INA128UG4 - Low-Power Instrumentation Amplifier | TI
MPN: INA128UG4 ✓ AktifINA128UG4 Ringkasan
An instrumentation amplifier is a specialized analog amplifier that measures the voltage difference between two inputs while rejecting large signals common to both inputs. Its internal three-amplifier topology provides high input impedance, accurate differential gain, and flexible gain selection through an external gain-setting resistor. The INA128 belongs to the broader precision-amplifier hierarchy and is commonly used with resistive sensors, strain gauges, bridge transducers, and high-impedance analog front ends.
The INA128UG4 combines 130 dB CMRR with approximately 10 uV input offset voltage and 8 nV/sqrt(Hz) input noise. Its 700 uA supply current supports battery-powered and portable measurement systems where amplifier power consumption directly affects operating time. A 1.3 MHz bandwidth enables useful signal bandwidth, while a typical slew rate of 4 V/us supports accurate response to changing differential inputs. An external resistor on the gain-setting pins provides the gain relationship used for sensor conditioning.
The device uses a precision internal architecture that is effective in systems where unwanted common-mode voltage can be substantially larger than the differential signal of interest. Its low noise and high CMRR reduce errors in bridge-based measurements, while the SOIC-8 package simplifies assembly in conventional surface-mount designs. Operation from ±2.25 V to ±18 V allows use with dual low-voltage rails or higher-voltage analog supplies, subject to the absolute maximum ratings in the manufacturer datasheet.
Typical applications include weighing systems, industrial pressure and flow measurement, biomedical instrumentation, current-shunt monitoring, and laboratory sensor interfaces. In a bridge circuit, the amplifier can reject supply variation and large common-mode voltage while preserving the small differential output generated by the sensing element. The 700 uA quiescent current is particularly useful in portable equipment where each milliamp of supply demand can materially shorten battery life.
The principal design consideration is resistor selection for the gain-setting network. Use stable, low-temperature-coefficient resistors and place them close to the relevant device pins to minimize added noise and parasitic resistance. Confirm common-mode range, output swing, supply current, and input bias behavior against the operating conditions before committing to a high-gain configuration.
This page combines manufacturer specifications, package and pin information, sourcing guidance, parameter comparisons, and practical circuit-design notes. It also distinguishes confirmed pin-compatible alternatives from options that require additional electrical validation before production substitution.
Pilihan pengganti yang segera untuk INA128UG4 — sama paket, pin-pin kompatibel. Bahagian paket yang berbeza memerlukan kerja ulang PCB diasingkan.
Varietas dalam siri ini
Model serupa yang kompatibel dengan pengganti yang segera INA128UG4 (sama faktor bentuk dan kaki) — berbeza dalam Package, Common-Mode Rejection Ratio, Input Offset Voltage, Operating Temperature Range, Supply Voltage Range.
INA129U
✅ Masuk Drop-InHubungi untuk harga
Lihat Datasheet →INA129UA
✅ Masuk Drop-InHubungi untuk harga
Lihat Datasheet →INA128UG4 Penilaian maksimum & Ciri-ciri Elektrik
| Amplifier Type | Precision instrumentation amplifier |
| Number of Circuits | 1 circuit |
| Common-Mode Rejection Ratio | 130 dB |
| Arus Dalam Tentera | 700 uA |
| Gain-Bandwidth Product | 1.3 MHz |
| Input Offset Voltage | 10 uV |
| Input Noise Density | 8 nV/sqrt(Hz) |
| Slew Rate | 4 V/us |
| Supply Voltage Range | ±2.25 V to ±18 V |
| Typical Supply Voltage | ±15 V |
| Kemasan | 8-pin SOIC, 3.90 mm body width |
| Jenis Pemasangan | Surface mount |
| Bilangan Pin | 8 pins |
| Gain Configuration | External gain-setting resistor |
| Input Type | Differential |
| Product Description | Precision, low-power instrumentation amplifier |
Konfigurasi Pin INA128UG4
| Pin 1 | RG — Gain-setting resistor connection |
| Pin 2 | IN- — Inverting input |
| Pin 3 | IN+ — Non-inverting input |
| Pin 4 | V- — Negative supply connection |
| Pin 5 | REF — Reference voltage input |
| Pin 6 | OUT — Amplified output |
| Pin 7 | VS+ — Positive supply connection |
| Pin 8 | RG — Gain-setting resistor connection |
Aplikasi Biasa
INA128UG4 patut untuk 7 aplikasis: Strain-Gauge Bridge Measurement, Battery-Powered Sensor Interface, Industrial Pressure Transducer Interface, Precision Current-Shunt Monitor, Biomedical and Diagnostic Instrumentation, Laboratory Measurement Front End, Audio and Analog Measurement Interface.
Strain-Gauge Bridge Measurement
The INA128UG4 is appropriate for low-level strain-gauge bridges because its 130 dB CMRR suppresses supply and ground-related common-mode signals while its 10 uV offset and 8 nV/sqrt(Hz) noise help preserve small differential outputs. Place the amplifier across the bridge output and use a precision gain-setting resistor to establish the required differential gain. The 700 uA quiescent current also helps portable test systems conserve power. Confirm the bridge excitation, common-mode voltage, resistor tolerance, and output swing before applying gain.
