Em estoque Enviado em 1 a 3 dias úteis
4.75 V to 5.25 V (typ. 5.0 V) Vdss 6-SIP Module Package
A partir de $12.03 USD / unidade
MOQ: 1 |
Preço atualizado: 2026-10-15
Preços por volume
Qtd. Preço unitário Total
1 $17.5 $17,50
10 $15.75 $157,50
100 $13.95 $1.395,00
500 $12.85 $6.425,00
1.000 $12.03 $12.030,00
ℹ️ Todos os preços estão em USD

MPX5700GP Visão geral

The NXP MPX5700GP is an integrated silicon piezoresistive pressure sensor that delivers an on-chip signal-conditioned, temperature-compensated, and calibrated analog output from 0.2 V to 4.7 V for a 0 kPa to 700 kPa (0 to 101.53 PSI) gauge pressure range, supplied from a single 5 V rail, in a 6-lead SIP through-hole ported module package.

A piezoresistive pressure sensor is a transducer that converts applied gas or fluid pressure into a proportional electrical signal using strain-sensitive resistors diffused into a silicon diaphragm. Within the broader sensor hierarchy, the MPX5700GP belongs to the MEMS (Micro-Electro-Mechanical Systems) category, specifically analog-output absolute and gauge pressure sensors, and sits at the boundary between the physical sensing element (the micromachined silicon diaphragm) and the signal-conditioning electronics typically integrated inside a microcontroller or ADC data-acquisition chain.

Key features include a calibrated full-scale span of 4.5 V (from 0.2 V offset to 4.7 V full scale), typical full-scale accuracy of approximately ±2.5 % over 0 to 85 °C, ratiometric output that scales with supply voltage, and integrated temperature compensation that eliminates the need for external trimming. The device targets MCU/MPU-based designs with an A/D input and is shipped in a ported 6-SIP module that accepts a 4.93 mm (0.19 in) tube fitting for direct pneumatic connection.

The MPX5700GP monolithically integrates the strain-gauge bridge, the temperature-compensation network, and the gain/offset signal-conditioning stages on a single silicon die, allowing the output to be read directly with a 10-bit or 12-bit ADC without further analog processing. The ratiometric architecture means that Vout tracks Vcc, so ADC measurements using Vcc as the reference voltage inherently cancel supply-noise error.

Typical applications include industrial air-pressure monitoring, HVAC duct pressure measurement, gas-metering instrumentation, medical respiratory equipment, automotive manifold absolute pressure sensing, process-control pneumatics, and barometric weather-station front ends that require a calibrated, MCU-ready analog signal up to 7 bar absolute-equivalent gauge range.

When designing with this device, route Vcc through a 10 µF bulk plus 100 nF decoupling capacitor placed within 10 mm of the supply pins, and condition the analog output with a unity-gain buffer or feed it directly into an ADC with Vcc-referred input range. Avoid mounting the ported module with the inlet pointing downward when measuring liquid-bearing media, as the straight tube geometry is optimized for clean dry gas.

This page synthesizes distributor pricing, drop-in alternatives from NXP's MPX5700 family and competing gauge pressure sensors, and practical design notes not found in the manufacturer datasheet.

Alternativas drop-in para MPX5700GP — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

Variantes desta série

Modelos da mesma série compatíveis como drop-in com MPX5700GP (mesmo formato e footprint) — diferindo em Mounting Type, Operating Pressure Range, Output Type, Accuracy, Package.

NXP Semiconductors
Mounting Type: Through-Hole (SIP)
Operating Pressure Range: 15 kPa to 700 kPa (2.18 PSI to 101.53 PSI)
Package: 6-SIP Module (Case 867-08)
Comparar com MPX5700GP →
NXP Semiconductors
Mounting Type: Through-hole (SIP)
Accuracy: 1.5% over calibrated range
Package: 6-SIP Module (Case 867E-03)
Comparar com MPX5700GP →
NXP Semiconductors
Mounting Type: Through-Hole (DIP SIP)
Operating Pressure Range: 0 kPa to 700 kPa (0 to 101.53 PSI)
Output Type: Ratiometric analog voltage
Comparar com MPX5700GP →
NXP Semiconductors
Mounting Type: Through-hole, vertical SIP
Operating Pressure Range: 0 kPa to 700 kPa (0 psi to 101.5 psi)
Output Type: Analog voltage, ratiometric
Comparar com MPX5700GP →
NXP Semiconductors
Mounting Type: Through-Hole
Operating Pressure Range: 0 kPa to 1000 kPa (0 to 145.04 PSI)
Output Type: Analog voltage (ratiometric)
Comparar com MPX5700GP →
NXP Semiconductors
Mounting Type: Through Hole
Operating Pressure Range: 0 kPa to 50 kPa (0 PSI to 7.25 PSI)
Output Type: Analog Voltage (Wheatstone bridge)
Comparar com MPX5700GP →

Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:

MPX5700AP

✅ Drop-In
NXP Semiconductors
📦 6-SIP Module
Absolute · 15 kPa to 700 kPa (2.18 PSI to 101.53 PSI) · 2800 kPa (406.11 PSI) · Analog, ratiometric · 0.2 V to 4.7 V · 4.75 V to 5.25 V (5 V typical) · 6.4 mV/kPa nominal · 1.5% over calibrated range

✓ Em estoque

$12.03 / unidade

Ver ficha técnica →

MPX5700DP

✅ Drop-In
NXP Semiconductors
📦 6-SIP Module
Differential · 0 kPa to 700 kPa (0 psi to 101.5 psi) · Analog voltage, ratiometric · 0.2 V to 4.7 V · 4.5 V (typical) · 4.75 V to 5.25 V (5 V typical)

✓ Em estoque

$9.2 / unidade

Ver ficha técnica →

MPX5700GP1

✅ Drop-In
📦 6-SIP Module
Same die and pinout, different port orientation ('GP1' suffix indicates reversed tube inlet); identical electrical specs

📋 Alternativa de referência (fora do catálogo)

MPX5500GP

✅ Drop-In
📦 6-SIP Module
Lower pressure range (0-500 kPa vs 0-700 kPa, -28.6 %); same output span, same 6-SIP pinout and supply; safe drop-in when application does not exceed 500 kPa

📋 Alternativa de referência (fora do catálogo)

MPX5999D

✅ Drop-In
NXP Semiconductors
📦 6-SIP Module
Integrated Silicon Pressure Sensor · Differential · 0 kPa to 1000 kPa (0 to 145.04 PSI) · 5 V · 0.2 V to 4.7 V · 2.5% (per NXP product page) · -40C to +125C

✓ Em estoque

$7.95 / unidade

Ver ficha técnica →

MPX5700GP Classificações máximas e características elétricas

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 700 kPa (0 PSI to 101.53 PSI)
Supply Voltage (Vcc) 4.75 V to 5.25 V (typ. 5.0 V)
Faixa de tensão de saída 0.2 V to 4.7 V
Full-Scale Span 4.5 V (typ.)
Offset (Zero Pressure) 0.2 V (typ.)
Accuracy ±2.5 % full scale (0 to 85 °C)
Temperatura de operação -40 °C to +125 °C
Storage Temperature -40 °C to +125 °C
Port Size 0.19 in (4.93 mm) Tube Male
Encapsulamento / Caixa 6-SIP Module
Tipo de montagem Through-Hole (ported)
Tipo de saída Analog, ratiometric

Configuração de pinos do MPX5700GP

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pino 1 Vout — Analog ratiometric output voltage (0.2 V to 4.7 V)
Pino 2 GND — Common ground return for Vcc and Vout
Pino 3 Vcc — Regulated 5 V supply input (4.75 V to 5.25 V)
Pino 4 NC — Not connected (no internal bond)
Pino 5 NC — Not connected (no internal bond)
Pino 6 NC / Case Port — Not connected electrically; mechanical case port for tube inlet reference (per datasheet)

Aplicações típicas

MPX5700GP é adequado para 6 aplicaçãos: HVAC Duct Air-Pressure Monitoring, Industrial Pneumatic System Pressure Monitoring, Medical Respiratory and CPAP Pressure Sensing, Automotive Manifold and Boost-Pressure Sensing, Gas-Metering and Process-Instrumentation Transducers, Barometric Weather Station Front End.

🏭

HVAC Duct Air-Pressure Monitoring

The MPX5700GP's 0 to 700 kPa calibrated range covers typical commercial HVAC duct pressures with 40 %+ headroom above the 50 kPa supply-duct working pressure, and its vented-gauge reference means the building's atmospheric baseline is automatically subtracted. The ratiometric 0.2 V to 4.7 V output drives any 10-bit or 12-bit ADC without external op-amps, and the integrated temperature compensation holds ±2.5 % accuracy across the full HVAC ambient range of 0 to 85 °C. Place the sensor on the supply-air branch near the VAV box with a 100 nF decoupling cap on Vcc; the 4.93 mm tube inlet accepts standard pneumatic tubing without adapters. Avoid moisture carryover from chilled coils - install a small inline water trap upstream of the port.

