MCP3422A0-E/MS - 18-Bit, 2-Ch ADC | Microchip | Sensor
MPN: MCP3422A0-E/MS ✓ ActiveMCP3422A0-E/MS Overview
A delta-sigma ADC is a type of analog-to-digital converter that uses continuous-time oversampling, noise shaping, and digital filtering to produce high-resolution conversion results. In the electronic-component hierarchy, this MCP3422 belongs to the ADC family, which sits within data-converter and signal-chain ICs. It is intended for low-frequency measurements where high resolution, differential input capability, and simple serial control are more important than rapid sampling.
The MCP3422A0-E/MS provides up to 18 bits of resolution across two analog input channels. Differential inputs reduce sensitivity to common-mode noise when the measured signal is applied between an AIN+ and AIN- terminal. The precision 2.048 V internal reference simplifies ratiometric or direct measurement designs by removing the need for an external reference source. The 3.75 SPS rate supports slowly changing process, temperature, pressure, and bridge-sensor signals rather than waveform capture.
Communication uses a two-wire I2C serial interface, which allows the converter to share pins with a host microcontroller or digital sensor hub. A nominal supply current of 145 µA supports low-power instrumentation, while the 2.7 V to 5.5 V operating range covers common 3.3 V and 5 V systems. The converter is designed for surface-mount assembly in compact industrial, medical, environmental, and precision measurement equipment.
Typical uses include pressure-transducer monitoring, thermistor bridges, current-shunt measurements, laboratory instrumentation, and low-rate data acquisition. Differential excitation and reference-based scaling can improve immunity to ground offsets and supply ripple, although the selected input and conversion settings must remain within the ADC’s electrical limits.
For layout, route analog inputs as short, guarded traces away from switching nodes and digital clock lines. Place the device close to its reference and decoupling network, use a quiet ground-plane arrangement, and provide input filtering appropriate to the source impedance. The slow conversion rate creates timing headroom but requires correct sampling and digital-filter configuration for stable measurements.
This product page combines the manufacturer specifications, application-oriented design guidance, package and pin information, and same-footprint replacement analysis. It also explains the electrical trade-offs involved when selecting the MCP3422A0-E/MS for slow, high-resolution differential measurements.
Drop-in alternatives for MCP3422A0-E/MS — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
Variants in this series
Same-series models that are drop-in compatible with MCP3422A0-E/MS (same form factor and footprint) — differing in Differential Input Range, Package, Resolution.
MCP3422A1T-E/MS
✅ Drop-In📋 Reference alternative (not in catalog)
MCP3422A4-E/MS
✅ Drop-InContact for price
View Datasheet →MCP3422A4T-E/MS
✅ Drop-In📋 Reference alternative (not in catalog)
MCP3422A5-E/MS
✅ Drop-In📋 Reference alternative (not in catalog)
MCP3424A0-E/MS
✅ Drop-In ⚠️ Specs Unverified📋 Reference alternative (not in catalog)
MCP3422A0-E/MS Maximum Ratings & Electrical Characteristics
| ADC Type | Delta-sigma (ΔΣ) |
| Resolution | Up to 18 bits |
| Number of Channels | 2 channels |
| Input Architecture | 2 differential inputs |
| Sampling Rate | 3.75 samples/s |
| Supply Voltage Range | 2.7 V to 5.5 V |
| Nominal Supply Current | 145 µA |
| Internal Reference Voltage | 2.048 V |
| Differential Input Range | ±2.048 V |
| Input Polarity | Bipolar differential |
| Serial Interface | I2C, 2-wire |
| Package | 8-pin MSOP, 3 mm x 3 mm x 0.85 mm |
| Mounting Type | Surface mount |
| Product Type | Low-noise, high-accuracy ADC |
| Onboard Reference | Yes |
MCP3422A0-E/MS Pin Configuration
| Pin 1 | AIN0+ — Positive input for analog channel 0 |
| Pin 2 | AIN0- — Negative input for analog channel 0 |
| Pin 3 | AIN1+ — Positive input for analog channel 1 |
| Pin 4 | AIN1- — Negative input for analog channel 1 |
| Pin 5 | SCL — I2C clock input |
| Pin 6 | SDA — I2C bidirectional data input and output |
| Pin 7 | VDD — Positive supply voltage |
| Pin 8 | VSS — Ground reference |
Typical Applications
MCP3422A0-E/MS is suitable for 6 applications: Pressure Transducer Monitoring, Temperature and Thermistor Bridge Acquisition, Current-Shunt Measurement, Environmental and IoT Sensor Hubs, Medical Instrument Signal Monitoring, Laboratory Data Acquisition.
