Analog Devices

LTC1050CH - 0.5 uV Zero-Drift Op Amp | Analog Devices

N.º da peça: LTC1050CH ✓ Ativo
0.5 uV Vdss 10 pA Id TO-5 metal can Package
MOQ: 1 |

LTC1050CH Visão geral

The Analog Devices LTC1050CH is a single-circuit, precision zero-drift operational amplifier with a 0.5 uV input offset voltage, 10 pA input bias current, and internal chopper-stabilization capacitors packaged in an 8-terminal TO-5 metal can. The LTC1050CH is designed for instrumentation and signal-conditioning systems that require low DC offset and low input current without the external sample-and-hold capacitors normally associated with chopper amplifiers.

A zero-drift operational amplifier is a chopper-stabilized amplifier whose input offset voltage and related drift are periodically corrected to reduce low-frequency error. These amplifiers are used when slow changes in the input would create unacceptable measurement error. The LTC1050 belongs to the operational-amplifier hierarchy and ultimately falls within the broader category of analog signal-chain ICs used for amplification, buffering, instrumentation, feedback, and precision analog processing.

The principal advantage of the LTC1050CH is its combination of 0.5 uV input offset voltage and 10 pA input bias current. Integrating the two sample-and-hold capacitors on chip reduces the external component count normally associated with chopper-stabilized amplifiers. The CH ordering code identifies the industrial-temperature, wired-lead TO-5 package, while the underlying LTC1050 family is also offered in other package formats. Its zero-drift architecture is particularly relevant to low-frequency sensor signals where offset drift can dominate the useful measurement.

Unlike a conventional precision bipolar amplifier whose offset changes continuously with temperature and aging, the LTC1050 periodically corrects its offset to suppress very-low-frequency error. This chopping architecture can introduce ripple and broadband-noise effects, so system-level noise and bandwidth must be evaluated with the manufacturer application guidance. Input and output filtering, grounding, lead arrangement, and supply bypassing remain important when the amplifier operates near its input-offset or noise limits.

Typical uses include precision bridge and thermocouple amplifiers, low-level current measurement, strain-gauge signal conditioning, laboratory instrumentation, and slow sensor systems where input voltage changes are small relative to the signal of interest. The 10 pA input bias current is particularly useful with high-impedance sources, while the 0.5 uV offset supports measurements in which microvolt-level errors would otherwise consume a meaningful portion of the signal. The TO-5 metal-can package also provides a mechanically robust through-hole format for instrumentation equipment.

When designing around the LTC1050CH, use the manufacturer pin-description table for the 8-terminal TO-5 connection and preserve the specified package orientation. Place supply-bypass capacitors close to the device, use short feedback paths, and keep high-impedance input traces away from switching nodes. Confirm the final noise bandwidth and chopping-related ripple with the application circuit rather than relying only on the low DC offset specification.

This page combines the device identity, package information, manufacturer application resources, replacement guidance, and practical design considerations for engineers evaluating the LTC1050CH. The comparison information focuses on drop-in compatibility, while the application notes explain how zero-drift performance, input bias current, internal capacitors, and the TO-5 mechanical format affect instrumentation design.

Alternativas drop-in para LTC1050CH — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

Nenhuma alternativa drop-in disponível para este produto.

Solicitar alternativas

LTC1050CH Classificações máximas e características elétricas

Amplifier Type Precision zero-drift operational amplifier
Topologia Chopper-stabilized
Number of Circuits 1 circuit
Input Offset Voltage 0.5 uV
Input Bias Current 10 pA
Internal Sample-and-Hold Capacitors 2 integrated capacitors
Encapsulamento TO-5 metal can
Package Shape Round
Terminal Form Wire
Number of Terminals 8
Temperature Grade Industrial
Tipo de montagem Through-hole
Status do ciclo de vida Production

Guia de Configuração de Pinos do LTC1050CH round

Configuração de pinos para LTC1050CH (pacote round). Este componente analógico possui pinos de entrada, saída e alimentação. Consulte o datasheet do fabricante para configurações de offset null, compensação e pino de enable. Ideal para circuitos de condicionamento de sinal e amplificadores.

Diagrama de pinagem do pacote round para LTC1050CH

Nenhum dado detalhado de pinagem disponível para LTC1050CH.

Consulte a ficha técnica para a configuração completa dos pinos.

Aplicações típicas

LTC1050CH é adequado para 6 aplicaçãos: Precision Bridge Measurement, Thermocouple Signal Conditioning, High-Impedance Current Sensing, Strain-Gauge Instrumentation, Laboratory Measurement Equipment, Precision Sensor Interfaces.

