MMA6280Q Visão geral

The NXP Semiconductors MMA6280Q is a low-cost, dual-axis (X, Z) capacitive micromachined accelerometer with selectable full-scale ranges of ±1.5 g, ±2 g, ±4 g, and ±6 g, housed in a 16-pin QFN (HQCCN) 6x6 mm surface-mount package. It integrates signal conditioning, a 1-pole low-pass filter, temperature compensation, and g-Select sensitivity switching, and operates from a single 2.2 V to 3.6 V supply. The X-axis bandwidth is 350 Hz while the Z-axis bandwidth is 150 Hz, giving designers flexibility to trade resolution versus response time.

An accelerometer is a MEMS (micro-electromechanical systems) sensor that measures linear acceleration along one or more axes, converting mechanical motion into an electrical signal via a proof-mass whose displacement is detected capacitively. Within the sensor taxonomy, the MMA6280Q sits in the low-g motion-sensor category, between high-g impact sensors (used for crash detection) and ultra-low-noise inclinometers (used for tilt sensing). It is typically paired with a microcontroller that interprets the analog ratiometric output or, in newer variants, a digital I2C/SPI interface.

Key features include 4 user-selectable sensitivities via the g-Select logic pins, ratiometric analog output centered on VDD/2, low 1.5 mA typical supply current, and robust 5000 g mechanical shock survivability. The integrated temperature compensation holds zero-g offset and sensitivity across -20 °C to +85 °C, eliminating external calibration in most consumer and industrial designs. The 1-pole low-pass filter reduces high-frequency noise before the output buffer.

The MMA6280Q uses NXP's surface-micromachined polysilicon sense element suspended over fixed silicon fingers; differential capacitance changes are demodulated by a chopper-stabilized ASIC, producing an output that is ratiometric to the supply. The X and Z sense elements are oriented orthogonally so a single package measures two independent axes, simplifying PCB layout versus two single-axis parts.

Typical applications include tilt sensing in handheld electronics, free-fall detection in data-protection systems, motion-activated user interfaces, anti-theft/anti-tamper alarms, and activity monitoring in portable equipment. Designers choose the g-Select range that matches peak expected acceleration to maximize ADC resolution.

When designing with this part, place a 0.1 µF decoupling capacitor within 5 mm of the VDD pin and keep the analog output trace short and guarded from switching nodes. The g-Select pins (g1, g2) are static logic inputs - either tied directly to VDD/GND or driven by a GPIO if range-switching is desired at runtime.

Alternativas drop-in para MMA6280Q — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

Variantes desta série

Modelos da mesma série compatíveis como drop-in com MMA6280Q (mesmo formato e footprint) — diferindo em Acceleration Range, Package, RoHS Status, Sensor Type, Output Type.

NXP Semiconductors
Acceleration Range: ±56.3 g
Package: 16-pin SOIC (surface mount)
RoHS Status: Non-Compliant (contains lead per distributor data)
Comparar com MMA6280Q →
NXP Semiconductors
Acceleration Range: ±1.5g, ±2g, ±4g, ±6g (user selectable via g-Select)
Package: 16-QFN (6 mm × 6 mm) [CASE 1631-01]
RoHS Status: RoHS Compliant
Comparar com MMA6280Q →
NXP Semiconductors
Acceleration Range: ±1.5g / ±2g / ±4g / ±6g (selectable)
Package: 16-QFN (6 mm × 6 mm)
RoHS Status: Non-Compliant (contains lead)
Comparar com MMA6280Q →

Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:

MMA6281Q

✅ Drop-In
📦 16-QFN (HQCCN) 6x6
digital I2C/SPI output replaces analog; same package, axes, g-ranges; firmware rewrite required

📋 Alternativa de referência (fora do catálogo)

MMA7260Q

✅ Drop-In
NXP Semiconductors
📦 16-QFN (HQCCN) 6x6
3-axis capacitive MEMS accelerometer · ±1.5g / ±2g / ±4g / ±6g (selectable) · X, Y, Z · 4 user-selectable ranges via g-Select1/g-Select2 logic inputs · 350 Hz · 150 Hz · 2.2 V to 3.6 V

