10 V typical (max per datasheet) Vdss M-PAC-5 (5-SMD module with top port) Package
A partir de $5.86 USD / unidade
MOQ: 1 |
Preço atualizado: 2026-10-15
Preços por volume
Qtd. Preço unitário Total
1 $7.92 $7,92
10 $7.13 $71,30
100 $6.34 $634,00
500 $5.86 $2.930,00
1.000 $5.86 $5.860,00
ℹ️ Todos os preços estão em USD

MPXM2202AS Visão geral

The NXP MPXM2202AS is a 200 kPa on-chip temperature-compensated silicon piezoresistive pressure sensor supplied in a 5-pin M-PAC top-port SMD module. It provides a differential analog output of 0 mV to 40 mV at 10 V excitation, sampling absolute pressure from 0 kPa to 200 kPa (0-29.01 PSI) through a 0.12" (2.97 mm) tube port. According to the NXP product listing, the device is packed in TUBE-TUBE MULTIPLE NDP with a minimum package quantity of 60 and minimum order quantity of 1200, at a budgetary price of $5.86 USD per 1k units.

A piezoresistive pressure sensor is a micro-electro-mechanical (MEMS) device in which a silicon diaphragm with diffused strain gauges converts applied pressure into a proportional change in resistance. The MPXM2202AS integrates the sensing die, on-chip temperature compensation network, and signal-conditioning resistors in a single surface-mount module, allowing direct interface to an external ADC or instrumentation amplifier. Within the broader sensor taxonomy, it sits as: pressure sensor -> MEMS sensor -> transducer -> sensor IC -> semiconductor. The MPX2202/MPXM2202 family is the legacy industrial/medical successor to the original Motorola MPX2000 series piezoresistive cells.

Key features include 0 mV to 40 mV full-scale output (typ. 0.2 mV/kPa sensitivity), 10 V typical excitation, on-chip temperature compensation across 0C to 85C, and an absolute pressure reference sealed inside the package. The 5-pin M-PAC package simplifies PCB layout compared to the larger unibody MPX2202GP variant, while preserving the same Wheatstone-bridge pinout. The sensor is intended for clean, dry, non-corrosive gases.

The MPXM2202AS relies on a single-axial piezoresistive bridge: four ion-implanted resistors on a silicon diaphragm form a Wheatstone configuration, balancing at 0 kPa and unbalancing linearly with applied pressure. The on-chip compensation network cancels the first-order temperature coefficient of the bridge, allowing raw mV output to be read directly with reasonable accuracy over the 0-85C range.

Typical applications include medical inhalers and patient monitors, HVAC pressure transmitters, altimeters and barometric instruments, industrial process control, and pneumatic system monitoring. For battery-powered designs, consider newer I2C/SPI digital sensors such as the NXP MPL3115A2 or the Bosch BMP280; the MPXM2202AS is best suited to systems that already have a stable 10 V analog supply and an ADC front end.

When designing with this part, route the high-impedance bridge outputs on a guard trace or shield and place the ADC sample-and-hold within 50 mm of the output pins. Apply the 10 V excitation through a low-noise LDO such as the TPS7A4701 to avoid bridge self-heating drift.

This page synthesizes distributor pricing, drop-in alternatives from the same NXP MPX2202 family, and practical design notes not found in the manufacturer datasheet.

Alternativas drop-in para MPXM2202AS — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

Variantes desta série

Modelos da mesma série compatíveis como drop-in com MPXM2202AS (mesmo formato e footprint) — diferindo em Operating Pressure Range, Output Type, Temperature Compensation, Package, Supply Voltage.

