Fuji Electric

6MBI300U4-120 - 1200V 300A 6-in-1 IGBT Module | Fuji Electric

MPN: 6MBI300U4-120 ✓ Active
In Stock Ships in 1-3 business days
1.2 kV Vdss 300 A Id
Contact for pricing
MOQ: 1 |
Price updated: 2026-10-11
Volume Pricing
Qty Unit Price Extended
1 $0 $0.00
10 $0 $0.00
100 $0 $0.00
500 $0 $0.00
1,000 $0 $0.00
ℹ️ All prices are in USD

6MBI300U4-120 Overview

The Fuji Electric 6MBI300U4-120 is a 1200 V, 300 A U-series IGBT power module in a six-in-one (6-unit) package, integrating a three-phase inverter bridge with built-in thermistor temperature sensing and 29 terminals for high-power conversion.

An IGBT (Insulated Gate Bipolar Transistor) module combines multiple IGBT dies and freewheeling diodes on an isolated substrate within a single molded housing, sitting at the top of the power semiconductor hierarchy: discrete IGBT -> IGBT chip set -> power module -> power conversion system. Modules simplify thermal design, reduce stray inductance, and provide certified isolation between the silicon and the heatsink surface.

Key features of the 6MBI300U4-120 include a collector-emitter voltage rating of 1.2 kV, a maximum collector current of 450 A (absolute maximum), high-speed voltage-drive switching, and a low-inductance module structure that minimizes voltage overshoot during turn-off. The integrated thermistor enables real-time heatsink temperature monitoring for protection and derating logic, and the maximum operating junction temperature is 150 C.

The U-series construction uses Fuji Electric's optimized IGBT and FWD chips for a favorable trade-off between conduction losses (low VCE(sat)) and switching losses, making the module well suited to hard-switched PWM inverters driven by standard gate drivers. The low-inductance layout supports fast di/dt events without excessive transient voltages when paired with proper DC-link snubbering.

Typical applications include three-phase AC motor drives (VFDs), servo amplifiers, industrial UPS systems, welding power supplies, and renewable-energy power conversion stages operating from 1200 V-class DC buses. The 300 A continuous rating with 450 A peak capability covers mid- to high-power inverter stages in the tens of kilowatts range.

Design consideration: always operate within absolute maximum ratings for voltage, current, and temperature, and connect an adequate fuse or circuit protector as required by the datasheet safety guidance; verify square operating area limits against your worst-case load and fault conditions.

This page synthesizes distributor availability, drop-in variant alternatives, comparison data, and practical design notes not consolidated in the manufacturer datasheet.

Drop-in alternatives for 6MBI300U4-120 — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

6MBI300U4-120-01

✅ Drop-In
📦 6-in-one IGBT module (U4 package)
suffix variant of the same base module, identical 1200 V / 300 A rating and package construction

📋 Reference alternative (not in catalog)

6MBI300U4-120-50

✅ Drop-In
📦 6-in-one IGBT module (U4 package)
suffix variant of the same model, distributor-listed as same 300 A / 1200 V spec

📋 Reference alternative (not in catalog)

6MBI300U-120

✅ Drop-In
📦 6-in-one IGBT module (U package)
same 1200 V / 300 A 6-in-one U-series rating but no built-in thermistor in base U-series, temperature sense terminals differ

📋 Reference alternative (not in catalog)

6MBI450U4-120

✅ Drop-In
📦 6-in-one IGBT module (U4 package)
same family but 450 A class vs 300 A (-33% current rating difference), verify case size and cooling

📋 Reference alternative (not in catalog)

6MBI600U4-120

✅ Drop-In
📦 6-in-one IGBT module (U4 package)
same family but 600 A class vs 300 A (double current rating), larger case and higher thermal demand

📋 Reference alternative (not in catalog)

