AD7579AQ 10-Bit Parallel SAR ADC | Analog Devices
N.º da peça: AD7579AQ ✗ Fim de vidaAD7579AQ Visão geral
Alternativas drop-in para AD7579AQ — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Variantes desta série
Modelos da mesma série compatíveis como drop-in com AD7579AQ (mesmo formato e footprint) — diferindo em Package, Supply Voltage.
AD7579KN
✅ Drop-InConsulte o preço
Ver ficha técnica →AD7579JNZ
✅ Drop-In📋 Alternativa de referência (fora do catálogo)
AD7580
✅ Drop-In📋 Alternativa de referência (fora do catálogo)
AD7579AQ Classificações máximas e características elétricas
| Resolução | 10 bits |
| Converter Architecture | Successive-approximation ADC |
| Taxa de amostragem | 50 kSPS |
| Tensão de alimentação | Single +5 V supply |
| Input Range 1 | 0 V to +2.5 V |
| Input Range 2 | 0 V to +5 V |
| Input Range 3 | 2.5 V |
| Input Type | Unipolar or bipolar, depending on configuration |
| Output Interface | Parallel |
| Number of Channels | 1 |
| Encapsulamento | 24-lead CDIP (CDIP-24) |
| Package Type | Ceramic dual-inline package |
| Tipo de montagem | Through-hole |
| Status RoHS | RoHS |
Guia de Configuração de Pinos do AD7579AQ ceramic dual-inline package
Configuração de pinos para AD7579AQ (pacote ceramic dual-inline package). Este componente analógico possui pinos de entrada, saída e alimentação. Consulte o datasheet do fabricante para configurações de offset null, compensação e pino de enable. Ideal para circuitos de condicionamento de sinal e amplificadores.
Nenhum dado detalhado de pinagem disponível para AD7579AQ.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
AD7579AQ é adequado para 6 aplicaçãos: Industrial Process Measurement, Data Acquisition Systems, Legacy PLC and Control-System Retrofit, Instrumentation and Panel Meter Front Ends, Laboratory and Educational Measurement, Embedded Analog Monitoring.
Industrial Process Measurement
The AD7579AQ suits industrial process measurement designs that convert a conditioned analog sensor signal into a digital value for a controller or supervisory system. Its 10-bit resolution provides 1024 quantization levels, while the 50 kSPS sampling rate is appropriate for many temperature, pressure, level, and position signals that change more slowly than high-speed waveform inputs. The single +5 V supply simplifies systems that already distribute a 5 V control rail. Use the parallel output bus with a suitable latch or host controller, and keep the analog input and reference routing short and away from switching nodes to preserve measurement accuracy.
Recomendado
Data Acquisition Systems
The AD7579AQ can be used as the analog front-end conversion element in a parallel-bus data acquisition system. The 10-bit resolution is useful for capturing slowly varying process variables, while the 50 kSPS conversion rate supports repeated sampling of multiplexed channels. A parallel interface reduces the need for a high-speed serial clock and can simplify timing in older PLC or embedded-control architectures. The design should include input conditioning, an appropriate reference source, acquisition-time margin, and a defined sampling strategy. Because the AD7579AQ uses a 24-lead ceramic DIP footprint, board layout should preserve the mechanical clearance and pin spacing expected by that package.
Recomendado
Legacy PLC and Control-System Retrofit
The AD7579AQ is a practical choice for repairing or extending legacy PLC and control systems that use a 10-bit parallel SAR conversion stage. Its 50 kSPS throughput is more than adequate for many analog monitoring loops, and the single +5 V supply is consistent with older 5 V logic and instrumentation architectures. The parallel bus requires careful timing between conversion control, data output, and host capture. Before installing the device, confirm the original board's pinout, input polarity, reference voltage, and acquisition timing against the manufacturer datasheet, since legacy catalogs sometimes contain similar family members with different range options.
