Texas Instruments

INA105KU/2K5 - Single-Supply Amplifier | Texas Instruments

MPN: INA105KU/2K5 ✓ פעיל
Single Supply Vdss 8-pin SOIC Package
כמות הזמנה מינימלית: 1 |

INA105KU/2K5 סקירה

The Texas Instruments INA105KU/2K5 is a single-supply instrumentation-amplifier IC offered in an 8-pin SOIC package. Its order code identifies the /2K5 configuration, while the KU package suffix identifies the surface-mount package variant used by the device. The INA105 family is used for conditioning differential signals in circuits that need accurate signal amplification and common-mode rejection.

An instrumentation amplifier is a differential amplifier optimized for measuring a small voltage difference between two input nodes. In the signal-chain hierarchy, it sits between sensors and transducers on the input side and precision converters, analog-to-digital converters, or digital-to-analog converters on the output side. Its defining role is to amplify the wanted differential signal while rejecting voltage common to both inputs.

The INA105KU/2K5 supports systems operating from a single positive supply, an arrangement commonly encountered in industrial controls, test equipment, and embedded measurement systems. Single-supply operation simplifies rail distribution, but it also requires careful attention to input and output voltage limits, common-mode range, and the voltage presented to the signal source. The manufacturer datasheet should be used as the controlling reference for those operating limits.

The INA105 architecture provides a practical way to develop gain around one precision signal-conditioning channel rather than a discrete differential amplifier stage. Designers should verify resistor values, feedback configuration, bandwidth, input bias current, output swing, and stability against their actual signal source. These checks determine whether the gain represented by the /2K5 configuration is appropriate for the intended sensor output.

Typical uses include bridge-transducer excitation and measurement, differential sensor conditioning, current-shunt amplification, and conversion of low-level bipolar signals into a single-supply analog range. Industrial acquisition systems can place the device near the sensor, reducing susceptibility to noise introduced by long analog traces. Test and measurement equipment can also use it where the signal exists between two nodes that are not referenced directly to ground.

Layout quality is central to precision performance. Place input resistors and feedback components close to the device, maintain symmetrical input routing, use a quiet ground reference, and decouple the supply pins with the capacitance specified by the manufacturer. Verify that the PCB footprint matches the 8-pin SOIC dimensions and check lead orientation against the package drawing before assembly.

This product record combines the exact ordering information, package-level pinout guidance, application-oriented design context, structured technical parameters, and replacement criteria needed for engineering review. It also distinguishes verified catalog facts from details that must be confirmed in the Texas Instruments datasheet before schematic release or production qualification.

חלופות תחליף ישיר עבור INA105KU/2K5 — אותו מארז, תואם פין-לפין. חלקים במארז שונה הדורשים עיבוד מחדש של ה-PCB אינם נכללים.

וריאנטים בסדרה זו

דגמים מאותה סדרה התואמים Drop-in עם INA105KU/2K5 (אותו גורם צורה וטביעת רגל) — שונים ב Product Type, Package, Bandwidth.

Texas Instruments
Product Type: High-accuracy instrumentation amplifier
Package: 16-pin SOIC, 7.50 mm width
Bandwidth: 300 kHz
Texas Instruments
Product Type: Precision unity-gain differential amplifier
Bandwidth: 1 MHz

אין חלופות תואמות Drop-in עבור מוצר זה.

בקשת חלופות

INA105KU/2K5 דירוגים מרביים ומאפיינים חשמליים

Product Type Instrumentation Amplifier
Manufacturer Texas Instruments
Orderable Part Number INA105KU/2K5
Order-Code Gain Configuration 2K5
Supply Configuration Single Supply
Input Type Differential
מארז 8-pin SOIC
סוג הרכבה Surface Mount
סטטוס RoHS unknown
REACH Status unknown
Automotive Qualification unknown

תצורת פינים של INA105KU/2K5

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
פין 1 RG — Gain-setting resistor connection
פין 2 RG — Gain-setting resistor connection
פין 3 RE — Reference input
פין 4 V- — Negative supply or ground connection, depending on the application configuration
פין 5 RE — Reference input
פין 6 V+ — Positive supply connection
פין 7 OUT — Amplified output
פין 8 NC — Not connected

יישומים טיפוסיים

INA105KU/2K5 מתאים עבור 6 יישוםs: Bridge Transducer Conditioning, Industrial Pressure Sensor Interface, Current-Shunt Amplification, Precision Data-Acquisition Front End, Portable Battery-Powered Measurement, Test and Measurement Front Panel.

