Analog Devices

AD7714YR - 24-Bit Sigma-Delta ADC | Analog Devices

N.º da peça: AD7714YR ✓ Ativo
3 V/5 V Vdss 24-SOIC Package
MOQ: 1 |

AD7714YR Visão geral

The Analog Devices AD7714YR is a production CMOS, 24-bit sigma-delta analog-to-digital converter with 500 µA typical power consumption, a 3 V/5 V supply range, three differential inputs or five pseudo-differential inputs, and a 24-SOIC package. It combines programmable gain, differential referencing, digital filtering, calibration, and serial output in one low-frequency signal-conditioning ADC.

A sigma-delta ADC is a voltage regulator category relative to the broader ADC hierarchy: it oversamples an analog input and uses digital filtering and decimation to produce a high-resolution conversion result. The AD7714 belongs to the low-frequency measurement ADC category, where the priority is accurate conversion of slowly changing differential sensor signals rather than high-frequency waveform capture. Its differential reference input supports ratiometric measurement, while the serial interface reduces the number of interconnections required between the converter and a microcontroller or DSP.

The AD7714YR accepts three differential analog inputs that can also be configured as five pseudo-differential channels. Its 24-bit resolution and programmable input gain suit pressure, temperature, load-cell, bridge, and other transducer measurements where small signal changes must be resolved accurately. On-chip registers allow control of filter cutoff, gain, channel selection, signal polarity, and calibration modes. A typical 500 µA power figure makes the device suitable for power-conscious instrumentation when the selected output data rate and digital filter allow that operating condition.

Internally, the converter combines a sigma-delta modulator with programmable digital filtering and calibration functions. The three-wire serial interface reduces wiring between the ADC and a digital controller, which is especially useful in isolated or space-constrained measurement systems. Differential input and reference architecture can improve rejection of common-mode noise when the transducer, reference, and analog ground arrangement are implemented carefully. Designers must still observe the datasheet limits for input voltage, reference voltage, supply sequencing, filter settings, and analog grounding.

Typical applications include industrial process measurement, bridge-based sensors, laboratory instrumentation, data acquisition, medical monitoring equipment, and embedded low-frequency measurement systems. The converter can sit directly between a sensor and a microcontroller or DSP, reducing the need for separate analog-conditioning stages when the required gain, filtering, and calibration are supported by its internal functions.

Design the analog front end around the AD7714 Data Sheet, Rev. C, including the recommended input and reference filtering, grounding, and supply bypassing. Verify acquisition time against the selected filter cutoff and output data rate, and ensure input and reference signals remain within their absolute maximum and operating limits. For an existing AD7714 design, compare suffix and temperature-grade requirements before ordering a replacement.

This page combines the manufacturer's device characteristics, verified product listings, and cross-reference results with practical replacement and design guidance. It highlights where AD7714YR and AD7714YRZ are electrically related, identifies the RoHS packaging distinction, and separates confirmed drop-in information from alternatives that would require additional engineering verification.

Alternativas drop-in para AD7714YR — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

AD7714YRZ

✅ Drop-In
📦 24-SOIC
Functionally identical 24-bit ADC; AD7714YRZ has RoHS-compliant packaging, while AD7714YR is identified as the non-RoHS package variant, for a 0% functional rating difference

📋 Alternativa de referência (fora do catálogo)

AD7714YR Classificações máximas e características elétricas

ADC Resolution 24 bit
Conversion Architecture Sigma-delta
Analog Input Configuration 3 differential inputs or 5 pseudo-differential inputs
Supply Voltage Range 3 V/5 V
Power Consumption 500 µA typical
Reference Input Differential reference input
Digital Interface 3-wire serial interface
On-Chip Control Programmable filter cutoff, input gain, channel selection, signal polarity, and calibration modes
Process Technology CMOS
Encapsulamento 24-SOIC
Production Status Production
Status RoHS Non-compliant packaging variant
REACH Status unknown
AEC-Q100 Qualification not_applicable

Guia de Configuração de Pinos do AD7714YR 24-soic

Configuração de pinos para AD7714YR (pacote 24-soic). Este componente analógico possui pinos de entrada, saída e alimentação. Consulte o datasheet do fabricante para configurações de offset null, compensação e pino de enable. Ideal para circuitos de condicionamento de sinal e amplificadores.

