidates support gains up to 10000 V/V, whereas INA121UAG4 reaches 1000 V/V, so a footprint-compatible device may still be electrically unsuitable for the original board.

Use a solid ground reference and return sensor current directly to the analog supply ground without routing it through the measurement reference node. For bridge and shunt measurements, use paired input routing to minimize differential pickup from adjacent switching signals. Input filtering, if required, should preserve phase margin and sensor bandwidth; excessive series resistance can combine with input bias current to create gain error, while excessive capacitance can impair settling.

Maklumat Kesediaan

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
Bosong logam timbal
Unknown
Bosong halogen
Unknown
Mineral konflik
Unknown

The component listing identifies the part as ROHS3 compliant. No separate REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification statement was confirmed for this exact order code.

Data disahkan pada: 2026-11-14 — data yang disahkan dan disusun semula oleh pasukan kejuruteraan komponen XAIPART

Pencarian Berhubungan

INA121UAG4 datasheet INA121UAG4 pinout INA121UAG4 datasheet pdf INA121UAG4 8-SOIC INA121UAG4 specifications INA121UAG4 obsolete INA121UAG4 replacement INA121UAG4 equivalent INA121UAG4 vs INA126U INA121UAG4 vs INA129U Texas Instruments INA121UAG4 INA121UAG4 price INA121UAG4 stock INA121UAG4 application circuit INA121 instrumentation amplifier circuit

Komponen dan Tanda berkaitan

Texas Instruments INA121UAG4 INA121 INA126U INA126UA INA129U instrumentation amplifier differential amplifier analog signal-chain IC FET input three-op-amp architecture programmable gain common-mode rejection ratio input offset voltage input bias current quiescent current gain-setting resistor 8-pin SOIC SOIC package family surface mount bridge transducer current-sense shunt industrial sensor interface biomedical instrumentation RoHS
RFRC Saring Pantas
Isikan butiran lengkap — pasukan jualan kami akan bertindak balas dalam masa 24 jam
Nombor Bahagian Pengeluar Pakej QTY Harga Target Lengkap
✓
Pesan diskon sudah disubmit!

Kami akan bertindak balas kepada emel anda dalam tempoh 24 jam

1
RFQ Diserahkan
2
kutipan Diterima
3
Order Dipesan
4
Pembayaran
5
Dihantar
6
Diantar
Lihat Perincian RFQ