NXP Semiconductors
Operating Pressure Range: 14.5 PSI (100 kPa)
Output Type: Wheatstone Bridge (analog, differential)
Package: 5-SMD Module (MPAK)
Comparar com MPXM2202AS →
NXP Semiconductors
Operating Pressure Range: 0 to 100 kPa (0 to 14.5 PSI)
Output Type: Analog voltage (Wheatstone bridge, ratiometric)
Temperature Compensation: On-chip (calibrated 0C to 85C)
Comparar com MPXM2202AS →
NXP Semiconductors
Operating Pressure Range: 0 kPa to 100 kPa (0 to 14.5 PSI)
Temperature Compensation: On-chip (laser-trimmed)
Supply Voltage: 10 V typical (max 16 V)
Comparar com MPXM2202AS →
NXP Semiconductors
Operating Pressure Range: 0 kPa to 200 kPa (0 PSI to 29.01 PSI)
Output Type: Analog Wheatstone Bridge (mV output)
Temperature Compensation: On-chip, 0 C to +85 C
Comparar com MPXM2202AS →
STMicroelectronics
Operating Pressure Range: 0 kPa to 200 kPa (0 psi to 29.01 psi)
Output Type: Analog Wheatstone bridge (millivolt differential)
Temperature Compensation: On-chip, 0 °C to +85 °C
Comparar com MPXM2202AS →

Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:

MPXM2202A

✅ Drop-In
NXP Semiconductors
📦 M-PAC-5
Absolute · 0 kPa to 200 kPa (0 PSI to 29.01 PSI) · Analog Wheatstone Bridge (mV output) · 0 mV to 40 mV at 10V excitation · 10 V (typical) · 0 C to +85 C (calibrated)

✓ Em estoque

$5.3 / unidade

Ver ficha técnica →

MPXM2202GS

✅ Drop-In
📦 M-PAC-5
gauge (vented) reference vs absolute - same 0-40 mV/10 V output, same pinout

📋 Alternativa de referência (fora do catálogo)

MPXM2202GST1

✅ Drop-In
STMicroelectronics
📦 M-PAC-5
Vented Gauge · 0 kPa to 200 kPa (0 psi to 29.01 psi) · Analog Wheatstone bridge (millivolt differential) · 0 mV to 40 mV at 10 V excitation · ±0.25% (P2 grade) · 10 V typical (sensor excitation) · 0 °C to +85 °C (compensated range)

✓ Em estoque

$8.1 / unidade

Ver ficha técnica →

MPXM2202D

✅ Drop-In
📦 M-PAC-5
differential pressure reference vs absolute, same M-PAC-5 footprint, same 0-40 mV output

📋 Alternativa de referência (fora do catálogo)

MPXM2102A

✅ Drop-In
NXP Semiconductors
📦 M-PAC-5
Absolute Pressure · 14.5 PSI (100 kPa) · 58.02 PSI (400 kPa) · Wheatstone Bridge (analog, differential) · 0 mV to 40 mV (at 10 V excitation) · 10 V DC nominal · 0 kPa to 100 kPa absolute · No Port (board mount)

✓ Em estoque

$10.4 / unidade

Ver ficha técnica →

MPXM2102AS

✅ Drop-In
NXP Semiconductors
📦 M-PAC-5
Absolute · 0 to 100 kPa (0 to 14.5 PSI) · Analog voltage (Wheatstone bridge, ratiometric) · 0 mV to 40 mV typical (at 10 V excitation) · 0 mV · Up to 10 V DC

✓ Em estoque

$17.4 / unidade

Ver ficha técnica →

MPXM2102GS

✅ Drop-In
NXP Semiconductors
📦 M-PAC-5
Vented Gauge · 0 kPa to 100 kPa (0 to 14.5 PSI) · 0 mV to 40 mV at 10 V excitation · 10 V typical (max 16 V) · 0.4 mV/kPa nominal · Top-mounted tube (0.12" / 2.97 mm) · Single port, vented gauge · 5-SMD Module, M-PAC (MPAK-4)

✓ Em estoque

$4.35 / unidade

Ver ficha técnica →

MPXM2202AS Classificações máximas e características elétricas

Pressure Type Absolute
Operating Pressure Range 0 kPa to 200 kPa (0 to 29.01 PSI)
Tipo de saída Analog Wheatstone bridge (differential mV)
Full-Scale Output 0 mV to 40 mV at 10 V excitation
Sensitivity 0.2 mV/kPa (typical)
Supply Voltage (Excitation) 10 V typical (max per datasheet)
Faixa de temperatura de operação 0C to +85C (compensated)
Temperature Compensation On-chip (0C to +85C)
Encapsulamento M-PAC-5 (5-SMD module with top port)
Pressure Port Top port, 0.12 in (2.97 mm) tube
Tipo de montagem Surface Mount
Media Compatibility Dry, non-corrosive gases only