Battery-Powered Sensor Interface
The INA128UG4 fits battery-powered sensor interfaces because its 700 uA quiescent current limits continuous amplifier demand while the 1.3 MHz bandwidth provides useful signal capacity for many slow-to-moderate sensor signals. The differential input arrangement rejects common-mode voltage generated by shared sensor returns or supply disturbances. Operation from ±2.25 V to ±18 V supports multiple rail architectures. Battery-life calculations should include the sensor, reference, gain resistor, and any output-conversion circuitry in addition to the amplifier itself.
Industrial Pressure Transducer Interface
For industrial pressure or displacement transducers, the INA128UG4 can amplify a small differential output while rejecting the larger common-mode voltage present at the sensor terminals. Its 130 dB CMRR improves rejection of interference common to both inputs, while the 8 nV/sqrt(Hz) noise density supports low-level signal chains. Use the external gain resistor close to the device and verify that the selected supply rails maintain the transducer output within the amplifier’s input and output ranges. Shielded routing and a clean ground reference remain important in long cable systems.
Precision Current-Shunt Monitor
The INA128UG4 is suitable for monitoring current through a shunt resistor when the voltage of interest is differential and small. The instrumentation-amplifier architecture reduces dependence on exact common-mode voltage, while 10 uV input offset and 8 nV/sqrt(Hz) input noise support accurate measurements of low shunt drops. The 1.3 MHz gain-bandwidth product gives adequate bandwidth for many power-monitoring applications. Check Kelvin connections, shunt dissipation, amplifier output swing, and whether the selected gain introduces excessive bandwidth or noise amplification.
Biomedical and Diagnostic Instrumentation
The low-noise, high-CMRR characteristics of the INA128UG4 make it suitable for biomedical front ends that measure small differential signals superimposed on larger physiological or electrode common-mode voltages. Its 700 uA quiescent current supports portable acquisition systems, and the SOIC-8 package simplifies compact analog boards. For patient-connected equipment, verify applicable isolation, leakage, electrode protection, and safety requirements separately. The amplifier itself does not replace the input protection, isolation, filtering, and system-level validation required in medical products.
Laboratory Measurement Front End
The INA128UG4 can form the input stage of a precision laboratory measurement system when the source produces a differential signal and high common-mode rejection is valuable. The 130 dB CMRR reduces errors from shared ground potential, while 10 uV offset and 8 nV/sqrt(Hz) noise support low-level measurements. Its dual-supply capability accommodates classic ±15 V laboratory architectures as well as lower-voltage systems. Select the gain carefully to keep the output within its swing limits and use a low-noise reference arrangement for accurate unipolar measurements.
Audio and Analog Measurement Interface
The INA128UG4 can serve as a low-noise differential input stage for audio and general analog measurement circuits where common-mode interference must be rejected. Its 8 nV/sqrt(Hz) input noise and 130 dB CMRR help preserve small signal information, while the 1.3 MHz bandwidth covers a useful portion of the audio range. Use the reference pin for midpoint bias in single-supply systems and confirm output headroom. Input protection and filtering should be selected according to the source impedance, cable length, and expected transient levels.
Data referensi kejuruteraan untuk INA128UG4 — perbandingan, panduan rancangan, dan maklumat kesediaan
Panduan Pilihan
Perbandingan dengan Gantian
| Parametr | Produk Ini | INA129U | INA129UA |
|---|---|---|---|
| Package | 8-SOIC | 8-SOIC | 8-SOIC |
| Brand | Texas Instruments | Texas Instruments | Analog Devices |
Penyeberangsung Jelas
- Higher documented common-mode rejection (vsINA129U)
- Low quiescent current for portable measurement (vsINA129UA)
- Defined low-noise input performance (vsINA129UA)
Catatan Desain
Route the INA128UG4 differential inputs as a compact, symmetric pair and connect the two inputs to the sensor or shunt through matched paths where practical. Keep the gain-setting resistor close to the gain pins because its resistance and associated parasitic capacitance affect gain accuracy and bandwidth. Connect the reference pin to a low-impedance reference or midpoint network, and avoid routing sensitive input traces near the output and supply nodes.
Check output swing, common-mode range, and supply headroom at the minimum and maximum operating conditions. A low quiescent current of 700 uA does not remove the need for supply decoupling, particularly when the amplifier drives downstream capacitance. Place the manufacturer-recommended input and output capacitors close to their pins and verify that the selected reference network does not consume unnecessary supply current.
Do not treat INA129U or INA129UA as automatic replacements merely because they use an 8-pin SOIC package. Confirm pin functions, gain-setting requirements, common-mode range, output swing, offset, noise, CMRR, bandwidth, and supply ratings against the manufacturer datasheets. Also account for component tolerances, sensor excitation drift, and reference-voltage accuracy when calculating end-to-end measurement error.
Maklumat Kesediaan
The available product and comparison pages do not explicitly establish the full compliance status of the exact INA128UG4 orderable MPN. Obtain the current manufacturer declaration for production qualification.