Analog Devices

LTC1344CG - 6-Channel Software-Selectable Terminator | ADI

Артикул: LTC1344CG ✓ Активен
24-pin SSOP Package
MOQ: 1 |

LTC1344CG Обзор

The Analog Devices LTC1344CG is a software-selectable cable terminator containing six independently configurable terminator channels in a 24-pin SSOP package. Each channel can be configured for an RS-422 V.11 load of 100 ohms minimum, a V.35 T-network load, or an open circuit for RS-232 V.28 and RS-423 V.10 transceivers that provide their own termination. The device also avoids loading the line with power off.

A cable terminator is an interface-circuit component that establishes the impedance expected by a communication standard at the receiving end of a cable. For differential links, termination reduces reflected signals and helps maintain reliable data transfer. Multi-protocol systems can require different termination arrangements as the physical interface changes, so a fixed resistor network may not be suitable. The LTC1344CG places six configurable terminators in one package, reducing the number of discrete networks required for multiprotocol equipment.

The manufacturer identifies six software-selectable multiprotocol cable terminators as the central feature of the LTC1344 family. Supported configurations include an RS-422 differential load, a V.35 T-network load, and an open state for transceivers incorporating their own termination. The power-off behavior is specifically useful because the terminator does not load the line when system power is absent. Exact control logic, supply limits, resistance values, and timing specifications should be taken from the manufacturer datasheet when designing the control interface.

In a typical multiprotocol port, the LTC1344CG is placed near the line connector so that the selected termination is presented at the cable interface. The open setting allows RS-232 or RS-423 transceivers with integrated termination to remain in circuit, while the V.11 and V.35 modes provide the corresponding load for other protocols. Keeping the termination network close to the connector can reduce the length of unterminated transmission line, although signal routing, grounding, and the transceiver manufacturer's recommendations remain important.

Typical uses include multiprotocol communications equipment, RS-232 port concentrators, V.35 network interfaces, and legacy data-communication systems where one connector must support several electrical standards. The LTC1344 can also be paired with the LTC1343 to form a complete software-selectable multiprotocol serial interface, as identified by the manufacturer product page. This pairing is particularly relevant when both transceiver selection and termination selection must be coordinated by the host.

The principal design consideration is control sequencing. Determine the required protocol state before enabling the interface, and ensure software cannot leave an inappropriate termination connected during reset or power transitions. Also verify the exact channel mapping, logic levels, supply requirements, and package dimensions against the manufacturer documentation before laying out a PCB or assigning control pins.

This product page organizes the confirmed LTC1344CG functions, protocol configurations, package information, sourcing paths, and application guidance for engineers evaluating multiprotocol cable termination. It also distinguishes the confirmed capabilities of the LTC1344 family from detailed electrical values that must be confirmed in the manufacturer datasheet before a production design is released.

Аналоги без доработки для LTC1344CG — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

LTC1344IG

✅ Прямая замена
📦 SSOP-24
Same 24-pin SSOP and six-channel terminator function; suffix differs by lead-finish code, with 0% change in the documented package pin count

📋 Справочный аналог (нет в каталоге)

LTC1344CG#TRPBF

✅ Прямая замена
📦 SSOP-24
Same 24-pin SSOP and six-channel terminator function; lead-free suffix identifies the qualification and termination finish, with 0% change in package pin count

📋 Справочный аналог (нет в каталоге)

LTC1344CG Характеристики

Product Type Software-selectable cable terminator
Termination Channel Count 6 channels
RS-422 Configuration V.11, 100 ohm minimum differential load
V.35 Configuration V.35 T-network load
Open-Configuration Protocol RS-232 V.28 or RS-423 V.10
Power-Off Line Loading Line not loaded
Корпус 24-pin SSOP
Число выводов 24 pins
Тип монтажа Surface mount
Product Lifecycle Production
REACH Status [DATA_NEACHED: REACH compliance status]

Руководство по цоколевке LTC1344CG в корпусе 24-pin ssop

Цоколевка для LTC1344CG (корпус 24-pin ssop). Нумерация выводов, функции и схемы подключения определены в техническом описании производителя. Обратитесь к нему для точного посадочного места и рекомендаций по пайке.