Configuração de pinos do MPXM2202AS

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pino 1 Vs+ — Bridge excitation positive (10 V typical)
Pino 2 Vout+ — Differential output positive (mV level)
Pino 3 Vs- — Bridge excitation negative (ground)
Pino 4 Vout- — Differential output negative (mV level)
Pino 5 GND — Package ground reference

Aplicações típicas

MPXM2202AS é adequado para 7 aplicaçãos: Medical Inhaler Pressure Monitoring, HVAC Duct Pressure Transmitter, Barometric Altimeter / Weather Station, Industrial Process Pressure Monitor, Pneumatic System Leak Testing, Patient Monitoring / Ventilator Side Stream, Gas Chromatograph Carrier Pressure Sense.

💊

Medical Inhaler Pressure Monitoring

The MPXM2202AS suits medical inhaler and respiratory equipment where 0-200 kPa absolute pressure reflects delivered lung pressure. Its 0.2 mV/kPa sensitivity and 10 V excitation produce a 40 mV full-scale signal that feeds directly into an instrumentation amplifier such as the INA128, preserving the dynamic range needed for breath-pattern analysis. The on-chip 0C-85C compensation eliminates external thermistor linearization, simplifying the analog front end.

🏭

HVAC Duct Pressure Transmitter

Building-automation HVAC duct-pressure monitoring benefits from the MPXM2202AS because 0-200 kPa covers typical duct static-pressure ranges while the absolute reference anchors against barometric drift. Its dry-gas compatibility suits clean supply-air ducts, and the M-PAC-5 top-port allows direct tube mounting into the duct wall. Pairing with a 4-20 mA loop transmitter such as the XTR105 completes the field-sensor chain for legacy BAS controllers.

✈️

Barometric Altimeter / Weather Station

Portable altimeters and weather stations use the MPXM2202AS because its 0-200 kPa absolute range covers sea-level (101.325 kPa) up to roughly 9 km altitude (below 30 kPa). The 0.2 mV/kPa sensitivity provides 0.5 m altitude resolution after 12-bit ADC conversion, sufficient for hiking and amateur weather-logging applications. Battery-powered systems should duty-cycle the 10 V excitation via a boost regulator to extend runtime.

🏭

Industrial Process Pressure Monitor

Industrial process-control loops in the 0-200 kPa range - including filter status monitoring, vacuum-line sensing, and cleanroom pressure verification - leverage the MPXM2202AS for its long-term silicon-diaphragm stability and on-chip temperature compensation. The 0-40 mV analog output interfaces directly to legacy 0-10 V PLC analog input modules via a single op-amp gain stage. The M-PAC-5 top-port accepts standard 2.97 mm tubing for pneumatic panel integration.

⚡

Pneumatic System Leak Testing

Pneumatic-system leak-test fixtures use the MPXM2202AS to monitor pressure decay in a sealed manifold between 0-200 kPa. Its absolute reference gives a stable baseline for comparison, and the 10 V excitation is supplied from the test fixture's existing high-voltage rail. The 5-pin M-PAC package handles manual insertion on the test fixture PCB, and the top port accepts the pneumatic coupling directly without additional fittings.

💊

Patient Monitoring / Ventilator Side Stream

Patient monitoring and ventilator side-stream pressure measurement at low flows uses the MPXM2202AS for its calibrated mV/kPa response and clean-gas compatibility. The 0-40 mV output is amplified by an instrumentation amp before being sampled by a 1 kSPS ADC, capturing breath waveform details down to 0.1 kPa resolution. The on-chip compensation reduces the calibration burden during ventilator QA cycles.

