AD7579BQ - 10-Bit, 50 kSPS ADC | Analog Devices
N.º da peça: AD7579BQ ✓ AtivoAD7579BQ Visão geral
An ADC is a data-acquisition IC that converts an analog voltage into a digital code for processing, display, storage, or control. The AD7579 belongs to the successive-approximation ADC, data-converter, signal-chain, and semiconductor hierarchies. Its parallel interface transfers each 10-bit result through dedicated digital lines, avoiding the serial signaling required by many contemporary converters.
The principal device characteristics are a resolution of 10 bits, a conversion rate of 50 kSPS, a single analog input, parallel output, and operation from a +5 V supply. Analog input ranges listed for the AD7579 family include 0 to +2.5 V and 0 to +5 V. This combination gives designers a straightforward interface for sampling slowly changing or moderate-bandwidth analog signals when a byte-oriented parallel bus is available.
The LC2MOS implementation supports the converter's sampling and successive-approximation conversion operation. Because the AD7579 presents a parallel result, the associated interface must provide enough input and output logic paths for the converter data and control signals. The 24-lead ceramic DIP package is mechanically conventional and suited to through-hole assembly, prototype instrumentation, and legacy industrial equipment where surface-mount packages would complicate inspection or replacement.
Typical uses include multichannel process monitoring, sensor-interface modules, laboratory measurement equipment, digital panel meters, and closed-loop control systems. The 50 kSPS throughput can support rapidly updated measurements when the analog front end, reference, and signal source have suitable settling behavior. The 10-bit result provides 1,024 distinct digital codes for the selected input range.
When implementing the converter, use the manufacturer pin-description table to assign every power, analog, control, and digital line. Place bypass capacitors close to the supply pins and route the analog input with minimal parasitic pickup. Confirm the exact input range, acquisition timing, reference requirements, and logic levels in the manufacturer datasheet before finalizing the circuit.
This page consolidates the AD7579BQ identification, 50 kSPS throughput, 10-bit resolution, package information, application guidance, and replacement assessment. It also distinguishes verified same-package interchangeability from related ADI converters that require different packages, interfaces, or analog-input arrangements.
Alternativas drop-in para AD7579BQ — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Nenhuma alternativa drop-in disponível para este produto.
Solicitar alternativasAD7579BQ Classificações máximas e características elétricas
| ADC Type | Successive-approximation ADC |
| Resolução | 10 bit |
| Conversion Throughput | 50 kSPS |
| Architecture | LC2MOS |
| Input Channel Count | 1 channel |
| Output Interface | Parallel |
| Tensão de alimentação | +5 V |
| Input Range 1 | 0 V to +2.5 V |
| Input Range 2 | 0 V to +5 V |
| Encapsulamento | 24-CDIP |
| Packaging | Tube |
| Contagem de pinos | 24 pins |
Guia de Configuração de Pinos do AD7579BQ 24-cdip
Configuração de pinos para AD7579BQ (pacote 24-cdip). Este componente analógico possui pinos de entrada, saída e alimentação. Consulte o datasheet do fabricante para configurações de offset null, compensação e pino de enable. Ideal para circuitos de condicionamento de sinal e amplificadores.
Nenhum dado detalhado de pinagem disponível para AD7579BQ.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
AD7579BQ é adequado para 6 aplicaçãos: Industrial Process Measurement, Embedded Sensor Interface, Laboratory Instrumentation, Digital Panel Meter, Closed-Loop Control, Data Acquisition and Logging.
Industrial Process Measurement
The AD7579BQ fits industrial process-measurement boards that monitor a conditioned pressure, temperature, level, or flow signal and need a straightforward 10-bit conversion result. Its 50 kSPS throughput supports frequent updates, while the 10-bit resolution provides 1,024 codes across the selected unipolar input range. The parallel output can connect directly to byte-oriented control logic. A practical implementation places the converter behind input protection and filtering, then uses its +5 V supply and reference arrangement from the manufacturer design guidance. The 24-CDIP package also simplifies through-hole assembly in serviceable industrial equipment.
Recomendado
Embedded Sensor Interface
The AD7579BQ is appropriate for an embedded sensor-interface module that receives a conditioned analog voltage and must transfer a compact digital measurement to a host controller. Its 10-bit SAR conversion and 50 kSPS throughput provide sufficient resolution and update capability for many slow-to-moderate sensor signals. The single +5 V supply simplifies power planning when the module already operates on +5 V logic. A parallel bus requires careful allocation of data and control lines, so the host processor should support the converter interface directly or through an appropriate latch and bus-control circuit.