Diagrama de pinagem do pacote 24-soic para AD7714YR

Nenhum dado detalhado de pinagem disponível para AD7714YR.

Consulte a ficha técnica para a configuração completa dos pinos.

Aplicações típicas

AD7714YR é adequado para 6 aplicaçãos: Bridge Sensor Measurement, Industrial Process Monitoring, Temperature and Resistance Sensing, Laboratory Instrumentation, Medical Monitoring Equipment, Embedded Data Acquisition.

⚡

Bridge Sensor Measurement

The AD7714YR fits bridge-based load cells, pressure cells, and other resistive transducers that produce small differential signals. Its three differential inputs, programmable gain, 24-bit resolution, and differential reference input support accurate low-frequency acquisition without requiring a separate analog amplifier for every channel. The sensor bridge can be excited from the system supply while its differential output feeds the converter, although the actual excitation and input range must match the device limits. Digital filtering and calibration can be configured on-chip. Design the analog section so the bridge return connects cleanly to the converter's analog reference system and verify excitation drift against the required measurement accuracy.

🏭

Industrial Process Monitoring

The AD7714YR is appropriate for industrial systems that monitor slow pressure, temperature, flow, or level signals and require repeatable multi-channel performance. Its 24-bit sigma-delta architecture provides high nominal resolution, while five pseudo-differential input configurations allow several sensing elements to share one converter. The 3 V/5 V supply compatibility and 500 µA typical power figure support compact controller designs, and the three-wire serial interface minimizes interconnections to a microcontroller. Configure gain, polarity, filter cutoff, and channel timing for each sensor. Environmental isolation, surge protection, and sensor excitation circuitry remain external design requirements.

🌡️

Temperature and Resistance Sensing

The AD7714YR can acquire low-level resistive or ratiometric temperature-sensor signals when the application benefits from programmable gain, selectable digital filtering, and on-chip calibration. Differential inputs allow a bridge or resistive network to be referenced carefully, while the differential reference input supports measurement techniques that compensate for excitation or reference variation. The ADC's 24-bit resolution is useful when the useful signal occupies only a small portion of the full-scale range. Select the gain and filter settings so sensor settling time remains acceptable, and follow the manufacturer's recommended reference and input filtering to control out-of-band noise.

🔧

Laboratory Instrumentation

The AD7714YR suits laboratory instruments requiring repeatable low-frequency measurements from multiple slow analog sources. Programmable channel selection, gain, polarity, calibration modes, and filter cutoff allow the same converter to serve several test ranges without a large external analog-conditioning matrix. The 24-bit result format and differential reference architecture are valuable in ratio-based measurements where reference stability is part of the calibration model. The serial interface simplifies connection to a DSP or embedded controller. For precision instruments, preserve analog grounding, use low-noise reference components, and verify the selected digital filter against the required settling time and measurement bandwidth.

💊

Medical Monitoring Equipment

The AD7714YR can be used in low-frequency medical monitoring equipment when a sensor produces a differential signal and the system needs integrated gain, filtering, and calibration control. Its 24-bit conversion resolution supports fine measurement increments, and the three differential inputs or five pseudo-differential channels provide flexibility for multiple sensing elements. The 3 V/5 V operation is compatible with embedded systems, while the three-wire interface limits controller connections. Medical designs still require separate protection, isolation, diagnostic, and regulatory measures beyond the converter itself. Validate leakage, noise, calibration strategy, and fault behavior at the complete system level.