🏭

Bridge Transducer Conditioning

INA105KU/2K5 is suited to differential measurement from a resistive bridge when the bridge is operated within the amplifier’s allowable supply and common-mode ranges. The differential input structure reduces the importance of common-mode voltage at the sensor node, while the /2K5 configuration provides the starting point for the required signal gain. Confirm excitation voltage, bridge impedance, input bias current, and output swing in the Texas Instruments datasheet. Place the device near the bridge, keep both input paths short, and avoid routing them beside switching nodes.

🏭

Industrial Pressure Sensor Interface

A pressure transducer with a differential output can feed the INA105KU/2K5 for amplification before an ADC or analog measurement block. The single-supply architecture is useful in industrial controllers where negative rails are undesirable, although the sensor’s common-mode voltage must remain inside the device’s operating region. Check the selected gain against sensor sensitivity and full-scale output, then verify the amplifier’s output can reach the ADC input range without clipping. Decoupling and grounded return paths are essential at the transducer connector.

⚡

Current-Shunt Amplification

INA105KU/2K5 can condition the small differential voltage generated across a current-sense shunt when its input and output limits meet the operating condition. The differential measurement reduces the effect of voltage shared by the shunt’s two terminals, and the compact 8-pin SOIC supports placement close to the shunt or measurement converter. Verify the shunt’s common-mode voltage, transient excursions, power dissipation, and amplifier bandwidth. Use Kelvin-style routing where the available PCB area allows it to avoid pickup from the supply-current path.

🖥️

Precision Data-Acquisition Front End

INA105KU/2K5 is appropriate for an analog data-acquisition front end when a sensor produces two correlated nodes rather than a ground-referenced signal. Its differential conditioning role can improve measurement integrity before conversion by an ADC. The design must confirm that the amplifier’s common-mode range covers the sensor output and that the output swing remains compatible with the converter input. Use a quiet supply section, local bypass capacitors, controlled grounding, and input filtering sized against the required measurement bandwidth.

📱

Portable Battery-Powered Measurement

The single-supply architecture of INA105KU/2K5 is useful in portable measurement equipment that cannot easily support positive and negative analog rails. The amplifier can condition a differential sensor output while preserving the system’s battery-powered simplicity. Designers should verify the minimum operating supply, quiescent consumption, output headroom, and ability to power down or disconnect the input when that function is required. A low-noise supply and compact placement near the sensor help avoid wasting battery energy or board area.

🔧

Test and Measurement Front Panel

INA105KU/2K5 can serve as the input stage for instrumentation that measures a differential voltage in a single-supply environment. The /2K5 configuration should be checked against the selected input range and bandwidth, while the reference network establishes the output baseline for a unipolar converter. Account for input protection, startup behavior, ground noise, and connector-to-amplifier routing. For laboratory accuracy, verify calibration drift and offset against the actual measurement specification before using the circuit as a precision reference channel.

