MAX202EESE+T - 120kbps RS-232 Transceiver | Analog Devices
MPN: MAX202EESE+T ✓ AktifMAX202EESE+T Ringkasan
An RS-232 transceiver is an interface IC that translates between digital logic levels and the voltage levels used by RS-232 equipment. Within the interface hierarchy, MAX202EESE+T belongs to the RS-232 transceiver family and functions as a physical-layer communications component. The integrated charge pump allows a modern system to communicate with legacy RS-232 peripherals without a separate negative supply, reducing component count and simplifying power-system design.
The device provides two transmit channels and two receive channels, allowing two signal directions to be implemented in one package. Its maximum stated data rate of 120kbps supports short-distance point-to-point serial links when used with an EIA/TIA-232E-compliant load. The ±15kV ESD HBM rating is the principal protection specification highlighted for applications where exposed connectors or cables can introduce electrostatic discharge transients.
The MAX202 architecture integrates the RS-232 line drivers, receivers, and charge-pump circuitry. Its receivers invert the incoming RS-232 signal so the associated digital interface operates with standard active-low logic conventions. This arrangement is suitable for connecting a controller UART or similar logic block to an RS-232 port while keeping the high-voltage interface function in one compact 16-pin package.
Typical applications include industrial serial controllers, point-of-sale equipment, test and measurement instruments, data-acquisition systems, and legacy computer peripherals. The part can also be used in service equipment that must communicate through an existing RS-232 port. For modern USB-to-RS-232 systems, it provides the physical RS-232 layer while a separate interface controller handles USB-to-serial protocol conversion.
Designers should follow the manufacturer's recommended charge-pump capacitor values and place them close to the corresponding pins. The narrow SOIC footprint requires careful orientation because the exposed connector ground, supply rails, and charge-pump components determine signal integrity. Confirm the exact lead assignments, recommended operating conditions, and PCB layout directly against the Analog Devices MAX202E datasheet before releasing a layout.
This product page organizes the core transceiver specifications, verified sourcing information, application guidance, package details, and same-package replacement candidates into one engineering-focused reference. It also identifies the electrical and lifecycle characteristics that should be checked before adopting MAX202EESE+T in a new RS-232 design.
Pilihan pengganti yang segera untuk MAX202EESE+T — sama paket, pin-pin kompatibel. Bahagian paket yang berbeza memerlukan kerja ulang PCB diasingkan.
Varietas dalam siri ini
Model serupa yang kompatibel dengan pengganti yang segera MAX202EESE+T (sama faktor bentuk dan kaki) — berbeza dalam ESD Protection, Supply Voltage, Product Type, Package, Maximum Data Rate.
MAX202EESE+
✅ Masuk Drop-InHubungi untuk harga
Lihat Datasheet →MAX202ECSE+T
✅ Masuk Drop-InHubungi untuk harga
Lihat Datasheet →MAX202ECSE.TG096
✅ Masuk Drop-InHubungi untuk harga
Lihat Datasheet →MAX203EWP+T
✅ Masuk Drop-In📋 Alternatif rujukan (tidak dalam katalog)
MAX203EEW+T
✅ Masuk Drop-In📋 Alternatif rujukan (tidak dalam katalog)
MAX202EESE+T Spesifikasi
| Transceiver Configuration | 2 driver and 2 receiver channels |
| Interface Standard | RS-232 |
| Communication Compliance | EIA/TIA-232E and CCITT V.28 |
| Maximum Data Rate | 120kbps |
| Tegangan Pemberi Arus | +5V |
| ESD Protection | ±15kV HBM |
| Charge Pump | Integrated |
| Driver Output Level | ±5V EIA/TIA-232E levels |
| Kemasan | 16-pin narrow SOIC |
| Kiraan Pin | 16 pins |
| Jenis Pemasangan | Surface mount |
| RoHS Compliance | unknown |
| REACH Compliance | unknown |
| AEC-Q100 Qualification | unknown |
Panduan Konfigurasi Pin MAX202EESE+T 16-pin narrow soic
Konfigurasi pin untuk MAX202EESE+T (16-pin narrow soic pakai). Penomeran pin, fungsi, dan garis bentuk koneksi ditakrifkan dalam dokumen pengeluar. Rujuk dokumen untuk kebentuk dan pedoman pengasman.
Tiada data garisan pin yang diperoleh untuk MAX202EESE+T.
Rujuk kepada lembaran data untuk konfigurasi pin penuh.
Aplikasi Biasa
MAX202EESE+T patut untuk 6 aplikasis: Industrial RS-232 Controller Interface, Point-of-Sale Terminal Communication, Test and Measurement Equipment, USB-to-RS-232 Adapter, Data Acquisition and Control System, Legacy Computer Peripheral Connection.
Industrial RS-232 Controller Interface
MAX202EESE+T fits a compact controller that must communicate with legacy RS-232 instruments through a 16-pin narrow-SOIC interface. Its two drivers and two receivers support bidirectional point-to-point links, while the 120kbps capability is appropriate for command and response traffic. The single +5V architecture removes the need for a separate negative supply, and the integrated charge pump keeps the external power arrangement simple. Designers should place the required charge-pump capacitors according to the manufacturer layout and provide a stable return path through the RS-232 connector.
