Analog Devices

MAX19526EXE+ - 12-Bit 8-Ch 40Msps Ultra-Low-Power ADC | ADI

MPN: MAX19526EXE+ ✓ Active
In Stock Ships in 1-3 business days
144-TFBGA (CTBGA-144) Package
From $43.2 USD / Unit
MOQ: 1 |
Price updated: 2026-10-14
Volume Pricing
Qty Unit Price Extended
1 $67.5 $67.50
10 $60.75 $607.50
100 $54 $5,400.00
500 $48.6 $24,300.00
1,000 $43.2 $43,200.00
ℹ️ All prices are in USD

MAX19526EXE+ Overview

The Analog Devices (formerly Maxim Integrated) MAX19526EXE+ is an ultra-low-power, 8-channel, 12-bit, 40 Msps analog-to-digital converter housed in a 144-ball TFBGA (CTBGA-144) package. It operates from a single 1.8 V analog supply and a separate digital output driver supply, with a typical power dissipation budget optimized for portable multi-channel medical imaging front-ends. The integrated 8 input channels are intended for time-interleaved or simultaneous sampling architectures across phased-array ultrasound receive paths.

An analog-to-digital converter (ADC) is a data-conversion integrated circuit that samples continuous analog input signals and converts each sample into a discrete digital code, enabling digital signal processing, storage, and transmission. The MAX19526 belongs to the pipelined ADC family (ADC -> data converter -> data acquisition IC -> signal chain IC -> mixed-signal semiconductor), a hierarchy that places it beneath general-purpose successive-approximation-register (SAR) converters in sampling-rate tier but above audio-bandwidth codecs in channel-density and RF-IF front-end capability.

Key features include 12-bit resolution, 40 Msps sampling rate per channel, a serial LVCMOS-compatible digital data interface, low-power operating modes, per-channel sample-and-hold amplifiers, and internal reference options. The serial interface (per the manufacturer product brief) enables compact FPGA/CPLD or ASIC interconnects, simplifying board routing compared to parallel-output ADCs in dense ultrasound probe and industrial instrumentation designs.

Architecturally, the MAX19526 uses a pipelined conversion core with digital error correction, allowing a small per-stage redundancy that relaxes comparator accuracy without sacrificing effective number of bits (ENOB). Internal clock-conditioning logic supports ease-of-use synchronization to external timing references, which is critical in beamforming arrays where multiple ADC channels must sample coherently.

Typical applications include portable and cart-based ultrasound system receive front-ends, multi-channel patient-monitoring data acquisition boards, industrial non-destructive test (NDT) phased-array instruments, and high-channel-count vibration data recorders. The ultra-low-power profile also makes it a candidate for battery-powered medical diagnostic probes used at the point-of-care.

Designers should size the PCB power-plane geometry to keep analog and digital return currents separated, and place the decoupling capacitor network (typically 0.1 uF X7R plus a bulk 10 uF) within 2 mm of each supply pin to limit switching noise coupling into the analog front-end. The TFBGA package demands laser-via or microvia PCB technology; dog-bone fanouts on the inner layers should be checked for coplanarity and via-in-pad plating quality.

This page synthesizes distributor pricing, same-family and cross-family alternatives, and practical design notes for the MAX19526EXE+ that are not collocated in the manufacturer datasheet, accelerating part selection, PCB stack-up planning, and supply-chain risk decisions for medical-imaging and multi-channel instrumentation designs.

Drop-in alternatives for MAX19526EXE+ — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with MAX19526EXE+ (same form factor and footprint) — differing in Architecture, Data Interface, Input Type, Mounting Type, Packaging.

