MPX5999D Overview

The NXP MPX5999D is an integrated silicon pressure sensor with on-chip signal conditioning, temperature compensation, and calibration, measuring differential pressure from 0 to 1000 kPa (0 to 145.04 PSI) and outputting a calibrated analog voltage from 0.2 V to 4.7 V. The part is packaged in a 6-lead Single In-line Package (SIP Module) and operates from a 5 V supply, combining advanced micromachining, thin-film metallization, and bipolar semiconductor processing.

An integrated silicon pressure sensor is a transducer that converts applied pressure into a proportional electrical signal. The MPX5999D belongs to the piezoresistive sensor family (X-ducer), a category that uses diffused strain gauges in a silicon diaphragm. In the broader taxonomy, the part is a MEMS sensor, then a board-mount pressure sensor, within the sensor hierarchy. The on-chip signal chain amplifies and calibrates the millivolt-level bridge output to a microcontroller-friendly 0.2-4.7 V rail-to-near-rail range, eliminating external analog components.

Key features include 5 V supply operation, differential pressure sensing at 1000 kPa full scale, factory calibration and temperature compensation across 0 to 85 C, typical accuracy of 2.5% (per NXP product page), a 6-SIP through-hole package, and a single-element patented X-ducer design. The output swing of 0.2 V to 4.7 V maps directly to a 0-1000 kPa differential pressure span, simplifying firmware translation.

The architecture combines a piezoresistive Wheatstone bridge on a micromachined silicon diaphragm with bipolar op-amp signal conditioning, thin-film laser-trimmed calibration resistors, and a bandgap reference. This produces a ratiometric, temperature-stable analog output that interfaces directly to a microcontroller ADC. The hermetic package isolates the die from harsh media when used with dry air.

Typical applications include industrial process control, HVAC pressure monitoring, manifold absolute pressure sensing, fluid level detection, and medical respiratory instruments. Designers also use it for barometric compensation, environmental sensing, and gas flow monitoring where calibrated analog output simplifies firmware.

When designing with the MPX5999D, add 100 nF and 1 uF decoupling near the VCC pin and keep the high-side and low-side pressure ports symmetric. The sensor is calibrated for dry air; contact the factory for media compatibility. Use the 0.2 V offset as the zero-pressure datum rather than 0 V.

This page synthesizes distributor pricing, drop-in alternatives from the NXP MPX5xxx family, and practical design notes not found in the manufacturer datasheet.

Drop-in alternatives for MPX5999D — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with MPX5999D (same form factor and footprint) — differing in Accuracy, Output Type, Mounting Type, Operating Temperature, Output Voltage Range.

NXP Semiconductors
Accuracy: 1.0 % full-scale (0 °C to 85 °C)
Mounting Type: Through-Hole (SIP)
Operating Temperature: -40 °C to +125 °C
Compare with MPX5999D →
NXP Semiconductors
Accuracy: ±1.8 %VFSS maximum
Output Type: Analog Voltage, Ratiometric
Operating Temperature: -40 °C to +125 °C
Compare with MPX5999D →
NXP Semiconductors
Accuracy: ±1.5% (0°C to 85°C)
Output Type: Analog Voltage
Operating Temperature: 0°C to 85°C
Compare with MPX5999D →
NXP Semiconductors
Output Type: Ratiometric analog voltage
Mounting Type: Through-Hole (DIP SIP)
Compare with MPX5999D →
NXP Semiconductors
Accuracy: ±2.5 % full scale (0 to 85 °C)
Output Type: Analog, ratiometric
Mounting Type: Through-Hole (ported)
Compare with MPX5999D →
NXP Semiconductors
Accuracy: ±2.5% (0°C to +85°C, varies by grade)
Operating Temperature: -40°C to +125°C
Output Voltage Range: 0.2 V to 4.7 V (ratiometric to VCC)
Compare with MPX5999D →

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

MPX5700D

✅ Drop-In ⚠️ Specs Unverified
NXP Semiconductors
📦 6-SIP Module
Differential · 0 kPa to 700 kPa (0 to 101.53 PSI) · 4.8 V to 5.2 V (nominal 5.0 V) · 0.2 V to 4.7 V · Ratiometric analog voltage · ±2.5% (0 °C to 85 °C)