🏭

Precision Bridge Measurement

The LTC1050CH is suitable for low-level bridge-amplifier input stages where its 0.5 uV input offset voltage limits static signal error and its 10 pA input bias current reduces disturbance of high-impedance sensor nodes. The chopper-stabilized architecture is valuable when the bridge output changes slowly and ordinary amplifier offset drift would obscure the measurement. The two integrated sample-and-hold capacitors reduce external conditioning circuitry, while the TO-5 metal-can package provides a robust through-hole implementation. Designers should still verify common-mode range, input bias behavior with the selected sensor, and chopping ripple across the intended measurement bandwidth.

🌡️

Thermocouple Signal Conditioning

The LTC1050CH can serve as the input amplifier for low-level thermocouple signals because a 0.5 uV offset specification is appropriate when the measured temperature corresponds to only a small differential voltage. Its 10 pA input bias current is especially helpful when long thermocouple wiring raises the effective source impedance and creates leakage-related errors. The integrated internal capacitors simplify the chopper-stabilized input stage compared with conventional designs requiring external sampling components. Practical use still requires input protection, proper input filtering, careful cold-junction compensation, and verification that the operating temperature and common-mode requirements fit the measurement system.

⚡

High-Impedance Current Sensing

The LTC1050CH fits low-level current measurement when the shunt or sensor output presents a high source impedance to the amplifier. Its specified 10 pA input bias current minimizes the bias-dependent voltage error that can obscure nanoamp-class or highly resistive signals, while the 0.5 uV offset reduces residual voltage error at the amplifier input. The device should be placed close to the sensing element to minimize leakage and capacitive pickup. Application engineering must confirm input common-mode limits, account for the amplifier's noise and chopping behavior, and ensure that the TO-5 wiring does not add excessive thermocouple or thermoelectric error.

🏗️

Strain-Gauge Instrumentation

For strain-gauge and piezoelectric-adjacent measurement systems, the LTC1050CH offers a low-offset input stage with 10 pA bias current and two integrated sample-and-hold capacitors. These characteristics are useful for slow mechanical measurements where the bridge output is small and temperature-dependent offset drift could dominate the result. The 8-terminal TO-5 package is mechanically suitable for through-hole instrumentation boards and can simplify hand-built or legacy-style analog modules. Designers should define the required noise bandwidth, assess aliasing around the chopper correction frequency, and apply guarding or shielding when source impedance is high enough for leakage to matter.

🔬

Laboratory Measurement Equipment

The LTC1050CH can improve the input stage of laboratory instruments that measure millivolts or microvolts from resistive, capacitive, or electrochemical sensors. The 0.5 uV offset reduces calibration burden when the useful signal is only slightly larger than the input error, while the 10 pA bias current protects measurements made through high-value source resistances. Its integrated chopper capacitors make the amplifier suitable for precision DC signal conditioning without reproducing the external sample-and-hold arrangement associated with many conventional chopper amplifiers. The system designer should still characterize chopping ripple, noise density, settling behavior, and input bias variation over the complete temperature range.

🧩

Precision Sensor Interfaces

The LTC1050CH is appropriate for precision sensor interfaces that combine slow signal variation with high source impedance. Its 0.5 uV offset minimizes static error at the input, and its 10 pA bias current reduces loading of the sensor. Because the amplifier is chopper-stabilized, the output must be filtered according to the required control bandwidth, and the correction spectrum must not be confused with the low-frequency drift it suppresses. The robust 8-terminal TO-5 construction is useful in industrial analog modules where a through-hole mechanical format is preferred over a fine-pitch surface-mount package.

