INA105KU/2K5 - Single-Supply Amplifier | Texas Instruments
N.º da peça: INA105KU/2K5 ✓ AtivoINA105KU/2K5 Visão geral
An instrumentation amplifier is a differential amplifier optimized for measuring a small voltage difference between two input nodes. In the signal-chain hierarchy, it sits between sensors and transducers on the input side and precision converters, analog-to-digital converters, or digital-to-analog converters on the output side. Its defining role is to amplify the wanted differential signal while rejecting voltage common to both inputs.
The INA105KU/2K5 supports systems operating from a single positive supply, an arrangement commonly encountered in industrial controls, test equipment, and embedded measurement systems. Single-supply operation simplifies rail distribution, but it also requires careful attention to input and output voltage limits, common-mode range, and the voltage presented to the signal source. The manufacturer datasheet should be used as the controlling reference for those operating limits.
The INA105 architecture provides a practical way to develop gain around one precision signal-conditioning channel rather than a discrete differential amplifier stage. Designers should verify resistor values, feedback configuration, bandwidth, input bias current, output swing, and stability against their actual signal source. These checks determine whether the gain represented by the /2K5 configuration is appropriate for the intended sensor output.
Typical uses include bridge-transducer excitation and measurement, differential sensor conditioning, current-shunt amplification, and conversion of low-level bipolar signals into a single-supply analog range. Industrial acquisition systems can place the device near the sensor, reducing susceptibility to noise introduced by long analog traces. Test and measurement equipment can also use it where the signal exists between two nodes that are not referenced directly to ground.
Layout quality is central to precision performance. Place input resistors and feedback components close to the device, maintain symmetrical input routing, use a quiet ground reference, and decouple the supply pins with the capacitance specified by the manufacturer. Verify that the PCB footprint matches the 8-pin SOIC dimensions and check lead orientation against the package drawing before assembly.
This product record combines the exact ordering information, package-level pinout guidance, application-oriented design context, structured technical parameters, and replacement criteria needed for engineering review. It also distinguishes verified catalog facts from details that must be confirmed in the Texas Instruments datasheet before schematic release or production qualification.
Alternativas drop-in para INA105KU/2K5 — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Variantes desta série
Modelos da mesma série compatíveis como drop-in com INA105KU/2K5 (mesmo formato e footprint) — diferindo em Product Type, Package, Bandwidth.
Nenhuma alternativa drop-in disponível para este produto.
Solicitar alternativasINA105KU/2K5 Classificações máximas e características elétricas
| Product Type | Instrumentation Amplifier |
| Manufacturer | Texas Instruments |
| Orderable Part Number | INA105KU/2K5 |
| Order-Code Gain Configuration | 2K5 |
| Supply Configuration | Single Supply |
| Input Type | Differential |
| Encapsulamento | 8-pin SOIC |
| Tipo de montagem | Surface Mount |
| Status RoHS | unknown |
| REACH Status | unknown |
| Automotive Qualification | unknown |
Configuração de pinos do INA105KU/2K5
| Pino 1 | RG — Gain-setting resistor connection |
| Pino 2 | RG — Gain-setting resistor connection |
| Pino 3 | RE — Reference input |
| Pino 4 | V- — Negative supply or ground connection, depending on the application configuration |
| Pino 5 | RE — Reference input |
| Pino 6 | V+ — Positive supply connection |
| Pino 7 | OUT — Amplified output |
| Pino 8 | NC — Not connected |
Aplicações típicas
INA105KU/2K5 é adequado para 6 aplicaçãos: Bridge Transducer Conditioning, Industrial Pressure Sensor Interface, Current-Shunt Amplification, Precision Data-Acquisition Front End, Portable Battery-Powered Measurement, Test and Measurement Front Panel.
Bridge Transducer Conditioning
INA105KU/2K5 is suited to differential measurement from a resistive bridge when the bridge is operated within the amplifier’s allowable supply and common-mode ranges. The differential input structure reduces the importance of common-mode voltage at the sensor node, while the /2K5 configuration provides the starting point for the required signal gain. Confirm excitation voltage, bridge impedance, input bias current, and output swing in the Texas Instruments datasheet. Place the device near the bridge, keep both input paths short, and avoid routing them beside switching nodes.