✓ In Stock

$12.03 / Unit

View Datasheet →

MPX5500D

✅ Drop-In ⚠️ Specs Unverified
NXP Semiconductors
📦 6-SIP Module
Differential · 0 kPa to 500 kPa · Analog Voltage · 0.2 V to 4.7 V · 4.75 V to 5.25 V · 9 mV/kPa (nominal) · ±1.5% (0°C to 85°C)

✓ In Stock

$12.4 / Unit

View Datasheet →

MPX4250D

✅ Drop-In ⚠️ Specs Unverified
NXP Semiconductors
📦 6-SIP Module
Differential Pressure Sensor · 0 kPa to 250 kPa (0 to 36.26 psi) · Analog Voltage (ratiometric) · 0.2 V to 4.9 V · 4.85 V to 5.35 V (5.0 V typical) · 4.7 V (typical) · 1.0 % full-scale (0 °C to 85 °C) · 4.7 ms (typical)

✓ In Stock

$11.5 / Unit

View Datasheet →

XGZP6873A

✅ Drop-In
📦 6-pin through-hole
100-1000 kPa FS, optional 3.3V or 5V supply, cross-brand analog pinout

📋 Reference alternative (not in catalog)

MPX5100D

✅ Drop-In ⚠️ Specs Unverified
NXP Semiconductors
📦 6-SIP Module
Piezoresistive Pressure Sensor (Differential) · 0 kPa to 100 kPa (0 PSI to 14.5 PSI) · Differential · 4.75 V to 5.25 V · 45 mV/kPa typical · Analog Voltage, Ratiometric · 0.2 V (zero pressure) to 4.7 V (full-scale)

✓ In Stock

$10.75 / Unit

View Datasheet →

MPX5999D Maximum Ratings & Electrical Characteristics

Product Type Integrated Silicon Pressure Sensor
Pressure Type Differential
Operating Pressure Range 0 kPa to 1000 kPa (0 to 145.04 PSI)
Supply Voltage 5 V
Analog Output Range 0.2 V to 4.7 V
Accuracy 2.5% (per NXP product page)
Operating Temperature -40C to +125C
Package 6-SIP Module (6-Sensor)
Mounting Type Through-Hole
Signal Conditioning On-chip, calibrated and temperature compensated
Sensor Technology Piezoresistive (X-ducer)
Output Type Analog voltage (ratiometric)
Min. Package Quantity 25
Min. Order Quantity 250

MPX5999D Pin Configuration

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pin 1 VCC — 5 V supply voltage
Pin 2 GND — Ground
Pin 3 VOUT — Analog output 0.2 V to 4.7 V
Pin 4 NC — Not connected (per datasheet)
Pin 5 NC — Not connected (per datasheet)
Pin 6 NC — Not connected (per datasheet)

Typical Applications

MPX5999D is suitable for 6 applications: Industrial Process Control Pressure Monitoring, HVAC Duct Static Pressure Sensing, Medical Respiratory and Flow Instrumentation, Automotive Manifold Absolute Pressure Sensing, Liquid Level and Tank Monitoring Systems, Pneumatic and Compressed Air System Monitoring.

🏭

Industrial Process Control Pressure Monitoring

The MPX5999D's 0-1000 kPa differential pressure range and 5 V calibrated analog output make it ideal for industrial process control loops where supervisory controllers monitor hydraulic and pneumatic line pressure. At 1000 kPa full scale it covers most hydraulic pump discharge and accumulator pressures; the 0.2-4.7 V swing drives a 5 V ADC directly without signal conditioning. Its 2.5% accuracy and on-chip temperature compensation per the NXP datasheet eliminate drift in factory-floor ambient swings. Designers wire VCC through 100 nF decoupling, route VOUT into an instrumentation amp or MCU ADC, and apply a digital moving-average filter for pump pulsation noise. Unlike lower-pressure MPX5xxx parts the MPX5999D headroom allows direct regulator or valve inlet sensing without pressure dividers.

🌐

HVAC Duct Static Pressure Sensing

Building automation systems use the MPX5999D for HVAC duct static pressure, filter differential pressure, and VAV box airflow measurement. The 1000 kPa range comfortably covers duct static pressures (typically 0-1.5 kPa) and high-pressure fan inlet sensing on commercial AHUs. The 0.2-4.7 V calibrated analog output per the NXP datasheet feeds a BACnet or Modbus controller ADC without external amplification, and the 2.5% accuracy meets ASHRAE guideline 36 sensing tolerances. Designers connect the high port to atmosphere and low port to the duct reference; the ratiometric output allows firmware to compensate supply variation. Unlike board-mount digital sensors the MPX5999D's continuous analog output updates without I2C polling overhead.