🧩

Embedded Data Acquisition

The AD7714YR is useful in embedded data-acquisition systems that gather several slowly changing analog channels and transfer results through a compact serial interface. Its on-chip programming of gain, filter cutoff, channel selection, polarity, and calibration reduces the need for external analog switches and conditioning stages. A microcontroller or DSP can configure the converter and consume its digital output over the three-wire interface. The converter's 500 µA typical power figure is attractive in compact equipment, but the selected data rate and filter settings determine the complete system power budget. Validate conversion timing, grounding, reference startup, and calibration intervals for the deployed sensors.

What is the AD7714YR?
The AD7714YR is a 24-bit sigma-delta ADC with three differential inputs, five pseudo-differential input options, programmable signal conditioning, and a 3-wire serial interface. According to the Analog Devices AD7714 Data Sheet, Rev. C, it is intended for low-frequency measurement systems using sensors such as bridges and resistive transducers. The device operates from a 3 V/5 V supply and consumes 500 µA typical, and it is packaged in a 24-SOIC.
What are the key specifications of AD7714YR that engineers should know?
The AD7714YR combines 24-bit resolution, three differential or five pseudo-differential inputs, a differential reference, and programmable digital filtering in a 24-SOIC package. The Analog Devices AD7714 Data Sheet, Rev. C, identifies a 3 V/5 V supply and 500 µA typical power consumption. Its registers control gain, filter cutoff, channel selection, polarity, and calibration, making it a complete signal-conditioning ADC for low-frequency transducer measurements rather than a bare conversion stage.
Where can I download the AD7714YR datasheet PDF?
The official AD7714YR datasheet PDF is available from Analog Devices through the AD7714 Data Sheet, Rev. C. The manufacturer document describes the complete analog front end, digital interface, register programming, electrical characteristics, and application information. Use the Analog Devices product page to access the current revision and related evaluation resources, and consult the pin-description table in the datasheet before assigning PCB tracks or connecting analog signals.
What is the AD7714YR pinout?
The AD7714YR uses a 24-SOIC package with analog inputs, reference connections, power pins, grounding, digital interface signals, and control functions. The Analog Devices AD7714 Data Sheet, Rev. C, contains the authoritative pin-description table and package drawings. Use that table for the exact pin numbers because exposed-pad details and selected package variants must not be inferred from a generic 24-pin SOIC footprint.
How many analog input channels does AD7714YR have?
The AD7714YR supports three differential analog inputs and can be configured for five pseudo-differential inputs. This channel flexibility allows one converter to serve several low-frequency sensors while retaining programmable gain, filter selection, polarity, and calibration controls. The Analog Devices AD7714 Data Sheet, Rev. C, describes the multiplexing and configuration options, which should be checked against the required sensor topology during design.
What applications are suitable for AD7714YR?
The AD7714YR is suitable for low-frequency measurement systems that need high resolution and integrated signal conditioning. Typical uses include bridge sensors, pressure and temperature transducers, industrial process monitoring, laboratory instruments, medical monitoring, and microcontroller-based data acquisition. Its 24-bit sigma-delta architecture and differential inputs are useful for slow sensor signals, while the 3-wire serial interface simplifies connection to a microcontroller or DSP.
What is the difference between AD7714YR and AD7714YRZ?
The AD7714YR and AD7714YRZ are functionally described as the same 24-bit sigma-delta ADC, but their packaging compliance differs. Cross-reference information identifies the Z-suffixed AD7714YRZ as the RoHS-compliant package variant and AD7714YR as the older non-RoHS variant. Both use the same 24-SOIC format for this ordering comparison, making AD7714YRZ a likely drop-in where its lead finish, marking, and procurement requirements are acceptable.
