MPX5050DP - 50kPa Differential Pressure Sensor 6-SIP | NXP
N.º da peça: MPX5050DP ✓ Ativo| Qtd. | Preço unitário | Total |
|---|---|---|
| 1 | $16.5 | $16,50 |
| 10 | $14.25 | $142,50 |
| 100 | $11.8 | $1.180,00 |
| 500 | $9.95 | $4.975,00 |
| 1.000 | $8.65 | $8.650,00 |
MPX5050DP Visão geral
A piezoresistive pressure sensor is a transducer that converts an applied pressure into a measurable electrical signal by exploiting the piezoresistive effect in silicon - the change in resistance of a diffused strain gauge when mechanical stress is applied to a silicon diaphragm. Within the broader sensor hierarchy, the MPX5050DP sits under MEMS sensors -> pressure sensors -> differential pressure sensors -> signal-conditioned pressure transducers. The integrated bipolar op-amp and thin-film resistor network on the die provide a temperature-compensated, calibrated output, eliminating the need for external analog signal-chain components in most applications.
Key features include a pressure range of 0 to 50 kPa differential, full-scale span of 4.5 V typical (0.2 V to 4.7 V), 5 V single-supply operation, sensitivity of 90 mV/kPa typical, accuracy of ±2.5% over 0C to 85C, and overpressure capability of 200 kPa. The 6-SIP package includes two parallel 4.93 mm (0.19") tubes for hose connection, simplifying mechanical integration in fluidic systems. Ratiometric output tracks supply voltage variations for noise-immune ADC reading.
Typical applications include HVAC blower and filter monitoring, automotive manifold absolute pressure sensing, medical respiratory instruments, industrial process control, level detection, and consumer appliance flow measurement. The dual-port differential configuration is particularly well suited to measuring pressure drop across flow restrictors, filters, and heat exchangers.
When designing with this device, ensure that the high-impedance Vout pin is buffered with an op-amp or fed directly to a microcontroller A/D input. Decouple VCC locally with 100 nF ceramic bypass, keep the pressure ports sealed to the reference atmosphere on the low side, and avoid exposing the die to condensing humidity or condensing air conditions. The tube-port orientation simplifies pneumatic plumbing but requires a small PCB cutout or off-board mounting to provide port access.
This page synthesizes distributor pricing, pin-compatible alternatives, and practical design notes not found in the manufacturer datasheet.
Alternativas drop-in para MPX5050DP — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Variantes desta série
Modelos da mesma série compatíveis como drop-in com MPX5050DP (mesmo formato e footprint) — diferindo em Operating Temperature, Mounting Type, Output Type, Package, Technology.
Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:
MPX5050GP
✅ Drop-In✓ Em estoque
$7.85 / unidade
Ver ficha técnica →MPXV5050GP
✅ Drop-In✓ Em estoque
$10.66 / unidade
Ver ficha técnica →MPX5010DP
✅ Drop-In✓ Em estoque
$9.6 / unidade
Ver ficha técnica →MPX5100DP
✅ Drop-In✓ Em estoque
$12.03 / unidade
Ver ficha técnica →XGZP6895A-050KPD
✅ Drop-In📋 Alternativa de referência (fora do catálogo)
MPX5700DP
✅ Drop-In✓ Em estoque
$9.2 / unidade
Ver ficha técnica →MPX5050DP Classificações máximas e características elétricas
| Manufacturer | NXP Semiconductors |
| Tipo de sensor | Differential Pressure Sensor |
| Operating Principle | Piezoresistive (MEMS silicon) |
| Pressure Range | 0 kPa to 50 kPa (0 PSI to 7.25 PSI) |
| Pressure Port Type | Differential, dual tube port (Male, 0.19" / 4.93 mm Tube) |
| Tipo de saída | Analog ratiometric voltage |
| Faixa de tensão de saída | 0.2 V to 4.7 V |
| Full-Scale Span | 4.5 V typical |
| Tensão de alimentação | 5.0 V nominal (4.75 V to 5.25 V) |
| Sensitivity | 90 mV/kPa typical |
| Response Time | 1 ms typical |
| Overpressure Rating | 200 kPa |
| Temperatura de operação | -40C to +125C |
| Encapsulamento | 6-SIP Module (SOT1693-1 / Case 1351-01) |
| Tipo de montagem | Through-Hole (with dual pressure ports) |
| Status RoHS | Compliant |
Configuração de pinos do MPX5050DP
| Pino 1 | GND — Ground reference |
| Pino 2 | Vout — Analog ratiometric output (0.2 V to 4.7 V) |
| Pino 3 | VCC — +5 V supply input |
| Pino 4 | NC — Not connected (no internal bond) |
| Pino 5 | Port 1 (+) — Differential pressure port 1 (high side, 0.19" tube) |
| Pino 6 | Port 2 (-) — Differential pressure port 2 (low side, 0.19" tube) |
Aplicações típicas
MPX5050DP é adequado para 6 aplicaçãos: HVAC Blower and Filter Monitoring, Automotive Manifold Pressure Sensing, Medical Respiratory and CPAP Monitoring, Industrial Process Control and Flow Monitoring, Liquid Level and Tank Measurement, Consumer Appliance Flow and Pressure Feedback.