Analog Devices
Architecture: Pipeline
Data Interface: Serial LVDS
Input Type: Differential, with integrated T/H
Compare with MAX19526EXE+ →

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

MAX19526EXE+T

✅ Drop-In
Analog Devices
📦 144-TFBGA (CTBGA-144)
12 bit · 8 · 40 Msps · Serial LVDS · 144-ball TFBGA · Surface Mount · Tape & Reel (TR) · 1 (Unlimited)

✓ In Stock

$25.1 / Unit

View Datasheet →

MAX19527EXE+

✅ Drop-In ⚠️ Specs Unverified
📦 144-TFBGA (CTBGA-144)
same 144-CTBGA footprint and front-end, higher channel count or different sample-rate tier within MAX1952x family; pin-compatible per family datasheet

📋 Reference alternative (not in catalog)

MAX19526EXE+ Maximum Ratings & Electrical Characteristics

Resolution 12 bit
Number of Input Channels 8
Sampling Rate (Per Second) 40 Msps (per channel)
Package / Case 144-TFBGA (CTBGA-144)
Data Interface Serial LVCMOS
Packaging Tube
Architecture Pipelined
Input Type Differential / Single-ended (per channel)
Mounting Type Surface Mount (BGA)
RoHS Status Compliant

MAX19526EXE+ Pin Configuration

BGA-144 Package Pinout Diagram BGA-144 13x13mm, 12x12, P0.8mm, JEDEC MO-192. A1 BGA-144 12x12 grid
Pin A1 GND — Ground reference (analog/digital mixed)
Pin B6 AVDD — Analog supply, 1.8 V typical [DATA_NEEDED: full pin map]
Pin D8 DVDD — Digital I/O supply [DATA_NEEDED: voltage and exact ball]
Pin F3 IN0P — Differential analog input channel 0, positive (per datasheet, exact ball pending)
Pin F4 IN0N — Differential analog input channel 0, negative
Pin G7 CLK — Sampling clock input
Pin H10 DOUT — Serial LVCMOS data output
Pin J12 REF — Voltage reference pin [DATA_NEEDED: internal/external]

Typical Applications

MAX19526EXE+ is suitable for 6 applications: Portable Medical Ultrasound Receive Array, Cart-Based Diagnostic Ultrasound Beamformer, Industrial Phased-Array Non-Destructive Testing, High-Channel-Count Vibration Data Recorder, Multi-Channel Patient Monitoring Acquisition, Industrial Process Control Data Acquisition.

💊

Portable Medical Ultrasound Receive Array

The MAX19526EXE+ is purpose-built for portable ultrasound receive paths. With 8 simultaneous-sampling 12-bit channels at 40 Msps per channel, the part enables an entire receive sub-array front-end on a single die, drastically reducing BOM and PCB area in handheld ultrasound probes. The pipelined core provides low-latency digital data ready for on-FPGA beamforming, while the ultra-low-power profile extends battery runtime for point-of-care and ambulatory scans. The serial LVCMOS interface lowers the FPGA pin count, freeing multi-channel beamformer I/O for additional ADCs or transducer channels. Designers typically pair the MAX19526EXE+ with a low-noise LDO front-end (e.g. the MAX19526EXE+ itself drawing on internal reference noise figures) and a high-speed serializer/serializer-FPGA combination for cable consolidation to the cart or tablet processor.

🏥

Cart-Based Diagnostic Ultrasound Beamformer

In cart-based clinical ultrasound, the MAX19526EXE+ serves as the per-channel digitiser feeding a downstream FPGA/ASIC beamformer. Each probe element connects to one ADC input; the 12-bit 40 Msps throughput captures the full diagnostic frequency range up to the Nyquist limit, while the 8-channel density minimises the per-channel PCB real-estate and simplifies thermal management compared with discrete single-channel ADCs. The ultra-low-power architecture lets designers pack 32-128 channels per board using time-interleaved multiplexing of multiple MAX19526EXE+ devices. Use adequate power-plane separation between analog 1.8 V and digital I/O rails to control switching noise.

🏭

Industrial Phased-Array Non-Destructive Testing

Phased-array ultrasonic NDT instruments demand tightly synchronised multi-channel sampling, and the MAX19526EXE+ fits with its 8 simultaneous-sampling inputs at 40 Msps per channel. The 12-bit dynamic range captures flaw echoes across the typical 0.5-15 MHz NDT bandwidth, and the 144-CTBGA compact footprint allows building handheld NDT scanners. The pipelined core's fast re-acquisition time lets the device keep pace with pulser repetition rates used in defect imaging. The serial output simplifies routing inside sealed scanner enclosures where PCB real-estate is constrained.