6MBI300U4-120 Maximum Ratings & Electrical Characteristics

Manufacturer Fuji Electric
Product Type IGBT Module (6-in-1, three-phase bridge)
Collector-Emitter Voltage (VCES) 1.2 kV
Collector Current Rating (DC) 300 A
Maximum Collector Current (peak) 450 A
Series U-Series
Configuration 6-in-one package (inverter bridge)
Terminal Count 29
Maximum Operating Temperature 150 C
Built-in Thermistor Yes (heatsink temperature sensing)
Switching Type High speed switching, voltage drive
Module Structure Low inductance module structure
Mounting Type Chassis-mount / screw-terminal power module
Datasheet Length 14 pages

6MBI300U4-120 standard Pin Configuration Guide

Pin configuration for 6MBI300U4-120 (standard package). This power device features gate, drain, and source terminals. For non-polarized packages, refer to the manufacturer datasheet for exact pin 1 orientation and footprint details. Common applications include power supply design, motor driving, and load switching.

standard package pinout diagram for 6MBI300U4-120

No detailed pinout data available for 6MBI300U4-120.

Refer to the datasheet for full pin configuration.

Typical Applications

6MBI300U4-120 is suitable for 6 applications: Three-Phase Motor Drives (VFD), Industrial UPS / Inverter Power Stages, Welding Power Supplies, Renewable Energy Power Conversion, Servo Amplifiers and Motion Control, Test and Power Supply Equipment.

🏭

Three-Phase Motor Drives (VFD)

The 6MBI300U4-120 fits three-phase variable frequency drives because its 6-in-one package integrates the complete inverter bridge: six 1200 V IGBTs with freewheeling diodes rated 300 A continuous and 450 A peak. In a VFD, the module sits between the DC link capacitor bank and the motor output terminals, switched by PWM gate drivers at carrier frequencies typically from a few kHz upward. Its low-inductance structure limits turn-off voltage overshoot at fast di/dt, protecting against VCE spikes above the 1200 V rating on stiff DC buses. The built-in thermistor feeds heatsink temperature to the drive controller for derating and over-temperature trip, a key protection in motor drives with widely varying load profiles. Power dissipation combines conduction losses (VCE(sat) times phase current) and switching losses scaling with carrier frequency, so designers balance switching speed against thermal budget per the Fuji Electric datasheet.

⚡

Industrial UPS / Inverter Power Stages

Uninterruptible power supply inverter stages benefit from the 6MBI300U4-120's 1200 V blocking voltage and 300 A rating, which cover battery bus architectures and high-power online UPS frames in the tens of kVA range. The module's integrated three-phase bridge reduces assembly complexity compared with discrete IGBT solutions, lowering stray inductance and improving fault survivability during battery transfer events. The built-in thermistor gives the UPS controller continuous heatsink feedback so overload and short-time ratings can be managed safely. In UPS use, switching is usually at moderate carrier frequencies to limit switching losses during extended inverter operation, and the voltage-drive gate interface works with standard isolated drivers. Fuji Electric's datasheet requires operation strictly within absolute maximum ratings and connection of an adequate fuse or protector, which in UPS practice maps to fast semiconductor fuses on the DC link protecting the 450 A absolute maximum device limit.

🔧

Welding Power Supplies

High-power welding inverters demand robust, low-inductance switching modules; the 6MBI300U4-120's 1200 V / 300 A class and low-inductance package structure directly address this. In arc-welding inverters, the module switches DC-link energy into a transformer at high frequency, and the 450 A absolute maximum capability provides headroom for the short-circuit-prone nature of arc loads. The integrated thermistor monitors heatsink temperature during high duty-cycle welding, where average losses remain high for extended periods. Because welding supplies operate from rectified three-phase industrial mains, the 1200 V rating gives appropriate margin on the rectified bus. Voltage-drive gating simplifies the driver electronics needed for fast short-circuit shutdown, a critical requirement when the arc creates near-short conditions. Designers must apply the datasheet's fuse/protector guidance so that fault energy is cleared before die-level destruction thresholds are exceeded.

