LTC1344CG - 6-Channel Software-Selectable Terminator | ADI
MPN: LTC1344CG ✓ ActiveLTC1344CG Overview
A cable terminator is an interface-circuit component that establishes the impedance expected by a communication standard at the receiving end of a cable. For differential links, termination reduces reflected signals and helps maintain reliable data transfer. Multi-protocol systems can require different termination arrangements as the physical interface changes, so a fixed resistor network may not be suitable. The LTC1344CG places six configurable terminators in one package, reducing the number of discrete networks required for multiprotocol equipment.
The manufacturer identifies six software-selectable multiprotocol cable terminators as the central feature of the LTC1344 family. Supported configurations include an RS-422 differential load, a V.35 T-network load, and an open state for transceivers incorporating their own termination. The power-off behavior is specifically useful because the terminator does not load the line when system power is absent. Exact control logic, supply limits, resistance values, and timing specifications should be taken from the manufacturer datasheet when designing the control interface.
In a typical multiprotocol port, the LTC1344CG is placed near the line connector so that the selected termination is presented at the cable interface. The open setting allows RS-232 or RS-423 transceivers with integrated termination to remain in circuit, while the V.11 and V.35 modes provide the corresponding load for other protocols. Keeping the termination network close to the connector can reduce the length of unterminated transmission line, although signal routing, grounding, and the transceiver manufacturer's recommendations remain important.
Typical uses include multiprotocol communications equipment, RS-232 port concentrators, V.35 network interfaces, and legacy data-communication systems where one connector must support several electrical standards. The LTC1344 can also be paired with the LTC1343 to form a complete software-selectable multiprotocol serial interface, as identified by the manufacturer product page. This pairing is particularly relevant when both transceiver selection and termination selection must be coordinated by the host.
The principal design consideration is control sequencing. Determine the required protocol state before enabling the interface, and ensure software cannot leave an inappropriate termination connected during reset or power transitions. Also verify the exact channel mapping, logic levels, supply requirements, and package dimensions against the manufacturer documentation before laying out a PCB or assigning control pins.
This product page organizes the confirmed LTC1344CG functions, protocol configurations, package information, sourcing paths, and application guidance for engineers evaluating multiprotocol cable termination. It also distinguishes the confirmed capabilities of the LTC1344 family from detailed electrical values that must be confirmed in the manufacturer datasheet before a production design is released.
Drop-in alternatives for LTC1344CG — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
LTC1344IG
✅ Drop-In📋 Reference alternative (not in catalog)
LTC1344CG#TRPBF
✅ Drop-In📋 Reference alternative (not in catalog)
LTC1344CG Specifications
| Product Type | Software-selectable cable terminator |
| Termination Channel Count | 6 channels |
| RS-422 Configuration | V.11, 100 ohm minimum differential load |
| V.35 Configuration | V.35 T-network load |
| Open-Configuration Protocol | RS-232 V.28 or RS-423 V.10 |
| Power-Off Line Loading | Line not loaded |
| Package | 24-pin SSOP |
| Pin Count | 24 pins |
| Mounting Type | Surface mount |
| Product Lifecycle | Production |
| REACH Status | [DATA_NEACHED: REACH compliance status] |
LTC1344CG 24-pin ssop Pin Configuration Guide
Pin configuration for LTC1344CG (24-pin ssop package). Pin numbering, functions, and connection diagrams are defined in the manufacturer datasheet. Refer to it for the exact footprint and soldering guidelines.
No detailed pinout data available for LTC1344CG.
Refer to the datasheet for full pin configuration.
Typical Applications
LTC1344CG is suitable for 6 applications: Multiprotocol Communications Port, RS-422 Differential Interface, V.35 Network Interface, Legacy RS-232 Port Sharing, Data-Circuit Concentrator, Instrumentation Communication Interface.
Multiprotocol Communications Port
The LTC1344CG fits a communications port that must support more than one cable termination standard under software control. Its six channels can be assigned to an RS-422 V.11 100-ohm-minimum differential load, a V.35 T-network load, or an open state for a self-terminated RS-232 or RS-423 transceiver. Placing the termination device near the connector limits unterminated line length and replaces several switched resistor networks. The system should assert the correct channel state before enabling the associated transceiver and should protect the interface against the voltage and surge conditions expected on the physical line.
Recommended
RS-422 Differential Interface
The LTC1344CG can present the confirmed RS-422 V.11 minimum 100-ohm differential load on any of its six independently selectable termination channels. This arrangement is useful in balanced data links where the receiver must see the specified source impedance to suppress reflections and maintain signal integrity. Configure the required channel with the interface-control logic and place the device close to the line entry point. Verify the exact termination value, control polarity, supply requirements, and channel mapping in the manufacturer documentation before releasing the PCB.