🧩

Gas Chromatograph Carrier Pressure Sense

Benchtop gas chromatographs use the MPXM2202AS to monitor carrier-gas line pressure up to 200 kPa during sample injection. Its analog mV output feeds a 24-bit sigma-delta ADC that captures both static pressure and short transients during valve actuation. The dry-gas-only media specification aligns with helium, hydrogen, and nitrogen carriers used in GC workflows.

Resumo dos produtos recomendados

INA128 Instrumentation amplifier for mV-level bridge output Usado em: Medical Inhaler Pressure Monitoring ADS1115 16-bit ADC for digitizing the amplified bridge signal Usado em: Medical Inhaler Pressure Monitoring XTR105 4-20 mA current loop transmitter for sensor signal Usado em: HVAC Duct Pressure Transmitter TPS7A4701 Low-noise LDO to power the 10 V excitation rail Usado em: HVAC Duct Pressure Transmitter MPL3115A2 I2C digital altimeter alternative for battery designs Usado em: Barometric Altimeter / Weather Station TPS61236P Boost converter to generate 10 V excitation from Li-ion Usado em: Barometric Altimeter / Weather Station OP07 Precision op-amp for bridge amplification Usado em: Industrial Process Pressure Monitor REF02 5 V reference for ADC excitation calibration Usado em: Industrial Process Pressure Monitor MAX4475 Low-noise op-amp for small delta-pressure amplification Usado em: Pneumatic System Leak Testing MAX232 RS-232 transceiver to log pressure data to a host PC Usado em: Pneumatic System Leak Testing ADS131A04 24-bit delta-sigma ADC for medical-grade sampling Usado em: Patient Monitoring / Ventilator Side Stream INA333 Low-power instrumentation amplifier for portable monitors Usado em: Patient Monitoring / Ventilator Side Stream ADS1256 24-bit ADC for high-resolution pressure capture Usado em: Gas Chromatograph Carrier Pressure Sense OPA227 Low-offset op-amp for downstream signal conditioning Usado em: Gas Chromatograph Carrier Pressure Sense
What is the operating pressure range of the MPXM2202AS?
The MPXM2202AS operates from 0 kPa to 200 kPa (0 to 29.01 PSI) absolute pressure. According to the NXP product page, the sensor delivers a linear 0 mV to 40 mV analog output across this range when excited at 10 V. The on-chip reference is sealed inside the package so 0 kPa corresponds to a perfect vacuum port (effective on-board absolute reference).
Is the MPXM2202AS still in production or has it been discontinued?
The MPXM2202AS is listed by NXP with an 'End of Life Overview' notice, indicating the part is at end-of-life. The page references 'Discontinuance and Replacement' under a Product Change Notice. Engineers designing new products should treat it as last-time-buy and evaluate pin-compatible MPXM2202 family members or digital I2C alternatives for new designs.
What is the best drop-in replacement for the MPXM2202AS?
The closest drop-in replacements are the MPXM2202A, MPXM2202GS, MPXM2202GST1, and MPXM2202D, all of which share the 5-pin M-PAC package and 0-40 mV/10 V output but vary in port style (top vs dual) and gauge vs absolute reference. Per the cross-reference data, these parts share the same pinout family and can typically be substituted after verifying the absolute vs differential reference.
What is the price of the MPXM2202AS?
The NXP budgetary price is $5.86 USD per 1,000-piece reel as listed on the manufacturer product page (as of 2026-10-15). Distributor pricing at 1-piece quantity has been observed near $7.92 USD at open-market stockists. Prices for EOL inventory can vary widely month-to-month, so request a current quote before placing volume orders.
Where can I download the MPXM2202AS datasheet PDF?
The MPXM2202AS datasheet is available on the official NXP product page at https://www.nxp.com/part/MPXM2202AS. The original datasheet document is also mirrored across distributor sites including DigiKey and third-party archives. The document covers pinout, bridge excitation, temperature compensation curves, and mechanical drawings for the M-PAC-5 package.
What is the difference between MPXM2202AS and MPXM2202GS?
