TJA1051T/3/CM - 5Mbps CAN Transceiver | NXP | SOIC-8
MPN: TJA1051T/3/CM ✓ AktifTJA1051T/3/CM Ringkasan
A CAN transceiver is an interface IC that converts digital controller signals into differential CAN bus levels and converts received bus levels into logic signals for the host controller. It belongs to the CAN physical-layer transceiver class within interface ICs, with the broader hierarchy being CAN transceiver, bus interface, interface IC, and semiconductor. The two-wire CAN bus supports robust communication among automotive controllers, industrial equipment, and embedded systems.
The TJA1051 family provides enhanced electromagnetic compatibility and electrostatic-discharge performance compared with earlier CAN transceiver generations. TJA1051T/3/CM supports Normal and Silent operating modes and includes passive behavior when unpowered. These characteristics help designers maintain defined bus behavior during reset, shutdown, fault-recovery, and startup conditions. The device is associated with 5 Mbit/s CAN operation, making it appropriate for systems whose controller supports classic CAN at that rate.
The TJA1051T/3 is backward compatible with the TJA1050 and allows direct connection to 3 V microcontrollers. The NXP product page lists a reel-and-reel packing configuration with a minimum package quantity of 2500 units, a minimum order quantity of 2500 units, and a stated lead time of 10 weeks. The Arrow listing identifies this device as an automotive AEC-Q100, normal/silent-mode, 5 V, 8-pin SOIC CAN transceiver.
Typical uses include vehicle body-control modules, automotive gateway controllers, industrial automation equipment, robotics controllers, and embedded CAN nodes. In an automotive ECU, the transceiver sits between a CAN controller and the CANH and CANL bus conductors, providing the differential drive and receive functions required by the physical bus. In industrial systems, its EMC characteristics and unpowered passive behavior help reduce installation and fault-recovery risks.
PCB design should preserve the short, symmetrical high-speed CAN traces associated with CANH and CANL, provide a solid ground reference, and place termination only at the two physical ends of the bus. Supply decoupling should be placed close to the device, while bus protection components should be selected to handle the voltage transients expected in the installation environment. The manufacturer pin-description and application information should govern the final land pattern and component arrangement.
This product page consolidates the manufacturer ordering information, technical attributes, practical application guidance, and verified drop-in considerations for TJA1051T/3/CM. It is intended to support component selection, footprint review, sourcing, and early hardware design rather than replace the complete NXP datasheet.
Pilihan pengganti yang segera untuk TJA1051T/3/CM — sama paket, pin-pin kompatibel. Bahagian paket yang berbeza memerlukan kerja ulang PCB diasingkan.
Varietas dalam siri ini
Model serupa yang kompatibel dengan pengganti yang segera TJA1051T/3/CM (sama faktor bentuk dan kaki) — berbeza dalam Package, Automotive Qualification, Electromagnetic Compatibility, Electrostatic Discharge Performance, Product Type.
TJA1051T/3,118
✅ Masuk Drop-In📋 Alternatif rujukan (tidak dalam katalog)
TJA1051T/3/1J
✅ Masuk Drop-InHubungi untuk harga
Lihat Datasheet →TCAN1051HVDQ1
✅ Masuk Drop-In✓ Ada di Stok
$1 / Unit
Lihat Datasheet →TJA1042T/3,112
✅ Masuk Drop-In📋 Alternatif rujukan (tidak dalam katalog)
TJA1051T/3/CM Spesifikasi
| Product Type | High-speed CAN transceiver |
| Maximum CAN Data Rate | 5 Mbit/s |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Microcontroller Interface Compatibility | 3 V to 5 V |
| CAN Bus Configuration | Two-wire CAN bus |
| Operating Modes | Normal and Silent |
| Unpowered Behavior | Passive |
| Kemasan | 8-pin SOIC |
| Jenis Pemasangan | Surface mount |
| Packing Format | Reel, 13 inch |
| Minimum Package Quantity | 2500 units |
| Minimum Order Quantity | 2500 units |
| Manufacturer Lead Time | 10 weeks |
| Automotive Qualification | AEC-Q100 Grade 1 |
| Electromagnetic Compatibility | Enhanced compared with earlier TJA generations |
| Electrostatic Discharge Performance | Enhanced compared with earlier TJA generations |
| Backward Compatibility | Compatible with TJA1050 |
Panduan Konfigurasi Pin TJA1051T/3/CM 2500 units
Konfigurasi pin untuk TJA1051T/3/CM (2500 units pakai). Penomeran pin, fungsi, dan garis bentuk koneksi ditakrifkan dalam dokumen pengeluar. Rujuk dokumen untuk kebentuk dan pedoman pengasman.
Tiada data garisan pin yang diperoleh untuk TJA1051T/3/CM.
Rujuk kepada lembaran data untuk konfigurasi pin penuh.
Aplikasi Biasa
TJA1051T/3/CM patut untuk 6 aplikasis: Automotive Body Control Module, Vehicle Gateway Controller, Industrial Automation Controller, Robotics Control Network, Embedded Sensor Node, Diagnostic Test Equipment.
Automotive Body Control Module
The TJA1051T/3/CM fits an automotive body-control module that communicates over a two-wire CAN network at rates up to 5 Mbit/s. Its 4.5 V to 5.5 V transceiver supply supports conventional 5 V automotive electronics, while direct 3 V microcontroller compatibility simplifies connections to suitable low-voltage controllers. The passive unpowered behavior helps prevent the transceiver from disturbing the bus during reset or power transitions. Its AEC-Q100 Grade 1 identification makes it appropriate for programs requiring that qualification level.