HVAC Blower and Filter Monitoring
The MPX5050DP's 0-50 kPa range captures the full pressure spectrum of HVAC duct and filter drop applications, while its dual differential ports let it directly sense pressure drop across a filter or heat-exchanger coil with two simple hose taps. The 0.2 V to 4.7 V analog output interfaces directly to a microcontroller ADC without external op-amp conditioning, reducing BOM cost. The 90 mV/kPa sensitivity provides 5.5-bit usable resolution over a 10-bit ADC when the full 50 kPa span is used, sufficient for filter-loading detection and blockage alerts. Compared to differential pressure switches, the analog output enables variable threshold detection for predictive maintenance algorithms.
Recomendado
Automotive Manifold Pressure Sensing
The MPX5050DP's automotive-grade operating range of -40C to +125C and ratiometric 5 V output make it a strong candidate for engine control unit (ECU) manifold absolute pressure (MAP) signal reference and vacuum monitoring when paired with a reference-side port. The on-chip temperature compensation keeps the output within tolerance across underhood temperature swings without external trim, simplifying ECU firmware calibration. The 200 kPa overpressure rating survives turbo boost spikes that would damage lower-pressure sensors, providing a 4x safety margin. The dual-port differential configuration supports both absolute (gauge-reference) and differential (across-restrictor) sensing topologies with the same SKU.
Recomendado
Medical Respiratory and CPAP Monitoring
The MPX5050DP's 0-50 kPa range comfortably covers typical CPAP/BiPAP therapeutic pressures (4-20 cm H2O is 0.4-2 kPa, well within the sensor's range) with substantial headroom for fault-event detection. The ratiometric 5 V analog output allows direct connection to the safety-critical pressure channel of a respiratory device's analog front end, where its 1 ms response time supports real-time breath cycle monitoring. The integrated signal conditioning and temperature compensation remove the need for an external instrumentation amplifier that would otherwise introduce drift into the patient-pressure reading. Note that system-level medical device qualification (FDA, CE MDR, ISO 13485) remains the integrator's responsibility and is not implied by the sensor alone.
Recomendado
Industrial Process Control and Flow Monitoring
The MPX5050DP's dual-port differential input is purpose-built for measuring pressure drop across an orifice plate, venturi, or flow element in industrial flow meters. Placing the sensor across the primary element converts flow rate into a measurable differential pressure, with the 90 mV/kPa sensitivity providing useful resolution across typical 1-40 kPa flow spans. The robust 200 kPa overpressure tolerance handles water hammer and process upset events common in liquid flow systems. The dual parallel 4.93 mm tubes accept standard pneumatic push-fit fittings, eliminating custom port adapters and reducing installation labor in factory automation panels.
Recomendado
Liquid Level and Tank Measurement
The MPX5050DP can be configured as a hydrostatic level sensor by referencing one port to the liquid head and the other to atmosphere, with the differential pressure output proportional to the head height of the liquid column. The 0-50 kPa range covers water columns up to about 5 meters, suitable for most small to mid-size chemical tanks, coolant reservoirs, and water storage tanks. The on-chip signal conditioning removes the need for a separate instrumentation amplifier at the tank probe, simplifying intrinsically safe (IS) barrier implementation. The through-hole 6-SIP package installs on the tank-top enclosure bulkhead with the tubes penetrating into the tank and reference environment.
