onsemi

LC450029PKB-XT - 106-Terminal LCD Driver | onsemi

MPN: LC450029PKB-XT ✓ Aktif
DIE Package
MOQ: 1 |

LC450029PKB-XT Ringkasan

onsemi LC450029PKB-XT is a general-purpose liquid-crystal display driver integrated circuit with 106 terminals, supplied as a rectangular, no-lead die. It is designed for industrial-temperature LCD applications in which a display subsystem requires a dedicated driver rather than general-purpose logic. The exact electrical ratings, display segment limits, interface timing, supply requirements, and operating-current limits are not stated in the available product material.

A liquid-crystal display driver is an interface IC that converts commands and display data into the voltage and bias signals required by an LCD panel. Within the electronics hierarchy, this device is a display driver, which is a specialized application of an interface IC and, more broadly, an integrated circuit. Its 106-terminal die format provides numerous connections for panel drive and control functions, making the package itself an important part of PCB and assembly planning.

The available product information identifies the LC450029PKB-XT as a general-purpose LCD display driver for industrial-temperature operation. It uses a rectangular die with no physical leads, and its 106 terminals determine the required land pattern and assembly process. Because this is a die rather than a conventional leaded or molded surface-mount package, the -XT ordering code, assembly method, exposed-bump or bonding details, and production programming requirements must be confirmed before a new PCB footprint is released.

LC450029PKB-XT is positioned for custom display modules, industrial panels, instrumentation, and equipment requiring a high-connection-count display controller. The 106-terminal interface distinguishes it from simple segment drivers intended for small character displays. Its industrial temperature grade supports equipment operating outside consumer-room-temperature conditions, although the exact minimum and maximum junction or ambient ratings require confirmation from the manufacturer datasheet.

The -XT version can be evaluated for new LCD panel designs, but its suitability depends on segment count, bias scheme, row and column drive architecture, timing compatibility, and supply voltage. These interface parameters determine whether the driver can operate with a given glass panel without adding external circuitry. Confirming them also prevents a mismatch between the controller, panel row/column organization, and the required drive waveforms.

Use the manufacturer pin-description and recommended-application material to establish the die pad layout, electrical connections, and assembly constraints. Do not derive the footprint from terminal count alone: die orientation, pad locations, and assembly tolerances require exact mechanical information. Also verify operating-temperature, supply-voltage, and display-timing limits before releasing a production design.

This product page consolidates the confirmed die-package, terminal-count, application, and lifecycle information with engineering guidance for display integration, package planning, qualification, and sourcing. It also distinguishes verified drop-in substitutions from look-alike listings so that engineers can evaluate compatibility without treating an unsupported equivalent as a PCB-compatible replacement.

Pilihan pengganti yang segera untuk LC450029PKB-XT — sama paket, pin-pin kompatibel. Bahagian paket yang berbeza memerlukan kerja ulang PCB diasingkan.

Tiada pilihan pengganti yang segera untuk produk ini.

Minta Alternatif

LC450029PKB-XT Spesifikasi

Product Type General-purpose LCD display driver
Manufacturer onsemi
Number of Terminals 106 terminals
Temperature Grade Industrial
Terminal Form No lead
Package Code DIE
Package Shape Rectangular
Jenis Pemasangan Die-level assembly

Panduan Konfigurasi Pin LC450029PKB-XT rectangular

Konfigurasi pin untuk LC450029PKB-XT (rectangular pakai). Penomeran pin, fungsi, dan garis bentuk koneksi ditakrifkan dalam dokumen pengeluar. Rujuk dokumen untuk kebentuk dan pedoman pengasman.

Garis bentuk pengecah pakai rectangular untuk LC450029PKB-XT

Tiada data garisan pin yang diperoleh untuk LC450029PKB-XT.

Rujuk kepada lembaran data untuk konfigurasi pin penuh.

Aplikasi Biasa

LC450029PKB-XT patut untuk 6 aplikasis: Industrial Instrumentation Displays, Test and Measurement Equipment, Process Control Panels, Medical Diagnostic Equipment, Automotive Diagnostic Displays, Point-of-Sale and Commercial Displays.

🏭

Industrial Instrumentation Displays

The onsemi LC450029PKB-XT fits industrial instrumentation that uses a custom glass panel rather than a small fixed character LCD. Its confirmed industrial temperature grade and 106 terminals distinguish it from simple segment drivers and allow the designer to evaluate a display with numerous panel connections. The controller must still be checked against the glass segment count, bias and duty ratios, update timing, and supply requirements. Because the device is a no-lead die rather than a molded package, PCB assembly planning must include the exact terminal map, die outline, and attach process rather than assuming a conventional component footprint.