Схема цоколевки корпуса 24-pin ssop для LTC1344CG

Нет подробных данных о распиновке для LTC1344CG.

Обратитесь к даташиту для полной конфигурации выводов.

Типичное применение

LTC1344CG подходит для 6 применениеs: Multiprotocol Communications Port, RS-422 Differential Interface, V.35 Network Interface, Legacy RS-232 Port Sharing, Data-Circuit Concentrator, Instrumentation Communication Interface.

🌐

Multiprotocol Communications Port

The LTC1344CG fits a communications port that must support more than one cable termination standard under software control. Its six channels can be assigned to an RS-422 V.11 100-ohm-minimum differential load, a V.35 T-network load, or an open state for a self-terminated RS-232 or RS-423 transceiver. Placing the termination device near the connector limits unterminated line length and replaces several switched resistor networks. The system should assert the correct channel state before enabling the associated transceiver and should protect the interface against the voltage and surge conditions expected on the physical line.

🌐

RS-422 Differential Interface

The LTC1344CG can present the confirmed RS-422 V.11 minimum 100-ohm differential load on any of its six independently selectable termination channels. This arrangement is useful in balanced data links where the receiver must see the specified source impedance to suppress reflections and maintain signal integrity. Configure the required channel with the interface-control logic and place the device close to the line entry point. Verify the exact termination value, control polarity, supply requirements, and channel mapping in the manufacturer documentation before releasing the PCB.

🖥️

V.35 Network Interface

The LTC1344CG supports a V.35 T-network load, making it suitable for legacy and specialized high-speed data links that require the correct balanced termination at the line interface. Its software-selectable implementation allows the termination arrangement to change with the selected operating mode rather than remaining permanently wired. A design should keep the V.35 network close to the connector, maintain controlled return paths, and verify the receiver and driver characteristics in their respective datasheets. The LTC1344CG manages termination but does not replace the active transceiver or provide protocol conversion.

🔧

Legacy RS-232 Port Sharing

The open configuration of the LTC1344CG allows an RS-232 V.28 transceiver that provides its own termination to remain connected without adding an unnecessary external load. This is useful in shared or multiprotocol interface assemblies where the same connector must serve RS-232 and balanced protocols. Software can leave the termination channel open or select another termination mode as the operating standard changes. The design must coordinate the transceiver enable state and termination state to prevent mismatched configurations during startup, reset, or mode transitions.

🖥️

Data-Circuit Concentrator

A data-circuit concentrator can use the six termination channels of the LTC1344CG to serve multiple physical interfaces without duplicating a separate termination network at every connector. Each channel may be programmed for a confirmed RS-422 differential load, a V.35 T-network load, or the open condition used with self-terminated transceivers. Concentrator designs benefit from centralized protocol-state coordination because the host can select the termination together with the active transceiver. The PCB should group each termination channel with its associated connector routing and preserve controlled impedance on the balanced lines.

🔧

Instrumentation Communication Interface

The LTC1344CG is suitable for test and measurement equipment that must connect older RS-232 or RS-423 equipment alongside differential or V.35 interfaces. Software-selectable termination allows the instrument to present the correct electrical condition for the selected external device instead of requiring the user to change hardware. The open state supports transceivers with integrated termination, while the other channels cover the confirmed RS-422 and V.35 arrangements. Designers should account for instrument grounding, cable transients, connector retention, and protocol-specific enable sequencing when integrating the terminator.

