ADS1259BIPW - 24-Bit 14.4 kSPS Delta-Sigma ADC | Texas Instruments
MPN: ADS1259BIPW ✓ 啟用中ADS1259BIPW 概覽
A delta-sigma ADC is a signal-conversion IC that uses oversampling and digital filtering to convert an analog input into a high-resolution digital value. It belongs to the data-converter IC hierarchy, which includes ADCs and DACs within semiconductor signal-chain and measurement systems. The ADS1259 is intended for sensors and industrial signals that require high resolution without the conversion speed of a SAR ADC.
The principal specifications are a 24-bit resolution, a maximum conversion rate of 14.4 kSPS, one analog input channel, and an SPI interface. Its integrated low-drift voltage reference improves measurement stability by reducing sensitivity to supply-voltage changes and temperature drift. These characteristics make the device suitable for industrial transmitters, pressure measurement, process monitoring, and precision sensor interfaces.
The converter uses a delta-sigma architecture to shape quantization noise and achieve high resolution from a narrow-band input. It can be paired with an external signal amplifier such as the PGA280 to create a high-accuracy measurement system. Its serial interface reduces the number of PCB connections compared with a parallel ADC, while the compact TSSOP package simplifies high-density instrument construction.
Typical applications include factory automation, process-control loops, industrial pressure transducers, laboratory instrumentation, and low-frequency sensor acquisition. The 14.4 kSPS rate captures changing process variables without requiring a very high-speed data-acquisition system. The integrated low-drift reference is especially useful when long-term measurement accuracy matters more than maximum throughput.
Designers should use the manufacturer pin-description and typical-application circuits when assigning signals and decoupling components. Input filtering, reference bypassing, grounding, and SPI clock implementation directly affect achievable noise performance. Confirm input range, gain settings, latency, and digital-filter behavior against the manufacturer datasheet before finalizing signal-chain calculations.
This product data combines the official device characteristics, ordering information, packaging details, replacement analysis, and application-specific engineering guidance. It also identifies where an exact drop-in replacement is available and where a functional substitute would require board-level verification.
直接替換替代品,適用於 ADS1259BIPW — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
ADS1259IPW
✅ 直接替換📋 參考替代品(不在目錄中)
ADS1259BIPW 最大額定值與電氣特性
| 解析度 | 24 bit |
| Maximum Conversion Rate | 14.4 kSPS |
| Input Channels | 1 channel |
| Analog Inputs | 1 input |
| ADC Architecture | Delta-sigma |
| Internal Reference | Low-drift voltage reference |
| Digital Interface | SPI |
| Application Class | Industrial |
| 封裝 | 20-pin TSSOP (PW) |
| 腳位數 | 20 pins |
| 工作溫度範圍 | -40°C to +105°C |
| 安裝類型 | Surface mount |
ADS1259BIPW 20-pin tssop (pw) 腳位配置指南
ADS1259BIPW(20-pin tssop (pw) 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: ADS1259BIPW.
請參閱 資料表 以查看完整腳位配置。
典型應用
ADS1259BIPW 適用於 6 應用s: Industrial Pressure Transmitters, Factory Process-Control Loops, Precision Test and Measurement Instruments, Industrial Sensor Acquisition, Low-Level Voltage Measurement, Automated Test Equipment.
Industrial Pressure Transmitters
The ADS1259BIPW fits industrial pressure transmitters that require a stable, high-resolution measurement from a low-level bridge or conditioned sensor signal. Its 24-bit conversion resolution and 14.4 kSPS maximum rate provide enough data density for pressure-loop monitoring without demanding the throughput of a fast SAR converter. The integrated low-drift reference helps preserve calibration performance as the equipment operates from -40°C to +105°C. Use the device after suitable excitation, amplification, filtering, and common-mode conditioning, and verify the applicable excitation and input limits in the manufacturer datasheet.
推薦
Factory Process-Control Loops
The ADS1259BIPW is appropriate for factory process-control loops that monitor temperature, pressure, flow, or level through relatively slow-moving analog signals. A 14.4 kSPS maximum conversion rate provides frequent updates for supervisory control, while 24-bit resolution preserves fine detail in sensor outputs. The single-channel delta-sigma architecture simplifies signal conditioning, and the low-drift reference reduces sensitivity to supply and environmental changes. In a production controller, the ADC can feed a microcontroller or PLC through SPI while keeping the analog front end isolated from high-energy drive stages.