💡

Renewable Energy Power Conversion

Central inverters and energy-storage converters operating from 1200 V-class DC strings can deploy the 6MBI300U4-120 as the main three-phase bridge. Its 300 A continuous rating supports mid-power inverter stages, while the low-inductance construction is important in solar and storage applications where long DC busbars between the string combiner, capacitors, and module otherwise create large overshoot during turn-off. The built-in thermistor supports the field reliability requirements of outdoor converters, enabling thermal derating strategies tied to ambient and cooling conditions. High-speed voltage-drive switching allows reasonable efficiency at the moderate switching frequencies typical of grid-tied inverters, and the 150 C maximum operating temperature provides design margin for harsh environments. As with all Fuji Electric power modules, the datasheet mandates operation within absolute maximum ratings and the use of adequate fusing on the DC side to protect the device during panel or battery fault events.

🤖

Servo Amplifiers and Motion Control

Servo amplifiers driving high-torque AC motors use compact inverter stages where the 6MBI300U4-120's integrated 6-unit bridge simplifies power layout and maximizes power density. Machine-tool and robotics servo drives benefit from the module's low-inductance structure, which keeps turn-off transients controlled during rapid torque reversals and regenerative braking events that impose high current pulses on the bridge. The 300 A / 450 A rating envelope accommodates the peak overload currents typical of servo duty cycles, and the built-in thermistor allows the motion controller to implement accurate thermal models of the drive for maximum continuous torque extraction without overheating. Voltage-drive gating permits compact, high-channel-count driver boards suitable for amplifier form factors. Thermal design should follow the Fuji Electric datasheet mounting guidance to minimize case-to-heatsink resistance, since servo peak-to-continuous ratios concentrate losses in short high-current bursts repeated at high rate.

🖥️

Test and Power Supply Equipment

Programmable AC power sources, regenerative grid emulators, and high-power DC electronic loads frequently employ three-phase IGBT bridges such as the 6MBI300U4-120 as their output or energy-recovery stage. The module's 1200 V rating supports emulation of 400 V-class three-phase grids with adequate margin, and its 300 A rating with 450 A peak covers transient overload profiles that test equipment must source or sink. The integrated thermistor gives instrument controllers a direct thermal health signal for predictive protection during long automated test sequences. The low-inductance package supports the fast switching edges required for high-bandwidth waveform synthesis at the output, while voltage-drive gating simplifies multi-channel driver designs used in four-leg and three-level converter topologies derived from the standard bridge. Adhering to the datasheet's absolute maximum rating and fusing requirements is essential because test equipment deliberately stresses outputs across wide operating envelopes.

