ICS553MIT - 1:4 200MHz Low-Skew Clock Buffer | Renesas
N.º da peça: ICS553MIT ✓ AtivoICS553MIT Visão geral
A clock fanout buffer is a clock-and-timing integrated circuit that regenerates and distributes one incoming clock signal across multiple outputs. Its place in the hierarchy is clock buffer, then clock distribution device, then clock-and-timing IC, and finally semiconductor. Fanout buffers are used where a source clock must drive several destinations while limiting loading, propagation variation, and signal degradation across a larger system.
The ICS553MIT is identified as a low-skew, 1-to-4 clock buffer. Its four-output arrangement gives a processor, memory interface, communications circuit, or test instrument multiple usable clock outputs from one source. Operation up to 200 MHz makes it applicable to clock trees operating below that maximum frequency, while its 2.375 V to 5.25 V supply range supports common low-voltage digital systems.
The CMOS input and CMOS outputs place the device in the logic and clock-and-timing categories. CMOS interfaces are suitable for modern digital systems because they support rail-to-rail operation in many designs and combine useful noise and power characteristics. Exact propagation delay, output-to-output skew, input-output skew, rise time, fall time, and current-consumption figures should be taken from the manufacturer datasheet before setting timing margins.
Typical uses include distributing a reference clock among four digital loads, buffering a source oscillator before it reaches multiple logic blocks, and supporting compact communications, control, or instrumentation equipment. In each case, trace lengths should be arranged so that all four destinations receive clocks within the timing budget established for the system.
The primary design consideration is timing margin across all four outputs rather than only the source-to-output path. Keep the input and output connections short, maintain a consistent return path, and place decoupling close to the supply pins. Account for the difference between edge arrival at the input and edge arrival at each load when defining setup and hold requirements.
This product page combines the manufacturer part characteristics, source availability, pin-compatible alternatives, comparison criteria, and practical clock-distribution guidance. It is intended to accelerate component identification while keeping the final timing, layout, and qualification decisions with the system designer.
Alternativas drop-in para ICS553MIT — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
553MLF
✅ Drop-In📋 Alternativa de referência (fora do catálogo)
NB3L553DR2G
✅ Drop-In📋 Alternativa de referência (fora do catálogo)
ICS553MIT Especificações
| Product Type | Clock Fanout Buffer (Distribution) IC |
| Fanout Ratio | 1:4 |
| Frequência máxima de clock | 200 MHz |
| Supply Voltage Range | 2.375 V to 5.25 V |
| Input Logic Type | CMOS |
| Output Logic Type | CMOS |
| Package Type | 8-SOIC |
| Package Width | 0.154 in (3.90 mm) |
| Tipo de montagem | Surface mount |
| Device Family | ICS ClockBlocks |
| Skew Characteristics | Low-skew |
| Status RoHS | Non-compliant |
Guia de Configuração de Pinos do ICS553MIT 0.154 in (3.90 mm)
Configuração de pinos para ICS553MIT (pacote 0.154 in (3.90 mm)). A numeração dos pinos, funções e diagramas de conexão estão definidos no datasheet do fabricante. Consulte-o para o footprint exato e diretrizes de soldagem.
Nenhum dado detalhado de pinagem disponível para ICS553MIT.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
ICS553MIT é adequado para 6 aplicaçãos: Digital Processor Clock Distribution, Communications Equipment Clock Tree, Oscillator and Crystal Reference Buffering, Industrial Control and Automation Logic, Test and Measurement Equipment, Data Converter and Memory Interface Clocks.
Digital Processor Clock Distribution
ICS553MIT is suitable for distributing one system clock to four digital destinations when the design must remain within a 200 MHz maximum frequency. Place the buffer close to the clock source so the single input sees a clean edge, then route each regenerated output to a separate logic block. Its four-output CMOS architecture avoids asking the source to drive four loads directly. Because this is a low-skew device, evaluate the combined output-to-output skew, propagation delay, trace length, and receiver setup-and-hold requirements. The 2.375 V to 5.25 V operating range also supports common low-voltage digital rails.
Recomendado
Communications Equipment Clock Tree
In communications equipment, a single reference clock often must reach several serializers, transceivers, or digital controllers. ICS553MIT provides a 1:4 fanout function, allowing one clock source to feed four separate destinations while reducing source loading. Its maximum specified frequency of 200 MHz covers many moderate-speed digital interfaces. The designer should match trace geometry among the four branches where practical and include output-to-output skew in the downstream timing budget. The CMOS input and outputs align with common low-voltage digital logic, while the 2.375 V to 5.25 V supply range supports multiple rail options.
