AD7880CQ - 12-Bit 66 kSPS ADC | Analog Devices
N.º da peça: AD7880CQ ✓ AtivoAD7880CQ Visão geral
An ADC is a data-acquisition component that converts a continuously varying analog voltage into a numeric value for processing by a microcontroller, digital signal processor, or industrial controller. The AD7880 belongs to the sampling ADC family and sits within the broader signal-chain hierarchy of sensor input, analog conditioning, quantization, digital conversion, and data processing. Its parallel interface makes it especially appropriate for designs that require rapid conversion results without using a serial data link.
The AD7880 uses a 3 µs track-and-hold acquisition stage followed by a 12 µs successive-approximation conversion stage. Its internal resistor network supports both unipolar and bipolar input signals, reducing the need for external input-range switching circuitry. The converter also includes a power-save feature for systems that do not require continuous sampling. According to the Analog Devices AD7880 product information, the device is fabricated using Linear Compatible CMOS, or LC2MOS, a mixed process combining precision bipolar circuitry with low-power CMOS logic.
The AD7880CQ is offered in a 24-pin, 0.3-inch-wide ceramic dual-in-line package suitable for through-hole industrial and instrumentation assemblies. A small 24-lead SOIC version is also described for the AD7880 family, but it is a different package and is therefore not a direct board-level substitute for AD7880CQ. The AD7880CQ ordering code identifies the ceramic package option used in the target product record, while individual operating-temperature and screening details should be checked against the ordering information in the manufacturer datasheet before production release.
Typical uses include industrial process-control instrumentation, precision measurement systems, data-acquisition equipment, and embedded monitoring designs. The 66 kSPS conversion rate allows the converter to sample rapidly changing control or diagnostic signals, while the parallel output can feed a processor bus without requiring a high-speed serial transceiver. Input conditioning remains essential because the converter does not replace filtering, scaling, reference stabilization, or protection ahead of the analog input.
For implementation, use the manufacturer-recommended input and reference bypassing directly at the appropriate pins, and route analog and digital return currents carefully to minimize conversion disturbance. Because AD7880CQ is a through-hole ceramic DIP, pay particular attention to socket or solder-joint alignment and thermal rise across the 24 leads. Verify the complete pin description and analog input range against the current Analog Devices datasheet before assigning signals.
This product record combines the manufacturer’s functional description with package, interface, resolution, speed, and sourcing details. It also adds application-oriented implementation guidance, parameter comparisons, and a qualified replacement assessment, helping engineers move from the AD7880CQ datasheet to an implementable acquisition circuit without relying on packaging-only substitutions.
Alternativas drop-in para AD7880CQ — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Variantes desta série
Modelos da mesma série compatíveis como drop-in com AD7880CQ (mesmo formato e footprint) — diferindo em Package, Supply Voltage, Converter Architecture, Power-Save Feature.
AD7880BQ
✅ Drop-InConsulte o preço
Ver ficha técnica →AD7880CQ Classificações máximas e características elétricas
| Resolução | 12 bits |
| Conversion Rate | 66 kSPS |
| Converter Architecture | Successive approximation |
| Number of Channels | 1 channel |
| Input Type | Unipolar and bipolar analog input |
| Tensão de alimentação | Single +5 V |
| Track-and-Hold Acquisition Time | 3 µs |
| Successive-Approximation Conversion Time | 12 µs |
| Digital Output Interface | Parallel |
| Process Technology | LC2MOS mixed bipolar-CMOS process |
| Power-Save Feature | Included |
| Encapsulamento | 24-pin ceramic dual-in-line package, 0.3 inch wide |
| Terminal Count | 24 terminals |
| Tipo de montagem | Through-hole |
| Operating Temperature Grade | Industrial |
Guia de Configuração de Pinos do AD7880CQ 24-pin ceramic dual-in-line package, 0.3 inch wide
Configuração de pinos para AD7880CQ (pacote 24-pin ceramic dual-in-line package, 0.3 inch wide). Este componente analógico possui pinos de entrada, saída e alimentação. Consulte o datasheet do fabricante para configurações de offset null, compensação e pino de enable. Ideal para circuitos de condicionamento de sinal e amplificadores.
Nenhum dado detalhado de pinagem disponível para AD7880CQ.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
AD7880CQ é adequado para 6 aplicaçãos: Industrial Process-Control Measurement, Precision Data-Acquisition Systems, Sensor Signal Conditioning, Power-Quality Monitoring, Laboratory Instrumentation, Embedded Monitoring and Diagnostics.
Industrial Process-Control Measurement
The AD7880CQ suits industrial process-control loops that acquire a conditioned analog measurement and transfer the result to digital control logic. Its 66 kSPS conversion rate provides a 12-bit successive-approximation result with a 3 µs track-and-hold interval and 12 µs conversion interval. The parallel interface reduces wiring complexity when connecting the converter to a microprocessor or digital controller. The design must limit source impedance, preserve settling time, and provide stable reference and bypass connections according to the manufacturer guidelines.
Recomendado
Precision Data-Acquisition Systems
The AD7880CQ is useful in a parallel-output data-acquisition system requiring 12-bit measurements at up to 66 kSPS. Its successive-approximation architecture converts each acquired sample in 12 µs after the 3 µs tracking interval, while the parallel interface presents the digital code directly to acquisition logic. For instrument-quality results, use a buffered sensor front end, low-noise reference arrangement, and grounded return paths that keep digital switching noise away from the converter input.
Recomendado
Sensor Signal Conditioning
The AD7880CQ can digitize conditioned outputs from pressure, temperature, position, and current sensors when the sensor signal falls within an available unipolar or bipolar input range. The internal resistor network supports both polarities, which can simplify analog range planning. A 66 kSPS conversion rate allows repeated measurements for monitoring and control. Input protection, anti-alias filtering, source-impedance limits, and acquisition-time budgeting remain essential; the converter does not directly accept arbitrary high-impedance sensor outputs without suitable buffering.
Recomendado
Power-Quality Monitoring
The AD7880CQ can serve as the sampling element in a monitoring subsystem that periodically captures a conditioned voltage or current waveform. Its 66 kSPS rate and 12-bit resolution are appropriate for supervisory measurements where higher-rate waveform capture is not required. The converter’s parallel output allows sampled data to be transferred efficiently into a digital monitor. Front-end scaling must preserve headroom, and acquisition timing must be coordinated so that the 3 µs tracking and 12 µs conversion intervals are included in the sampling schedule.
Recomendado
Laboratory Instrumentation
The AD7880CQ is appropriate for laboratory measurement equipment in which a 12-bit result and a 66 kSPS sampling rate are sufficient. The single +5 V supply simplifies analog power planning, and the parallel interface can connect to a controller, display pipeline, or measurement FPGA through appropriate bus isolation. The ceramic DIP package supports robust through-hole assembly, although care is needed around socket contact resistance and thermal rise. Calibration should account for reference accuracy, input conditioning, and board-level offset and gain behavior.
Recomendado
Embedded Monitoring and Diagnostics
The AD7880CQ can digitize slow or medium-speed diagnostic channels in embedded equipment where a compact parallel ADC simplifies connection to a local processor. The converter supports both unipolar and bipolar conditioned signals and includes a power-save feature for systems that sample intermittently. Because the package uses 24 through-hole terminals, it is particularly suitable for systems assembled with sockets or leaded components. Firmware should use the converter’s specified acquisition and conversion timing rather than treating the maximum sampling rate as an unrestricted continuous-loop rate.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para AD7880CQ — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | AD7880BQ |
|---|---|---|
| Package | 24-pin CDIP | 24-pin CDIP |
| Brand | Analog Devices | Analog Devices |
| Resolution | 12 bits | 12 bits |
| Conversion Rate | 66 kSPS | 66 kSPS |
| Converter Architecture | Successive approximation | Successive approximation |
| Supply Voltage | Single +5 V | Single +5 V |
| Track-and-Hold Time | 3 µs | 3 µs |
| Conversion Time | 12 µs | 12 µs |
| Input Range Support | Unipolar and bipolar | Unipolar and bipolar |
| Digital Interface | Parallel | Parallel |
| Number of Channels | 1 channel | 1 channel |
| Power-Save Feature | Included | Included |
Principais diferenciais
- Direct same-package replacement path (vs AD7880BQ)
- Single-supply operation (vs AD7880BQ)
- Parallel acquisition interface (vs AD7880BQ)
- Bipolar and unipolar input support (vs AD7880BQ)
Notas de projeto
Treat the analog input and reference as precision nodes. Keep the acquisition path short, use the input impedance and acquisition-time limits in the AD7880 datasheet, and place the recommended bypass capacitors adjacent to their pins. Route the 12-bit parallel outputs away from the analog input and reference traces, and provide a direct return path for digital current so that switching activity does not modulate the conversion reference.
Do not treat the stated 66 kSPS rate as permission to omit acquisition timing. Each conversion includes a 3 µs track-and-hold interval and a 12 µs successive-approximation interval. The control logic must also observe conversion-start, busy, and data-valid behavior exactly as described by Analog Devices. Sampling faster than the source can settle can create inaccurate codes that appear to be ADC resolution or reference problems.
Design the 24-pin through-hole footprint from the exact ceramic-DIP mechanical drawing rather than a generic DIP footprint. Confirm pin-1 orientation, row spacing, solder-hole diameter, and ceramic-package body dimensions. If a socket is used, verify contact reliability and consider cleaning or replacement because contact resistance and oxidation can affect sensitive analog measurements in laboratory or industrial equipment.
Decouple the single +5 V supply locally and keep its return current separate from sensitive analog returns where the board layout permits. The converter also includes a power-save feature, but intermittent operation must be coordinated with the analog source so that the input settles before each acquisition. Verify the supply tolerance, absolute maximum ratings, and power sequencing requirements in the manufacturer document before energizing the assembled circuit.
Informações de conformidade
The manufacturer product description identifies the technology, package family, resolution, conversion architecture, supply voltage, and interface, but it does not state the requested compliance or material-category results for this exact ordering code.