Recommended
V.35 Network Interface
The LTC1344CG supports a V.35 T-network load, making it suitable for legacy and specialized high-speed data links that require the correct balanced termination at the line interface. Its software-selectable implementation allows the termination arrangement to change with the selected operating mode rather than remaining permanently wired. A design should keep the V.35 network close to the connector, maintain controlled return paths, and verify the receiver and driver characteristics in their respective datasheets. The LTC1344CG manages termination but does not replace the active transceiver or provide protocol conversion.
Recommended
Legacy RS-232 Port Sharing
The open configuration of the LTC1344CG allows an RS-232 V.28 transceiver that provides its own termination to remain connected without adding an unnecessary external load. This is useful in shared or multiprotocol interface assemblies where the same connector must serve RS-232 and balanced protocols. Software can leave the termination channel open or select another termination mode as the operating standard changes. The design must coordinate the transceiver enable state and termination state to prevent mismatched configurations during startup, reset, or mode transitions.
Recommended
Data-Circuit Concentrator
A data-circuit concentrator can use the six termination channels of the LTC1344CG to serve multiple physical interfaces without duplicating a separate termination network at every connector. Each channel may be programmed for a confirmed RS-422 differential load, a V.35 T-network load, or the open condition used with self-terminated transceivers. Concentrator designs benefit from centralized protocol-state coordination because the host can select the termination together with the active transceiver. The PCB should group each termination channel with its associated connector routing and preserve controlled impedance on the balanced lines.
Recommended
Instrumentation Communication Interface
The LTC1344CG is suitable for test and measurement equipment that must connect older RS-232 or RS-423 equipment alongside differential or V.35 interfaces. Software-selectable termination allows the instrument to present the correct electrical condition for the selected external device instead of requiring the user to change hardware. The open state supports transceivers with integrated termination, while the other channels cover the confirmed RS-422 and V.35 arrangements. Designers should account for instrument grounding, cable transients, connector retention, and protocol-specific enable sequencing when integrating the terminator.
Recommended
Recommended Products Summary
Engineering reference data for LTC1344CG — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product |
|---|---|
| Product Type | Software-selectable cable terminator |
| Brand | Analog Devices |
| Package | 24-pin SSOP |
| Termination Channel Count | 6 channels |
| RS-422 Configuration | V.11, 100 ohm minimum differential load |
| V.35 Configuration | V.35 T-network load |
| Open Configuration | For RS-232 V.28 or RS-423 V.10 transceivers with integrated termination |
| Power-Off Line Loading | Line not loaded |
| Lifecycle Status | Production |
Key Differentiators
- Multiple protocol termination modes in one package (vs Fixed resistor termination network)
- Software control of the line termination (vs Mechanical or fixed-select termination network)
- Defined power-off line behavior (vs Conventional always-connected resistor termination)
Design Notes
Place the LTC1344CG close to the communication connector and connect each termination channel directly to its assigned line conductors. Minimize stubs between the package pins, protection devices, and connector so the configured impedance remains effective at the line interface. Keep the termination network on the cable side of any series switching elements, and use a continuous ground reference beneath the termination area. Confirm the official 24-pin package drawing and terminal assignments before creating the PCB footprint or routing protected line signals.
Do not assume the open configuration disables the entire interface. It only allows a connected RS-232 or RS-423 transceiver that provides its own termination to operate without an additional LTC1344 termination load. Coordinate the transceiver enable and termination-control states during startup, reset, and protocol changes. Conflicting states can leave the line incorrectly terminated or expose the interface to an unintended operating condition. Record valid state combinations in firmware and verify them against the manufacturer control-logic and timing information.
For balanced RS-422 or V.35 links, preserve the intended signal-to-ground geometry and keep the termination reference path continuous through the connector region. Avoid adding long branches to the six termination channels, because those branches act as unwanted stubs and can impair edge behavior. If protection components are required, place them consistently and evaluate their capacitance and leakage against the line standard. Signal-integrity verification must include the transceiver, cable, connector, and board stack-up because the LTC1344CG provides termination rather than equalization or active signal conditioning.
Compliance Information
The accessible manufacturer product information confirms the LTC1344 family is in production and identifies the LTC1344CG as a 24-pin SSOP cable terminator. Specific environmental, lead-free, halogen-free, and conflict-minerals declarations require confirmation from the manufacturer product page or material declaration.