Recomendado
Oscillator and Crystal Reference Buffering
ICS553MIT can buffer an oscillator or crystal-derived reference clock before it reaches four destination circuits. Regenerating the signal at the buffer provides a controlled fanout point rather than connecting several loads directly to a sensitive oscillator output. The 1:4 topology is useful where a processor, memory interface, converter, and communication block require the same reference. Keep the oscillator-to-buffer path short and provide a continuous ground plane to reduce susceptibility to noise. Check the buffer's input thresholds and timing characteristics against the oscillator amplitude and edge rate before committing the circuit, especially when operating near the 200 MHz frequency limit.
Recomendado
Industrial Control and Automation Logic
Industrial control assemblies often distribute a common timing or synchronization signal among control, interface, and monitoring blocks. ICS553MIT offers four CMOS clock outputs from one input, simplifying fanout without requiring multiple unrelated buffers. Its 2.375 V to 5.25 V supply range suits many embedded control systems. The critical design task is preserving timing correlation at all four receivers, particularly when loads are separated by different PCB trace lengths or cable delays. Use the datasheet's propagation and skew limits to establish the system budget, and verify the operating-temperature grade required by the equipment before production release.
Recomendado
Test and Measurement Equipment
ICS553MIT can distribute a reference clock to four acquisition, conversion, or triggering sections of compact test equipment. The one-input, four-output arrangement helps each subsystem receive a regenerated clock while keeping the source connection simple. A maximum frequency of 200 MHz makes the device relevant for moderate-speed digital instrumentation and automated test systems. Engineers should account for clock-to-clock correlation, loading, and receiver timing margin at every output rather than evaluating only the source edge. The 8-SOIC package also supports conventional surface-mount assembly, although the exposed thermal behavior and temperature grade must be checked for the enclosure environment.
Recomendado
Data Converter and Memory Interface Clocks
ICS553MIT is applicable where a memory controller, data converter, and related digital logic need separate copies of one interface clock. Buffering the source reduces fanout burden and provides four regenerated outputs, while the low-skew design supports timing-sensitive systems. The buffer must operate below 200 MHz and remain within its 2.375 V to 5.25 V supply range. Match output rise and fall characteristics to the receiving devices and review the converter or memory interface's required clock duty cycle, jitter, and setup-and-hold limits. PCB branches should use consistent geometry and an uninterrupted return path to prevent one output from carrying substantially more noise or edge distortion than the others.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para ICS553MIT — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | 553MLF | NB3L553DR2G |
|---|---|---|---|
| Package | 8-SOIC | 8-SOIC | 8-SOIC |
| Brand | Renesas Electronics | Renesas Electronics | onsemi |
| Product Type | Clock Fanout Buffer (Distribution) IC | Low-skew 1-to-4 clock buffer | Low-skew 1-to-4 clock fanout buffer |
| Fanout Ratio | 1:4 | 1:4 | 1:4 |
| Input Logic | CMOS | CMOS | CMOS |
| Output Logic | CMOS | CMOS | CMOS |
| Skew Class | Low-skew | Low-skew | Low-skew |
Principais diferenciais
- Established Renesas ICS553 family positioning (vs NB3L553DR2G)
- Same-family option can simplify ordering review (vs 553MLF)
- Four-output regeneration in a compact package (vs NB3L553DR2G)
Notas de projeto
Treat all four outputs as part of one timing channel. Compare propagation delay and output-to-output skew at the operating voltage and temperature, then include receiver setup and hold requirements in the clock budget. Keep branches electrically similar where practical, but prioritize the datasheet's skew limit over merely equalizing physical length when return paths or loading differ.
Place the ICS553MIT close to the clock source and route each output directly toward its destination. Use a continuous ground reference, avoid crossing noisy return paths, and minimize stubs and test-point capacitance. A short input route helps the source drive the buffer cleanly, while short output routes reduce trace loss and sensitivity to nearby switching nodes.
Do not assume that every 1-to-4 8-SOIC clock buffer is interchangeable. Before fitting NB3L553DR2G or another candidate, verify input thresholds, output-enable polarity, supply limits, pin assignments, propagation delay, and skew. Also confirm the exact operating-temperature grade and ordering suffix required by the production design.
Decouple the supply close to the device with the capacitance recommended by the manufacturer datasheet and maintain a low-impedance return path. Keep switching-converter and digital-clock traces away from the clock input. The available clock-buffer operating range extends from 2.375 V to 5.25 V, but the supply must remain stable across process, temperature, and load conditions.
Informações de conformidade
The ICS553MIT product listing identifies the component as RoHS non-compliant. No qualification or material-compliance claims beyond that statement were established.