AD7828KN - 8-Channel 8-Bit 50 kSPS ADC | Analog Devices
N.º da peça: AD7828KN ✗ Fim de vidaAD7828KN Visão geral
An ADC converts continuously varying analog voltages into digital values for processing by microprocessors, controllers, or test equipment. The AD7828 belongs to the flash-converter ADC category and sits within the broader hierarchy of data-converter ICs, analog-to-digital converters, and semiconductor signal-processing devices. Its multiplexed architecture reduces the number of internal converter cores by time-sharing one converter across eight analog input channels.
The principal advantages of the AD7828KN include eight multiplexed inputs, 10 kHz full-scale signal handling on every channel, 157 mV per microsecond track-and-hold slew rate, and a specified conversion error of 1/2 LSB. A standard parallel microprocessor interface uses Chip Select and Read signals to initiate conversion and retrieve data from three-state outputs. The device also operates from one +5 V supply and consumes approximately 50 mW.
Internally, the AD7828 uses a half-flash conversion technique. When CS and RD go low, the input switches close and the selected channel connects to the most significant and least significant comparators. The separate analog and digital sections are referenced to the external +5 V reference, allowing the measurement scale to be established with a precise external reference. The parallel outputs simplify interfacing with older microprocessor and programmable-logic systems.
Typical applications include multichannel process monitoring, industrial control loops, laboratory instrumentation, multiplexed sensor acquisition, industrial data logging, and embedded measurement systems. Eight channels reduce the number of physical converter inputs, while the 50 kSPS aggregate throughput supports rapidly scanned analog systems. The 0 V to +5 V input range also aligns with conventional industrial signal conditioning.
The primary design consideration is reference and interface stability. Place the external reference and supply bypass capacitors close to their pins, keep analog and digital return currents separated, and account for the acquisition and conversion interval when scheduling successive channel reads. Because the AD7828 is not recommended for new designs, engineers should also consider its lifecycle status before starting a long-lived production program.
This product page organizes the AD7828KN conversion rate, channel architecture, input range, power characteristics, package information, lifecycle status, and procurement data into an engineering-focused reference. It also distinguishes the available drop-in alternatives by package, channel count, resolution, conversion speed, and qualification requirements so replacement decisions can be made against the original circuit constraints.
Alternativas drop-in para AD7828KN — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
AD7828KNZ
✅ Drop-In📋 Alternativa de referência (fora do catálogo)
AD7828AR
✅ Drop-In ⚠️ Especificações não verificadas📋 Alternativa de referência (fora do catálogo)
AD7828BR
✅ Drop-In ⚠️ Especificações não verificadasConsulte o preço
Ver ficha técnica →AD7828BRZ
✅ Drop-In ⚠️ Especificações não verificadas📋 Alternativa de referência (fora do catálogo)
MX7828KN+
✅ Drop-In📋 Alternativa de referência (fora do catálogo)
AD7828KN Classificações máximas e características elétricas
| Converter Type | Flash ADC |
| Resolução | 8 bit |
| Number of Analog Input Channels | 8 channels |
| Conversion Time per Channel | 2.5 microseconds |
| Conversion Rate | 50 kSPS |
| Input Architecture | 8 multiplexed analog inputs |
| Analog Input Range | 0 V to +5 V |
| Tensão de alimentação | +5 V |
| External Reference Voltage | +5 V |
| Full-Scale Signal Handling | 10 kHz on each channel |
| Track-and-Hold Slew Rate | 157 mV per microsecond |
| Conversion Error | 1/2 LSB |
| Power Consumption | 50 mW |
| Track-and-Hold Function | Built-in |
| Microprocessor Interface | Parallel Chip Select and Read interface |
| Output Interface | Three-state parallel data outputs |
| Encapsulamento | PDIP-28 |
| Tipo de montagem | Through-hole |
| Status RoHS | Compliant |
| Status do ciclo de vida | Not recommended for new designs |
Guia de Configuração de Pinos do AD7828KN pdip-28
Configuração de pinos para AD7828KN (pacote pdip-28). Este componente analógico possui pinos de entrada, saída e alimentação. Consulte o datasheet do fabricante para configurações de offset null, compensação e pino de enable. Ideal para circuitos de condicionamento de sinal e amplificadores.
Nenhum dado detalhado de pinagem disponível para AD7828KN.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
AD7828KN é adequado para 6 aplicaçãos: Multichannel Process Monitoring, Laboratory Data Acquisition, Industrial Sensor Multiplexing, Embedded Control Measurements, Automated Test Equipment, Portable Diagnostic Equipment.
Multichannel Process Monitoring
The AD7828KN suits process-monitoring systems that must scan multiple 0 V to +5 V sensor outputs through one converter. Eight multiplexed inputs reduce component count while retaining a 50 kSPS aggregate conversion rate and 2.5-microseconds conversion time per channel. The built-in track-and-hold function supports acquisition of full-scale signals up to 10 kHz, provided each source has sufficiently low impedance. Use current-to-voltage or voltage-divider conditioning to keep every channel inside the input range, and isolate analog returns from digital switching currents to preserve the specified 1/2 LSB conversion-error class.
