MAX358CWE+ - Fault-Protected 8:1 Analog Multiplexer | ADI
N.º da peça: MAX358CWE+ ✓ AtivoMAX358CWE+ Visão geral
An analog multiplexer is an interface IC that routes one of several input channels to a shared output or measurement path. The MAX358 belongs to the broader hierarchy of analog switches, multiplexers, interface ICs and semiconductors. By selecting among eight single-ended inputs with controlled switches, it reduces the number of signal lines required between sensors, test points, data-conversion systems and other analog circuits.
The MAX358 family combines an 8:1 configuration with 1.8 kOhm on-resistance and approximately 1 MHz bandwidth. Its listed operating supply range is 4.5 V to 18 V, while the fault-protection architecture provides protection for overvoltage conditions extending to ±35 V beyond the supply rails when power is removed. The manufacturer describes the implementation as a series N-channel, P-channel, N-channel structure.
MAX358 is the single-ended member of a related fault-protected multiplexer family. The MAX359 provides a four-channel differential configuration, while the MAX358 is intended for eight-channel single-ended routing. The device uses address and control inputs to select the active path and supports analog signal multiplexing in systems where input faults, limited board area and modest bandwidth are more important than very low on-resistance.
Typical uses include data acquisition, instrumentation, test and measurement, industrial control, battery monitoring and embedded analog signal routing. The 1 MHz bandwidth is suitable for many sensor and control signals, while the fault-protection feature helps isolate downstream circuitry from excessive input voltage. System designers should still validate signal levels, transition behavior and protection conditions against the manufacturer datasheet.
PCB implementation requires careful routing of the selected analog path and control signals to prevent interference between channels. Place the multiplexer close to the source or destination of the routed signal, maintain a continuous ground reference, and follow the datasheet layout guidance for bypass capacitors and exposed routing areas.
This product page combines the manufacturer specifications with practical design guidance, package information, sourcing workflow and verified drop-in alternatives. It is intended to help engineers determine whether the MAX358CWE+ fits an analog routing design before detailed circuit simulation and board validation.
Alternativas drop-in para MAX358CWE+ — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Nenhuma alternativa drop-in disponível para este produto.
Solicitar alternativasMAX358CWE+ Especificações
| Multiplexer Configuration | 8:1 |
| Number of Channels | 8 channels |
| Signal Type | Single-ended analog |
| On-Resistance | 1.8 kOhm |
| Bandwidth | 1 MHz |
| Crosstalk | 42 dB |
| Supply Voltage Range | 4.5 V to 18 V |
| Fault-Protection Range | Up to ±35 V beyond supply rails |
| Internal Switch Structure | Series N-channel, P-channel, N-channel |
| Número de pinos | 16 pins |
| Encapsulamento | 16-pin SOIC |
| Tipo de montagem | Surface mount |
| Operating Temperature Grade | Commercial extended temperature grade |
Guia de Configuração de Pinos do MAX358CWE+ 16-pin soic
Configuração de pinos para MAX358CWE+ (pacote 16-pin soic). A numeração dos pinos, funções e diagramas de conexão estão definidos no datasheet do fabricante. Consulte-o para o footprint exato e diretrizes de soldagem.
Nenhum dado detalhado de pinagem disponível para MAX358CWE+.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
MAX358CWE+ é adequado para 6 aplicaçãos: Multichannel Data Acquisition, Automated Test Equipment, Industrial Sensor Multiplexing, Battery Cell Monitoring, Instrumentation Signal Routing, Embedded Control Interfaces.
Multichannel Data Acquisition
The MAX358CWE+ fits data-acquisition systems that must route eight single-ended sensor signals through a shared amplifier, ADC or measurement instrument. Its 8:1 configuration reduces the number of analog connections reaching the converter, while approximately 1 MHz bandwidth covers many pressure, temperature, position and industrial process signals. The 1.8 kOhm on-resistance must be included when calculating source loading and attenuation. For high-impedance sensors, verify settling behavior and add suitable buffering when the selected ADC input requires a lower source impedance. The fault-protected architecture is particularly valuable where an external wiring fault could otherwise place excessive voltage on the multiplexed input.
Recomendado
Automated Test Equipment
The MAX358CWE+ can select among eight test points or instrument channels in automated test equipment, reducing the number of analog paths required between the DUT interface and measurement circuitry. The approximately 1 MHz bandwidth is suitable for many low- and moderate-frequency production tests, including continuity, resistance, sensor response and signal-conditioning checks. Because the multiplexer contributes 1.8 kOhm of on-resistance, test engineers should account for path resistance and add external compensation when measuring high-impedance nodes. The fault-protected input structure helps prevent an out-of-range DUT signal from propagating excessive fault voltage through the routing network.