Industrial Pressure Sensor Interface
A pressure transducer with a differential output can feed the INA105KU/2K5 for amplification before an ADC or analog measurement block. The single-supply architecture is useful in industrial controllers where negative rails are undesirable, although the sensor’s common-mode voltage must remain inside the device’s operating region. Check the selected gain against sensor sensitivity and full-scale output, then verify the amplifier’s output can reach the ADC input range without clipping. Decoupling and grounded return paths are essential at the transducer connector.
Current-Shunt Amplification
INA105KU/2K5 can condition the small differential voltage generated across a current-sense shunt when its input and output limits meet the operating condition. The differential measurement reduces the effect of voltage shared by the shunt’s two terminals, and the compact 8-pin SOIC supports placement close to the shunt or measurement converter. Verify the shunt’s common-mode voltage, transient excursions, power dissipation, and amplifier bandwidth. Use Kelvin-style routing where the available PCB area allows it to avoid pickup from the supply-current path.
Precision Data-Acquisition Front End
INA105KU/2K5 is appropriate for an analog data-acquisition front end when a sensor produces two correlated nodes rather than a ground-referenced signal. Its differential conditioning role can improve measurement integrity before conversion by an ADC. The design must confirm that the amplifier’s common-mode range covers the sensor output and that the output swing remains compatible with the converter input. Use a quiet supply section, local bypass capacitors, controlled grounding, and input filtering sized against the required measurement bandwidth.
Portable Battery-Powered Measurement
The single-supply architecture of INA105KU/2K5 is useful in portable measurement equipment that cannot easily support positive and negative analog rails. The amplifier can condition a differential sensor output while preserving the system’s battery-powered simplicity. Designers should verify the minimum operating supply, quiescent consumption, output headroom, and ability to power down or disconnect the input when that function is required. A low-noise supply and compact placement near the sensor help avoid wasting battery energy or board area.
Test and Measurement Front Panel
INA105KU/2K5 can serve as the input stage for instrumentation that measures a differential voltage in a single-supply environment. The /2K5 configuration should be checked against the selected input range and bandwidth, while the reference network establishes the output baseline for a unipolar converter. Account for input protection, startup behavior, ground noise, and connector-to-amplifier routing. For laboratory accuracy, verify calibration drift and offset against the actual measurement specification before using the circuit as a precision reference channel.
Dados de referência de engenharia para INA105KU/2K5 — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto |
|---|---|
| Package | 8-pin SOIC |
| Brand | Texas Instruments |
| Product Type | Instrumentation Amplifier |
| Supply Configuration | Single Supply |
| Input Type | Differential |
| Order-Code Configuration | 2K5 |
| Pin Count | 8 pins |
| Mounting Type | Surface Mount |
Principais diferenciais
- Differential signal conditioning in a compact package (vs General-purpose single-ended operational amplifier)
- Single-supply system integration (vs Dual-supply precision amplifier)
- Order-code-specific gain configuration (vs Externally configured instrumentation amplifier)
Notas de projeto
Route the two differential inputs as a matched pair and place their associated resistors close to INA105KU/2K5. Minimize loop area and avoid sharing sensitive return paths with relay, motor, or switching-converter currents. Connect the local bypass capacitor directly between the supply and ground pins, and use the package drawing and pin-description table to confirm orientation before releasing the PCB artwork.
Verify the complete signal path against the INA105KU/2K5 supply-voltage, input common-mode, and output-swing limits. Include startup, sensor faults, and maximum source amplitude rather than checking only nominal values. Use the amplifier output as the indicator of sensor health where practical, and confirm that downstream conversion does not overload the output during transient conditions.
Do not select a replacement solely because it fits an 8-pin SOIC footprint. Gain configuration, reference behavior, common-mode range, supply voltage, bandwidth, offset, and output drive can differ while the PCB remains unchanged. For INA105KU/2K5, review the manufacturer ordering table and electrical characteristics together, and qualify any proposed substitute against the original circuit’s gain and signal-source impedance.
Informações de conformidade
Compliance attributes require confirmation from the current manufacturer product documentation or declaration for the exact ordering code.