推薦
Precision Test and Measurement Instruments
The ADS1259BIPW supports precision laboratory and bench instruments that must resolve small analog changes with a stable reference. Its 24-bit resolution is valuable for bridge sensors, strain-gauge signals, and low-level conditioned voltages, while the 14.4 kSPS rate supports responsive measurements without requiring a high-speed data-capture architecture. The low-drift internal reference improves reproducibility across operating conditions, and the SPI interface minimizes board area in compact instruments. Use careful analog grounding and filtering to realize the converter's intended noise performance.
推薦
Industrial Sensor Acquisition
The ADS1259BIPW is well suited to acquisition cards for resistive, voltage, and conditioned current sensors used in industrial equipment. Its single-channel input can monitor a selected bridge or transducer, and the 24-bit resolution can retain small process variations that would be difficult to distinguish with a lower-resolution converter. The 14.4 kSPS ceiling provides enough sampling density for supervisory diagnostics and control updates. Because the device is a delta-sigma ADC, system designers should account for digital filtering and conversion latency when timing control loops or comparing sampled data with events.
推薦
Low-Level Voltage Measurement
The ADS1259BIPW can digitize small conditioned voltages where amplitude resolution is more important than very high conversion speed. A 24-bit result creates 16,384 distinguishable digital-code levels, allowing a system to preserve fine changes in a measurement after suitable amplification and filtering. The low-drift reference supports stable readings in controlled industrial environments, and the 20-pin TSSOP package allows a compact analog measurement section. Confirm the converter's gain, input range, offset behavior, and noise specification in the manufacturer datasheet before choosing resistor values and amplifier scaling.
推薦
Automated Test Equipment
The ADS1259BIPW is useful in automated test equipment that evaluates slow analog parameters under controlled conditions. Its 14.4 kSPS maximum conversion rate supports practical test sequencing, while 24-bit resolution can reveal small deviations in outputs from sensors, references, and signal-conditioning networks. The SPI interface allows a test controller to configure acquisition and retrieve conversion results efficiently. A key design consideration is synchronization: account for digital-filter settling and conversion latency when defining measurement timing. Use the manufacturer's digital timing diagrams to establish command and data-capture sequences.
推薦
推薦產品摘要
工程參考資料,適用於 ADS1259BIPW — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ADS1259IPW |
|---|---|---|
| Package | 20-pin TSSOP (PW) | 20-pin TSSOP (PW) |
| Brand | Texas Instruments | Texas Instruments |
| Resolution | 24 bit | 24 bit |
| Maximum Conversion Rate | 14.4 kSPS | 14.4 kSPS |
| Input Channels | 1 channel | 1 channel |
| ADC Architecture | Delta-sigma | Delta-sigma |
| Digital Interface | SPI | SPI |
| Product Positioning | Advanced ADS1259 ordering option | Compact ADS1259 option for multiple installations |
主要差異化特點
- Direct same-family drop-in option (對比ADS1259IPW)
- Integrated low-drift reference (對比ADS1259IPW)
- Industrial environmental range (對比ADS1259IPW)
設計說明
Place the ADC input, reference, and decoupling connections according to the manufacturer typical-application layout. Keep sensitive analog traces short, route digital SPI signals away from input and reference nodes, and provide a quiet ground return for the converter. Decoupling capacitors should be placed directly at the associated power pins with short ground paths to reduce supply disturbance and preserve measurement repeatability.
Use the SPI interface according to the manufacturer timing diagrams and keep the serial clock, chip-select, reset, and data-ready routing compact and controlled. Account for the configured digital-filter settling time and conversion latency when initiating or capturing a conversion. If the analog input is slow-changing, synchronize control software with the data-ready indication rather than assuming that every SPI transaction represents a newly completed conversion.
Do not select amplifier gain or analog bias values without checking the ADC input range, common-mode limits, absolute maximum ratings, and selected PGA configuration. A 24-bit nominal resolution does not guarantee equivalent useful accuracy if the front end saturates, the source impedance is unsuitable, or reference and power arrangements violate the datasheet application requirements. Validate the complete analog path across temperature and expected sensor tolerance.
合規資訊