Сводка рекомендуемых товаров

LTC1343 Multiprotocol serial-interface transceiver intended for use with the LTC1344 Используется в: Multiprotocol Communications Port, RS-422 Differential Interface, V.35 Network Interface, Data-Circuit Concentrator, Instrumentation Communication Interface MC1489NE4 Texas Instruments Используется в: Multiprotocol Communications Port, RS-422 Differential Interface, Legacy RS-232 Port Sharing, Instrumentation Communication Interface MC1488NE4 Texas Instruments Используется в: V.35 Network Interface, Legacy RS-232 Port Sharing MC74F243M onsemi Используется в: Data-Circuit Concentrator
What is the LTC1344CG used for?
The LTC1344CG is a software-selectable cable terminator that provides six configurable termination channels for multiprotocol communications equipment. According to the Analog Devices product page, each channel can be configured as an RS-422 V.11 100-ohm-minimum differential load, a V.35 T-network load, or an open circuit for RS-232 V.28 and RS-423 V.10 transceivers that supply their own termination. It is intended for equipment that must support more than one communications standard without requiring a separate discrete termination network for every protocol.
How many termination channels does the LTC1344CG provide?
The LTC1344CG provides six software-selectable cable termination channels. The manufacturer describes the part as a software-selectable multiprotocol terminator, with each channel independently assigned to an RS-422 V.11 differential load, a V.35 T-network load, or an open configuration. This six-channel arrangement lets one interface device support several termination requirements at the same time. Exact control-signal mapping and channel independence details should be confirmed in the manufacturer datasheet before assigning a specific termination to a physical connector.
Which protocols does the LTC1344CG support?
The LTC1344CG supports termination arrangements associated with RS-422 V.11, V.35, RS-232 V.28, and RS-423 V.10 interfaces. The confirmed configurations are a 100-ohm-minimum differential load for RS-422, a T-network load for V.35, and an open circuit when the connected RS-232 or RS-423 transceiver provides its own termination. These are termination functions rather than complete transceiver implementations, so a suitable line driver and receiver must still be used to form the active communications interface.
Does the LTC1344CG load the cable when power is off?
The LTC1344CG is designed not to load the line with power off. This behavior is identified as a feature of the LTC1344 by the manufacturer and is useful when a shared or multiprotocol line may carry signals while the termination circuit is unpowered. For system-level safety, also review the transient and power-up behavior of the connected transceiver because the absence of a powered termination load does not by itself determine the complete off-state pin voltage or fault tolerance.
What is the LTC1344CG pinout and package?
The LTC1344CG is packaged as a 24-pin SSOP, and the manufacturer identifies it as a surface-mount cable terminator. A complete numbered pinout is not published in the accessible product-page information, so use the pin-description table and package drawing in the manufacturer datasheet when assigning control inputs and connecting the six termination channels. Do not infer pin functions from the package outline alone. The package footprint should also be checked against the PCB library because exposed-pad and lead-style details must be confirmed from the official drawing.
Where can I download the LTC1344CG datasheet PDF?
The official LTC1344 documentation is available through the Analog Devices LTC1344 product page at https://www.analog.com/en/products/ltc1344.html. The page provides the manufacturer data sheet and product information for the LTC1344 family, including the LTC1344CG ordering code used for the 24-pin SSOP configuration. Use the manufacturer PDF as the controlling document for supply voltage, logic thresholds, resistance tolerances, temperature limits, pin names, and package dimensions. Third-party copies may be useful for searching, but they should not replace the official document for a released design.
Where can I buy the LTC1344CG and what is its price?
The LTC1344CG can be requested through the Request a Quote form on this product page, where the requested quantity, packaging, and delivery requirements can be reviewed with XAIPART. The manufacturer lists the LTC1344 family in production, while current commercial availability and the amount available for shipment should be confirmed through the quote process. Request a firm quotation rather than relying on a historical or family-level list price, because the price of the exact LTC1344CG ordering code can vary with quantity and market conditions.
What is the lead time for the LTC1344CG?
The current lead time for the LTC1344CG should be obtained through the Request a Quote form on this page. The manufacturer identifies the LTC1344 family as production, which confirms current product status, but it does not establish a fixed lot-level delivery period. When requesting a quotation, state the required quantity, date code, approved shipping destination, and whether reel, tray, or another permitted delivery format is required. These details allow the supplier to confirm the most accurate schedule instead of quoting a generic family lead time.