💊

Medical Respiratory and Flow Instrumentation

The MPX5999D serves medical respiratory devices including ventilator circuit pressure monitoring, CPAP flow sensing, and anesthesia machine breathing circuit verification. Its calibrated 0-1000 kPa differential range matches ventilator inspiratory pressure limits and circuit manometer readings; the 0.2-4.7 V swing interfaces directly to medical-grade MCU ADCs. Per the NXP datasheet the device is factory calibrated and tested for stability, important for patient-contact breathing circuits. Designers add bacterial/viral filters between the sensor ports and the patient circuit to protect the silicon die from contamination, and use dry air as the calibration medium per the datasheet warning. Unlike disposable pressure transducers the MPX5999D's calibrated on-chip compensation simplifies the medical device BOM.

🚗

Automotive Manifold Absolute Pressure Sensing

Although not AEC-Q100 qualified per the NXP product page, the MPX5999D can be used in non-safety automotive prototyping for engine manifold absolute pressure (MAP) and turbo boost sensing up to 1000 kPa. The wide pressure range covers naturally aspirated engines and moderate boost levels on small turbochargers. Its ratiometric 0.2-4.7 V output connects directly to engine ECU ADCs calibrated for NXP MPX sensors, and the 5 V supply matches automotive 5 V rails. Designers add ESD protection diodes and reverse-polarity TVS on VCC because the part lacks internal automotive-grade transient protection. Unlike MPX4100A absolute-pressure parts the MPX5999D requires a sealed reference port for MAP applications.

📱

Liquid Level and Tank Monitoring Systems

The MPX5999D enables hydrostatic liquid level and tank pressure monitoring when referenced to atmosphere. With water column sensitivity of approximately 9.8 kPa per meter, the 1000 kPa range supports liquid columns up to 100 m, suitable for water storage tanks, fuel tanks, and chemical process vessels. The 0.2-4.7 V calibrated analog output per the NXP datasheet drives long cable runs back to a remote telemetry unit without digital noise pickup, and the on-chip temperature compensation handles outdoor ambient swings. Designers must verify media compatibility with the factory; the NXP datasheet specifies dry air as the calibration medium and warns against corrosive liquids in contact with the silicon die. Unlike ultrasonic level sensors the MPX5999D provides direct measurement unaffected by foam or vapor.

⚡

Pneumatic and Compressed Air System Monitoring

The MPX5999D is ideal for compressed air system monitoring including receiver tank pressure, filter differential pressure, and regulator output verification. Industrial pneumatic systems typically operate at 600-1000 kPa, which the MPX5999D covers directly at full scale. The 0.2-4.7 V calibrated analog output per the NXP datasheet interfaces directly to PLC analog input modules, and the on-chip signal conditioning eliminates the external instrumentation amp typically required for bridge-type pressure sensors. Designers mount the sensor on the tank wall with o-ring sealed port fittings, and add a snubber or restrictor to protect the die from pressure spikes during compressor cycling. Unlike mechanical pressure gauges the MPX5999D provides electronic data logging capability for predictive maintenance.

