AD7580BQ - 10-Bit Dual-Input ADC | Analog Devices
N.º da peça: AD7580BQ ✓ AtivoAD7580BQ Visão geral
An analog-to-digital converter, or ADC, converts a continuously varying analog voltage into a numeric value for processing, measurement, or control. The AD7580 belongs to the successive-approximation ADC family within the broader analog-to-digital converter and data-acquisition IC hierarchy. Its 10-bit resolution produces 1,024 possible digital codes, making it appropriate for compact measurement systems that need moderate precision, straightforward interfacing, and reliable conversion timing.
The primary conversion characteristics are a 10-bit resolution, two analog input channels, an 18.5 microsecond conversion time, and a 50 kSPS maximum sample rate. The specified linearity error is 0.049 percent. Operation from only a +5 V supply simplifies analog-system design, while selectable input ranges include 0 to +2.5 V, 0 to +5 V, and a bipolar 2.5 V range according to the Analog Devices AD7580 product documentation.
The AD7580 uses a successive-approximation conversion architecture, balancing conversion time with circuit complexity. At an 18.5 microsecond conversion time, it is suited to supervisory acquisition, process measurement, and instrumentation rather than high-bandwidth waveform capture. Its 50 kSPS throughput supports rapid sampling loops when the surrounding system does not require simultaneous conversion. The two input channels expand utility in temperature, pressure, bridge, or control applications where several slowly changing analog quantities must be measured.
Typical uses include industrial process monitoring, sensor-interface measurement, test equipment, and embedded control systems. The 50 kSPS rate allows a 50 kHz theoretical input bandwidth under ideal sampling conditions, although practical analog filtering and source impedance remain important. The 24-lead ceramic DIP format is particularly useful for leaded industrial assemblies where through-hole insertion, inspection, and rework are preferred over fine-pitch surface mounting.
For reliable circuit implementation, use the pin-description and connection diagrams in the Analog Devices AD7580 datasheet when assigning signals and designing the analog input path. Decouple the +5 V supply close to the device, keep analog traces short, and provide a low-impedance reference source. Because the converter is intended for a single +5 V supply, verify that every attached digital and analog interface signal remains within the device's specified voltage limits before power-up.
This page combines the manufacturer's core input, conversion, and packaging information with procurement guidance and engineering-focused implementation notes. It also distinguishes the AD7580BQ from other AD7580 ordering variants and explains where engineers should verify package, pin, lifecycle, and sourcing details before committing a design to production.
Alternativas drop-in para AD7580BQ — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Nenhuma alternativa drop-in disponível para este produto.
Solicitar alternativasAD7580BQ Classificações máximas e características elétricas
| ADC Type | Successive Approximation ADC |
| Resolução | 10 bit |
| Number of Analog Input Channels | 2 channels |
| Conversion Time | 18.5 us |
| Sample Rate | 0.05 MSPS (50 kSPS) |
| Linearity Error | 0.049% |
| Tensão de alimentação | +5 V |
| Unipolar Input Range 1 | 0 V to +2.5 V |
| Unipolar Input Range 2 | 0 V to +5 V |
| Bipolar Input Range | -2.5 V to +2.5 V |
| Encapsulamento | 24-lead ceramic DIP (24-CDIP) |
| Terminal Count | 24 terminals |
| Tipo de montagem | Through Hole |
| Package Shape | Rectangular |
Guia de Configuração de Pinos do AD7580BQ rectangular
Configuração de pinos para AD7580BQ (pacote rectangular). Este componente analógico possui pinos de entrada, saída e alimentação. Consulte o datasheet do fabricante para configurações de offset null, compensação e pino de enable. Ideal para circuitos de condicionamento de sinal e amplificadores.
Nenhum dado detalhado de pinagem disponível para AD7580BQ.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
AD7580BQ é adequado para 6 aplicaçãos: Industrial Process Monitoring, Temperature Measurement, Bridge Sensor Acquisition, Test and Measurement Equipment, Embedded Control and Data Logging, Power Supply Supervision.
Industrial Process Monitoring
The AD7580BQ fits industrial process monitoring where two analog sensor signals must be digitized from a single +5 V supply. Its 10-bit resolution and 0.049 percent linearity error provide 1,024 digital code levels, while the 50 kSPS rate is more than adequate for supervisory readings from temperature, pressure, or level sensors. The two input channels reduce the number of separate converters needed when measurements update at similar rates. Engineers should condition each sensor to the selected 0 to +2.5 V, 0 to +5 V, or bipolar range and use the manufacturer pin-description table when routing the analog inputs. The 24-lead ceramic DIP package also supports through-hole assembly in leaded industrial equipment.