Recomendado
Consumer Appliance Flow and Pressure Feedback
The MPX5050DP integrates into consumer appliances such as washing machines, dishwashers, and water heaters for inlet-pressure verification, pump-flow verification, and filter-blockage detection. The 0.2 V to 4.7 V ratiometric output feeds directly to the appliance's main microcontroller ADC without a precision op-amp, minimizing BOM cost in cost-sensitive consumer markets. The robust 200 kPa overpressure rating survives pressure spikes from solenoid valve closures, and the -40C to +125C operating range handles under-counter and utility-room environments. The dual-port differential input lets one device sense across a filter element AND verify inlet water pressure without two separate sensors.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para MPX5050DP — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | MPX5050GP | MPXV5050GP | MPX5010DP | MPX5100DP | XGZP6895A-050KPD |
|---|---|---|---|---|---|---|
| Package | 6-SIP Module (Case 1351-01) | 6-SIP Module (Case 1351-01) - same | 6-SIP Module (Case 1351-01) - same | 6-SIP Module (Case 1351-01) - same | 6-SIP Module (Case 1351-01) - same | 6-SIP Module (compatible) - same |
| Brand | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | CFSensor |
| Pressure Range | 0 to 50 kPa | 0 to 50 kPa | 0 to 50 kPa | 0 to 10 kPa | 0 to 100 kPa | 0 to 50 kPa |
| Pressure Port Type | Differential, dual tube | Gauge, single tube | Gauge, single tube | Differential, dual tube | Differential, dual tube | Differential, dual tube |
| Sensitivity | 90 mV/kPa | 90 mV/kPa | 90 mV/kPa | 450 mV/kPa | 45 mV/kPa | 90 mV/kPa typical |
| Supply Voltage | 5 V | 5 V | 5 V | 5 V | 5 V | 5 V (3.3 V option) |
| Output Voltage Range | 0.2 V to 4.7 V | 0.2 V to 4.7 V | 0.2 V to 4.7 V | 0.2 V to 4.7 V | 0.2 V to 4.7 V | 0.2 V to 4.7 V |
| Operating Temperature | -40C to +125C | -40C to +125C | -40C to +125C | -40C to +125C | -40C to +125C | -40C to +85C typical |
| Approx. Unit Price (qty 1) | $16.50 | $16.00 | $15.50 | $14.00 | $17.00 | $8 to $12 typical |
Principais diferenciais
- Dual-tube differential pneumatic interface (no external port adapter needed) (vs MPX5050GP)
- Five-times wider pressure range with same output span (vs MPX5010DP)
- Cross-brand drop-in alternative exists at lower cost (vs XGZP6895A-050KPD (CFSensor))
- Through-hole assembly with integral port tubes (vs MPXV5050GP)
Notas de projeto
The MPX5050DP requires a clean, regulated 5 V supply within 4.75 V to 5.25 V for the ratiometric output to maintain specified accuracy. Place a 100 nF ceramic bypass capacitor as close as practical to the VCC pin (pin 3), with an additional 10 uF bulk decoupling capacitor on the same supply rail. Although the output is ratiometric and tracks supply variations, decoupling ensures the sensor's internal bandgap reference is not corrupted by digital switching noise that may ride on shared supplies.
The MPX5050DP 6-SIP module requires a PCB cutout or off-board mounting to provide access to the dual pressure ports. Do not place signal traces under or near the ports to avoid contamination from pneumatic leaks, and route the high-impedance Vout pin (pin 2) away from digital clock signals and switching regulator nodes. Place a buffer op-amp (e.g., MCP6001 or similar low-offset amplifier) close to the sensor output if the ADC is more than a few centimeters away, to prevent capacitive loading from degrading the output signal.
Avoid exposing the MPX5050DP die to condensing humidity, condensing air, or direct water spray: the sensor is rated for non-corrosive gas and dry air per NXP. The dual pressure ports share a common acoustic path through the sensor body, so a blocked or kinked tube on one side causes a pressure offset error that will look like a real pressure reading. Validate the pneumatic plumbing for leaks before calibrating, and consider adding a moisture filter or hydrophobic membrane to the high-pressure port in humid environments. Always vent the low-pressure port to true atmosphere (not the enclosure interior) for accurate gauge readings.
Informações de conformidade
RoHS and REACH compliant per NXP product page. Not AEC-Q100 qualified as a standalone sensor; AEC-Q100 qualification is at the system level. Halogen-free status not explicitly listed in the provided data.