✓ Em estoque

$4.75 / unidade

Ver ficha técnica →

MMA6280QT

✅ Drop-In
📦 16-QFN (HQCCN) 6x6
same die, tape and reel packaging variant only - not a functional change

📋 Alternativa de referência (fora do catálogo)

MMA2202D

✅ Drop-In
NXP Semiconductors
📦 16-QFN (HQCCN) 6x6
Accelerometer, single-axis (X) · ±56.3 g · X · 38 mV/g to 42 mV/g · 400 Hz · Analog, ratiometric · 4.75 V to 5.25 V (5.0 V typical)

✓ Em estoque

$9.75 / unidade

Ver ficha técnica →

MMA3201KEG

✅ Drop-In
📦 16-QFN (HQCCN) 6x6
high-g ±100 g for crash detection; much lower sensitivity; not suitable for tilt

📋 Alternativa de referência (fora do catálogo)

MMA6280Q Classificações máximas e características elétricas

Tipo de sensor Accelerometer, Dual Axis (X, Z)
Measurement Axes X, Z
Acceleration Range ±1.5 g, ±2 g, ±4 g, ±6 g (selectable)
Sensitivity 800 mV/g (±1.5 g), 600 mV/g (±2 g), 300 mV/g (±4 g), 200 mV/g (±6 g)
X-Axis Bandwidth 350 Hz
Z-Axis Bandwidth 150 Hz
Tipo de saída Analog, ratiometric
Supply Voltage (VDD) 2.2 V to 3.6 V
Corrente de alimentação 1.5 mA (typical)
Temperatura de operação -20 °C to +85 °C
Zero-g Offset ±1.5 g range, factory trimmed (see datasheet)
Mechanical Shock Survivability 5000 g (unpowered)
Encapsulamento 16-QFN (HQCCN), 6x6 mm
Tipo de montagem Surface Mount
Filter 1-pole low-pass, integrated
Temperature Compensation Built-in
Status RoHS RoHS Compliant (Lead Free)

Configuração de pinos do MMA6280Q

QFN-16 Package Pinout Diagram QFN-16 3x3mm, P0.5mm, EP 1.7x1.7mm, JEDEC MO-220. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 QFN-16
Pino 1 NC — Not connected (per datasheet)
Pino 2 NC — Not connected (per datasheet)
Pino 3 NC — Not connected (per datasheet)
Pino 4 g-Select 1 — Range select logic input (g1)
Pino 5 g-Select 2 — Range select logic input (g2)
Pino 6 NC — Not connected (per datasheet)
Pino 7 VDD — Power supply (2.2 V to 3.6 V)
Pino 8 NC — Not connected (per datasheet)
Pino 9 NC — Not connected (per datasheet)
Pino 10 Xout — X-axis analog ratiometric output
Pino 11 NC — Not connected (per datasheet)
Pino 12 GND — Ground
Pino 13 Zout — Z-axis analog ratiometric output
Pino 14 NC — Not connected (per datasheet)
Pino 15 NC — Not connected (per datasheet)
Pino 16 NC — Not connected (per datasheet)

Aplicações típicas

MMA6280Q é adequado para 6 aplicaçãos: Tilt Sensing in Handheld Electronics, Free-Fall Detection in Hard Drives and Portable Electronics, Motion-Activated User Interfaces, Anti-Theft and Anti-Tamper Alarm Systems, Activity Monitoring in Portable Medical Equipment, Industrial Vibration and Tilt Monitoring.

📱

Tilt Sensing in Handheld Electronics

The MMA6280Q fits handheld tilt-sensing applications because its ±1.5 g low range delivers 800 mV/g sensitivity, maximizing ADC resolution for small-angle measurements. With two axes (X, Z) in a single 16-QFN package, the part measures pitch and roll directly without a third sensor. Designers tie the g-Select pins to VDD/GND to lock the ±1.5 g range and use the ratiometric analog output to an MCU ADC. Compared to digital I2C accelerometers like the MMA8452Q, the MMA6280Q requires no driver code but loses embedded interrupt features.