Temperature Measurement
The AD7580BQ can digitize a conditioned temperature signal in an industrial transmitter or environmental controller. A 50 kSPS conversion rate allows the controller to refresh the temperature reading frequently enough for supervisory regulation, while the 10-bit resolution provides adequate code spacing for many temperature-monitoring tasks. Use the converter's two channels when comparing a temperature sensor with a second reference or diagnostic signal. The 18.5 microsecond conversion time should not determine the control-loop bandwidth; instead, the system loop and sensor thermal time constant will usually dominate. Keep the analog front end close to the converter and refer to the AD7580 documentation for supply decoupling and grounding details.
Bridge Sensor Acquisition
The AD7580BQ is appropriate for slow bridge-sensor measurements after a suitable bridge amplifier and low-noise analog front end have conditioned the differential signal. The selectable bipolar 2.5 V input configuration can simplify acquisition of a signal centered around 2.5 V, while the 10-bit resolution supports basic force, pressure, or position monitoring. Its two channels can support a sensing bridge and a calibration channel when sampling rates permit. The converter does not replace excitation current, differential instrumentation, or input filtering; those functions must be designed separately. Because the AD7580BQ operates from one +5 V rail, its analog interface should remain within the documented input and reference limits.
Test and Measurement Equipment
The AD7580BQ can serve as a measurement converter in compact bench or panel instruments that require moderate resolution rather than high-frequency acquisition. Its 18.5 microsecond conversion time supports sampling rates up to 50 kSPS, and the 0.049 percent linearity error is suitable for general-purpose voltage measurement. The two analog channels can acquire a measurement and a reference value, while the single +5 V supply requirement simplifies analog power planning. For laboratory instruments, pay particular attention to reference stability, source impedance, analog grounding, and input settling. The through-hole ceramic DIP package is practical for leaded instruments, but thermal performance and supply noise still require validation in the final enclosure.
Embedded Control and Data Logging
The AD7580BQ is useful in embedded control and data-logging systems that periodically measure analog conditions rather than continuously capture waveforms. Two channels can sample related control variables within a common acquisition cycle, and the 50 kSPS throughput provides ample margin for temperature, position, or supply monitoring. The 10-bit output is also simple to process with a microcontroller or programmable controller. Designers should allow the converter's 18.5 microsecond acquisition time when sequencing multiple channels and should verify digital-interface levels against the +5 V supply configuration. Use the manufacturer's connection diagrams to separate analog and digital returns appropriately and to establish a stable reference before taking precision measurements.
Power Supply Supervision
The AD7580BQ can monitor two power-related voltages in a control, protection, or diagnostic system by using its two analog input channels and selectable measurement ranges. Its 0 to +5 V range is directly relevant to a +5 V rail, while the 0 to +2.5 V range can accommodate suitably scaled intermediate signals. The 50 kSPS rate supports frequent supervision without demanding high throughput, and the 10-bit resolution offers a practical diagnostic code space. The converter is not itself a protection IC, so thresholding and shutdown decisions belong in the controller or comparator logic. Confirm absolute maximum input conditions, reference stability, and filtering before using it for safety-critical decisions.
Dados de referência de engenharia para AD7580BQ — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto |
|---|---|
| Package | 24-lead ceramic DIP (24-CDIP) |
| Brand | Analog Devices |
| ADC Type | Successive Approximation ADC |
| Resolution | 10 bit |
| Analog Input Channels | 2 channels |
| Conversion Time | 18.5 us |
| Sample Rate | 0.05 MSPS (50 kSPS) |
| Linearity Error | 0.049% |
| Supply Voltage | +5 V |
| Input Ranges | 0 to +2.5 V, 0 to +5 V, and bipolar 2.5 V |
Notas de projeto
Route the analog inputs and reference connection directly to their intended AD7580BQ pins, avoiding long traces through switching circuitry. Keep the +5 V supply bypass capacitor close to the supply pins and follow the manufacturer connection diagram for component placement. Because this is a through-hole ceramic DIP device, preserve adequate spacing around adjacent components so the socket or leads remain accessible during inspection and rework.
Do not select an input range solely from the nominal supply voltage; check the permitted input and reference relationship in the AD7580 datasheet before applying sensor or system voltages. The converter supports 0 to +2.5 V, 0 to +5 V, and bipolar operation, but incorrect mode or reference configuration can invalidate measurements. Also account for the 18.5 microsecond conversion time when designing control-loop timing or multiplexed acquisition sequences.
Use the manufacturer reference and grounding configuration as the basis for PCB implementation. Keep sensitive analog traces short, place filtering capacitors at the source of interference, and prevent digital return currents from flowing beneath the analog input or reference paths. The 10-bit resolution can expose more than 0.049 percent linearity error if the source impedance, settling time, reference ripple, or grounding introduces additional error.
Informações de conformidade
The AD7580BQ is a 10-bit sampling ADC rather than an automotive-qualified power semiconductor. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations were not established for this ordering code.