Recomendado
Instrumentation and Panel Meter Front Ends
The AD7579AQ can serve as the conversion element in instrumentation and panel-meter front ends where a stable digital value is needed for display, alarm, or setpoint processing. A 10-bit conversion result provides adequate resolution for many panel indications, and the 50 kSPS rate allows the meter to update without excessive sampling complexity. Use the ADC input stage to limit the signal to the selected 0 to +2.5 V, 0 to +5 V, or 2.5 V range, and verify the reference accuracy because it contributes directly to conversion error. The parallel digital outputs should be buffered or captured in a way that prevents switching noise from entering the analog section.
Recomendado
Laboratory and Educational Measurement
The AD7579AQ is suitable for educational and laboratory measurement setups where students or engineers need direct access to a parallel-output SAR ADC architecture. The 10-bit resolution and 50 kSPS rate provide a clear, measurable relationship between analog input and digital code without requiring a high-speed serial interface. The single +5 V supply also simplifies bench wiring when 5 V logic is already available. A useful implementation includes a controlled reference, a known input source, and a microcontroller or FPGA that captures the parallel data bus. Use the datasheet timing diagram to define the conversion-control and data-valid sequence rather than assuming a modern serial ADC protocol.
Recomendado
Embedded Analog Monitoring
The AD7579AQ can be integrated into embedded analog-monitoring equipment where several slow sensor outputs are scanned and converted through a parallel interface. The 50 kSPS rate supports periodic monitoring, and the 10-bit result is appropriate for threshold decisions, averaging, trend storage, and basic closed-loop control. The single +5 V supply allows the converter to share a system rail, although the analog reference and input path still require careful layout. Route the parallel bus away from sensitive analog inputs, provide adequate decoupling at the supply pins, and check the timing budget for the host controller. For new high-density designs, a smaller serial ADC may reduce board area and routing complexity.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para AD7579AQ — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | AD7579KN | AD7579JNZ | AD7580 |
|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 24-lead CDIP (CDIP-24) | 24-pin CDIP | 24-pin DIP | CDIP-24 |
| Resolution | 10 bits | 10 bits | 10 bits | 10 bits |
| Converter Architecture | Successive-approximation ADC | Successive-approximation ADC | Successive-approximation ADC | Successive-approximation ADC |
| Supply Voltage | Single +5 V | Single +5 V | Single +5 V | Single +5 V |
Principais diferenciais
- Closest documented same-family drop-in candidate (vs AD7579KN)
- Single-supply operation across the documented family (vs AD7580)
- Parallel output simplifies legacy host integration (vs AD7579JNZ)
Notas de projeto
Keep the analog input, reference, and supply-return paths compact and separate from the parallel digital output routing. The AD7579AQ uses a through-hole CDIP-24 footprint, so place the converter near the input connector and route the digital bus toward the host logic. Use a solid ground plane, minimize loop area around the reference network, and avoid routing clock or switching-node traces beneath the analog pins. Confirm the mechanical drawing and pin numbering from the manufacturer datasheet before fabrication.
Treat the 10-bit parallel output bus as a short, controlled digital interface. Establish a valid acquisition window around conversion completion using the datasheet timing diagram, and make sure the receiving latch or host controller meets the specified setup and hold requirements. Account for propagation delay across all ten output lines if the system latches them without a dedicated data-valid signal. If the bus is long or the board includes fast digital edges, use buffers or a locally registered interface stage instead of relying on uncontrolled bus skew.
Design the +5 V supply path with local high-frequency decoupling close to the device's supply pins and verify the reference source separately from the logic rail. Reference noise and supply variation translate directly into conversion error and code instability. Use the manufacturer power-up and decoupling recommendations, including any recommended bypass capacitors, and ensure the supply can support the converter's acquisition current plus the switching load of the connected logic. Keep analog and digital return currents separated until they meet at the device ground reference.
Do not select an AD7579 family member solely from resolution and package. The family includes different input-range and ordering-code options, and the public cross-reference results identify both CDIP and DIP variants. Verify the complete MPN, analog input polarity, reference voltage, acquisition timing, and temperature grade in the datasheet and ordering guide. Also confirm the legacy lifecycle status before committing a new production design, since a functional alternative may not provide the same supply, sourcing, or long-term availability profile.
Informações de conformidade
The RoHS field is based on the RoHS marking in the distributor product description. No additional REACH, halogen-free, or conflict-minerals declarations were identified for the exact MPN.