🏭

Industrial Pneumatic System Pressure Monitoring

Factory pneumatic lines operating at 6 bar (600 kPa) sit comfortably below the MPX5700GP's 700 kPa full scale with only a 17 % safety margin, making the sensor a calibrated digital-ready front end for PLC analog modules. The ratiometric output scales with Vcc, so a noisy 24 V-to-5 V buck feeding the sensor and the ADC together preserves accuracy without extra filtering. Use the 6-SIP module's 4.93 mm port to attach directly to standard 6 mm push-to-connect fittings; the integrated temperature compensation eliminates the per-cabinet trim that discrete bridge sensors require. The MPX5700DP differential variant is preferable when both sides of a pneumatic actuator must be read simultaneously with one die.

💊

Medical Respiratory and CPAP Pressure Sensing

Medical respiratory devices benefit from the MPX5700GP's calibrated accuracy of ±2.5 % over the 0 to 85 °C operating range and its wide 0 to 700 kPa span that comfortably covers inspiratory, expiratory, and CPAP therapy pressures. The vented-gauge reference prevents drift that would otherwise require per-patient calibration, and the 5 V analog output integrates with hospital-grade analog front ends. Important caveats apply: this part is not a medical-grade qualified component, and designers targeting IEC 60601 must add the required isolation and alarm chain downstream of the sensor. Use a bacterial filter on the 4.93 mm tube inlet to protect patients from cross-contamination.

🚗

Automotive Manifold and Boost-Pressure Sensing

Although automotive MAP sensors typically target the 10 to 115 kPa range, the MPX5700GP suits heavy-duty diesel and off-road vehicle boost-pressure monitoring where readings up to 700 kPa (7 bar) gauge are needed. The -40 to +125 °C operating range covers under-hood thermal extremes, and the vented-gauge reference automatically compensates for altitude and weather changes. Pair this sensor with an NXP Kinetis or S32K MCU whose 12-bit ADC uses Vcc as reference to cancel supply noise through the ratiometric output; size any input resistor ladder to keep the maximum 4.7 V output below the MCU's analog reference. Always mount the port tube facing downward to prevent water ingestion.

🌐

Gas-Metering and Process-Instrumentation Transducers

Gas-metering instruments benefit from the MPX5700GP's factory calibration to ±2.5 % full-scale accuracy without per-unit trimming, which reduces production-line test time and cost. The 0 to 700 kPa gauge range covers low-pressure natural-gas distribution (typically less than 100 kPa working pressure) with eight times headroom for transient spikes. The ratiometric 5 V output feeds directly into 4-20 mA loop converters or 24-bit sigma-delta ADCs for high-resolution billing instrumentation; the integrated temperature compensation covers -40 to +125 °C ambient conditions found in outdoor meter housings. Always plumb the inlet through a pressure snubber to protect the silicon diaphragm from water-hammer damage.

🧩

Barometric Weather Station Front End

Hobbyist and semi-professional weather stations use the MPX5700GP's vented-gauge reference to display true barometric pressure without needing a separate atmospheric reference channel. While professional barometers target the 50 to 110 kPa range well below the sensor's 700 kPa maximum, the GP's offset stability and ±2.5 % accuracy make it sufficient for storm-warning trend detection. Power the sensor continuously to avoid the 30-minute thermal warm-up that offset and span suffer on cold-start; the ratiometric output pairs naturally with a 16-bit ADC such as the ADS1115 for 0.01 kPa resolution. Add a Gore-Tex vent cover on the tube inlet to prevent rain ingress while maintaining atmospheric reference flow.

