1336F-BRF100-AA-EN - 10HP 380-480VAC AC Drive
MPN: 1336F-BRF100-AA-EN ✓ Active| Qty | Unit Price | Extended |
|---|---|---|
| 1 | $0 | $0.00 |
| 10 | $0 | $0.00 |
| 100 | $0 | $0.00 |
| 500 | $0 | $0.00 |
| 1,000 | $0 | $0.00 |
1336F-BRF100-AA-EN Overview
An adjustable-frequency AC drive, or VFD, is a power-conversion device that varies motor speed and torque by controlling the frequency and voltage supplied to a three-phase AC motor. In the broader hierarchy, it belongs to industrial motor control and power-management equipment rather than a small-signal semiconductor. The 1336 PLUS II family is microprocessor based and uses adjustable-frequency PWM control to regulate motor behavior for pumps, fans, conveyors, mixers, and other industrial loads.
Verified listings identify the target as a 10HP / 7.5kW unit with 380–480V AC operation, constant-torque current of 10.8A, variable-torque current of 14.7A, IP20 / NEMA 1 enclosure protection, English language documentation, and Allen Bradley branding. A related listing also identifies 16.4A constant-torque and 22.4A variable-torque current at the 380/480V rating, so the exact input-current interpretation should be confirmed against the relevant selection-table context before design approval.
The drive's practical value is integration: motor control, adjustable output, digital programming, diagnostics, and protective functions are consolidated into a wall-mounted industrial unit. Rockwell literature identifies the 1336 PLUS II as an adjustable-frequency AC drive family, while the supplied manual excerpt states that the publication contains planning, installation, wiring, and diagnostic information. These functions make it suitable for retrofit and expansion of motor-control panels where a complete drive assembly is preferred over discrete power components.
Before installation, confirm the motor rating, supply voltage, short-circuit protection, grounding, motor insulation, load type, acceleration and deceleration settings, and environmental conditions. The IP20 enclosure is not a hazardous-location rating and should not be assumed suitable for wet, dusty, explosive, or corrosive environments without additional enclosure protection. Use the manufacturer installation guidance and verify the complete catalog configuration before ordering.
This page combines verified distributor and manufacturer-document data with application guidance and configuration cautions. It does not substitute for the manufacturer's selection guide, wiring diagram, user manual, or site-specific engineering review.
Drop-in alternatives for 1336F-BRF100-AA-EN — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
Quick Comparison Tool — Select alternative parts for side-by-side comparison:
1336F-BRF100-AA-EN-L6
✅ Drop-In📋 Reference alternative (not in catalog)
1336F-BRF100-AA-EN-HASB
✅ Drop-In📋 Reference alternative (not in catalog)
1336F-BRF100-AA-EN-HCS1-L6
✅ Drop-In📋 Reference alternative (not in catalog)
1336F-BRF100-AA-EN-HAS2-L4
✅ Drop-In📋 Reference alternative (not in catalog)
1336F-BRF100-AA-EN-GMS6
✅ Drop-In📋 Reference alternative (not in catalog)
1336F-BRF100-AA-EN-HCS1-LA2-LA3-L6
✅ Drop-In📋 Reference alternative (not in catalog)
1336F-BRF100-AA-EN Maximum Ratings & Electrical Characteristics
| Product Type | Adjustable-frequency AC drive |
| Series | 1336 PLUS II |
| Nominal Power | 10 HP / 7.5 kW |
| AC Input Voltage | 380–480 V AC |
| DC Input Voltage | 513–620 V DC |
| Input Frequency | 50/60 Hz |
| Input Phase | 3 phase |
| Constant-Torque Input Current | 10.8 A |
| Variable-Torque Input Current | 14.7 A |
| Alternative Listed Constant-Torque Current | 16.4 A |
| Alternative Listed Variable-Torque Current | 22.4 A |
| Enclosure Protection | IP20 / NEMA 1 |
| Frame Size | A4 |
| Control Language | English |
| Common-Mode Choke Option | Blank for F and G frames |
| Enclosure Type | Wall mounted |
| Motor Control | Adjustable-frequency PWM AC motor control |
| Torque Application | Constant torque or variable torque |
| Sensorless Vector Control | Identified for the related 1336F-BRF100-AA-EN-L6 configuration |
| Programming Interface | Digital programming interface |
| Fault Diagnostics | Advanced fault diagnostics |
| Compliance References | EN 50081-1, EN 50081-2, EN 55011 Class A, EN 55011 Class B, EN 50082-1, EN 50082-2, EN 60204-1, PREN 50178 |
1336F-BRF100-AA-EN standard Pin Configuration Guide
Pin configuration for 1336F-BRF100-AA-EN (standard package). This power device features gate, drain, and source terminals. For non-polarized packages, refer to the manufacturer datasheet for exact pin 1 orientation and footprint details. Common applications include power supply design, motor driving, and load switching.