What are the key specifications of 6MBI300U4-120 that engineers should know?
The 6MBI300U4-120 is a Fuji Electric U-series IGBT module rated 1200 V collector-emitter voltage and 300 A with a 450 A absolute maximum collector current. It is a 6-in-one package implementing a three-phase inverter bridge, with 29 terminals, a built-in thermistor for heatsink temperature sensing, high-speed voltage-drive switching, and a low-inductance structure. Maximum operating temperature is 150 C. According to the Fuji Electric datasheet, users must operate within absolute maximum ratings and connect an adequate fuse or circuit protector.
What is the voltage and current rating of the 6MBI300U4-120 IGBT module?
The 6MBI300U4-120 is rated at 1200 V collector-emitter voltage and 300 A collector current, with an absolute maximum collector current of 450 A per the Fuji Electric datasheet. This 1200 V / 300 A class makes it suitable for three-phase inverter stages operating from industrial DC buses. The 450 A peak value is an absolute maximum, so continuous design currents must include margin for junction temperature, switching frequency, and cooling conditions.
What is the difference between 6MBI300U4-120 and 6MBI300U-120?
Both are Fuji Electric 1200 V / 300 A 6-in-one U-series modules, but the 6MBI300U4-120 is the U4-series variant that adds a built-in thermistor for temperature sensing, whereas the 6MBI300U-120 datasheet highlights high-speed switching, voltage drive, and low-inductance structure without indicating thermistor integration. Pinout and rating families are closely aligned, but the thermistor terminals differ, so always verify terminal assignment against both datasheets before substituting one for the other.
What is the best drop-in replacement for 6MBI300U4-120?
The closest drop-in replacement is the 6MBI300U4-120-01, a Fuji Electric suffix variant of the same 6MBI300U4-120 base module, sharing the same 1200 V / 300 A rating and package construction. The 6MBI300U4-120-50 is another suffix variant of the same model offered by distributors. Cross-brand drop-in equivalents require verification of pinout and package mounting because third-party cross-references could not be confirmed for this module; always validate terminal layout and thermistor connections before substitution.
Is 6MBI300U4-120 suitable for variable frequency drive (VFD) applications?
Yes, the 6MBI300U4-120 is well suited to VFD applications because its 6-in-one package implements a complete three-phase inverter bridge rated 1200 V and 300 A. The low-inductance module structure reduces turn-off voltage overshoot during PWM switching, the built-in thermistor enables heatsink over-temperature protection, and high-speed voltage-drive switching supports standard IGBT gate drivers. Industrial motor drives in the tens-of-kilowatts class are among the primary applications for this module family per Fuji Electric product positioning.
How do I download the 6MBI300U4-120 datasheet PDF?
The official 6MBI300U4-120 datasheet PDF is available from Fuji Electric at fuji-semiconductor.com/datasheet/fuji-semiconductor/6MBI300U4-120.pdf. The document is 14 pages and covers the outline drawing, equivalent circuit, thermistor characteristics, ratings, and application precautions, including the requirement to connect an adequate fuse or protector. Mirror copies exist on Alldatasheet (14 pages) and Datasheet4u, but the manufacturer URL is the authoritative source for the latest revision.
What is the price of 6MBI300U4-120 and where can I buy it?
The 6MBI300U4-120 is typically sold on a quote basis through industrial distributors such as USComponent, Adatronix, Jotrin, and Veswin, and Octopart lists pricing from 1 distributor. As of 2026-10-11, no standardized tier pricing is published by the sources reviewed, so request an RFQ from your distributor for volume pricing. Because supply status is reported as limited by market trackers, confirm stock and lead time before committing to a production schedule.
Is 6MBI300U4-120 in stock and what is the typical lead time?
Stock and lead time for the 6MBI300U4-120 vary by distributor: Octopart reports pricing availability from only 1 distributor, and market data characterizes supply and demand status as limited, which typically indicates long lead times. As of 2026-10-11, request current stock and lead time directly from Fuji Electric distributors such as USComponent, Adatronix, Jotrin, or Veswin. For production programs, qualify the 6MBI300U4-120-01 variant as a second source to mitigate allocation risk.