Recomendado
Laboratory Data Acquisition
The AD7828KN can serve as the analog front end of a laboratory measurement system requiring eight sampled inputs and direct digital access. Its 50 kSPS rate provides 20 microseconds per complete eight-channel scan, while the parallel CS/RD interface allows a microprocessor or programmable-logic device to control channel acquisition without serial-clock overhead. The external +5 V reference is useful when measurement scale must be traceable to a stable source. For bench instruments, place reference and bypass components near the device, use shielded analog routing, and calibrate channel offset and full-scale error if performance must exceed the basic 1/2 LSB specification.
Recomendado
Industrial Sensor Multiplexing
The AD7828KN fits industrial sensor multiplexing when several transducers produce voltages in the 0 V to +5 V range and measurements must be updated quickly. Eight inputs are selected through the ADC's multiplexer, and the 2.5-microseconds channel conversion supports rapid sequential sampling. The track-and-hold network has a specified 157 mV per microsecond slew rate, making it important to keep acquisition times and source impedances compatible with changing signals. Add buffering where sensor outputs are high impedance, protect inputs from industrial transients, and route the reference through a low-noise path to avoid converting supply noise into measurement error.
Recomendado
Embedded Control Measurements
The AD7828KN is suitable for embedded controllers that must monitor eight analog conditions using a simple parallel bus. CS and RD provide straightforward conversion control, while the three-state outputs can share processor bus lines when the interface is correctly managed. A complete eight-channel sampling operation fits within the 50 kSPS performance class, allowing the controller to measure plant variables without dedicating eight separate converter packages. The single +5 V supply arrangement simplifies system partitioning, but the external reference still requires careful bypassing and grounding. Confirm output timing and bus contention requirements directly from the manufacturer datasheet before finalizing the processor interface.
Recomendado
Automated Test Equipment
The AD7828KN can be incorporated into automated test equipment that evaluates eight low-level analog nodes against digital limits. Its 50 kSPS rate allows rapid measurements during fixture scanning, and the 0 V to +5 V input range accommodates outputs from common test boards after attenuation. The parallel interface is useful in older test controllers that lack high-speed serial ADC resources. To preserve measurement repeatability, use a stable external +5 V reference, separate analog input routing from digital control traces, and calibrate offset, gain, and channel-to-channel mismatch. The track-and-hold acquisition interval must also be included in the measurement timing budget.
Recomendado
Portable Diagnostic Equipment
The AD7828KN can support portable diagnostic instruments that acquire several analog measurements under a constrained supply budget. Its approximately 50 mW power consumption and single +5 V operating supply are suitable for compact measurement hardware, while eight inputs reduce connector and converter requirements. The 8-bit resolution is best suited to status indicators, coarse thresholds, waveform envelopes, and supervisory measurements rather than high-fidelity diagnostics. Use low-power buffering where necessary, place bypass capacitors near the supply and reference pins, and account for the NRND lifecycle status when planning a new product. Existing qualified products can evaluate lifecycle continuity through the Request a Quote form.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para AD7828KN — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | AD7828KNZ | AD7828AR | AD7828BR | AD7828BRZ | MX7828KN+ |
|---|---|---|---|---|---|---|
| Package | PDIP-28 | PDIP-28 | PDIP-28 | PDIP-28 | PDIP-28 | DIP-28 |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Maxim Integrated |
| Resolution | 8 bit | 8 bit | 8 bit | 8 bit | 8 bit | 8 bit |
| Number of Inputs | 8 channels | 8 inputs | 8 channels | 8 channels | 8 channels | 8 inputs |
| Conversion Rate | 50 kSPS | 50 kSPS | 50 kSPS | 50 kSPS | 50 kSPS | 50 kSPS |
Principais diferenciais
- Eight-channel integration in a through-hole package (vs AD7824KN)
- Documented 50 kSPS conversion rate (vs MX7828KN+)
- Built-in track-and-hold across all channels (vs AD7828AR)
Notas de projeto
Separate analog input traces from digital control and data lines to minimize conversion error from switching coupling. Route each analog channel with the shortest practical path from its source, avoid sharing narrow traces with high-current outputs, and maintain a continuous ground reference beneath the device. The external +5 V reference and its bypass capacitor should be placed close to the relevant pins so reference noise does not modulate the measured full-scale range.
Use a +5 V supply and external +5 V reference arrangement consistent with the manufacturer specifications, and decouple the supply near the IC with the capacitance and placement prescribed by the datasheet. Verify the source impedance and acquisition interval for every multiplexed channel. High-impedance sensors may require buffers because the track-and-hold input must charge through the selected multiplexer path within the available acquisition time.
Do not treat a matching 28-pin package as proof that every AD7828-family variant is interchangeable. Confirm pin names, control polarity, data-bus behavior, reference configuration, conversion timing, output coding, temperature grade, and acquisition requirements. In particular, ceramic CDIP variants and grade-coded PDIP versions must not be installed where the exact plastic PDIP-28 footprint and qualification conditions are required.
Informações de conformidade
RoHS compliance is identified in a component listing. RoHS compliance does not by itself establish REACH, halogen-free, lead-free, conflict-minerals, or automotive qualification status.