🔧

Test and Measurement Equipment

The LC450029PKB-XT can be evaluated for test and measurement equipment that presents measurements, menus, or status information on a custom LCD. A 106-terminal general-purpose display driver offers extensive connectivity for a panel with many segments, while its industrial grade aligns with laboratory and production-test equipment intended for controlled operating environments. Engineering validation must confirm that the device's segment capacity, display timing, bias configuration, and drive outputs match the selected glass. The die-level 106-terminal construction also means the instrument designer must coordinate the PCB land pattern and assembly method with the exact manufacturer mechanical drawing.

🏭

Process Control Panels

The LC450029PKB-XT is a candidate for process-control panels that combine numeric readings, status indicators, operator prompts, and graphical feedback on one custom liquid-crystal panel. Its industrial temperature grade supports use in controlled factory equipment, and the 106-terminal count suits a high-connection-count display interface. Compatibility still depends on the glass panel's segment architecture, bias and duty ratios, interface timing, and voltage requirements. Before schematic release, compare those panel constraints with the manufacturer's electrical characteristics. Because no physical leads are present, the PCB and production process must accommodate the rectangular die and its documented terminal geometry.

💊

Medical Diagnostic Equipment

The LC450029PKB-XT may be considered for medical diagnostic equipment that uses a custom LCD to present measurements, menus, warnings, and test progress. The device's 106 terminals provide a broad interface for a multi-function display, while its industrial temperature grade can suit equipment installed in controlled indoor environments. Medical-system engineers must independently verify electrical safety, reliability, regulatory requirements, and display performance rather than relying on the general-purpose driver designation. Panel timing, segment capacity, supply requirements, and die-level assembly constraints remain essential qualification items. Use the manufacturer datasheet and application information to establish whether the driver matches the selected display glass.

🚗

Automotive Diagnostic Displays

The LC450029PKB-XT can be evaluated for an automotive diagnostic display that reports vehicle status, fault information, and service data on a custom LCD. Its 106-terminal general-purpose architecture offers enough panel connectivity for a more complex screen than a small segment driver, while its industrial temperature grade is relevant to controlled cabin equipment. Automotive use requires additional project-specific qualification because the confirmed material does not state AEC-Q100 status, supply limits, or lifetime ratings. Engineers must also confirm electromagnetic behavior, temperature extremes, display timing, and power requirements. The no-lead die format requires an approved die-level assembly and inspection process.

📺

Point-of-Sale and Commercial Displays

The LC450029PKB-XT is suitable for evaluation in custom point-of-sale terminals, payment peripherals, and commercial equipment with information-rich LCD panels. The 106 terminals provide extensive connectivity for a display containing many graphical or segmented elements, and the industrial grade supports controlled indoor terminals. Suitability depends on the glass panel's segment count, charge-sharing arrangement, bias and duty settings, and communication timing. Because this version is supplied as a rectangular die with no physical leads, a commercial-product designer should establish the exact die footprint, bonding process, inspection criteria, and rework strategy with the manufacturer before committing to a high-volume PCB layout.