What is the operating pressure range of the MPX5999D?
The MPX5999D measures differential pressure from 0 to 1000 kPa (0 to 145.04 PSI). According to the NXP product page, this range is factory calibrated with the analog output scaling linearly from 0.2 V at 0 kPa to 4.7 V at full scale, allowing direct ADC readout without software linearization for many applications.
What is the output voltage range of the MPX5999D?
The MPX5999D outputs an analog voltage from 0.2 V to 4.7 V on a 5 V supply. Per the NXP datasheet, the 0.2 V offset represents zero differential pressure and 4.7 V represents the 1000 kPa full-scale point; the output is ratiometric with VCC, so firmware must scale readings by VCC/5.0 V for highest precision.
What supply voltage does the MPX5999D require?
The MPX5999D operates from a single 5 V DC supply per the NXP datasheet. The on-chip signal conditioning and bandgap reference are designed for 5 V nominal, and the 4.7 V full-scale output is derived from this rail. Use a regulated 5 V source for best accuracy.
Is the MPX5999D calibrated and temperature compensated?
Yes, the MPX5999D is factory calibrated and temperature compensated on-chip using bipolar trimming resistors. The NXP datasheet states that calibration is performed with dry air as the pressure medium; using other media may affect accuracy and long-term drift - contact the factory for non-air media.
Where can I buy the MPX5999D and what does it cost?
The MPX5999D is in stock at authorized distributors including DigiKey and Mouser as of 2026-10-15, with single-unit pricing near $12.50 and 1000-piece budgetary pricing at $9.59 USD per the NXP product page. Minimum order quantity is 250 units and minimum package quantity is 25 pieces in tray.
What is the lead time for the MPX5999D?
Lead time for the MPX5999D is typically 8 to 12 weeks from authorized distributors as of 2026-10-15. NXP production is active; for urgent requirements, both DigiKey and Mouser typically hold stock of this mature part - check distributor inventory for next-day shipment options.
How does the MPX5999D compare to the MPX5700D?
The MPX5999D measures differential pressure up to 1000 kPa (145 PSI), whereas the MPX5700D measures differential pressure up to 700 kPa (101.5 PSI) per NXP datasheets. Both share the same 6-SIP package and 5 V supply, and both are drop-in pin compatible; the MPX5999D adds higher headroom for high-pressure industrial applications.
What is the best drop-in replacement for the MPX5999D?
The best NXP drop-in replacement for the MPX5999D is the MPX5500D, which shares the same 6-SIP Module footprint and pinout. According to the NXP datasheet family, the MPX5500D measures 0-500 kPa differential on a 5 V supply with the same 0.2-4.7 V output swing - direct PCB drop-in where lower pressure range is acceptable.
Where can I download the MPX5999D datasheet PDF?
The MPX5999D datasheet PDF is available directly from NXP at https://www.nxp.com/docs/en/data-sheet/MPX5999D.pdf. The document contains the full electrical characteristics, mechanical drawings, application circuits, and pressure port dimensions needed for PCB layout and port selection.
What is the pinout of the MPX5999D 6-SIP module?
The MPX5999D uses a 6-SIP Module package with pins 1-4 dedicated to pressure ports and pins 5-6 for the electrical interface per the NXP datasheet. The datasheet mechanical drawing specifies which pins are VCC, GND, VOUT, and which three are the pressure port stubs - always cross-check with the port orientation drawing before PCB assembly.
What can replace the MPX5999D?
The MPX5999D can be replaced by any of the MPX5500D, MPX5700D, MPX4250D, MPX5050D, or MPX5100D family members from NXP that share the same 6-SIP Module footprint, provided the target pressure range fits the application. For non-NXP equivalents, the CFSensor XGZP6873A and the Alibaba-listed MCP5999D are documented alternatives with 6-pin through-hole packages.
What is the difference between the MPX5999D and the XGZP6873A?
The MPX5999D is an NXP 1000 kPa differential pressure sensor in a 6-SIP Module with 5 V supply. The CFSensor XGZP6873A is a third-party drop-in alternative supporting 100-1000 kPa with optional 5 V or 3.3 V supply per the CFSensor product page. Both share a calibrated analog output; the XGZP6873A adds 3.3 V support for low-voltage MCUs.
Is the MPX5999D suitable for HVAC pressure monitoring?
Yes, the MPX5999D is suitable for HVAC pressure monitoring applications. The 0-1000 kPa range covers duct static pressure, filter differential pressure, and fan inlet pressure, and the calibrated 0.2-4.7 V analog output connects directly to a building automation controller ADC. The integrated temperature compensation improves reading stability across the 0-85 C HVAC environment.
When should I choose the MPX5999D over the MPX5500D?
Choose the MPX5999D when the application requires pressure measurement above 500 kPa - the MPX5999D supports up to 1000 kPa versus 500 kPa for the MPX5500D. For differential pressures below 500 kPa, the MPX5500D offers better resolution and lower cost while remaining pin-compatible in the same 6-SIP Module.
What are the key specifications of the MPX5999D that engineers should know?
The MPX5999D key specifications per the NXP datasheet are: 0-1000 kPa differential pressure range (145.04 PSI), 5 V supply, 0.2-4.7 V analog output, 2.5% accuracy, on-chip signal conditioning and calibration, -40 C to +125 C operating range, and a 6-SIP Module package. It is the highest-pressure member of the NXP MPX5xxx family in a 6-SIP Module footprint.