6MBI300U4-120 vs 6MBI450U4-120 - which should I choose?
Choose based on your inverter output current: the 6MBI300U4-120 is rated 300 A (450 A absolute maximum) while the 6MBI450U4-120 is a higher-current 450 A class device in the same U4 family, better for higher-power drives. If your worst-case RMS phase current including overload stays comfortably below 300 A with adequate cooling, the 300 A module costs less and dissipates less at lighter loads. Verify package mechanical compatibility, since the 450 A variant may use a larger case. Always check the Fuji Electric cross-reference tool for package details.
What is the best cross-brand equivalent for the Fuji Electric 6MBI300U4-120?
No cross-brand drop-in equivalent for the 6MBI300U4-120 could be confirmed from the reviewed web sources: generic cross-reference tools (DigiKey, PartLocator, PartGenie) exist but no verified pin-compatible competitor module was documented for this 1200 V / 300 A 6-unit package. Fuji Electric itself provides an IGBT module cross-reference search for competitor part numbers. For safety-critical power modules, we recommend using the official cross-reference tool and validating pinout, mounting holes, isolation, and thermistor terminals on the mechanical drawing before any cross-brand substitution.
What is the maximum operating temperature of 6MBI300U4-120?
The maximum operating temperature of the 6MBI300U4-120 is 150 C according to distributor-verified datasheet data (Datasheet4u lists Max Operating Temp: 150 C). This is the maximum junction temperature class for the IGBT dies; real designs must derate well below this limit based on switching frequency, load current, and heatsink performance. Use the built-in thermistor to monitor heatsink temperature and implement protection thresholds that keep junction temperature inside the safe operating area under all load and fault conditions.
How many terminals does the 6MBI300U4-120 module have and what are they for?
The 6MBI300U4-120 has 29 terminals per its datasheet summary. These comprise the three-phase bridge connections (DC bus terminals and AC output terminals), the six IGBT gate and emitter control terminals, the thermistor terminals for temperature sensing, and structural/auxiliary pins defined in the outline drawing on page 3 of the Fuji Electric datasheet. Because power module terminal maps are not standardized across families, always consult the official outline drawing and equivalent circuit sections before designing the mating busbar and gate-driver harness.
What gate driver requirements does the 6MBI300U4-120 have?
The 6MBI300U4-120 uses voltage-drive IGBT gating, so it works with standard optical or magnetic gate drivers providing positive gate voltage for turn-on and negative bias for turn-off robustness. Each of the six IGBT switches needs an isolated gate drive channel with appropriate peak gate current for the target switching speed, plus desaturation/overcurrent detection. Choose driver circuits with sufficient isolation (1200 V-class bus) and short gate loop inductance; Fuji Electric datasheets typically provide recommended gate resistance ranges - consult the application sections of the official datasheet for exact values.
Is 6MBI300U4-120 the same as 6MBI300U4-120-01?
The 6MBI300U4-120-01 is a suffix variant of the same base 6MBI300U4-120 module from Fuji Electric, sharing the 1200 V / 300 A rating, 6-in-one bridge configuration, and package construction. Suffixes on Fuji power modules typically denote manufacturing revision, packing, or special specification differences rather than a different electrical design. Distributors such as Adatronix and Veswin list them as related but separately orderable part numbers. Confirm the suffix meaning with Fuji Electric or the distributor if your qualification process requires exact part-number matching.
Is 6MBI300U4-120 RoHS compliant and lead-free?
The RoHS and lead-free status of the 6MBI300U4-120 could not be confirmed from the web sources reviewed for this page; the datasheet snippet retrieved does not state compliance information. Fuji Electric publishes RoHS and halogen status per product series on its official semiconductor website, so check the product page at fujielectric.co.jp or request a compliance certificate from your distributor before export-regulated designs. Do not assume compliance for older U-series power modules, as solder plating schemes have changed across production generations.