Recomendado
Laboratory Instrumentation
The AD7579BQ can serve as the acquisition element in laboratory instrumentation where a readable 10-bit measurement and conventional through-hole construction are useful. At 50 kSPS, the converter is capable of handling many instrument channels sampled at moderate rates, provided the analog source settles correctly during acquisition. Its parallel output makes the result available to a microprocessor, FPGA, or data logger without a serial protocol converter. Designers should pay close attention to reference stability, input conditioning, grounding, and digital-bus timing when establishing measurement uncertainty.
Recomendado
Digital Panel Meter
The AD7579BQ is well suited to digital panel-meter and front-panel measurement designs that acquire a scaled sensor voltage and present the result through a local controller. A 10-bit code supports 1,024 discrete levels, which can be effective for coarse indication or simple threshold supervision, while 50 kSPS provides responsive updates. The parallel interface allows the meter controller to capture the conversion result with direct digital input lines. The through-hole 24-CDIP package is also convenient for hand-built or serviceable instruments where replacing a surface-mount converter would reduce maintainability.
Recomendado
Closed-Loop Control
The AD7579BQ can form the measurement front end of a closed-loop control system that compares a conditioned analog command or feedback signal with a setpoint. The 50 kSPS conversion rate can support control loops operating in the hundreds-of-hertz range or lower after accounting for controller latency and filtering. The 10-bit result also defines a finite command granularity, so loop stability and actuator resolution must be evaluated against that step size. The parallel data interface permits fast deterministic reads, while the converter's +5 V operation can simplify integration with legacy control logic.
Recomendado
Data Acquisition and Logging
The AD7579BQ is suitable for data-acquisition and logging equipment that periodically samples one analog channel and records the result. At 50 kSPS, it supports dense time-series capture when the source bandwidth and acquisition timing permit it. The 10-bit resolution balances conversion throughput, interface simplicity, and storage requirements for supervisory or diagnostic measurements. In a multichannel system, multiplexing and analog settling become important, so each converter should have sufficient acquisition time and an input path designed to avoid channel-to-channel interaction. A parallel interface can feed a host processor efficiently.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para AD7579BQ — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto |
|---|---|
| Package | 24-CDIP |
| Brand | Analog Devices |
| Resolution | 10 bit |
| Conversion Throughput | 50 kSPS |
| Converter Architecture | Successive-approximation ADC |
| Input Channel Count | 1 channel |
| Digital Output Interface | Parallel |
| Supply Voltage | +5 V |
Principais diferenciais
- Direct parallel acquisition interface (vs AD7580)
- Legacy-compatible 24-CDIP construction (vs AD7579JP)
- Balanced conversion rate and resolution (vs AD7581)
Notas de projeto
Route the analog input away from the parallel data and control outputs to minimize capacitive coupling into the sampled signal. Keep the input path short and place any filtering or protection components close to the converter pins. A single-ended analog source still requires a low-impedance return path to the converter ground; do not treat the digital ground and analog signal reference as interchangeable without following the manufacturer grounding guidance.
Use the manufacturer-specified supply and bypass arrangements for the single +5 V rail, placing each bypass capacitor as close as practical to its intended supply pin. Check the converter's total supply current, reference requirements, and digital-output loading before sizing the rail. The 24-CDIP package does not eliminate the need for a stable analog supply, particularly when the converter is used with long digital bus traces or switching circuitry nearby.
Treat the parallel output as a timing-sensitive bus. Confirm output timing, propagation delay, logic levels, and data-valid requirements in the manufacturer timing diagrams before assigning it to a slow or deeply loaded bus. Add proper bus buffering when fan-out or trace length makes direct loading uncertain. Clocking or latching at the wrong point can capture partially updated results even when the converter itself is operating correctly.
Do not substitute a related ADI converter solely because it has the same 10-bit resolution and 50 kSPS headline rate. The AD7579 family includes devices with different analog-input arrangements and package options. A valid replacement must match the 24-CDIP mechanical outline, pin numbering, supply arrangement, interface timing, input range, and acquisition requirements. Verify each point against the manufacturer datasheet before approving a substitution.
Informações de conformidade
No specific RoHS, REACH, halogen-free, lead-free, or conflict-minerals declaration was identified for AD7579BQ. AEC-Q100 is not applicable to this general-purpose data-conversion device.