Pressure Transducer Monitoring
The MCP3422A0-E/MS fits low-rate bridge-pressure measurements where two differential inputs can monitor separate transducers or a differential sensor pair. Its differential input architecture rejects common-mode signals that would otherwise add error to a single-ended measurement, while the onboard 2.048 V reference supports stable scaling. The 18-bit resolution and 3.75 SPS conversion rate are appropriate for slowly changing pressure in industrial equipment. Place the analog traces away from motors and switching supplies, use a dedicated analog ground path, and follow the input-filter and settling sequence in the manufacturer datasheet for reliable transducer excitation and sampling.
Recommended
Temperature and Thermistor Bridge Acquisition
The MCP3422A0-E/MS can acquire two low-rate differential temperature channels with up to 18-bit resolution. The two-channel arrangement allows a sensor bridge and a reference or compensation channel to be digitized through the same interface, reducing duplicated conversion hardware. Its 3.75 samples-per-second rate suits thermal changes measured over seconds or minutes rather than rapid transients. The 145 µA nominal supply current is useful for compact or battery-operated monitoring equipment, while the internal 2.048 V reference simplifies gain calculations when the bridge excitation is stable and appropriately scaled.
Recommended
Current-Shunt Measurement
The MCP3422A0-E/MS is suitable for measuring small differential voltages across a current-sense shunt when the voltage remains within the nominal ±2.048 V differential range. Differential sensing reduces the influence of supply noise and ground offsets compared with a single-ended measurement. The 18-bit converter can resolve slow current changes, and two channels permit simultaneous monitoring of a load and a feedback or reference condition. Because the conversion rate is 3.75 samples per second, use this approach for energy, battery, or actuator monitoring rather than high-bandwidth current waveform analysis. Input filtering must preserve the shunt measurement bandwidth.
Recommended
Environmental and IoT Sensor Hubs
The MCP3422A0-E/MS fits compact IoT sensor hubs that gather slow differential measurements from environmental or industrial sensors. Its 8-pin 3 mm x 3 mm MSOP package preserves PCB area, while the I2C interface allows the converter to share a two-wire bus with a host microcontroller. A 3.75 samples-per-second rate is appropriate for humidity, gas, soil, or atmospheric sensor outputs that change over seconds. The 2.7 V to 5.5 V operating range supports both 3.3 V and 5 V powered systems, and the 145 µA nominal supply current helps control standby consumption in distributed sensing nodes.
Recommended
Medical Instrument Signal Monitoring
The MCP3422A0-E/MS can support low-frequency sensing in medical and laboratory instruments when the selected signals fit the ±2.048 V differential range. Two differential channels provide high-resolution measurements from sensors while limiting common-mode interference. The 18-bit resolution and precision 2.048 V onboard reference are useful for bridge-based sensing, while the 3.75 samples-per-second rate matches physiological trends or process variables that do not require high-frequency sampling. Follow medical-device isolation, safety, and calibration requirements as applicable to the finished instrument; the converter’s compliance status alone does not establish system-level approval.