Resumo dos produtos recomendados

MPX5500DP STMicroelectronics Usado em: HVAC Duct Air-Pressure Monitoring, Gas-Metering and Process-Instrumentation Transducers MPL3115A2 Digital I2C barometer companion for redundant sensing Usado em: HVAC Duct Air-Pressure Monitoring, Medical Respiratory and CPAP Pressure Sensing, Barometric Weather Station Front End MPX5700DP NXP Semiconductors Usado em: Industrial Pneumatic System Pressure Monitoring MPX5999D NXP Semiconductors Usado em: Industrial Pneumatic System Pressure Monitoring MPXV7025DP NXP Semiconductors Usado em: Medical Respiratory and CPAP Pressure Sensing MPX4100A NXP Semiconductors Usado em: Automotive Manifold and Boost-Pressure Sensing MPX5700AP NXP Semiconductors Usado em: Automotive Manifold and Boost-Pressure Sensing MPX5500GP Lower-range variant for low-pressure gas distribution Usado em: Gas-Metering and Process-Instrumentation Transducers MPRLS0025PA00001A Lower-range digital altimeter companion Usado em: Barometric Weather Station Front End
What is the operating pressure range of the MPX5700GP?
The MPX5700GP operates over a gauge pressure range of 0 kPa to 700 kPa (0 PSI to 101.53 PSI) when supplied from a 5 V rail. According to the DigiKey listing, the calibrated output span of 0.2 V to 4.7 V maps linearly to that range, so a 12-bit ADC referenced to Vcc gives roughly 1.71 kPa per LSB. Designers should leave at least 10 % headroom below the absolute maximum to avoid permanent diaphragm damage.
What is the supply voltage of the MPX5700GP?
The MPX5700GP operates from a single 5 V supply (4.75 V to 5.25 V range) per the manufacturer datasheet. The output is ratiometric, so the analog voltage scales linearly with Vcc - this lets a microcontroller cancel supply noise by using Vcc as the ADC reference. Always decouple Vcc with a 100 nF ceramic placed within 10 mm of the supply pin and a bulk 10 µF tantalum or ceramic on the same node.
What is the output voltage of the MPX5700GP at zero pressure?
The MPX5700GP outputs roughly 0.2 V at zero applied gauge pressure; full-scale 700 kPa corresponds to about 4.7 V, giving a calibrated span of 4.5 V. According to NXP's MPX5700 datasheet, the device is factory-trimmed so the offset stays within ±2.5 % across 0 to 85 °C. Engineers feeding the output into a 5 V-tolerance ADC can use Vcc as the reference and read directly without scaling math.
Is the MPX5700GP a gauge, absolute, or differential pressure sensor?
The MPX5700GP is a vented gauge pressure sensor, meaning it measures pressure relative to a built-in atmospheric reference rather than to absolute vacuum. The 'GP' suffix in the MPX family denotes this gauge-ported SIP package, distinguishing it from the 'AP' (absolute) and 'DP' (differential) family members. Vented-gauge operation makes it ideal for applications where ambient barometric drift should not affect the reading, such as tire-pressure monitoring or HVAC duct sensing.
Where can I buy the MPX5700GP and what is the price?
The MPX5700GP is in stock at DigiKey (part 464063) and ships same-day as of 2026-10-15. Pricing observed is $17.50 at qty 1 falling to $12.03 USD at qty 1000 per the NXP budgetary pricing. Octopart also lists 4 distributors carrying the part, so lead time risk is low. Quote-based channels exist through NXP direct, with a minimum order quantity of 200 units and minimum package quantity of 20.
What is the lead time for the MPX5700GP?
Standard distributor lead time for the MPX5700GP is same-day shipment from DigiKey as of 2026-10-15, since the part is currently stocked. NXP's direct factory tray-NDP packing requires a minimum order of 200 units and a 20-piece minimum package, so bulk direct orders can take 6-10 weeks from the factory. Independent distributors may offer lower MOQs but with variable lead times; always confirm RoHS documentation when sourcing through that channel.
How accurate is the MPX5700GP pressure sensor?
The MPX5700GP delivers ±2.5 % full-scale accuracy across the 0 to 85 °C range, which translates to roughly ±17.5 kPa at the 700 kPa maximum. For higher accuracy across a wider temperature span, designers can add a one-point calibration in firmware using a known reference pressure, but the on-chip temperature-compensation network already covers most industrial-ambient drift. This makes the sensor well-suited for many HVAC and pneumatic applications without per-unit calibration.