Is the LTC1344CG in stock?
Current stock for the exact LTC1344CG ordering code should be confirmed through the Request a Quote form on this page. The manufacturer lists the LTC1344 family in production, and distribution records show the part as a cataloged cable terminator, but neither fact alone guarantees immediately available inventory. Submit the required quantity and target date with the request. The fulfillment response can then distinguish components ready for shipment from material scheduled for production, testing, or replenishment.
What is the difference between the LTC1344CG and a fixed cable terminator?
The LTC1344CG consolidates six software-selectable terminator channels into one package, whereas a fixed cable terminator implements only one fixed impedance arrangement. The LTC1344 supports an RS-422 V.11 differential load, a V.35 T-network load, and an open setting for transceivers with integrated termination. This configurability is valuable in multiprotocol equipment because the host can select the appropriate line termination. The trade-off is added control logic and package complexity compared with a simple resistor-based terminator.
When should I choose the LTC1344CG instead of discrete termination resistors?
Choose the LTC1344CG when the same physical communication path may need to switch among RS-422, V.35, and open-termination states under software control. Six integrated channels reduce the component count and make coordinated protocol selection more practical than several independently switched resistor networks. For a fixed protocol and permanently connected cable, discrete resistors may remain simpler and less expensive. The integrated solution is most appropriate when protocol agility, channel count, and reliable control outweigh the additional package and control requirements.
Can the LTC1344CG work with the LTC1343?
Yes, the LTC1344 is intended to be paired with the LTC1343 to create a complete software-selectable multiprotocol serial interface. The manufacturer identifies this combination as the intended architecture when both transceiver and termination behavior must be selected by software. In such a design, the LTC1343 handles the active line interface while the LTC1344 supplies the configurable cable termination. Check signal timing, control polarity, supply requirements, and interface states against both manufacturer datasheets before finalizing the system.
What is the best drop-in replacement for the LTC1344CG?
No verified pin-to-pin drop-in replacement for the LTC1344CG is identified in the available cross-reference results. The cross-reference sources are general component-search tools rather than manufacturer-confirmed equivalents, so they do not establish identical SSOP-24 pin assignments, protocol configurations, or electrical performance. Do not substitute a similarly named cable-terminator device solely by function or package count. Any proposed replacement must be checked against the official pin-description table, supported termination modes, control logic, supply requirements, and timing behavior.
Is there an RS-232 or RS-422 transceiver equivalent to the LTC1344CG?
The LTC1344CG is not a complete RS-232 or RS-422 transceiver; it is a passive, software-selectable termination device. An equivalent functional solution would need to preserve six configurable termination channels, the specified RS-422 and V.35 loads, the open state for self-terminated transceivers, the power-off line behavior, and the 24-pin SSOP control interface. No manufacturer-confirmed equivalent meeting those requirements is established here. A transceiver may be used alongside the LTC1344CG, but it is not automatically a drop-in substitute.
How should the LTC1344CG be laid out next to a communications connector?
Place the LTC1344CG close to the connector-side termination point and route the relevant differential or network conductors to the appropriate termination pins with minimal stub length. Keep the termination network on the line side of any series protection components so switching and protection devices do not interrupt the termination path. Maintain a continuous ground reference, observe the connector's signal-to-ground spacing, and confirm lead assignments from the official package drawing. Signal-integrity performance also depends on the transceiver, cable impedance, connector, and board stack-up.
What key specifications should engineers verify before using the LTC1344CG?
Engineers should verify the supply-voltage range, control-input thresholds, termination resistance, tolerance, temperature range, timing, and exact 24-pin assignments in the manufacturer datasheet. The confirmed headline characteristics are six software-selectable termination channels, an RS-422 V.11 100-ohm-minimum differential load, a V.35 T-network load, an open configuration for self-terminated RS-232 and RS-423 transceivers, and no line loading with power off. These confirmed functions make the device suitable for multiprotocol interfaces, while the remaining electrical details determine final board-level qualification.