What is the LTC1050CH?
The LTC1050CH is a single-circuit, precision zero-drift operational amplifier from Analog Devices. According to the manufacturer datasheet, it uses chopper stabilization, provides 0.5 uV input offset voltage and 10 pA input bias current, and integrates the two sample-and-hold capacitors normally required by chopper amplifiers. The CH version is packaged in an 8-terminal TO-5 metal can with wire leads.
What are the key specifications of LTC1050CH that engineers should know?
The LTC1050CH combines 0.5 uV input offset voltage, 10 pA input bias current, one amplifier circuit, and two on-chip sample-and-hold capacitors in an industrial-grade 8-terminal TO-5 package. According to the Analog Devices manufacturer datasheet, its zero-drift architecture minimizes low-frequency offset error without requiring the external capacitors normally associated with chopper-stabilized amplifiers.
Where can I download the LTC1050CH datasheet PDF?
The official LTC1050CH datasheet PDF is available from the Analog Devices technical-document URL for the LTC1050 family. The manufacturer document describes the zero-drift topology, internal capacitors, electrical characteristics, package information, and application guidance. Use the family datasheet together with the CH ordering-code information when assigning the exact 8-terminal TO-5 connections.
Where can I find the LTC1050CH pinout?
Use the pin-description and package drawings in the Analog Devices LTC1050 manufacturer datasheet to identify the 8-terminal TO-5 connections for the LTC1050CH. The CH suffix identifies a wired-lead metal-can configuration. Preserve the package orientation shown in the datasheet when connecting the device and place the bypass capacitors close to the power terminals.
What can replace the LTC1050CH?
A true replacement must match the LTC1050CH electrically and use the same 8-terminal TO-5 pinout; a functionally similar amplifier in SOIC or DIP is not a drop-in substitute. The available cross-reference information confirms the LTC1050 family and its package options but does not identify five distinct TO-5 devices that satisfy both pin compatibility and the key zero-drift parameters. Treat unverified equivalents as redesign candidates rather than drop-in parts.
Is LTC1050CH the same as other LTC1050 package options?
No. The LTC1050CH is the 8-terminal TO-5 metal-can version of the LTC1050 family, while other ordering codes use different package formats. According to the Analog Devices product page, the family is offered in 8-pin metal-can, plastic and ceramic dual-in-line packages, and an SO-8 package. A different LTC1050 package may retain similar core functionality but will not necessarily be pin-to-pin replaceable.
Where to buy LTC1050CH online?
Use the Request a Quote form on this page to request LTC1050CH availability, order quantities, and current commercial terms. The part is identified as a single-circuit TO-5 operational amplifier from Analog Devices. The form is the appropriate channel for exact-package confirmation, current inventory status, and lead-time information.
What is the price of the LTC1050CH?
Request the current LTC1050CH quotation through the Request a Quote form on this page. Commercial pricing can vary with order quantity, exact package, production status, and market conditions, so the platform should calculate the current offer rather than publishing a static figure. Include your target quantity and required delivery information in the request.
What is the lead time for LTC1050CH?
Request the current lead time and minimum order quantity through the Request a Quote form on this page. Analog Devices identifies the LTC1050 as a production family, but production status does not by itself establish available stock, scheduled delivery, or lot allocation for a specific quantity. The quotation response should confirm the TO-5 CH configuration and delivery commitment.
Is LTC1050CH in stock?
Confirm current LTC1050CH availability by submitting the required quantity through the Request a Quote form on this page. The manufacturer lists the LTC1050 family as production, while distributor and contract manufacturing stock can change independently. The quotation process provides an order-specific availability response for the exact 8-terminal TO-5 configuration.
LTC1050CH vs LTC1050 family alternatives - which is better for instrumentation?
The LTC1050CH is the preferable choice when the existing board requires a wired-lead 8-terminal TO-5 footprint and the application needs the family's 0.5 uV offset and 10 pA bias current. Other LTC1050 package options may offer equivalent core amplifier behavior, but they are not drop-in replacements when their lead arrangements differ. Evaluate package choice before comparing subtle electrical variations.
When should I choose the LTC1050CH over another zero-drift amplifier?
Choose the LTC1050CH when the design already uses an 8-terminal TO-5 outline, requires a 0.5 uV-class input offset, and benefits from 10 pA input bias current with minimal external sample-and-hold circuitry. It is particularly appropriate for high-impedance, slow sensor instrumentation. Select another package only when its electrical characteristics and environmental qualifications satisfy the complete system specification.
Is LTC1050CH suitable for high-impedance sensor measurement?
Yes, the LTC1050CH is suitable for high-impedance sensor measurement because its input bias current is specified at 10 pA. According to the Analog Devices manufacturer datasheet, the device also offers 0.5 uV input offset voltage and integrates its chopper-stabilization capacitors. Input capacitance, leakage, guarding, noise bandwidth, and chopping ripple must still be included in the complete error budget.
What are the main design considerations for the LTC1050CH?
The principal design considerations are input bias error, low-frequency offset correction, chopping-related noise, stability, and mechanical connection. Keep input leads short, guard high-impedance inputs as appropriate, place supply bypass capacitors near the device, and route outputs away from sensitive inputs. According to the manufacturer datasheet, the internal sample-and-hold capacitors reduce external circuitry but do not eliminate the need for careful board layout.
What is the best Analog Devices equivalent for the LTC1050CH?
The closest documented family choice is another suitably packaged LTC1050 device, but a direct drop-in equivalent must retain the LTC1050CH's 8-terminal TO-5 footprint and required electrical ratings. Analog Devices states that the family can improve on standard operational amplifiers in plug-in applications, yet that statement does not establish that every package code is pin-compatible. Confirm the exact package drawing and compare offset, bias current, supply range, bandwidth, and temperature limits before substitution.