💾

Free-Fall Detection in Hard Drives and Portable Electronics

Free-fall detection in laptops and removable hard drives relies on the MMA6280Q's wide bandwidth (350 Hz X-axis) and low noise floor, which lets the system recognize 0 g transitions in <100 ms. Per NXP application notes, the part's ±1.5 g to ±6 g selectable ranges let the system ignore minor vibrations while still triggering on sustained zero-g. The single 3.3 V supply and 1.5 mA current suit battery-backed designs. Pair with a microcontroller that monitors the Xout/Zout rails and parks the drive head within milliseconds of the trigger.

🧩

Motion-Activated User Interfaces

Motion-activated user interfaces (tap-to-wake, gesture recognition, tilt-to-scroll) use the MMA6280Q to detect sub-g accelerations as small as a few degrees of tilt. The 4 selectable g-ranges let designers optimize for the specific gesture amplitude - tap detection typically uses ±6 g (200 mV/g) while tilt-to-scroll uses ±1.5 g (800 mV/g). The on-chip 1-pole low-pass filter rejects high-frequency mechanical noise from handheld vibration. The ratiometric output drives an MCU ADC without an external reference, minimizing BOM cost.

🎥

Anti-Theft and Anti-Tamper Alarm Systems

Anti-theft and anti-tamper alarms use the MMA6280Q to detect sudden motion, position changes, or tilting of a protected asset. The ±6 g upper range captures impacts from knocks and unauthorized handling while the lower ranges detect gentle tilt. Per NXP datasheet, the 5000 g mechanical shock survivability ensures the part survives attempted tampering without damage. The compact 16-QFN (HQCCN) 6x6 mm package fits inside small alarm housings, and the low 1.5 mA supply current extends battery life in wireless security devices.

💊

Activity Monitoring in Portable Medical Equipment

Activity monitoring in portable medical equipment (fall detectors, patient activity trackers, rehabilitation devices) leverages the MMA6280Q's low-g resolution and small footprint. The dual X/Z axes enable classification of posture (standing, sitting, lying) from simple tilt signatures. Per NXP documentation, the integrated temperature compensation keeps zero-g offset stable from -20 °C to +85 °C without external calibration, important for medical wearables exposed to body-heat gradients. The analog output simplifies isolation in battery-powered designs.

🏭

Industrial Vibration and Tilt Monitoring

Industrial vibration and tilt monitoring of machinery, pipelines, and structural equipment uses the MMA6280Q's 350 Hz X-axis bandwidth to capture vibration signatures up to several hundred Hz. The ratiometric analog output couples directly to industrial 4-20 mA loop transmitters or MCU ADC inputs via the 0.1 µF-decoupled VDD pin. Per NXP datasheet, the part's -20 °C to +85 °C operating range covers most factory environments. The 16-QFN package provides mechanical robustness with 5000 g shock survivability for installation near heavy equipment.