Справочные инженерные данные для LTC1344CG — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose the LTC1344CG when a communications port must support several termination standards and the host can control the interface state in software. Its six channels cover the confirmed RS-422 V.11 differential load, V.35 T-network load, and open condition for self-terminated RS-232 or RS-423 transceivers, making it useful for concentrated multiprotocol equipment. Use discrete resistors instead when the protocol is permanently fixed, the channel count is low, and simpler control or lower component complexity matters more. The LTC1344CG is not a transceiver and should be paired with an appropriate active line interface, including the LTC1343 for the manufacturer-described multiprotocol architecture. No verified drop-in replacement is established, so any substitute must be checked for identical pin assignments, termination values, control polarity, power requirements, and power-off behavior rather than selected only by package type.

Сравнение с аналогами

Параметр Этот товар
Product Type Software-selectable cable terminator
Brand Analog Devices
Package 24-pin SSOP
Termination Channel Count 6 channels
RS-422 Configuration V.11, 100 ohm minimum differential load
V.35 Configuration V.35 T-network load
Open Configuration For RS-232 V.28 or RS-423 V.10 transceivers with integrated termination
Power-Off Line Loading Line not loaded
Lifecycle Status Production

Ключевые отличия

  • Multiple protocol termination modes in one package (против Fixed resistor termination network)
  • Software control of the line termination (против Mechanical or fixed-select termination network)
  • Defined power-off line behavior (против Conventional always-connected resistor termination)

Заметки по проектированию

Place the LTC1344CG close to the communication connector and connect each termination channel directly to its assigned line conductors. Minimize stubs between the package pins, protection devices, and connector so the configured impedance remains effective at the line interface. Keep the termination network on the cable side of any series switching elements, and use a continuous ground reference beneath the termination area. Confirm the official 24-pin package drawing and terminal assignments before creating the PCB footprint or routing protected line signals.

Do not assume the open configuration disables the entire interface. It only allows a connected RS-232 or RS-423 transceiver that provides its own termination to operate without an additional LTC1344 termination load. Coordinate the transceiver enable and termination-control states during startup, reset, and protocol changes. Conflicting states can leave the line incorrectly terminated or expose the interface to an unintended operating condition. Record valid state combinations in firmware and verify them against the manufacturer control-logic and timing information.

For balanced RS-422 or V.35 links, preserve the intended signal-to-ground geometry and keep the termination reference path continuous through the connector region. Avoid adding long branches to the six termination channels, because those branches act as unwanted stubs and can impair edge behavior. If protection components are required, place them consistently and evaluate their capacitance and leakage against the line standard. Signal-integrity verification must include the transceiver, cable, connector, and board stack-up because the LTC1344CG provides termination rather than equalization or active signal conditioning.

Информация о соответствии

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Без свинца
Unknown
Без галогенов
Unknown
Конфликтные минералы
Unknown

The accessible manufacturer product information confirms the LTC1344 family is in production and identifies the LTC1344CG as a 24-pin SSOP cable terminator. Specific environmental, lead-free, halogen-free, and conflict-minerals declarations require confirmation from the manufacturer product page or material declaration.

Данные проверены: 2026-11-09 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

LTC1344CG datasheet LTC1344CG pinout LTC1344CG datasheet pdf LTC1344CG equivalent LTC1344CG replacement LTC1344CG cross reference LTC1344CG SSOP-24 LTC1344CG software selectable terminator LTC1344CG RS-422 V.35 termination LTC1344CG price LTC1344CG stock Analog Devices LTC1344CG

Связанные компоненты & термины

Analog Devices LTC1344CG LTC1344 LTC1343 software-selectable cable terminator multiprotocol terminator interface IC semiconductor RS-422 V.11 RS-232 V.28 RS-423 V.10 V.35 T-network load differential load 100 ohm minimum differential load SSOP-24 SSOP family surface-mount technology line termination signal integrity communications interface
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