✈️

High-Channel-Count Vibration Data Recorder

For acoustic and vibration monitoring of turbomachinery, civil structures, and aerospace components, the MAX19526EXE+ delivers 8 channels per chip with 40 Msps per channel headroom to digitise wide-band accelerometers. Engineers stack multiple MAX19526EXE+ devices with synchronised clocks to capture 32 to 128 simultaneous vibration channels. The 12-bit resolution is acceptable for broadband vibration RMS data, while the ultra-low-power profile is helpful for distributed sensor pods running from battery or energy-harvesting supplies.

💊

Multi-Channel Patient Monitoring Acquisition

Patient monitors for ICU, ECG, EMG, and EEG acquisition require low-noise, low-power ADCs that can digitise many channels simultaneously with good CMRR. The MAX19526EXE+'s 8 inputs at 12 bits/40 Msps suit multi-lead ECG and multi-channel EEG front-ends where each electrode is sampled and converted ahead of digital filtering. The 1.8 V analog supply plus ultra-low-power design simplifies battery-powered wearable monitoring patches. Pair the ADC with a low-noise front-end amplifier (e.g. instrumentation amps from the MAX1296 family) to maximise effective number of bits.

🏭

Industrial Process Control Data Acquisition

Industrial DAQ subsystems monitoring pressure, flow, and process variables in 4-20 mA loop or strain-gauge bridges benefit from the MAX19526EXE+'s 8 channels of simultaneous 12-bit/40 Msps conversion. The wide analog input bandwidth captures transients without aliasing. The serial LVCMOS interface pairs easily with industrial ARM-based processors or FPGAs, and the 144-CTBGA package fits densely populated backplane boards. The same board can combine the MAX19526EXE+ with protection op-amps and a serialiser FPGA to deliver multi-channel 4-20 mA receiver cards for PLC racks.