Recommended
Laboratory Data Acquisition
The MCP3422A0-E/MS provides a compact two-channel input for laboratory instruments that measure slow voltages with modest sampling requirements. Its differential inputs can reject offset and common-mode voltage present on long sensor connections, while the onboard 2.048 V reference reduces external reference complexity. Up to 18-bit resolution benefits precision measurement, but the 3.75 samples-per-second rate is unsuitable for general-purpose oscilloscope acquisition. Use calibration records, input-overrange protection, and shielding appropriate to the tested source. The I2C interface simplifies connection to an embedded control board while retaining programmable conversion control.
Recommended
Recommended Products Summary
Engineering reference data for MCP3422A0-E/MS — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | MCP3422A1T-E/MS | MCP3422A4-E/MS | MCP3422A4T-E/MS | MCP3422A5-E/MS | MCP3424A0-E/MS |
|---|---|---|---|---|---|---|
| Package | 8-pin MSOP, 3 mm x 3 mm x 0.85 mm | 8-pin MSOP | 8-pin MSOP | 8-pin MSOP | 8-pin MSOP | 8-pin MSOP |
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Resolution | Up to 18 bits | 18-bit family | 18-bit family | 18-bit family | 18-bit family | 18-bit family |
| Number of Channels | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels |
| Input Type | Differential | Differential family architecture | Differential family architecture | Differential family architecture | Differential family architecture | Differential family architecture |
| Internal Reference | 2.048 V precision reference | Onboard reference | Onboard reference | Onboard reference | Onboard reference | Onboard reference |
| Serial Interface | I2C, 2-wire | I2C family interface | I2C family interface | I2C family interface | I2C family interface | I2C family interface |
| Supply Voltage Range | 2.7 V to 5.5 V | 2.7 V to 5.5 V family range | 2.7 V to 5.5 V family range | 2.7 V to 5.5 V family range | 2.7 V to 5.5 V family range | 2.7 V to 5.5 V family range |
| Conversion Option | A0 | A1T | A4 | A4T | A5 | MCP3424A0 |
Key Differentiators
- Two differential channels in a compact 8-pin MSOP (vs MCP3422A4-E/MS)
- Onboard precision reference eliminates an external 2.048 V source (vs MCP3422A1T-E/MS)
- Low 145 µA nominal supply current supports compact acquisition systems (vs MCP3424A0-E/MS)
- Direct 2.7 V to 5.5 V operation covers common embedded rails (vs MCP3422A5-E/MS)
Design Notes
Keep the AIN+ and AIN- traces short, matched where practical, and routed away from switching-regulator outputs, relays, and high-current motor wiring. Connect each input to its source through the filtering network recommended in the manufacturer datasheet. A continuous ground plane provides a low-impedance return path, while guarding and shielding are important when cable-connected sensors can introduce more than 100 mV of noise.
Do not treat the 3.75 samples-per-second conversion rate as a waveform-acquisition bandwidth. Allow the converter to complete its programmed acquisition and conversion sequence before reading a result, and do not change the gain or input configuration while a conversion is active. Verify the differential voltage at the pins remains within ±2.048 V; using the larger common-mode voltage as the input limit can permanently damage the analog inputs.
Place the device close to its decoupling and analog input components, and keep the I2C clock and data routing away from the sensitive AIN+ and AIN- paths. Provide a clean return beneath or beside the analog section and use the manufacturer’s pin-description table when assigning the eight MSOP nets. For long sensor cables, use twisted-pair routing, shield grounding according to the cable arrangement, and input filters sized for the intended source impedance.
The delta-sigma digital filter suppresses noise but does not eliminate errors caused by unsuitable source impedance or settling time. Confirm that the sensor output can charge the selected input capacitor during the available acquisition period. For ratiometric bridges, keep excitation and reference paths together so supply and temperature variations cancel as intended; for absolute measurements, include the 2.048 V internal reference in the calibration procedure.
Compliance Information
The exact MCP3422A0-E/MS ordering code has not been identified as automotive-grade in the manufacturer information reviewed. Confirm RoHS, REACH, lead-free, halogen-free, and conflict-minerals documentation for the exact suffix before release.