No detailed pinout data available for 1336F-BRF100-AA-EN.
Refer to the datasheet for full pin configuration.
Typical Applications
1336F-BRF100-AA-EN is suitable for 6 applications: Industrial Pump Control, Conveyor and Material Handling, Fan and HVAC Equipment, Mixer and Agitator Control, Machine Tool and Machinery Retrofit, Pump and Fan Energy Management.
Industrial Pump Control
The 1336F-BRF100-AA-EN fits pump applications where adjustable motor speed is useful for flow or pressure control. Its verified 10HP / 7.5kW rating and 380–480V AC three-phase input suit appropriately sized industrial pump systems. The drive can be installed in a protected IP20 / NEMA 1 panel, while the engineer must confirm motor voltage, full-load current, starting method, process inertia, and required control signals. Compared with fixed-speed operation, adjustable-frequency control can reduce unnecessary energy use when the pump process permits variable flow.
Recommended
Conveyor and Material Handling
For conveyors, the 1336F-BRF100-AA-EN provides a platform for adjustable-speed three-phase motor control in a 10HP / 7.5kW range. The 380–480V AC supply rating and IP20 / NEMA 1 enclosure suit protected industrial installations, but belt load, starting torque, acceleration, braking, and mechanical resonance must be evaluated before commissioning. A variable-frequency drive can help coordinate conveyor speed with upstream and downstream equipment, while protective functions and proper input fusing remain essential for reliable operation.
Recommended
Fan and HVAC Equipment
The 1336F-BRF100-AA-EN is applicable to industrial fans and HVAC auxiliaries that benefit from adjustable motor speed. The verified 10HP / 7.5kW power class and 380–480V AC input allow the drive to support appropriately sized three-phase fan motors, subject to motor current and enclosure limits. Speed adjustment can align airflow with process demand, but the design must check fan affinity laws, starting current, duct pressure, acoustic limits, and the need for thermal protection. The IP20 enclosure should be installed in a suitable protected control environment.
Recommended
Mixer and Agitator Control
A mixer or agitator can benefit from the adjustable-frequency control offered by the 1336F-BRF100-AA-EN when process speed must be varied for mixing quality, shear, or throughput. The drive's 10HP / 7.5kW rating is appropriate only when the motor and gearbox load fall within the verified operating range. Commissioning should establish safe minimum and maximum speeds, acceleration profiles, torque limits, and restart behavior. Because viscous or jammed loads can create high mechanical stress, overload protection, emergency stopping, and suitable motor thermal protection must be verified.
Recommended
Machine Tool and Machinery Retrofit
The 1336F-BRF100-AA-EN can support a retrofit of an appropriately rated three-phase machine motor when the existing panel requires a complete adjustable-frequency drive assembly. Its 10HP / 7.5kW rating, 380–480V AC input, and IP20 / NEMA 1 enclosure are useful for protected industrial panels, but retrofit success depends on motor insulation, load inertia, braking requirements, control logic, and safety circuitry. Confirm that replacement option codes match the original machine documentation and that the drive does not introduce incompatible control signals or communication assumptions.
Recommended
Pump and Fan Energy Management
The 1336F-BRF100-AA-EN supports energy-management strategies in which fan or pump output is varied according to demand instead of running continuously at full speed. The verified drive rating is 10HP / 7.5kW with 380–480V AC three-phase input, so the connected motor must remain within the approved current and mechanical limits. A controls engineer should define process sensors, minimum speed limits, ramp times, fault response, and bypass strategy. The drive should be installed in a protected panel, since IP20 / NEMA 1 does not indicate outdoor or hazardous-location suitability.