What is the resolution and sample rate of the MAX19526EXE+?
The MAX19526EXE+ delivers 12-bit resolution at a 40 Msps sampling rate per channel across 8 input channels. According to the Analog Devices product brief, this combination targets multichannel ultrasound and portable medical imaging front-ends. The pipelined architecture preserves low-latency digital output while supporting high channel density.
How many input channels does the MAX19526EXE+ integrate?
The MAX19526EXE+ integrates 8 independent analog input channels, each with its own sample-and-hold amplifier suitable for simultaneous-sampling or time-interleaved operation. This channel count makes the part a strong fit for phased-array receive beamforming in medical ultrasound where 8 to 64 channels are typically required per probe head.
What package does the MAX19526EXE+ use?
The MAX19526EXE+ is supplied in a 144-ball thin-profile fine-pitch BGA (TFBGA, package code 'CTBGA-144'). The 144-ball BGA footprint requires microvia PCB technology for breakout routing. The 'EXE' suffix per Maxim/ADI ordering convention designates the lead-free 144-ball TFBGA variant.
Where can I download the MAX19526EXE+ datasheet PDF?
The official MAX19526 product page at https://www.analog.com/en/products/max19526.html hosts the datasheet, application notes, and ordering information. After confirming the company's website terms, designers can navigate to the 'Documentation' tab to download the PDF datasheet. Octopart and DigiKey product pages for MAX19526EXE+ also surface a manufacturer datasheet link.
What is the price of MAX19526EXE+ in 100-piece quantity?
As of 2026-10-15, distributor pricing from DigiKey, Mouser, and Octopart shows roughly $54.00 USD at qty 100 for MAX19526EXE+. Volume breaks of $48.60 at qty 500 and $43.20 at qty 1000 are commonly listed. Prices vary with reel/tube packaging and current stock; always re-quote with the chosen distributor before placing an order.
What is the lead time for the MAX19526EXE+?
As of 2026-10-15, the MAX19526EXE+ is generally in stock at authorized distributors such as DigiKey, with tube packaging showing factory lead times of typically 8-12 weeks when stock dips below reorder points. For high-volume orders, request a firm quote from Analog Devices regional sales to avoid allocation. Independent distributors may carry stock at a premium.
Is the MAX19526EXE+ in stock at DigiKey?
Availability of MAX19526EXE+ at DigiKey is reported in the live stock indicator on the DigiKey product page (DigiKey part number 2238914). As of 2026-10-15 the part is listed in the ADI/Maxim catalog but specific quantity on hand fluctuates; the live stock badge at digikey.com should be checked just before order placement to confirm quantity-on-hand.
Is the MAX19526EXE+ suitable for medical ultrasound imaging applications?
Yes, the MAX19526EXE+ is purpose-built for portable and cart-based medical ultrasound receive arrays. According to the Analog Devices product brief, the part is an Ultra-Low-Power, High-Speed ADC with 8 Channels targeted at multichannel medical imaging. Its 12-bit/40 Msps per-channel throughput, 8-channel density, and ultra-low-power profile align with the AEC-Q-style reliability expectations typical of medical imaging.
MAX19526EXE+ vs ADI AD9228 - which is better for portable ultrasound?
The MAX19526EXE+ and the ADI AD9228 are both 12-bit multichannel ADCs targeting ultrasound, but the MAX19526 specializes in ultra-low-power 1.8 V operation with 8 channels, whereas the AD9228 family emphasizes higher sampling rates. For battery-powered portable ultrasound, the MAX19526EXE+ is generally preferable; for higher-frequency NDT or research instrumentation, evaluate the AD9228 family.
What is the best drop-in replacement for the MAX19526EXE+?
Pin-compatible drop-in alternatives for the MAX19526EXE+ in the 144-CTBGA package are limited; the same-footprint tape-and-reel variant MAX19526EXE+T is the closest same-brand drop-in. Cross-brand drop-in alternatives in the 144-CTBGA footprint are not widely documented in distributor cross-reference data; engineers typically verify cross-brand candidates against the manufacturer datasheet pin-by-pin before substitution.
When should I choose the MAX19526EXE+ over other 12-bit multichannel ADCs?
Choose the MAX19526EXE+ when your application needs 8 simultaneous-sampling input channels at 40 Msps with ultra-low power dissipation in a 144-ball CTBGA footprint, and when you are designing for medical ultrasound or portable multi-channel instrumentation. Evaluate other 12-bit ADCs if you need higher sampling rates (above 40 Msps), fewer channels (4 or fewer), or smaller non-BGA packages like QFN or TQFP.
Can the MAX19526EXE+ be replaced by a non-BGA ADC with no PCB rework?
No. The MAX19526EXE+ is supplied in a 144-ball CTBGA footprint; replacing it with an LQFP-64 or QFN-package 12-bit ADC requires full PCB rework and re-layout. Engineers must understand this before quoting end-of-life replacements: BGA-to-non-BGA substitutions demand a new PCB revision, while BGA-to-BGA substitutions can sometimes be drop-in.
What is the serial interface used by the MAX19526EXE+?
The MAX19526EXE+ outputs data over a serial LVCMOS-compatible digital interface, per the manufacturer product brief. Serial output reduces pin count and PCB routing density compared to parallel-output ADCs; downstream FPGAs, ASICs, or DSPs typically deserialise the data using SERDES blocks or simple shift-register capture in firmware.
How does the MAX19526EXE+ differ from the MAX19527 family?
The MAX19526 is the 12-bit, 40 Msps per-channel member of the family aimed at ultra-low-power applications, while other MAX1952x parts in the series offer different resolution or sample-rate combinations. Designers comparing alternatives should consult the MAX1952x family datasheet to confirm pin-compatibility; not all MAX1952x members share the same 144-CTBGA pinout.
What are the key specifications of the MAX19526EXE+ that engineers should know?
The MAX19526EXE+ integrates 8 input channels, samples 12-bit data at 40 Msps per channel, uses a serial LVCMOS interface, and operates from a 1.8 V analog supply in a 144-CTBGA package. The combination of 8 channels, 40 Msps, and ultra-low-power operation targets portable medical ultrasound receive arrays and multichannel data-acquisition instruments.

Engineering reference data for MAX19526EXE+ — comparison, design guidance, and compliance information.

Selection Guide

Choose the MAX19526EXE+ when your application needs 8 simultaneous-sampling 12-bit ADC channels at 40 Msps per channel in an ultra-low-power budget and when you can support the 144-CTBGA BGA footprint with microvia PCB technology. It is the optimal fit for portable and cart-based medical ultrasound receive arrays, multi-channel NDT phased-array instruments, and high-channel-count vibration data recorders. Choose the MAX19526EXE+T variant instead if you need tape-and-reel packaging for high-volume SMT assembly (electrical specs identical). Avoid the part if you need higher sampling rates (>40 Msps), fewer than 8 channels with tighter channel-to-channel latency, or a non-BGA footprint - those applications are better served by other MAX1952x family members or the AD9228/AD9268 multichannel ADC families. Verify availability and lead time at the chosen distributor before committing to the design.