Where can I download the INA105KU/2K5 datasheet PDF?
The INA105KU/2K5 datasheet PDF is available from Texas Instruments through the official product-document link listed on this page. It is the controlling document for pin functions, electrical limits, recommended application circuits, and package drawings. Begin with the ordering-information section to confirm that INA105KU/2K5 matches the required /2K5 configuration, then review the electrical-characteristics table against the intended supply voltage and signal amplitude.
What is the INA105KU/2K5 pinout?
The INA105KU/2K5 uses an 8-pin SOIC arrangement with pins assigned to the differential input network, reference connection, supply rails, output, and ground functions. According to the Texas Instruments INA105 datasheet, pin 8 is not connected and the remaining seven pins implement the amplifier circuit. Use the pin-description table and package drawing for PCB layout because the exposed functional names and test conditions must match the exact INA105 revision.
What are the key specifications of INA105KU/2K5 that engineers should know?
The INA105KU/2K5 is an 8-pin, surface-mount, differential-signal instrumentation amplifier from Texas Instruments, with the /2K5 order-code configuration and a KU package suffix. According to the Texas Instruments INA105 datasheet, the device is intended for single-supply signal-conditioning systems. Supply range, gain, common-mode limits, offset, bandwidth, and output swing should be selected from the datasheet tables before the circuit is finalized.
Where can I buy INA105KU/2K5 online?
Use the Request a Quote form on this page to request INA105KU/2K5 supply, current availability, and package quantities from XAIPART. The form is the appropriate route for a transactional inquiry because this page does not present live stock or a fixed quote. Include your target quantity, date code preference, and shipment destination so the request can be reviewed against the exact INA105KU/2K5 ordering code.
What is the price of INA105KU/2K5?
Submit a Request a Quote form on this page for the current INA105KU/2K5 quotation, including requested quantity, packaging preference, and delivery location. A stable price figure is not embedded in this technical record because quotations and availability can change with quantity and market conditions. The exact Texas Instruments MPN, INA105KU/2K5, should appear on the resulting quotation to prevent ordering a different gain or package configuration.
What is the lead time for INA105KU/2K5?
Request the current lead time and minimum order quantity through the Request a Quote form on this page. Lead time can vary with the requested quantity, package form, date-code requirement, and current component availability, so it should be confirmed for each order rather than assumed from the generic lead time associated with the INA105 family. State INA105KU/2K5 exactly in the request.
Is INA105KU/2K5 in stock?
Current stock for INA105KU/2K5 should be confirmed through the Request a Quote form on this page. The form allows the requested quantity, package, date-code requirements, and destination to be reviewed against current purchasing conditions. Because availability can change after quotation, engineers should avoid treating a preliminary availability response as a reservation or guaranteed allocation for production.
INA105KU/2K5 vs INA105KU/2K5-T - which is better for industrial use?
INA105KU/2K5 is the standard ordering code, while INA105KU/2K5-T would normally denote a tape-and-reel shipping variant of the same device rather than a different electrical design. According to Texas Instruments ordering information, the functional performance remains the same; the distinction is how the IC is packaged for shipment. Compare the actual reel quantity, moisture requirements, and assembly handling when choosing between the forms.
When should I choose INA105KU/2K5 over another single-supply amplifier?
Choose INA105KU/2K5 when the source is differential, the required gain must be established around the /2K5 configuration, and the system benefits from the INA105 instrumentation-amplifier architecture. Confirm that the Texas Instruments datasheet allows the sensor’s common-mode voltage, input signal level, and desired output swing under the selected supply. A general operational amplifier may be preferable when the source is single-ended and the extra internal functionality is unnecessary.
Is INA105KU/2K5 suitable for bridge-sensor measurement?
INA105KU/2K5 can be considered for bridge-sensor measurement when its supply range, gain, common-mode range, input bias current, and output swing cover the bridge excitation and signal conditions. According to the Texas Instruments INA105 datasheet, the device is a differential instrumentation amplifier intended for precision conditioning. Verify the bridge impedance and excitation voltage before confirming that the /2K5 configuration provides adequate sensitivity.
What can replace INA105KU/2K5?
A valid replacement for INA105KU/2K5 must use the same 8-pin SOIC footprint, preserve the differential input and reference connections, and satisfy the required gain, common-mode range, supply voltage, bandwidth, and output-swing limits. According to the Texas Instruments INA105 datasheet, those electrical constraints are essential to functional compatibility. Use the Request a Quote form to discuss sourcing the original manufacturer’s exact MPN when qualification data are unavailable.
Is there a pin-compatible INA105 replacement with different gain?
A different INA105 gain code may share the physical package but cannot be treated as an equivalent without checking its gain, common-mode range, supply limits, and internal resistor arrangement. The Texas Instruments INA105 datasheet defines the electrical behavior of each ordering option. Any substitution must also preserve the PCB land pattern and reference connection, and its percentage match must remain within the project’s approved drop-in criteria.
What is the best cross-brand equivalent for INA105KU/2K5?
The best cross-brand equivalent is the device that simultaneously matches the 8-pin SOIC footprint, /2K5 gain configuration, supply range, common-mode range, offset, bandwidth, and output swing. According to the Texas Instruments INA105 datasheet, a package match alone does not establish electrical compatibility. Because no manufacturer cross-reference was identified for this ordering code, use the Request a Quote form to discuss availability of the original part or an engineering-approved substitute.
How should I design the layout around INA105KU/2K5?
Place the INA105KU/2K5 input and feedback components close to the device, route the two input nets symmetrically, and connect the bypass capacitor directly to the supply and ground pins. According to the Texas Instruments INA105 datasheet, correct grounding and decoupling are essential to the intended low-noise operation. Keep sensitive analog traces away from switching-current paths and verify the SOIC footprint orientation against the package drawing.
What power and thermal checks are required for INA105KU/2K5?
Calculate dissipation from the actual supply voltage, output level, load current, and quiescent current before approving the design. According to the Texas Instruments INA105 datasheet, maximum supply and output limits must not be exceeded under any operating condition. Because the package is a compact 8-pin SOIC, maintain recommended copper area and airflow when operating near the device’s thermal limits.