Engineering reference data for 6MBI300U4-120 — comparison, design guidance, and compliance information.

Selection Guide

Choose the 6MBI300U4-120 when you need a complete 1200 V / 300 A three-phase inverter bridge with integrated thermistor sensing for drives, UPS, welding, or renewable conversion in the tens-of-kilowatts class. Choose the 6MBI300U4-120-01 or -50 suffix variants when qualifying alternates for the same design, since they share the base module construction. Choose the 6MBI300U-120 only if your design has external temperature sensing and you can accept the absence of the built-in thermistor. Step up to the 6MBI450U4-120 or 6MBI600U4-120 when overload analysis shows your continuous or peak current exceeds the 300 A / 450 A envelope, accepting larger size and cooling requirements. There is no verified cross-brand drop-in; for competitor options, use Fuji Electric's official cross-reference tool and validate mechanical and terminal compatibility on drawings before qualifying any substitute.

Comparison with Alternatives

Parameter This Product 6MBI300U4-120-01 6MBI300U4-120-50 6MBI300U-120 6MBI450U4-120 6MBI600U4-120
Package 6-in-one IGBT module (U4) 6-in-one U4 - same 6-in-one U4 - same 6-in-one U - same family 6-in-one U4 - same family 6-in-one U4 - same family
Brand Fuji Electric Fuji Electric Fuji Electric Fuji Electric Fuji Electric Fuji Electric
Collector-Emitter Voltage 1.2 kV 1.2 kV 1.2 kV 1.2 kV 1.2 kV 1.2 kV
Collector Current Rating 300 A (450 A abs max) 300 A 300 A 300 A 450 A class 600 A class
Configuration 6-in-one (three-phase bridge) 6-in-one 6-in-one 6-in-one 6-in-one 6-in-one

Key Differentiators

  • Integrated thermistor temperature sensing (vs 6MBI300U-120)
  • Low-inductance module structure (vs 6MBI300U-120)
  • 450 A absolute maximum headroom over 300 A rating (vs 6MBI450U4-120)

Design Notes

Operate the 6MBI300U4-120 strictly within its absolute maximum ratings (1.2 kV, 450 A peak, 150 C maximum operating temperature) as emphasized in the Fuji Electric datasheet safety warnings. Connect an adequate semiconductor fuse or circuit protector on the DC link so that shoot-through or load faults are cleared before module destruction thresholds are reached. Size the fuse I2t below the module's withstand capability and coordinate with the 300 A continuous rating of the bridge.

Use the built-in thermistor to implement multi-level thermal protection: warn, derate, and trip thresholds tied to heatsink temperature rather than relying solely on calculated losses. Estimated: junction temperature rise equals total losses (conduction plus switching) multiplied by the case-to-heatsink and heatsink-to-ambient thermal resistances from the datasheet curves; verify your specific VCE(sat) and switching energy values against the official datasheet tables since these are operating-point dependent. Keep maximum junction temperature well below the 150 C limit for lifetime reliability.

Exploit the low-inductance module structure by keeping the DC-link capacitor loop as short and wide as possible: mount laminated busbars directly onto the module DC terminals and place snubber/decoupling capacitors adjacent to the P and N terminals. Gate-drive loops to each IGBT should be twisted-pair or closely coupled to minimize loop inductance. This reduces turn-off VCE overshoot during fast di/dt events and prevents exceeding the 1200 V rating during switching transients.

Do not confuse the U-series and U4-series variants when sourcing: the 6MBI300U-120 lacks the thermistor integration present in the 6MBI300U4-120, so a substitution without redesigning the temperature-sense circuit leaves the system without thermal feedback. Verify terminal assignments against the outline drawing (page 3 of the datasheet shows the outline drawing and equivalent circuit) before fabricating busbars or gate harnesses, since power module pinouts are not standardized across series.

Compliance Information

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

Compliance information was not stated in the retrieved web data or datasheet snippets. Request RoHS/REACH certificates from Fuji Electric or the distributor.

Data verified on: 2026-10-11 — data verified and curated by XAIPART's component engineering team

Related Searches

6MBI300U4-120 datasheet 6MBI300U4-120 datasheet PDF download Fuji Electric 6MBI300U4-120 IGBT module 1200V 300A IGBT module three phase bridge 6MBI300U4-120 price buy 6MBI300U4-120 equivalent substitute 6MBI300U4-120 vs 6MBI300U-120 difference 6MBI300U4-120 VFD inverter application 6MBI300U4-120 pinout terminal diagram Fuji Electric U4 series IGBT module 1200V what is the current rating of 6MBI300U4-120 6MBI300U4-120 drop-in replacement

Related Components & Terms

Fuji Electric 6MBI300U4-120 6MBI300U4-120-01 6MBI300U4-120-50 6MBI300U-120 6MBI450U4-120 6MBI600U4-120 IGBT Insulated Gate Bipolar Transistor IGBT module power semiconductor U-Series 6-in-one package three-phase inverter bridge VFD variable frequency drive thermistor freewheeling diode RoHS collector-emitter voltage safe operating area low-inductance module structure UPS inverter welding power supply renewable energy inverter
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered