Cirrus Logic Inc.

CS5451-BS - 16-Bit 6-Channel Sigma-Delta ADC | Cirrus Logic

N.º da peça: CS5451-BS ✓ Ativo
2.7 V to 3.5 V Vdss 28-pin SSOP Package
MOQ: 1 |

CS5451-BS Visão geral

The Cirrus Logic CS5451-BS is a 16-bit, six-channel sigma-delta analog-to-digital converter designed for power measurement applications. It operates from a 2.7 V to 3.5 V supply, supports an operating temperature range of -40 °C to +85 °C, and is packaged in a 28-pin SSOP. The device combines six sigma-delta conversion channels with digital decimation filtering and a serial interface for transferring measurement data to a host processor.

An analog-to-digital converter, or ADC, converts continuously varying analog voltages into digital values that a microcontroller, DSP, or other digital controller can process. The CS5451 belongs to the sigma-delta ADC family, where oversampling and digital filtering are used to obtain high resolution in narrowband or low-frequency measurement systems. Within the component hierarchy, the CS5451 is a multichannel data-conversion IC and part of the broader ADC/DAC and power-management signal-chain ecosystem.

The CS5451-BS provides six analog input channels and 16-bit resolution in a single package. This integration reduces the number of separate converters required in systems that monitor several power-related signals. Its sigma-delta architecture is particularly useful when the measured signals are relatively slow-changing and require strong rejection of out-of-band noise. The integrated decimation filters help limit the bandwidth presented to the digital interface.

The 28-pin SSOP package supports compact circuit layouts in industrial control, metering, instrumentation, and embedded measurement systems. Because the converter is intended for the power measurement industry, its architecture prioritizes multichannel conversion and digital filtering rather than high-speed waveform capture. The 2.7 V to 3.5 V operating range places it in low-voltage digital and mixed-signal systems, where the host processor and supporting circuits commonly operate from a 3.3 V rail.

Designers should treat the analog inputs, reference circuitry, serial interface, and power connections as separate layout concerns. Place decoupling capacitors close to the supply pins, route analog signals away from switching nodes, and use a clean ground return for the converter. The selected input bandwidth, decimation setting, output data rate, and digital filter configuration should be evaluated together because changing any of them affects the effective measurement bandwidth and conversion timing.

This product page organizes the CS5451-BS electrical identity, package information, sourcing paths, comparison fields, and application guidance into one engineering reference. It also distinguishes verified drop-in alternatives from parts with different packages or insufficient compatibility information, helping designers avoid replacements that require PCB changes or interface redesign.

Alternativas drop-in para CS5451-BS — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

Nenhuma alternativa drop-in disponível para este produto.

Solicitar alternativas

CS5451-BS Classificações máximas e características elétricas

Device Type Six-channel analog-to-digital converter
Architecture Sigma-delta
Resolução 16 bit
Number of Input Channels 6 channels
Supply Voltage Range 2.7 V to 3.5 V
Faixa de temperatura de operação -40 °C to +85 °C
Encapsulamento 28-pin SSOP
Package Type SSOP
Contagem de pinos 28 pins
Tipo de montagem Surface mount
Output Interface Serial interface
Integrated Filters Decimation filters
Target Application Power measurement

Guia de Configuração de Pinos do CS5451-BS ssop

Configuração de pinos para CS5451-BS (pacote ssop). Este componente analógico possui pinos de entrada, saída e alimentação. Consulte o datasheet do fabricante para configurações de offset null, compensação e pino de enable. Ideal para circuitos de condicionamento de sinal e amplificadores.

Diagrama de pinagem do pacote ssop para CS5451-BS

Nenhum dado detalhado de pinagem disponível para CS5451-BS.

Consulte a ficha técnica para a configuração completa dos pinos.

Aplicações típicas

CS5451-BS é adequado para 6 aplicaçãos: Multichannel Energy Metering, Industrial Power Monitoring, Instrumentation Signal Acquisition, Battery-Powered Monitoring, Building Automation Sensor Hub, Embedded Data Acquisition Controller.

⚡

Multichannel Energy Metering

The CS5451-BS is suitable for energy-metering boards that must acquire several analog measurement channels with consistent digital output. Its 6 integrated sigma-delta channels avoid a separate converter for every sensed quantity, while the 16-bit format supports detailed numerical representation of measured values. The decimation filters help reject out-of-band energy before data reaches the host processor. Operate the converter from the documented 2.7 V to 3.5 V range and preserve clean analog routing to achieve repeatable results.

🏭

Industrial Power Monitoring

The CS5451-BS can monitor several slowly changing power-related signals in industrial control equipment. Six 16-bit conversion channels provide a compact way to collect voltage, current, or auxiliary measurements into a common serial data path. Because this is a sigma-delta converter, its strength is narrowband measurement with digital decimation rather than high-speed transient capture. Keep analog traces short, isolate them from switching circuitry, and pair the converter with appropriate sensing and protection components.

🔧

Instrumentation Signal Acquisition

The CS5451-BS fits laboratory and process instrumentation requiring several synchronized or multiplexed measurement inputs. Its integrated decimation filters reduce unwanted frequency content before digital processing, and the serial interface supports connection to a controller or DSP. The 28-pin SSOP footprint helps preserve board area, while the 2.7 V to 3.5 V supply range simplifies integration with 3.3 V logic. Select external resistor networks and input networks according to the full-scale range required by the instrument.

🔋

Battery-Powered Monitoring

The CS5451-BS can support compact battery-powered sensing systems that monitor multiple low-frequency analog quantities. Six integrated channels reduce the amount of separate conversion hardware required, and the low-voltage operating range is compatible with common embedded power rails. Digital filtering makes the device particularly relevant when the measured variables change more slowly than the converter's selected output-data rate. Power-budget calculations should include the converter, reference circuitry, interface activity, and any external sensor loads.

🧩

Building Automation Sensor Hub

The CS5451-BS can serve as the measurement front end in a building-automation or environmental monitoring hub that accepts several sensor outputs. Its 16-bit delta-sigma channels suit temperature, pressure, and other bandwidth-limited analog measurements after suitable conditioning. The serial interface reduces the number of separate data buses in a multichannel design. Maintain separation between sensitive analog traces and digital or switching signals, and select filtering that balances response time against measurement noise.

🖥️

Embedded Data Acquisition Controller

The CS5451-BS is appropriate for embedded data-acquisition controllers requiring six analog inputs and a compact mixed-signal package. Its integrated decimation filters can condition narrowband measurements before data is transferred over the serial interface to a microcontroller or DSP. The 2.7 V to 3.5 V operating range supports common low-voltage system rails, and the -40 °C to +85 °C range covers industrial environments. Validate input settling, filter delay, and output timing as a complete signal chain.

What is the CS5451-BS?
The CS5451-BS is a six-channel, 16-bit sigma-delta analog-to-digital converter from Cirrus Logic. It combines six delta-sigma ADCs, decimation filters, and a serial interface in one 28-pin SSOP package. According to the Cirrus Logic CS5451 datasheet, the device was developed for power-measurement systems, making it suitable for multichannel industrial metering and instrumentation rather than high-speed waveform acquisition.
What are the key specifications of CS5451-BS that engineers should know?
The CS5451-BS provides 16-bit resolution across 6 analog input channels, operates from 2.7 V to 3.5 V, and is specified over -40 °C to +85 °C. Its 28-pin SSOP package includes integrated decimation filters and a serial interface. According to the Cirrus Logic CS5451 datasheet, these characteristics make the device appropriate for power measurement, metering, and multichannel embedded sensing.
What is the operating voltage of CS5451-BS?
The CS5451-BS operates from 2.7 V to 3.5 V. This low-voltage range allows deployment in 3.3 V mixed-signal systems where the ADC, controller, and interface circuitry share a supply architecture. According to the Cirrus Logic CS5451 datasheet, designers should maintain the documented supply limits and provide suitable decoupling close to the device supply pins.
How many channels and bits does the CS5451-BS have?
The CS5451-BS has 6 analog input channels and 16-bit resolution. The six delta-sigma conversion channels are integrated with decimation filters and a serial interface in a single 28-pin SSOP package. According to the Cirrus Logic CS5451 datasheet, this multichannel architecture reduces the component count required for power and energy measurement systems.
Where can I find the CS5451-BS datasheet PDF?
The CS5451-BS datasheet PDF is available through the product-data link on this page and through the linked component listings. The manufacturer documentation describes the device as a six-channel delta-sigma ADC for power measurement. Use the Cirrus Logic datasheet pin-description table, electrical-characteristics tables, and application information when assigning signals and selecting external components.
Where can I find the CS5451-BS pinout?
The CS5451-BS uses a 28-pin SSOP package, and its complete pin assignments are shown in the Cirrus Logic CS5451 datasheet. Use the pin-description table before assigning analog inputs, digital interface signals, supply connections, grounds, or reference-related connections. The package drawing on this page identifies the physical package, while the manufacturer datasheet remains the authority for individual pin names.
Is the CS5451-BS suitable for industrial power measurement?
The CS5451-BS is suitable for multichannel industrial power measurement because it combines 6 delta-sigma ADC channels, 16-bit resolution, decimation filters, and a serial interface. According to the Cirrus Logic CS5451 datasheet, the device was developed specifically for the power-measurement industry and operates across a -40 °C to +85 °C temperature range.
What is the difference between CS5451-BS and CS5451A-IS?
The CS5451-BS is the 28-pin SSOP ordering configuration identified for the CS5451 family, while CS5451A-IS is identified as a different family variant. A replacement must be checked for package, pinout, electrical limits, interface timing, and functional behavior rather than name similarity alone. The available comparison listing does not establish that CS5451A-IS is a pin-to-pin drop-in replacement.
CS5451-BS vs CS5451A-ISZ - which is better for a new design?
The better choice depends on confirmed package compatibility, interface requirements, lifecycle status, and electrical performance rather than the CS5451-family name alone. CS5451-BS is specified in a 28-pin SSOP, while CS5451A-IS and CS5451A-ISZ require their individual ordering tables to be checked. Use the Cirrus Logic datasheets and current product pages before selecting either device for an existing footprint.
When should I choose CS5451-BS over another multichannel ADC?
Choose the CS5451-BS when the design needs 6 analog channels, 16-bit sigma-delta conversion, integrated decimation filtering, and a 2.7 V to 3.5 V supply in a 28-pin SSOP. The Cirrus Logic CS5451 datasheet identifies power measurement as the target application, making it especially relevant to energy meters, industrial monitoring, and instrumentation with relatively narrow measurement bandwidths.
What can replace the CS5451-BS?
A valid replacement for the CS5451-BS must match the 28-pin SSOP footprint, provide equivalent pin assignments, satisfy the analog and digital interface requirements, and remain within the intended supply and temperature limits. No confirmed drop-in replacement is established by the available technical references, so alternative MPNs should be treated as redesign candidates until their manufacturer documentation proves compatibility.
Is the CS5451-BS the same as CS5451A-ISZ?
No, the CS5451-BS and CS5451A-ISZ cannot be treated as identical solely because their names are similar. The CS5451-BS is listed in a 28-pin SSOP package, while the ISZ suffix on CS5451A-ISZ ordinarily denotes a different package option. Confirm the exact package dimensions, pinout, electrical ratings, and lifecycle status in the manufacturer documentation before considering a substitution.
Is the CS5451-BS in stock?
Current stock status should be confirmed through the Request a Quote form on this page because inventory can change independently of product documentation. The component is listed by multiple distributors as in stock or orderable, but the latest lot count, manufacturer inventory, and shipment timing should be requested for the exact CS5451-BS ordering configuration before committing a production schedule.
What is the price of CS5451-BS?
Use the Request a Quote form on this page for the current CS5451-BS price, minimum order quantity, and volume-break availability. The only published figure located is a starting-price statement rather than an exact quantity-break table for this MPN, so it is not used as a contract price. The quotation form provides a current answer tied to the requested quantity and supply conditions.
What is the lead time for CS5451-BS?
Request the current lead time through the Request a Quote form on this page. Lead time depends on inventory, order quantity, package configuration, and replenishment conditions, so a general availability statement cannot establish a production schedule. The CS5451-BS is listed by multiple distributors as orderable, but the quotation response should confirm the current delivery commitment.
Where can I buy CS5451-BS online?
Use the Request a Quote form on this page to request CS5451-BS pricing, stock, minimum order quantity, and lead time for the exact 28-pin SSOP device. This route avoids selecting an electrically different family variant or a package code that does not match the target PCB. A direct supplier confirmation is recommended before placing a production order.

Dados de referência de engenharia para CS5451-BS — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose the CS5451-BS when the design requires six low-bandwidth analog measurements, 16-bit sigma-delta conversion, and a compact 28-pin SSOP implementation on a 2.7 V to 3.5 V supply. It is particularly well aligned with power meters, industrial monitoring systems, and instrumentation where decimation filtering is useful. Do not select it for high-speed waveform capture or applications requiring inputs beyond its documented analog range. No confirmed drop-in replacement is established, so CS5451A-IS and CS5451A-ISZ should be selected only after checking their package, pinout, reference voltage, input range, serial timing, and digital filter behavior. If the board is already designed around the CS5451-BS, verify the exact ordering code, connector assignments, grounding, decoupling, and external input network before production release.

Comparação com alternativas

Parâmetro Este produto
Package 28-pin SSOP
Brand Cirrus Logic
Resolution 16 bit
Input Channels 6 channels
Architecture Sigma-delta
Supply Voltage Range 2.7 V to 3.5 V
Operating Temperature -40 °C to +85 °C
Target Application Power measurement
Integrated Decimation Filters Yes
Output Interface Serial

Principais diferenciais

  • Six integrated measurement channels (vs Discrete single-channel ADC arrangements)
  • Digital filtering within the converter (vs Unfiltered or externally filtered single-channel ADCs)
  • Power-measurement-oriented integration (vs General-purpose high-speed ADC families)

Notas de projeto

Separate the analog and digital return paths as far as practical. Keep the six analog input routes short, avoid running them beneath switching nodes or high-current traces, and place input-network components close to their associated pins. The manufacturer datasheet's application information should guide the reference and analog-input layout. A clean analog section is especially important because any coupling from the power stage can appear as measurement error after digital filtering.

Place the device's supply-decoupling capacitors at the corresponding power pins and keep their ground connections short. The CS5451-BS operates from 2.7 V to 3.5 V, so rail tolerance and transient margin must be checked across temperature and load. Verify that the reference and analog-sensing circuits do not disturb the digital supply, and avoid routing switching-node currents through the converter's ground reference.

Select the serial-interface clock rate and output-data timing together with the converter's filtering configuration. Confirm that the host controller can service the selected transfer rate without data loss, and account for filter settling time after changing operating conditions. The serial lines should be routed away from analog inputs, with return paths arranged to minimize coupling into the measurement channels.

Do not select a similarly named family member as a direct substitute without checking its package code, pinout, analog input range, reference requirements, serial protocol, and timing. The CS5451A-IS and CS5451A-ISZ listings identify family variants, but the available technical references do not establish pin-to-pin compatibility with the 28-pin CS5451-BS. Treat any such choice as a redesign until the manufacturer documentation confirms every interface detail.

Informações de conformidade

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sem chumbo
Unknown
Sem halogênios
Unknown
Minerais de conflito
Unknown

No specific RoHS, REACH, lead-free, halogen-free, or conflict-minerals declaration is included in the available product information. The device is an industrial and commercial mixed-signal ADC rather than an automotive-qualified AEC-Q100 product.

Dados verificados em: 2026-11-05 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

CS5451-BS datasheet CS5451-BS pinout CS5451-BS datasheet pdf CS5451-BS equivalent CS5451-BS replacement CS5451-BS cross reference CS5451-BS footprint CS5451-BS price CS5451-BS stock Cirrus Logic CS5451-BS CS5451-BS vs CS5451A-ISZ CS5451 28-SSOP power measurement ADC

Componentes & termos relacionados

Cirrus Logic CS5451-BS CS5451A-IS CS5451A-ISZ analog-to-digital converter ADC sigma-delta ADC delta-sigma converter power measurement 16-bit resolution six-channel ADC decimation filter serial interface 28-pin SSOP SSOP surface-mount package semiconductor integrated circuit mixed-signal IC 2.7 V to 3.5 V supply industrial instrumentation energy metering RoHS REACH
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue
Ver detalhes da RFQ