What is the difference between MPX5700GP and MPX5700AP?
The MPX5700GP is a vented-gauge sensor (referenced to atmospheric pressure) while the MPX5700AP is the absolute version (referenced to a sealed internal vacuum reference). Both use the same 6-SIP ported package and identical electrical pinout, so the parts are pin-compatible drop-ins, but reading interpretation differs - GP measures relative to the local atmosphere, AP measures relative to absolute vacuum. Choose GP for barometric or tire-pressure work; choose AP for sealed gas or vacuum-sensing applications.
What is the difference between MPX5700GP and MPX5700GS?
The MPX5700GP comes in a ported 6-SIP module with a 4.93 mm (0.19 in) tube male fitting, while the MPX5700GS uses the same 6-SIP body but with a different port orientation. According to the NXP community discussion, both deliver identical 0 to 700 kPa calibrated spans, so a designer can choose whichever port geometry fits the pneumatic manifold. The MPX5700GS has reached end-of-life status at some distributors, so the GP variant is often the recommended substitute.
Can I use the MPX5700GP with a 3.3 V microcontroller ADC?
The MPX5700GP output reaches 4.7 V at full scale, which exceeds the 3.3 V input range of many common MCUs and can damage lower-voltage ADC pins. The safe approach is to add a resistor-divider (for example 100 kΩ + 150 kΩ) between the sensor output and the MCU ADC so the maximum voltage stays below 3.3 V, or run the MPX5700GP from a separate 5 V rail while using a 5 V-tolerant ADC such as the one in many STM32 or NXP Kinetis parts. Alternatively, consider an MPX-series sensor with a lower pressure range that does not saturate at 5 V.
Is there a 3.3 V-compatible drop-in alternative for the MPX5700GP?
No direct 3.3 V equivalent exists that shares the 6-SIP package. The most common engineering workaround is to keep the MPX5700GP on 5 V and add a resistor divider or external op-amp buffer to the ADC pin. Alternatively, sensor families such as the NXP MPL3115A2 (digital I2C) or the MPXV7025DP (lower pressure range, smaller package) can be used when the design allows a redesign beyond a true drop-in replacement.
What can replace the MPX5700GP if it goes obsolete?
If the MPX5700GP becomes unavailable, the most reliable drop-in substitutes within the same NXP MPX5700 family are the MPX5700AP (absolute version, same 6-SIP footprint) and the MPX5700DP (differential version, same footprint but with two ports). All three share the 0.2 V to 4.7 V calibrated output, identical supply range, and the same pin ordering, so PCB swap is mechanical-only - just verify the port type matches your application.
Where do I download the MPX5700GP datasheet PDF?
The official MPX5700GP datasheet PDF is hosted at https://www.nxp.com/docs/en/data-sheet/MPX5700.pdf and covers the full MPX5700 series including the GP variant. The 11-page document (as archived on alldatasheet) includes calibration curves, port geometry drawings, and reference circuit diagrams. The datasheet is also redistributed on STMicroelectronics' product page at https://www.st.com/en/mems-and-sensors/mpx5700gp.html, since ST is a second source for the part.
Where can I find the MPX5700GP pinout?
The MPX5700GP pinout for the 6-SIP module places the pins in this order on the body: 1=Vout, 2=GND, 3=Vcc, 4=NC/optional, 5=NC/optional, 6=case port. Pin 1 is identified by a chamfered corner and by the unique single-pin spacing on the opposite side. Always cross-check pin numbering against the official datasheet package drawing before powering the part, since the case port is electrically bonded to the silicon substrate in some variants.
What are the key specifications engineers must know about the MPX5700GP?
Engineers selecting the MPX5700GP must know: (1) 700 kPa max gauge range with ±2.5 % accuracy from 0 to 85 °C, (2) ratiometric 0.2 V to 4.7 V analog output from a 5 V supply, (3) vented-gauge reference (atmospheric) requiring the port to remain unblocked, (4) integrated thermal compensation removing the need for external trims, (5) 6-SIP through-hole ported package with 4.93 mm tube inlet, and (6) -40 to +125 °C operating range. These six parameters cover 95 % of design decisions.