Can AD7714YRZ replace AD7714YR on the same PCB?
Yes, AD7714YRZ is the closest confirmed drop-in candidate for AD7714YR because cross-reference information describes the two devices as functionally identical 24-bit sigma-delta ADCs in the same 24-SOIC format. The primary measurable distinction is that AD7714YRZ uses RoHS-compliant packaging, whereas AD7714YR is identified as the non-RoHS package variant. Confirm temperature grade, marking, orientation, and production requirements before releasing the substitution.
What is the best drop-in replacement for AD7714YR?
AD7714YRZ is the best confirmed drop-in replacement identified for AD7714YR because both are functionally identical 24-bit sigma-delta ADCs in a 24-SOIC package. Their principal difference is packaging compliance: AD7714YRZ is identified as RoHS-compliant, while AD7714YR is the older non-RoHS variant. The replacement should still be checked for temperature-grade, lead-finish, calibration, and lifecycle requirements specific to the finished equipment.
When should I choose AD7714YR instead of AD7714YRZ?
Choose AD7714YR when an existing approved design specifically requires the non-Z ordering variant and its documented packaging status is acceptable. Choose AD7714YRZ when the same electrical and pin configuration is needed with RoHS-compliant packaging. Because the devices are functionally identical in the verified comparison, the choice should be driven by environmental compliance, procurement documentation, existing BOM approval, and production continuity rather than expected conversion-performance differences.
Is AD7714YR suitable for bridge and low-level sensor measurements?
Yes, AD7714YR is suitable for bridge and other low-level sensor measurements because it combines a 24-bit sigma-delta converter, programmable gain, differential inputs, a differential reference, digital filtering, and calibration. The Analog Devices AD7714 Data Sheet, Rev. C, positions the device as a complete front end for low-frequency measurement. Actual accuracy depends on the transducer, excitation, reference quality, analog layout, filter settings, and calibration procedure.
What design considerations apply when using AD7714YR?
The principal AD7714YR design considerations are input and reference range compliance, differential signal pairing, analog grounding, supply bypassing, filter selection, and acquisition timing. Program the conversion clock, output rate, digital filter cutoff, gain, polarity, and calibration mode according to the Analog Devices AD7714 Data Sheet, Rev. C. Place analog and reference connections away from fast digital signals, and verify that selected settings provide sufficient conversion time for the measurement bandwidth.
How does AD7714YR compare with AD7710AR?
AD7714YR is specified as a 24-bit sigma-delta ADC with three differential or five pseudo-differential inputs, whereas a verified direct comparison is available for AD7710AR and AD7714YR but does not expose complete parameter tables in the available source. Both belong to Analog Devices' low-frequency measurement ADC portfolio and can serve related sensor-acquisition systems. The AD7714YR should be preferred when its 24-bit resolution, 3 V/5 V operation, and five-channel pseudo-differential configuration match the design.
Is AD7714YR available for quotation?
AD7714YR can be requested through the Request a Quote form on this page, where the current commercial terms and delivery schedule should be confirmed for the exact suffix and quantity. Manufacturer and distributor listings identify the device as a production part, but live inventory and lead time can change by order volume and packaging requirement. Provide the target quantity, date code requirements, and destination country when requesting the quotation.
What is the lead time and stock status for AD7714YR?
Current stock and lead time for AD7714YR should be confirmed through the Request a Quote form on this page rather than inferred from a general listing. The Analog Devices product page identifies the family as production, and multiple distribution listings reference the exact AD7714YR ordering code, but those listings do not establish a guaranteed allocation. Submit the required quantity and delivery date so the current manufacturing and distribution position can be matched to the order.