Recommended
Recommended Products Summary
Engineering reference data for 1336F-BRF100-AA-EN — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | 1336F-BRF100-AA-EN-L6 | 1336F-BRF100-AA-EN-HASB | 1336F-BRF100-AA-EN-HCS1-L6 | 1336F-BRF100-AA-EN-HAS2-L4 | 1336F-BRF100-AA-EN-GMS6 |
|---|---|---|---|---|---|---|
| Brand | Rockwell Automation / Allen Bradley | Rockwell Automation / Allen Bradley | Rockwell Automation / Allen Bradley | Rockwell Automation / Allen Bradley | Rockwell Automation / Allen Bradley | Rockwell Automation / Allen Bradley |
| Package | A4 frame / IP20 NEMA 1 enclosure | A4 frame / IP20 NEMA 1 enclosure | A4 frame / IP20 NEMA 1 enclosure | A4 frame / IP20 NEMA 1 enclosure | A4 frame / IP20 NEMA 1 enclosure | A4 frame / IP20 NEMA 1 enclosure |
| Rated Power | 10 HP / 7.5 kW | 10 HP / 7.5 kW | 10 HP / 7.5 kW | 10 HP / 7.5 kW | 10 HP / 7.5 kW | 10 HP / 7.5 kW |
| AC Input Voltage | 380–480 V AC | 380–480 V AC | 380–480 V AC | 380–480 V AC | 380–480 V AC | 380–480 V AC |
| Control Option | English-language 1336 PLUS II configuration | 115V AC control / L6 option | Digital potentiometer-related option details | Analog potentiometer programming option | Digital potentiometer option | GM6 snap-in cradle option |
Key Differentiators
- Complete 10HP / 7.5kW industrial drive platform (vs 1336F-BRF100-AA-EN-L6)
- Documented A4 / IP20 NEMA 1 configuration (vs 1336F-BRF100-AA-EN-HCS1-L6)
- Explicit configuration control (vs 1336F-BRF100-AA-EN-GMS6)
- Cross-reference caution for replacements (vs 1336F-BRF100-AA-EN-HAS2-L4)
Design Notes
Validate the complete power path before energization: confirm a 380–480V AC three-phase supply, properly rated branch protection, protective-earth continuity, and a motor whose voltage, current, and frequency rating match the selected drive. The supplied listings show 10.8A constant-torque and 14.7A variable-torque current for the target, while another listing shows 16.4A and 22.4A; reconcile that difference with the applicable selection-table context before sizing conductors and fuses.
The target is listed as an IP20 / NEMA 1 enclosure, so install it in a protected control panel and maintain the manufacturer's ventilation and clearance requirements. Confirm ambient temperature, enclosure heating from the motor and cabinet, cable sizing, and any required panel filtering. Do not assume that the enclosure rating permits outdoor, washdown, dusty, corrosive, or explosive-area use; use an appropriately rated enclosure or separate drive cabinet when conditions exceed the documented installation environment.
Do not substitute the drive using only the 10HP rating. Option suffixes such as L6, HASB, HCS1-L6, HAS2-L4, and GMS6 indicate configuration differences that can affect control voltage, programming, feedback, mechanical mounting, or cradle arrangement. Verify the complete catalog number, option codes, motor data, communications, control I/O, braking requirements, and existing panel drawings before ordering or replacing a unit.
Plan the installation using the manufacturer's wiring and clearance guidance rather than a generic terminal layout. Keep motor and control wiring appropriately separated, provide dependable protective-earth paths, route control cables away from high-interference power conductors, and use the specified ferrules, shields, and cable glands where applicable. The supplied installation manual excerpt specifically calls attention to the installation guidelines in Appendix C of publication 1336 PLUS-5.3.
Commission from a controlled state and verify motor rotation, direction, minimum and maximum frequency, acceleration and deceleration, nominal speed, full-load current, overload behavior, fault reset, and emergency-stop integration before connecting the process load. A drive can produce controlled acceleration but cannot compensate for an undersized motor, incorrect grounding, inadequate branch protection, unsuitable motor insulation, or a mechanical load that exceeds available torque.
Compliance Information
The supplied Rockwell technical literature identifies EN 50081-1, EN 50081-2, EN 55011 Class A, EN 55011 Class B, EN 50082-1, EN 50082-2, IEC 801-1, IEC 801-2, IEC 801-3, IEC 801-4, IEC 801-6, IEC 801-8, EN 60204-1, and PREN 50178 in relation to emissions, immunity, low-voltage, and installation requirements. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status were not supplied. AEC-Q100 is not applicable to this industrial drive category based on the supplied data.