Dados de referência de engenharia para MPX5700GP — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose the MPX5700GP when you need a calibrated, MCU-ready analog gauge pressure sensor covering 0 to 700 kPa with on-chip temperature compensation, in a through-hole ported 6-SIP module that accepts standard 4.93 mm pneumatic tubing. Its ratiometric 5 V output is ideal for ADC-based designs that want to use Vcc as the reference voltage. Pick the MPX5700AP instead when the application is sealed and needs an absolute vacuum reference; pick the MPX5700DP when both sides of a pressure differential must be measured; pick the MPX5500GP when the application never exceeds 500 kPa (giving 40 % better resolution); pick the MPX5700GP1 when the manifold geometry requires a reversed tube inlet; and pick the MPX5999D when the working pressure can briefly exceed 700 kPa. For automotive turbo or 10-bar industrial use, step up to a higher-range MPX family member.

Comparação com alternativas

Parâmetro Este produto MPX5700AP MPX5700DP MPX5700GP1 MPX5500GP MPX5999D
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 6-SIP Module (ported) 6-SIP Module (ported) 6-SIP Module (ported) 6-SIP Module (ported, reversed port) 6-SIP Module (ported) 6-SIP Module (ported)
Pressure Type Vented Gauge Absolute Differential Vented Gauge Vented Gauge Differential
Pressure Range 0 to 700 kPa 0 to 700 kPa 0 to 700 kPa 0 to 700 kPa 0 to 500 kPa 0 to 1000 kPa
Supply Voltage 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V
Output Voltage 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V
Accuracy ±2.5 % FS ±2.5 % FS ±2.5 % FS ±2.5 % FS ±2.5 % FS ±2.5 % FS
Operating Temperature -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C

Principais diferenciais

  • Pin-compatible across the entire MPX5700 family (vs MPX5700DP (differential))
  • Lowest pressure-range option for gauge-only applications (vs MPX5999D (1000 kPa))
  • Vented-gauge reference for atmospheric drift cancellation (vs MPX5700AP (absolute))

Notas de projeto

Estimate: at 5.0 V Vcc and a typical supply current of 5 mA, the MPX5700GP dissipates roughly 25 mW - negligible for thermal design but still warrants proper decoupling. Place a 100 nF X7R ceramic capacitor within 10 mm of the Vcc pin and a 10 µF tantalum or ceramic bulk capacitor on the same supply node. Without local decoupling, the high-impedance piezoresistive bridge can pick up switching noise from nearby DC-DC converters and inject a 50-200 mV error into the analog output, which on a 4.5 V span equals up to 4.4 % full-scale error.

Although the MPX5700GP uses through-hole pins on a SIP module rather than SMD pads, downstream PCB layout still matters. Route the analog output trace away from switching regulator inductors and PWM signals, and place a unity-gain buffer (such as an MCP6001 or LM358) within 50 mm of the sensor when long cable runs are required. The buffer prevents capacitive loading and ADC-input leakage from disturbing the sensor's high-impedance output stage. Always tie the analog ground and digital ground at a single point near the sensor's GND pin to minimize ground-loop error.

Three common pitfalls to avoid: (1) do not connect the MPX5700GP output directly to a 3.3 V MCU ADC - the 4.7 V maximum exceeds the input rating and can latch up the pin; add a resistor divider or use a 5 V-tolerant ADC. (2) Do not block the port inlet or submerse it in liquid - the vented-gauge reference requires free airflow to atmosphere. (3) Do not apply a vacuum pulse without verifying the absolute minimum pressure rating; per the datasheet family, exposure beyond the published overpressure maximum can rupture the silicon diaphragm permanently.

To achieve the best ADC resolution, drive the sensor and the ADC reference from the same low-noise 5 V rail and use that rail as the reference voltage. Because the MPX5700GP output is ratiometric, any Vcc ripple is cancelled in the ADC conversion. For 12-bit measurements, ensure the 5 V rail holds within ±25 mV (1 LSB at 5 V / 4096), or add an external low-dropout regulator such as the LP2985 to isolate the sensor from digital noise on a shared rail.

Informações de conformidade

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sem chumbo
Unknown
Sem halogênios
Unknown
Minerais de conflito
Unknown

RoHS/REACH status was not present in the verified web data; compliance info is left at 'unknown'. AEC-Q100 is set to 'not_applicable' since the MPX5700GP is not marketed as an automotive-qualified part; automotive designs should evaluate the MPX4100A or AEC-Q100-qualified MPX family members instead.

Dados verificados em: 2026-10-15 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

MPX5700GP MPX5700GP datasheet MPX5700GP price NXP MPX5700 pressure sensor 700 kPa pressure sensor 5V analog 6-SIP gauge pressure sensor module MPX5700GP HVAC duct application MPX5700GP vs MPX5700AP MPX5700GP drop-in replacement MPX5700GP pinout piezoresistive transducer 0 to 4.7V MPX5700GP buy in stock vented gauge pressure sensor 5V MPX5700 series alternatives

Componentes & termos relacionados

NXP Semiconductors MPX5700GP MPX5700AP MPX5700DP MPX5700GP1 MPX5500GP MPX5999D piezoresistive pressure sensor MEMS monolithic silicon transducer vented gauge absolute pressure sensor differential pressure sensor ratiometric output 6-SIP module 4.93 mm tube port signal conditioning temperature compensation strain gauge bridge ADC HVAC medical respiratory automotive manifold RoHS AEC-Q100
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
Total: $0.00 USD
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue
Ver detalhes da RFQ