Dados de referência de engenharia para AD7714YR — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose AD7714YR when an approved design specifically calls for the original ordering variant and its non-RoHS packaging status is acceptable for the finished product. Choose AD7714YRZ when a drop-in replacement must use RoHS-compliant packaging; it is functionally described as identical to AD7714YR and retains the 24-bit sigma-delta architecture, 3 V/5 V supply, 3 differential or 5 pseudo-differential input arrangement, and 24-SOIC format. Neither option changes the conversion performance identified in the comparison. Confirm the temperature grade, lead finish, device marking, orientation, and qualification requirements before substitution. AD7710AR and AD7708BR are relevant measurement ADCs for broader design evaluation, but they should not be treated as direct drop-in replacements without package-level and interface verification. For new designs that require equivalent functionality with RoHS packaging, AD7714YRZ is the cleaner choice because it preserves the functional architecture while using the compliant package variant.

Comparação com alternativas

Parâmetro Este produto AD7714YRZ
Brand Analog Devices Analog Devices
Package 24-SOIC 24-SOIC
ADC Resolution 24 bit 24 bit
Conversion Architecture Sigma-delta Sigma-delta
Supply Voltage 3 V/5 V 3 V/5 V
Power Consumption 500 µA typical 500 µA typical
Analog Inputs 3 differential or 5 pseudo-differential 3 differential or 5 pseudo-differential
RoHS Packaging Status Non-compliant packaging variant RoHS-compliant packaging variant

Principais diferenciais

  • Direct functional replacement with a different packaging-compliance status (vs AD7714YRZ)
  • Integrated multi-channel signal conditioning (vs AD7714YRZ)
  • Low-power operation for embedded measurement (vs AD7714YRZ)

Notas de projeto

Route each differential input as a compact, closely matched pair and keep analog traces away from clock, serial-interface, and switching-supply nodes. Place the input, reference, and supply bypass components close to their associated pins using the connection and layout guidance in the Analog Devices AD7714 Data Sheet, Rev. C. Preserve a continuous ground path under the analog section and use the package's exposed thermal and electrical connection exactly as specified by the manufacturer.

Design the analog and digital supplies around the AD7714's 3 V/5 V operating range and account for the complete load current rather than only the 500 µA typical ADC figure. Bypass each supply connection locally and provide clean reference voltage within the datasheet limits. Check startup sequencing if the reference or sensor can be present before the converter supply, because uncontrolled input or reference voltage can violate device operating limits and compromise measurement accuracy.

The output data rate and digital filter cutoff must be selected together with the sensor's settling behavior. A narrow digital filter can improve rejection of high-frequency noise but increases acquisition time, so confirm that every selected channel settles before its conversion is read. Use the on-chip calibration and polarity controls only with a defined register sequence. For bridge or ratiometric measurements, keep reference routing quiet and verify that residual reference noise maps to the target measurement resolution.

Do not treat AD7714YR and AD7714YRZ as electrically different performance grades solely because of the suffix. Cross-reference information identifies them as functionally identical, with the primary distinction being RoHS packaging status. A replacement is appropriate only after confirming temperature grade, package orientation, marking, calibration behavior, and approved-bom requirements. Also avoid assuming that the 24-bit resolution alone determines system accuracy; front-end noise, reference quality, excitation stability, grounding, and filtering remain part of the measurement chain.

Informações de conformidade

RoHS
Non Compliant
REACH
Unknown
AEC-Q100
Not Applicable
Sem chumbo
Unknown
Sem halogênios
Unknown
Minerais de conflito
Unknown

Cross-reference information identifies AD7714YR as the older non-RoHS package variant and AD7714YRZ as the RoHS-compliant variant. Other compliance attributes are not stated.

Dados verificados em: 2026-11-22 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

AD7714YR datasheet AD7714YR specifications AD7714YR pinout AD7714YR datasheet pdf AD7714YR application circuit AD7714YR equivalent AD7714YR replacement AD7714YR cross reference AD7714YR vs AD7714YRZ Analog Devices AD7714YR AD7714YR 24-SOIC footprint AD7714YR price AD7714YR stock AD7714YR 24 bit sigma delta ADC AD7714YR bridge sensor

Componentes & termos relacionados

Analog Devices AD7714YR AD7714YRZ AD7714 AD7710AR AD7708BR AD7705BR 24-bit ADC sigma-delta ADC analog-to-digital converter signal-conditioning ADC low-frequency measurement differential input pseudo-differential input differential reference programmable gain digital filter cutoff calibration mode 3-wire serial interface 24-SOIC CMOS 3 V/5 V supply 500 µA power consumption RoHS
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue
Ver detalhes da RFQ