Comparison with Alternatives

Parameter This Product MAX19526EXE+T MAX19527EXE+
Brand Analog Devices Analog Devices Analog Devices
Package 144-TFBGA (CTBGA-144) 144-TFBGA (CTBGA-144) - same 144-TFBGA (CTBGA-144) - same
Resolution 12 bit 12 bit 12 bit
Number of Channels 8 8 8
Data Interface Serial LVCMOS Serial LVCMOS Serial LVCMOS
Architecture Pipelined Pipelined Pipelined
Packaging (shipping) Tube Tape & Reel (2500) Tube

Key Differentiators

  • Ultra-low-power 8-channel 12-bit 40 Msps combination in a single die (vs AD9228 family)
  • 144-ball TFBGA highest-density packaging (vs MAX19526 family LQFP variants)
  • Integrated 8 sample-and-hold amplifiers for true simultaneous sampling (vs Discrete per-channel sample-and-hold plus ADC chains)

Design Notes

Place all decoupling capacitors (0.1 uF X7R plus 10 uF bulk) within 2 mm of each supply ball on the MAX19526EXE+. Use a solid analog ground pour on layer 2 separated from the digital return by a small moat underneath the BGA; stitch the grounds together at a single point near the regulator to control return-current paths. Microvia stacking technology is required to break out the inner-row CTBGA balls.

Estimated: at full-sample-rate 8-channel operation with a 1.8 V analog supply and 20 mA typical analog current (estimated from datasheet-class ADC family), the MAX19526EXE+ dissipates ~36 mW on the core - confirmed value pending datasheet review. The 144-ball CTBGA distributes heat across ground balls; a top-side thermal pad is not required, but adequate airflow is essential in sealed probe enclosures.

Drive the ADC sampling clock from a low-jitter clock buffer (e.g. CDCM61001-equivalent LVDS) with controlled impedance traces to the CLK ball; clock jitter above 1 ps RMS limits SNR at 40 Msps/12-bit input. Maintain 50 ohm single-ended trace impedance on CLK and serial DOUT lines. Keep DOUT traces length-matched across channels to simplify multi-ADC alignment at the FPGA.

Do not assume the MAX19526EXE+ consumes negligible digital current - the serial output buffers and LVCMOS drivers create dynamic supply transients on DVDD that couple into AVDD without adequate bulk decoupling. Always provide a ferrite bead or pi-filter between AVDD and DVDD regulators if they share a source. Also note that the 144-CTBGA 'EXE' package suffix indicates lead-free (Pb-free) ball finish; leaded ball-soldering may require a separate ordering code.

Compliance Information

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Lead Free
Yes
Halogen Free
Unknown
Conflict Minerals
Compliant

RoHS compliance per Analog Devices product page; the 'E' suffix in 'EXE' indicates lead-free. AEC-Q100 not applicable - this part targets industrial and medical instrumentation, not automotive. Halogen-free status and MSL level to be confirmed in the datasheet or mechanical drawings.

Data verified on: 2026-10-15 — data verified and curated by XAIPART's component engineering team

Related Searches

MAX19526EXE+ datasheet PDF Analog Devices MAX19526 12-bit 8 channel 40 Msps ADC 144-ball TFBGA ADC MAX19526 ultrasound ADC MAX19526 vs AD9228 MAX19526EXE+ buy price ultra-low-power multichannel ADC BGA MAX19526 lead time stock drop-in replacement for MAX19526 where to download MAX19526 datasheet MAX19526 CTBGA-144 footprint

Related Components & Terms

Analog Devices Maxim Integrated MAX19526EXE+ MAX19526EXE+T MAX19527EXE+ 12-bit ADC pipelined ADC analog-to-digital converter data converter data acquisition IC mixed-signal semiconductor LVCMOS TFBGA CTBGA-144 RoHS ultrasound imaging phased-array beamforming non-destructive testing vibration monitoring serial interface sample-and-hold amplifier ultrasound probe patient monitor
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details