Disebarkan
Point-of-Sale Terminal Communication
The MAX202EESE+T can provide the physical RS-232 link between a point-of-sale terminal and a peripheral that predates USB. Two transmit and two receive channels are useful for simultaneous command and status paths, while the 120kbps rating comfortably exceeds typical POS configuration traffic. Single +5V operation is convenient for compact equipment with limited power-supply space. The 16-pin narrow SOIC also keeps the interface area modest, although connector clearance and electrostatic-disaster protection remain important at the exposed cable connection.
Disebarkan
Test and Measurement Equipment
MAX202EESE+T is appropriate for laboratory instruments that expose a legacy RS-232 configuration port. The transceiver maintains EIA/TIA-232E and CCITT V.28 compatibility and supports rates up to 120kbps, making it suitable for instrument-control protocols carried over short cables. Its two full-duplex channels can handle command and measurement-result traffic, while ±15kV ESD HBM protection adds an interface-level safeguard when users connect external equipment. Product-level surge and cable protection may still be required for harsher environments.
Disebarkan
USB-to-RS-232 Adapter
MAX202EESE+T can implement the RS-232 side of a USB-to-serial adapter when paired with a USB controller that includes UART signaling. The MAX202 provides the two drivers, two receivers, integrated charge pump, and ±5V EIA/TIA-232E line levels needed at the connector. Its 120kbps capability is suitable for many low- and moderate-speed serial protocols. Board layout must separate connector-side energy from sensitive USB circuitry, and the adapter should include suitable protection for the exposed RS-232 port.
Disebarkan
Data Acquisition and Control System
MAX202EESE+T can connect a data-acquisition controller to external sensors, analyzers, or actuators that use RS-232. Two receive channels support data or status inputs, and two driver channels support commands or control outputs. The 120kbps maximum rate is appropriate for many supervisory control and data-logging links, while the single +5V supply simplifies integration with compact embedded equipment. System designers should verify protocol timing, ground reference, cable length, and connector protection because transceiver specifications alone do not define complete channel reliability.
Disebarkan
Legacy Computer Peripheral Connection
MAX202EESE+T provides a practical bridge for legacy computer peripherals that retain an RS-232 port while the surrounding product adopts modern digital interfaces. Its integrated charge pump supports a one-rail +5V implementation, reducing the space and assembly burden of external negative-voltage circuitry. The 16-pin narrow-SOIC package supports conventional PCB assembly, and the stated 120kbps rate covers many printer, programmer, and service-port protocols. Compatibility should be confirmed at the protocol, mechanical-connector, and electrical-grounding levels.
Disebarkan
Ringkasan Produk Disebarkan
Data referensi kejuruteraan untuk MAX202EESE+T — perbandingan, panduan rancangan, dan maklumat kesediaan
Panduan Pilihan
Perbandingan dengan Gantian
| Parametr | Produk Ini | MAX202EESE+ | MAX202ECSE+T | MAX202ECSE | MAX203EWP+T | MAX203EEW+T |
|---|---|---|---|---|---|---|
| Package | 16-pin narrow SOIC | 16-pin narrow SOIC | 16-pin narrow SOIC | 16-pin narrow SOIC | 16-pin narrow SOIC | 16-pin narrow SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Supply Voltage | +5V | +5V | +5V | +5V | +5V | +5V |
| Interface Standard | RS-232 | RS-232 | RS-232 | RS-232 | RS-232 | RS-232 |
| Charge Pump | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated |
Penyeberangsung Jelas
- Combines two full-duplex channels with single-supply operation (vsMAX202ECSE+T)
- Maintains the established MAX202E 120kbps performance class (vsMAX203EWP+T)
- Uses a compact 16-pin narrow-SOIC footprint (vsMAX202ECSE)
Catatan Desain
Place the charge-pump capacitors close to the pins identified in the Analog Devices MAX202E datasheet and keep their return-current paths short. The component depends on this network to generate the negative voltage required for RS-232 line levels, so long capacitor traces can increase output distortion or startup problems. Preserve the manufacturer's recommended capacitor values and observe the specified polarity and placement sequence.
Route the RS-232 driver outputs directly toward the connector while keeping them away from receiver inputs and sensitive logic nets. Maintain a continuous signal-ground reference and use the connector shell or chassis-ground strategy appropriate to the product. Although the MAX202E family provides ±15kV ESD HBM protection, the protection rating does not remove the need for an external surge-protection network in severe industrial environments.
Do not treat the MAX202EESE+T as a logic-level UART device; its pins connect to an RS-232 port, and the receiver and driver directions must be matched to the connector. Check that the transceiver is not being powered from a supply outside its recommended range and that both +5V and ground connections are low-impedance. Before production substitution, verify the complete pinout and charge-pump component values because ordering suffixes alone do not establish universal interchangeability.
Maklumat Kesediaan
The family is associated with EIA/TIA-232E and CCITT V.28 interface compliance. Specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals declarations were not confirmed in the manufacturer information or other cited records.