What is the onsemi LC450029PKB-XT?
The onsemi LC450029PKB-XT is a general-purpose liquid-crystal display driver packaged as a rectangular, no-lead die with 106 terminals. According to the LC450029PKB-XT datasheet description, it is intended for industrial-temperature LCD equipment and belongs to the display-driver class of interface integrated circuits. Its large terminal count supports substantially more panel connections than a basic character-display driver, making it most relevant to custom instrumentation and industrial display modules.
How many terminals does the LC450029PKB-XT have?
The LC450029PKB-XT has 106 terminals. The product listing identifies the package code as DIE, the terminal form as no lead, and the package shape as rectangular. Because these connections are on a die rather than a molded package, engineers must obtain the exact terminal map and mechanical land pattern from the manufacturer documentation before committing the PCB footprint or defining the bonding and inspection process.
Is LC450029PKB-XT suitable for industrial displays?
Yes, the LC450029PKB-XT is identified as an industrial-temperature general-purpose LCD display driver. The industrial grade is appropriate for equipment intended to operate in a controlled industrial enclosure, but the exact minimum and maximum temperature limits are not stated in the available product summary. Confirm the full operating-temperature and electrical ratings in the manufacturer datasheet before using the device in safety-related or high-temperature equipment.
Where can I download the LC450029PKB-XT datasheet PDF?
The LC450029PKB-XT datasheet is available through the linked 25-page PDF document hosted by AllDataSheet, with the LC450029PKB-XT identified as an onsemi general-purpose LCD driver. Use the manufacturer's pin-description table, electrical-characteristics section, and recommended application diagram for final design release. The document identifier and revision are not stated in the product summary, so treat them as unverified until confirmed by onsemi.
Where can I find the LC450029PKB-XT pinout and die footprint?
The LC450029PKB-XT pinout must be taken from the manufacturer datasheet because it is supplied as a 106-terminal, no-lead rectangular die rather than a standard molded package. Terminal count alone does not define die orientation, pad geometry, or numbering direction. Obtain the exact die drawing and pin-description table from onsemi before creating the PCB land pattern, bonding fixture, or assembly inspection procedure.
Can LC450029PKB-XT drive a custom character LCD?
The LC450029PKB-XT can potentially support a compatible custom LCD, but segment count, row and column organization, duty ratio, bias ratio, and interface timing must match the device ratings. The 106-terminal package indicates a high-connection-count display driver, but no universal character-LCD compatibility can be inferred from that fact. Match the proposed glass panel against the manufacturer electrical-characteristics and timing tables before selecting the part.
What is the difference between a die package and a molded IC package?
A die package exposes an integrated circuit as an uncoated semiconductor die with terminals intended for bonding or assembly, whereas a molded IC package places the die in a protective plastic housing with external leads. The LC450029PKB-XT is listed as a rectangular DIE with no lead and 106 terminals. That difference affects land-pattern design, assembly process, moisture protection, inspection, repairability, and the volume handling required during production.
Is there a pin-compatible replacement for LC450029PKB-XT?
No verified pin-compatible replacement is established for the LC450029PKB-XT by the available cross-reference results. The search results identify cross-reference tools and the original part, but they do not name an alternative with a confirmed 106-terminal die footprint, matching display timing, and equivalent electrical ratings. Treat the target as an original-design choice until onsemi publishes an approved substitute or an engineering review confirms a candidate part-by-part.
What can replace the LC450029PKB-XT in an existing design?
An existing LC450029PKB-XT design should not be changed to an unverified substitute. A true replacement would need the same 106-terminal die footprint, pin functions, display-drive capability, supply range, timing, temperature grade, and assembly process. Because the available cross-reference results contain no named qualified equivalent, obtain an onsemi migration recommendation or validate a candidate against the complete datasheet and mechanical documentation before releasing a replacement.
LC450029PKB-XT vs a conventional LCD segment driver: which is better?
The LC450029PKB-XT is preferable when the design needs a high-connection-count, industrial-grade general-purpose display driver rather than a simple segment driver. Its 106-terminal die provides extensive panel connectivity, while a conventional segment driver is generally simpler and optimized for small fixed displays. The correct choice depends on the glass panel's segment count, duty and bias scheme, drive waveform, interface, and PCB assembly method.
When should designers choose the LC450029PKB-XT?
Choose the LC450029PKB-XT when a custom industrial LCD requires a general-purpose driver with 106 terminals and die-level assembly. It is less attractive for small fixed-character modules that can be served by a conventional segment driver because the die package requires more complex assembly planning. Confirm segment capacity, interface timing, supply requirements, temperature limits, and exact mechanical dimensions before finalizing the design.
What should be checked before mounting an LC450029PKB-XT die?
Before mounting the LC450029PKB-XT, verify the exact die outline, terminal map, orientation marks, assembly tolerances, and recommended bonding or attach process. Also check the panel's drive requirements against the device's segment count, bias, duty, timing, and supply specifications. The available product summary confirms 106 terminals and a rectangular no-lead die, but it does not provide the mechanical dimensions required for a production footprint.
How do I check LC450029PKB-XT LCD timing compatibility?
Check the LCD timing compatibility by comparing the panel row rate, column rate, frame period, update timing, charge-sharing behavior, and drive-waveform requirements with the LC450029PKB-XT timing specifications in the manufacturer datasheet. Also verify bias and duty settings, display-memory organization, and interface protocol. A matching terminal count alone does not establish that the driver can operate the selected glass panel.
Where can I request a quote for LC450029PKB-XT?
Use the Request a Quote form on this page to request current availability, MOQ, and lead time for the onsemi LC450029PKB-XT. Because the orderable item includes an -XT suffix, include that exact suffix and the required shipment or assembly format in the request. Obtain written confirmation of lot traceability, die revision, and temperature-grade configuration before issuing a production purchase order.
What are the key specifications engineers should know about LC450029PKB-XT?
The confirmed engineering facts are general-purpose LCD-driver functionality, 106 terminals, an industrial temperature grade, a no-lead terminal form, a rectangular DIE package code, and onsemi manufacture. The 106-terminal die is the principal mechanical distinction and requires exact bonding and land-pattern planning. Supply voltage, segment capacity, duty ratio, bias ratio, output drive, timing, and absolute temperature limits must be confirmed from the manufacturer datasheet before schematic or layout release.