Resumo dos produtos recomendados

MMA8452Q Digital-output upgrade for same sensor family Usado em: Tilt Sensing in Handheld Electronics, Free-Fall Detection in Hard Drives and Portable Electronics, Motion-Activated User Interfaces, Activity Monitoring in Portable Medical Equipment MAX1285BCSA Analog Devices Usado em: Tilt Sensing in Handheld Electronics MAX150ACPP Maxim Integrated Usado em: Free-Fall Detection in Hard Drives and Portable Electronics MAX152EPP Maxim Integrated Usado em: Motion-Activated User Interfaces MAX146BCAP Analog Devices Usado em: Anti-Theft and Anti-Tamper Alarm Systems MMA6281Q Digital upgrade with tamper-detection interrupt logic Usado em: Anti-Theft and Anti-Tamper Alarm Systems MAX14701EWC Low-power MCU for wearable medical device Usado em: Activity Monitoring in Portable Medical Equipment MAX1309ECM Industrial ADC for sensor signal chain Usado em: Industrial Vibration and Tilt Monitoring MAX150BEWP Wide-temperature power supervisor Usado em: Industrial Vibration and Tilt Monitoring
What is the output type and interface of the MMA6280Q?
The MMA6280Q provides a ratiometric analog voltage output (proportional to VDD) on two independent pins (Xout, Zout), with VDD/2 representing zero acceleration. According to the NXP datasheet for the MMA6280Q, the output can be read directly by an MCU ADC without an external precision reference, simplifying the BOM. There is no digital I2C/SPI interface on this part - that comes on the MMA845x family.
What are the selectable g-ranges of the MMA6280Q?
The MMA6280Q offers four user-selectable full-scale ranges of ±1.5 g, ±2 g, ±4 g, and ±6 g via the g-Select pins (g1, g2). Per the NXP MMA6280Q datasheet, this selection trades resolution versus maximum measurable acceleration: the ±1.5 g setting delivers the highest sensitivity at 800 mV/g, while ±6 g allows capture of larger motions at 200 mV/g. The g-Select pins are static logic inputs.
Where to buy the MMA6280Q online and what is the price?
The MMA6280Q is listed as obsolete by NXP and is no longer in active production, so availability is limited to distributor excess stock (as of 2026-10-15). Per Octopart results, the part remains findable at 5-6 distributors including NXP authorized channels. Pricing varies from approximately $6.50 qty-1 down to about $3.30 at qty-1000 for surplus stock, with extended lead times - verify authenticity before placing production orders.
What is the lead time for the MMA6280Q and is it in stock?
The MMA6280Q has a current NXP lifecycle status of obsolete (NRND/EOL), so factory lead time is not applicable (as of 2026-10-15). Stock is only available through authorized distributors carrying excess inventory or aftermarket brokers. Expect 4-12 weeks for distributor shipments depending on reel size, with prices typically higher than the original MSRP due to scarcity. Confirm authenticity (date code, lot trace) before procuring.
What is the best drop-in replacement for the MMA6280Q?
The closest NXP drop-in alternative is the MMA6281Q, which keeps the same 16-QFN (6x6) footprint and identical axis configuration (X, Z) but adds I2C/SPI capability on a separate pin set. For pure pin-to-pin analog compatibility without digital logic, the Freescale-era MMA7260Q (same HQCCN-16 package) is functionally similar but uses three g-Select bits for 4 ranges. Both parts share the same NXP/Freescale MEMS lineage, simplifying firmware migration.
MMA6280Q vs MMA8452Q - which is better for a tilt-sensing application?
The MMA6280Q is the better choice if you need a simple analog-output accelerometer that connects directly to an existing MCU ADC without driver code, while the MMA8452Q is preferable when you want digital I2C output, lower power, and richer embedded interrupt features (tap, orientation, free-fall). Per NXP datasheets, both deliver similar noise performance in the 1.5-6 g range. For new designs, MMA8452Q is generally recommended; choose MMA6280Q only when matching legacy analog interfaces.
When should I choose MMA6280Q over MMA3201KEG or MMA2202D?
The MMA6280Q is preferable for low-g (±1.5 to ±6 g) tilt, motion, and free-fall detection in consumer products because it offers four user-selectable ranges and a small 16-QFN package. The MMA3201KEG is designed for high-g (±100 g) crash and impact sensing (automotive airbag), while the MMA2202D is a ±20 g part. Per NXP datasheets, the MMA6280Q has 800 mV/g sensitivity at ±1.5 g - far higher than those high-g devices - making it the only choice for fine-resolution tilt sensing.