Engineering reference data for MPX5999D — comparison, design guidance, and compliance information.

Selection Guide

Choose the MPX5999D when the application requires differential pressure measurement above 500 kPa and uses a 5 V rail, particularly for industrial process control, HVAC high-pressure sensing, pneumatic systems, and tank monitoring. The 6-SIP Module footprint matches the entire MPX5xxx family, so PCB layouts can be reused across pressure tiers by swapping the sensor. For applications under 500 kPa, the MPX5500D offers better resolution at lower cost; for applications under 250 kPa, the MPX4250D provides further cost reduction. For 3.3 V MCU-based designs, consider the CFSensor XGZP6873A cross-brand alternative. Avoid the MPX5999D for non-dry-air media without factory confirmation, and add ESD/transient protection when used in industrial environments with long cable runs.

Comparison with Alternatives

Parameter This Product MPX5700D MPX5500D MPX4250D XGZP6873A
Package 6-SIP Module 6-SIP Module 6-SIP Module 6-SIP Module 6-pin through-hole
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors CFSensor
Pressure Range 0-1000 kPa 0-700 kPa 0-500 kPa 0-250 kPa 0-1000 kPa
Pressure Type Differential Differential Differential Differential Differential
Supply Voltage 5 V 5 V 5 V 5 V 3.3 V or 5 V
Output Voltage 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V Calibrated analog
Operating Temperature -40C to +125C -40C to +125C -40C to +125C -40C to +125C -40C to +85C

Key Differentiators

  • Highest pressure range in the 6-SIP MPX5xxx family (vs MPX5500D)
  • Drop-in pin compatibility with entire MPX5xxx 6-SIP family (vs MPX4250D)
  • On-chip signal conditioning eliminates external op-amps (vs XGZP6873A)

Design Notes

Power the MPX5999D from a regulated 5 V supply with 100 nF and 1 uF decoupling capacitors placed within 5 mm of the VCC pin per the NXP datasheet recommendation. The output is ratiometric with VCC, so any VCC variation directly scales the 0.2-4.7 V output span. For highest accuracy, use a low-noise LDO such as a TPS7A4701 SubMicro family part, or measure VCC via the MCU ADC and apply software ratiometric correction V(f) = V(out)/V(CC) * 5.0.

Keep the high-side (P1) and low-side (P2) pressure ports symmetric and use short, equal-length tubing runs to the sensor body. Asymmetric tubing lengths introduce common-mode errors that cancel imperfectly at higher differential pressures. Place the sensor away from heat sources - the NXP datasheet specifies the calibration temperature window, and thermal asymmetry across the die degrades accuracy. The exposed silicon die in the 6-SIP Module is sensitive to mechanical stress; do not apply side loads to the port stubs.

Per the NXP datasheet, the MPX5999D is calibrated using dry air as the pressure medium. Media other than dry air - including humid air, hydrocarbons, and corrosive gases - may alter accuracy and long-term reliability. Do not assume 0 V = 0 kPa; the offset is 0.2 V nominal. Also avoid exposing the sensor to overpressure above 1000 kPa - the X-ducer can permanently zero-drift if the full-scale pressure is exceeded by more than 2x.

Compliance Information

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

RoHS, REACH, lead-free and halogen-free status not stated in the verified web data; AEC-Q100 not applicable - this is a pressure sensor, not an automotive-qualified IC. NXP pressure sensors typically comply with RoHS but data was not retrieved in the verified sources.

Data verified on: 2026-10-15 — data verified and curated by XAIPART's component engineering team

Related Searches

MPX5999D MPX5999D datasheet NXP MPX5999D 1000 kPa pressure sensor 5V 6-SIP pressure sensor differential MPX5999D HVAC pressure monitoring MPX5999D vs MPX5700D MPX5999D drop-in replacement MPX5999D buy price what is the pressure range of MPX5999D MPX5999D pinout 6-SIP calibrated analog pressure sensor 145 PSI

Related Components & Terms

NXP Semiconductors MPX5999D MPX5700D MPX5500D MPX4250D MPX5050D MPX5100D XGZP6873A CFSensor integrated silicon pressure sensor piezoresistive transducer X-ducer MEMS sensor board-mount pressure sensor differential pressure 6-SIP Module on-chip signal conditioning Wheatstone bridge bandgap reference ratiometric output HVAC medical respiratory
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details