Dados de referência de engenharia para LTC1050CH — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose the LTC1050CH when a design requires a wired-lead 8-terminal TO-5 amplifier, approximately 0.5 uV input offset, 10 pA input bias current, and an integrated chopper-stabilization arrangement. It is well suited to slow bridge, thermocouple, strain-gauge, laboratory, and high-impedance sensor measurements. Other LTC1050 package options may provide similar core performance but are not drop-in choices when the PCB footprint or lead arrangement differs. Do not substitute a conventional precision op amp solely for its low offset: bias current, noise, stability, bandwidth, chopping ripple, input range, and temperature behavior must all satisfy the application. For a legacy TO-5 board, verify the exact pinout and compare the complete electrical specification of any proposed replacement before production use.

Comparação com alternativas

Parâmetro Este produto
Brand Analog Devices
Package 8-terminal TO-5 metal can
Mounting Type Through-hole
Temperature Grade Industrial
Amplifier Architecture Precision zero-drift chopper-stabilized operational amplifier
Number of Circuits 1 circuit
Input Offset Voltage 0.5 uV
Input Bias Current 10 pA
Internal Sample-and-Hold Capacitors 2 integrated capacitors
Number of Terminals 8

Principais diferenciais

  • Very low input offset for precision DC instrumentation (vs LTC1050 family options in SO-8 and dual-in-line packages)
  • Reduced external chopper-conditioning circuitry (vs Conventional chopper-stabilized operational amplifiers requiring external sampling capacitors)
  • Low input bias current for high-impedance sensing (vs Conventional precision bipolar operational amplifiers)

Notas de projeto

Keep high-impedance input and feedback routes short and away from switching or high-current traces. The LTC1050CH's 10 pA input bias current is valuable for high-source-impedance measurements, but board leakage, contaminated insulation, and nearby digital activity can still dominate the error. Use guarding where appropriate and verify the complete assembled system rather than relying only on the device's input-bias specification.

Follow the manufacturer datasheet pinout and package orientation for the 8-terminal TO-5 connection. Place supply-bypass components close to the relevant device terminals, maintain a low-impedance ground return, and keep the feedback loop compact. Because the TO-5 device uses through-hole leads, pay particular attention to lead resistance and thermally induced junctions in precision measurement boards.

Do not judge the LTC1050CH only by its 0.5 uV DC offset specification. Chopper-stabilized amplifiers can produce correction-spectrum components, and the usable bandwidth depends on the required signal bandwidth and output filtering. Establish the required noise and settling limits, simulate the complete filter, and verify operation across input range, load, supply, and temperature before releasing the design.

Informações de conformidade

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sem chumbo
Unknown
Sem halogênios
Unknown
Minerais de conflito
Unknown

The LTC1050 is a production precision operational amplifier, but no explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals declaration appears in the available manufacturer and distributor information. AEC-Q100 qualification is not applicable to this industrial TO-5 device based on the listed industrial temperature grade.

Dados verificados em: 2026-11-19 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

ltc1050 datasheet ltc1050 liebherr ltc1050 crane LTC1050CH datasheet LTC1050CH pinout LTC1050CH specifications LTC1050CH datasheet pdf LTC1050CH equivalent LTC1050CH replacement LTC1050CH TO-5 pinout LTC1050CH price LTC1050CH stock Analog Devices LTC1050CH LTC1050 zero drift op amp application

Componentes & termos relacionados

Analog Devices Linear Technology LTC1050 LTC1050CH precision zero-drift operational amplifier chopper-stabilized operational amplifier operational amplifier analog signal-chain IC input offset voltage input bias current zero drift sample-and-hold capacitor TO-5 metal can 8-terminal TO-5 through-hole package industrial temperature grade bridge amplifier thermocouple signal conditioning high-impedance sensor measurement strain-gauge instrumentation chopping ripple noise bandwidth Analog Devices LTC1050 manufacturer datasheet
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue
Ver detalhes da RFQ