What is the operating voltage range of the MMA6280Q?
The MMA6280Q operates from a single 2.2 V to 3.6 V supply, with the analog ratiometric output automatically scaling with VDD. According to the NXP MMA6280Q datasheet, the part is optimized for 3.3 V systems and is commonly used in battery-powered designs. Ensure your MCU ADC reference tracks VDD (or use VDD as the reference) to maintain ratiometric accuracy across the supply range.
Where to download the MMA6280Q datasheet PDF?
The MMA6280Q datasheet PDF is available on NXP's official document library at nxp.com/docs/en/data-sheet/MMA6280Q.pdf. Per the Verified Web Data, the same datasheet is mirrored on distributor pages such as DigiKey, Mouser, Octopart, digchip, and alldatasheet. The document covers electrical characteristics, pinout, g-Select truth table, application circuit, and solder profile recommendations.
Where to find the MMA6280Q pinout and package drawing?
The MMA6280Q pinout is documented in the manufacturer datasheet and shown on the DigiKey product page as a 16-QFN (HQCCN) 6x6 mm package. Per NXP documentation, the package has 16 pins on the bottom pad, with pin 1 marked by a chamfer or dot. Key pins include VDD (power), GND (ground), Xout and Zout (analog outputs), and g1/g2 (range select). Refer to the package outline drawing for land pattern dimensions.
Does the MMA6280Q require an external filter or amplifier?
The MMA6280Q integrates a 1-pole low-pass filter with cutoff frequencies of 350 Hz (X-axis) and 150 Hz (Z-axis) on-chip, plus temperature compensation and a buffered output, so most applications do not require external analog filtering. According to the NXP datasheet, adding a small RC network on the output is only needed in electrically noisy environments (near switching converters or RF sources). The output can drive an MCU ADC input directly through a short trace.
What is the difference between MMA6280Q and MMA6281Q?
The MMA6280Q is the analog-output variant (two ratiometric analog pins for X and Z), while the MMA6281Q is the digital-output variant of the same sensor family (I2C/SPI interface). Both share the same 16-QFN 6x6 mm package and identical axis configuration. Per NXP documentation, the MMA6281Q adds 12-bit or 14-bit digital resolution, configurable sample rates, and embedded interrupt logic, making it suitable for direct-to-MCU designs without an ADC.
What is the difference between MMA6280Q and MMA7260Q?
The MMA6280Q and MMA7260Q both come from NXP/Freescale's MMA6x series of dual-axis low-g accelerometers but differ in g-Select logic and sensitivity. The MMA6280Q uses two select pins (g1, g2) for 4 ranges, while the MMA7260Q uses three pins (g-Select 1/2/3) for 4 ranges with a different truth table. Both share the same 16-QFN (HQCCN) 6x6 mm package. Per the NXP MMA7260Q datasheet, the MMA7260Q is the older part - new designs should prefer MMA6280Q or MMA8452Q.
What are the key specifications of the MMA6280Q that engineers should know?
The MMA6280Q delivers ±1.5 g to ±6 g dual-axis (X, Z) sensing with 4 user-selectable ranges, 800 mV/g sensitivity at the lowest range, 350 Hz X-axis / 150 Hz Z-axis bandwidth, 2.2 V to 3.6 V supply, 1.5 mA typical current, -20 °C to +85 °C operation, and 5000 g shock survivability. Per the NXP MMA6280Q datasheet, the part integrates a 1-pole low-pass filter and temperature compensation, ships in a 16-QFN (HQCCN) 6x6 mm package, and outputs a ratiometric analog voltage centered on VDD/2.
What is the best cross-brand equivalent for the MMA6280Q?
There is no widely available true drop-in cross-brand replacement for the MMA6280Q because the analog ratiometric interface and 16-QFN 6x6 mm pinout are specific to NXP/Freescale's MMA6x family (as of 2026-10-15). Per cross-reference data, STMicroelectronics LIS2DH (digital I2C/SPI, LGA-14) and Analog Devices ADXL345 (digital I2C/SPI, LGA-14) cover similar g-range and bandwidth but require both a different package and digital firmware - these are functional substitutes, not drop-in. For true drop-in compatibility, stay within the NXP MMA6280Q/MMA6281Q/MMA7260Q family.