Recomendado
Industrial Sensor Multiplexing
The MAX358CWE+ is suitable for industrial control boards that collect multiple single-ended sensors and route them to a shared controller or analog front end. It accommodates eight channels in a compact 16-pin SOIC and operates from a 4.5 V to 18 V supply, covering common industrial signal-chain voltages. The fault-protection architecture is valuable when sensors and field wiring can experience transients or wiring faults. Designers should still provide normal input clamping, protection and filtering as appropriate for the installation. The 1.8 kOhm on-resistance is important when sensors have high output impedance because the selected path will load the source and can create measurement error.
Recomendado
Battery Cell Monitoring
The MAX358CWE+ can multiplex multiple single-ended battery or power-monitoring taps into a shared measurement channel. Its 8:1 configuration helps limit the number of analog inputs required by the monitoring circuitry, while the 4.5 V to 18 V operating range is compatible with appropriately designed measurement systems. Fault protection is particularly relevant when monitored nodes are exposed to unexpected voltage transients. The circuit designer must confirm that every monitored node remains within the absolute maximum ratings, including during abnormal conditions. The 1.8 kOhm path resistance should be included in the acquisition front end, particularly for high-impedance dividers and precision measurements.
Recomendado
Instrumentation Signal Routing
The MAX358CWE+ fits instrumentation designs that need to route several low-frequency analog sources into a shared precision measurement path. Eight single-ended channels can be selected by address and enable logic, reducing wiring complexity around the measurement frontend. Its approximately 1 MHz bandwidth supports many sensor and control-bandwidth signals, although the 1.8 kOhm on-resistance may require compensation in high-impedance systems. The fault-protected structure improves robustness when external inputs can experience wiring errors. Instrument designers should also evaluate leakage, channel switching transients and settling behavior using the manufacturer test conditions.
Recomendado
Embedded Control Interfaces
The MAX358CWE+ can expand the analog input capacity of an embedded controller by selecting one of eight single-ended signals for conversion or supervision. The compact SOIC-16 package preserves board area, and the 1.8 kOhm on-resistance is compatible with many moderately low-impedance sensor networks. Address-control logic allows the firmware to scan channels sequentially, while the fault-protection architecture adds resilience to connector or wiring faults. Engineers should select external input protection for the exact surge environment, confirm channel-to-channel isolation in the target bandwidth and verify that the selected analog front end settles within the required sampling interval.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para MAX358CWE+ — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto |
|---|---|
| Package | 16-pin SOIC |
| Brand | Analog Devices |
| Multiplexer Configuration | 8:1 |
| Number of Channels | 8 single-ended channels |
| On-Resistance | 1.8 kOhm |
| Bandwidth | 1 MHz |
| Supply Voltage Range | 4.5 V to 18 V |
| Crosstalk | 42 dB |
| Fault Protection | Up to ±35 V beyond supply rails under the specified power-removed condition |
Principais diferenciais
- Combines eight-way routing with fault protection (vs Conventional unprotected analog multiplexer)
- Single-ended routing in a compact surface-mount package (vs MAX358CPE+)
- Useful bandwidth for low- and moderate-frequency instrumentation (vs MAX359)
Notas de projeto
Place the MAX358CWE+ close to the multiplexed signal source or destination to minimize trace resistance, capacitance and susceptibility to interference. Route the selected analog channel as a continuous, compact path, keep digital address and enable traces away from sensitive inputs, and use a solid ground reference. Follow the manufacturer datasheet for bypass-capacitor placement and recommended layout geometry.
Do not treat the stated ±35 V fault-protection capability as permission to exceed the absolute maximum ratings during normal operation. Confirm the exact supply-off condition, input current, duration and pin limits in the manufacturer datasheet. The 1.8 kOhm on-resistance can also create attenuation and settling errors in high-impedance networks, so include it in the signal-path calculation.
Analyze the complete switched path rather than relying only on the 1 MHz bandwidth figure. Include source impedance, 1.8 kOhm on-resistance, load capacitance, control-line timing and downstream acquisition time. For precision or high-impedance measurements, add a low-capacitance buffer after the multiplexer and verify crosstalk and channel-to-channel switching transients on the finished layout.
Informações de conformidade
The MAX358CWE+ is identified as a production MAX358 family member. RoHS, REACH, AEC-Q100, lead-free, halogen-free and conflict-minerals status require confirmation from the manufacturer product documentation or current compliance declarations.