Data referensi kejuruteraan untuk LC450029PKB-XT — perbandingan, panduan rancangan, dan maklumat kesediaan

Panduan Pilihan

Select the onsemi LC450029PKB-XT when a custom industrial LCD requires a high-connection-count general-purpose driver and the product can accommodate die-level assembly. Its confirmed 106 terminals, industrial temperature grade, rectangular no-lead die, and display-driver function make it more suitable for complex panels than a small fixed-character segment driver. Before committing, verify the glass segment count, bias and duty ratios, timing, supply, output-drive capability, and exact operating-temperature limits. A conventional segment driver is usually simpler for small displays. A molded-interface IC may simplify assembly when die bonding is undesirable, but it is not a drop-in substitute. No qualified pin-compatible alternative is established by the available cross-reference results, so the LC450029PKB-XT should remain the selected original part unless onsemi publishes an approved migration path or every mechanical, electrical, timing, and qualification requirement is independently demonstrated for a proposed replacement.

Perbandingan dengan Gantian

Parametr Produk Ini
Brand onsemi
Package Rectangular DIE, no lead
Terminal Count 106 terminals
Product Type General-purpose LCD display driver
Temperature Grade Industrial
Package Code DIE
Package Shape Rectangular
Terminal Form No lead

Catatan Desain

Do not create the PCB footprint from the 106-terminal count alone. Obtain the exact die outline, terminal numbering, pad coordinates, orientation marks, and assembly tolerances from onsemi. The confirmed rectangular, no-lead DIE package cannot be treated as a standard QFN, BGA, or leaded IC footprint, and a mismatch can cause bonding or orientation errors even when the electrical pin count is correct.

Confirm the custom LCD panel's segment count, row and column organization, duty ratio, bias ratio, refresh timing, and drive-waveform requirements against the LC450029PKB-XT electrical characteristics. A driver with the correct terminal count can still be unsuitable if its display-memory architecture or timing differs from the glass. Preserve margin for panel temperature, aging, controller latency, and operating-condition variation rather than checking only nominal timing.

Complete the power-tree review only after the supply voltage and operating-current limits are obtained from the manufacturer datasheet. Account for LCD bias generation, interface activity, panel loading, startup behavior, and the driver’s own consumption when sizing the supply. Decoupling requirements must also follow the manufacturer layout guidance; generic bulk-capacitor rules are not a substitute for the recommended values and placement.

Use the exact die dimensions and assembly construction to evaluate thermal performance rather than treating the device as a molded low-profile package. Determine junction-temperature limits, board construction, airflow, and expected dissipation from the manufacturer information. The industrial temperature designation does not by itself define the allowable ambient range, junction limit, or derating curve required for the finished equipment.

Maklumat Kesediaan

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Bosong logam timbal
Unknown
Bosong halogen
Unknown
Mineral konflik
Unknown

The available product material identifies an industrial temperature grade but does not state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. Confirm all compliance declarations for the exact -XT orderable configuration with onsemi.

Data disahkan pada: 2026-11-23 — data yang disahkan dan disusun semula oleh pasukan kejuruteraan komponen XAIPART

Pencarian Berhubungan

LC450029PKB-XT datasheet LC450029PKB-XT specifications LC450029PKB-XT pinout LC450029PKB-XT datasheet pdf onsemi LC450029PKB-XT LC450029PKB-XT 106 terminal die LC450029PKB-XT equivalent LC450029PKB-XT replacement LC450029PKB-XT cross reference LC450029PKB-XT application circuit LC450029PKB-XT footprint LC450029PKB-XT price LC450029PKB-XT stock

Komponen dan Tanda berkaitan

onsemi LC450029PKB-XT LC450029PKB liquid-crystal display driver LCD driver display driver interface IC integrated circuit semiconductor general-purpose LCD industrial display custom LCD panel 106-terminal die rectangular die no-lead package DIE package surface display assembly industrial temperature grade segment driver bias ratio duty ratio display timing liquid-crystal display instrumentation display process control panel
RFRC Saring Pantas
Isikan butiran lengkap — pasukan jualan kami akan bertindak balas dalam masa 24 jam
Nombor Bahagian Pengeluar Pakej QTY Harga Target Lengkap
✓
Pesan diskon sudah disubmit!

Kami akan bertindak balas kepada emel anda dalam tempoh 24 jam

1
RFQ Diserahkan
2
kutipan Diterima
3
Order Dipesan
4
Pembayaran
5
Dihantar
6
Diantar
Lihat Perincian RFQ