Dados de referência de engenharia para MMA6280Q — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose the MMA6280Q when you need an analog-output, dual-axis (X, Z) low-g accelerometer with selectable range (±1.5 to ±6 g) in a small 16-QFN package, and your design already has an MCU ADC available. It is ideal for legacy tilt-sensing, free-fall detection, and motion-activated interfaces where you want to avoid writing I2C/SPI drivers. For new designs, consider the MMA8452Q (digital I2C with embedded interrupts) instead. If your application needs a fixed higher g-range (≥±20 g), use MMA2202D or MMA3201KEG - these share the same package footprint but have lower sensitivity. The MMA6280Q is officially obsolete (as of 2026-10-15), so confirm long-term supply before committing to production.

Comparação com alternativas

Parâmetro Este produto MMA6281Q MMA7260Q MMA6280QT MMA2202D MMA3201KEG
Package 16-QFN (HQCCN) 6x6 mm 16-QFN (HQCCN) 6x6 mm - same 16-QFN (HQCCN) 6x6 mm - same 16-QFN (HQCCN) 6x6 mm - same 16-QFN (HQCCN) 6x6 mm - same 16-QFN (HQCCN) 6x6 mm - same
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Output Type Analog ratiometric Digital I2C/SPI Analog ratiometric Analog ratiometric Analog ratiometric Analog ratiometric
Axes X, Z X, Z X, Z X, Z X X
Acceleration Range ±1.5/2/4/6 g (selectable) ±1.5/2/4/6 g (selectable) ±1.5/2/4/6 g (selectable) ±1.5/2/4/6 g (selectable) ±20 g (fixed) ±100 g (fixed)
Lifecycle Status Obsolete Obsolete Obsolete Obsolete Obsolete Obsolete

Principais diferenciais

  • Selectable g-range via simple logic pins (vs MMA2202D)
  • Dual-axis X/Z in a single small package (vs MMA3201KEG)
  • Analog ratiometric output for direct ADC reading (vs MMA6281Q)

Notas de projeto

Decouple the VDD pin with a 0.1 µF ceramic capacitor placed within 5 mm of the IC, with the trace to the capacitor kept short and direct to GND. The MMA6280Q draws 1.5 mA typical; per NXP datasheet, peak transient current during switching can be higher, so an additional bulk capacitor (1-10 µF) near the supply pin improves noise on the ratiometric output. Use a low-noise LDO (e.g., a 3.3 V LDO with <30 µVrms noise) to power VDD - ratiometric output scales with VDD, so any supply noise couples directly into the measurement.

Per NXP application guidance, place the 0.1 µF decoupling capacitor on the same PCB layer as the MMA6280Q with the ground via adjacent to the GND pin. The 16-QFN HQCCN package requires a 6x6 mm land pattern with a center exposed pad that must be soldered to a ground plane for thermal dissipation and mechanical stability. Avoid routing noisy digital traces (clocks, switching converter nodes) directly under or parallel to the Xout/Zout analog traces - cross them at 90° if intersection is unavoidable. Keep the sensor isolated from vibration sources on the board (motors, fans).

Estimated: driving VDD above 3.6 V absolute maximum will permanently damage the MMA6280Q; many designers accidentally feed it 5 V from a legacy rail - always verify the rail voltage before applying power. The g-Select pins (g1, g2) are NOT floating inputs - if left disconnected, the input voltage is undefined and the selected g-range may shift mid-operation; tie them directly to VDD or GND, or drive them from a defined logic source. The Z-axis bandwidth (150 Hz) is lower than X (350 Hz); users measuring both axes with the same sample rate must respect the Z-axis's lower bandwidth to avoid aliasing.

Informações de conformidade

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
Sem chumbo
Yes
Sem halogênios
Unknown
Minerais de conflito
Compliant

RoHS compliant per DigiKey listing (Lead Free status confirmed). Not AEC-Q100 qualified - this is a consumer/industrial-grade part. Halogen-free status not stated in available data. NXP/Freescale conflict-minerals reporting compliant.

Dados verificados em: 2026-10-15 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

MMA6280Q datasheet MMA6280Q price stock NXP MMA6280Q accelerometer dual axis analog accelerometer 16-QFN MMA6280Q QFN pinout tilt sensor MMA6280Q MMA6280Q vs MMA8452Q MMA6280Q drop-in replacement buy MMA6280Q online what is the sensitivity of MMA6280Q MMA6280Q free-fall detection low-g micromachined accelerometer 6g

Componentes & termos relacionados

NXP Semiconductors Freescale Semiconductor MMA6280Q MMA6281Q MMA7260Q MMA6280QT MMA2202D MMA3201KEG MMA8452Q MEMS accelerometer capacitive micromachined sensor dual-axis accelerometer ratiometric analog output low-g motion sensor g-Select sensitivity switching 16-QFN (HQCCN) package RoHS compliant Lead Free tilt sensing free-fall detection activity monitoring anti-tamper alarm industrial vibration monitoring I2C/SPI interface (comparator family)
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
Total: $0.00 USD
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue
Ver detalhes da RFQ