Disebarkan
Vehicle Gateway Controller
A vehicle gateway controller often connects CAN traffic from separate vehicle domains, making reliable bus interface and reset behavior important. The TJA1051T/3/CM provides a 5 Mbit/s classic CAN physical layer with enhanced EMC and ESD performance relative to earlier TJA generations. Its passive state when unpowered reduces unwanted bus activity during controller startup, while Silent mode supports diagnostics or controlled bus states. The 8-pin SOIC format keeps the interface compact for gateway PCB layouts.
Disebarkan
Industrial Automation Controller
The TJA1051T/3/CM is suitable for an industrial automation controller that connects sensors, actuators, and motor-control subsystems through a CAN network. Its 5 Mbit/s capability supports high-rate controller traffic, while the 3 V to 5 V microcontroller compatibility allows use with suitable low-voltage embedded controllers. Enhanced EMC performance is valuable in factory environments containing motors and switching equipment. Board-level surge protection and verified termination should still be designed around the installation's cable length and fault conditions.
Disebarkan
Robotics Control Network
A robot controller can use the TJA1051T/3/CM to bridge a CAN protocol controller to motor and sensor nodes distributed across the machine. The 5 Mbit/s rate supports timely command and status traffic, and the 8-pin SOIC package leaves more board area for processor, memory, and power circuitry. Passive unpowered behavior is useful during emergency stops or controller resets because it avoids unintended transceiver activity. In mobile robots, the CAN wiring should remain protected from motor transients and mechanically routed away from high-current switching paths.
Disebarkan
Embedded Sensor Node
The TJA1051T/3/CM can connect a compact embedded sensor node to a CAN-based sensing backbone. Its direct 3 V microcontroller compatibility permits use with suitable 3 V controllers, while the transceiver itself operates from 4.5 V to 5.5 V. The low pin-count SOIC-8 package is practical for space-constrained sensor electronics, and Normal and Silent modes provide operational control for measurement and maintenance states. The design must ensure that unpowered passive behavior and termination remain acceptable for the complete network.
Disebarkan
Diagnostic Test Equipment
The TJA1051T/3/CM can provide the CAN physical layer in diagnostic equipment intended to communicate with embedded automotive or industrial controllers. Its 5 Mbit/s capability covers high-speed classic CAN test traffic, and Silent mode can help isolate node behavior during selected diagnostic procedures. The 8-pin SOIC package is compatible with compact multi-channel test hardware. Engineers should use the manufacturer application guidance to verify termination, bus-fault handling, and logic timing before automating repetitive bus tests.
Disebarkan
Ringkasan Produk Disebarkan
Data referensi kejuruteraan untuk TJA1051T/3/CM — perbandingan, panduan rancangan, dan maklumat kesediaan
Panduan Pilihan
Perbandingan dengan Gantian
| Parametr | Produk Ini | TJA1051T/3,118 | TJA1051T/3/1J | TCAN1051 | TJA1042T/3,112 |
|---|---|---|---|---|---|
| Package | SOIC-8 | SOIC-8 | SOIC-8 | SOIC-8 | SOIC-8 |
| Brand | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | Texas Instruments | NXP Semiconductors |
| Product Type | High-speed CAN transceiver | High-speed CAN transceiver | High-speed CAN transceiver | CAN transceiver | High-speed CAN transceiver |
Penyeberangsung Jelas
- Direct low-voltage controller interface (vsTJA1042T/3,112)
- Defined passive behavior when unpowered (vsTCAN1051)
- Third-generation EMC and ESD improvement (vsTJA1050)
Catatan Desain
Route CANH and CANL as a closely coupled differential pair with continuous ground reference and minimize stub branches. Place the transceiver close to the bus connector or protection network so transient current is diverted before reaching the IC. Follow the NXP application circuit and the SOIC-8 land pattern for decoupling placement. Do not create unequal copper geometries around the pair, because impedance discontinuities can produce reflections at the supported 5 Mbit/s data rate.
Decouple the 4.5 V to 5.5 V transceiver supply close to the device with the capacitance and placement specified by the NXP datasheet. Keep the CAN bus pins and protection components physically separated from noisy power-conversion paths. The /3 variant can interface with a 3 V controller, but that interface compatibility does not permit operating the transceiver itself below 4.5 V. Verify the controller's TXD and RXD levels against the transceiver thresholds before enabling the bus.
Do not confuse the TJA1051T/3 controller-interface feature with a 3.3 V transceiver supply requirement. The transceiver still requires 4.5 V to 5.5 V, and the host controller must meet the TXD and RXD logic levels. Also avoid adding termination resistors indiscriminately: a nominal 120 ohm termination should appear across CANH and CANL only at the two physical ends of the bus, not at every node.
Use the transceiver's Normal and Silent modes according to the system state machine rather than driving TXD arbitrarily during reset. Silent mode preserves bus reception while preventing normal transmission, whereas passive unpowered behavior addresses a different operating condition. Review controller reset timing and fault-recovery behavior so the host software can prevent unintended arbitration or error frames when the transceiver supply changes.
Maklumat Kesediaan
The Arrow product listing identifies TJA1051T/3/CM as AEC-Q100 Grade 1 automotive qualified. Other environmental and material-compliance declarations are not established here.