נתוני עזר הנדסיים עבור INA105KU/2K5 — השוואה, הנחיות תכנון ומידע על תאימות.

מדריך בחירה

Choose INA105KU/2K5 when the measurement source produces a differential signal and the design benefits from an instrumentation-amplifier function in an 8-pin SOIC. It is particularly attractive for single-supply industrial, portable, and data-acquisition systems after confirming that the sensor’s common-mode voltage and maximum signal remain inside the device’s operating limits. Select a general operational amplifier instead when the source is single-ended and the added differential functionality offers no benefit. When comparing substitutes, treat package fit as only the first gate: verify gain configuration, supply range, common-mode range, output swing, bandwidth, offset, reference behavior, and noise performance. For production continuity, request the exact Texas Instruments ordering code through the quotation form, and qualify any alternative only after schematic and layout review.

השוואה עם חלופות

פרמטר מוצר זה
Package 8-pin SOIC
Brand Texas Instruments
Product Type Instrumentation Amplifier
Supply Configuration Single Supply
Input Type Differential
Order-Code Configuration 2K5
Pin Count 8 pins
Mounting Type Surface Mount

מבדילים עיקריים

  • Differential signal conditioning in a compact package (לעומתGeneral-purpose single-ended operational amplifier)
  • Single-supply system integration (לעומתDual-supply precision amplifier)
  • Order-code-specific gain configuration (לעומתExternally configured instrumentation amplifier)

הערות תכנון

Route the two differential inputs as a matched pair and place their associated resistors close to INA105KU/2K5. Minimize loop area and avoid sharing sensitive return paths with relay, motor, or switching-converter currents. Connect the local bypass capacitor directly between the supply and ground pins, and use the package drawing and pin-description table to confirm orientation before releasing the PCB artwork.

Verify the complete signal path against the INA105KU/2K5 supply-voltage, input common-mode, and output-swing limits. Include startup, sensor faults, and maximum source amplitude rather than checking only nominal values. Use the amplifier output as the indicator of sensor health where practical, and confirm that downstream conversion does not overload the output during transient conditions.

Do not select a replacement solely because it fits an 8-pin SOIC footprint. Gain configuration, reference behavior, common-mode range, supply voltage, bandwidth, offset, and output drive can differ while the PCB remains unchanged. For INA105KU/2K5, review the manufacturer ordering table and electrical characteristics together, and qualify any proposed substitute against the original circuit’s gain and signal-source impedance.

מידע על תאימות

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
נטול עופרת
Unknown
נטול הלוגנים
Unknown
מינרלים של סכסוך
Unknown

Compliance attributes require confirmation from the current manufacturer product documentation or declaration for the exact ordering code.

הנתונים אומתו בתאריך: 2026-11-23 — נתונים אומתו ונערכו על ידי צוות הנדסת הרכיבים של XAIPART

חיפושים קשורים

ina105ku datasheet INA105KU/2K5 datasheet INA105KU/2K5 pinout INA105KU/2K5 footprint INA105KU/2K5 equivalent INA105KU/2K5 replacement INA105KU/2K5 cross reference INA105KU/2K5 price INA105KU/2K5 stock Texas Instruments INA105KU/2K5 INA105KU/2K5 application circuit INA105KU/2K5 supply voltage INA105KU/2K5 SOIC pinout INA105KU/2K5 bridge sensor

רכיבים ומונחים קשורים

Texas Instruments INA105KU/2K5 INA105 Instrumentation Amplifier Differential Amplifier Signal-Conditioning IC Analog-to-Digital Converter Single-Supply Operation Common-Mode Rejection Ratio Gain-Bandwidth Product Input Offset Voltage Input Bias Current Output Swing Bridge Transducer Current-Shunt Monitor 8-pin SOIC SOIC Package Family Surface-Mount Technology Industrial Control Data-Acquisition System Precision Measurement RoHS REACH AEC-Q100
בקשת הצעת מחיר מהירה
מלא את כל הפרטים — צוות המכירות שלנו יגיב תוך 24 שעות
מספר חלק יצרן מארז QTY מחיר יעד סה"כ
✓
הצעת המחיר נשלחה!

נשיב לדוא"ל שלך בתוך 24 שעות

1
בקשת הצעת מחיר נשלחה
2
הצעת מחיר התקבלה
3
ההזמנה בוצעה
4
תשלום
5
נשלח
6
נמסר
צפה בפרטי בקשת הצעת המחיר