The MPXM2202AS is an absolute-pressure sensor with a single top port, whereas the MPXM2202GS is a gauge-pressure sensor in the same 5-pin M-PAC family. Both share 0-40 mV/10 V output and 0-200 kPa range, but the absolute variant has an internal vacuum reference while the gauge variant vents to atmosphere through a second port. Choose AS for sealed absolute measurements and GS for relative pressure measurements.
What is the difference between MPXM2202AS and MPXM2102AS?
The MPXM2202AS has a 0-200 kPa operating range with 40 mV full-scale output, while the MPXM2102AS has a 0-100 kPa range with 20 mV full-scale output. Both share the same 5-pin M-PAC package, pinout, and 10 V excitation, but the MPXM2102AS has roughly half the sensitivity (0.2 mV/kPa at the lower range boundary vs 0.2 mV/kPa throughout for the 2202). They are not drop-in equivalents because the calibration constants change.
Can the MPXM2202AS be used with a 3.3V microcontroller?
The MPXM2202AS requires 10 V typical excitation, so a 3.3V microcontroller alone cannot power it. You must provide a boosted 10 V analog rail (e.g., from a small DC-DC followed by a low-noise LDO) and add an external ADC or instrumentation amplifier to digitize the millivolt output. For native 3.3V designs, choose a digital-output sensor such as the NXP MPL3115A2 or Bosch BMP280 instead.
What is the MPXM2202AS pinout?
The MPXM2202AS uses the standard NXP MPX2202 5-pin M-PAC pinout: pins 1 and 3 are the bridge excitation (+ and -), pins 2 and 4 are the differential mV signal output (+ and -), and pin 5 is ground. The pressure port sits on the top of the package. See the pinout diagram on this page for the exact mechanical arrangement.
What media can the MPXM2202AS sense?
The MPXM2202AS is specified for clean, dry, non-corrosive gases only. It is not compatible with water, fuels, or aggressive chemicals because the silicon die and on-chip compensation network are exposed to the media through the top port. For liquid or harsh-media sensing, add a compatible isolation diaphragm or use a media-isolated module such as the NXP MPX5700 series.
MPXM2202AS vs MPXM2102D - which should I choose?
Choose the MPXM2202AS for 0-200 kPa absolute pressure measurements and the MPXM2102D for 0-100 kPa differential pressure measurements. They share the same 5-pin M-PAC package and pinout, but the absolute vs differential reference and the pressure span differ. The 2202AS has higher full-scale output (40 mV vs 20 mV) and is preferred where 100-200 kPa coverage is required.
How does the on-chip temperature compensation work?
The MPXM2202AS integrates thin-film and ion-implanted resistors that compensate the bridge offset and span drift from 0C to +85C. The compensation network is trimmed at wafer probe to flatten the temperature coefficient of the zero-pressure offset and the full-scale span. Designers should still implement a software linearization if sub-1%FS accuracy is required across the full -40C to +125C automotive window.
Is the MPXM2202AS RoHS compliant?
The MPXM2202AS RoHS status was not directly confirmed in the verified web data; the NXP product page header does not include the green-compliance badge in the snippets provided. Treat compliance as 'unknown' until cross-checked against the latest PCN/EOL notice or a fresh distributor listing. New designs in RoHS-mandated regions should default to the lead-free MPXM2202ASR variant if available.
What is the lead time for the MPXM2202AS?
Lead time for the MPXM2202AS depends on stock because NXP has issued an EOL/PCN notice. Authorized distributors may show 0-12 weeks while inventory lasts, but once last-time-buy windows close, only the open market will have stock. As of 2026-10-15, open-market distributors such as Win Source and Sierra IC show the part with active RFQ options.
What is the difference between MPXM2202AS and MPXM2202GST1?
The MPXM2202AS is an absolute-pressure top-port sensor, while the MPXM2202GST1 is a gauge-pressure top-port sensor supplied on tape and reel (suffix T1). They share the same M-PAC-5 package, 0-40 mV output, and 10 V excitation, but the reference differs. They are pin-compatible but functionally different - confirm whether your design needs absolute (vacuum-referenced) or gauge (vented) pressure before substituting.

Dados de referência de engenharia para MPXM2202AS — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose the MPXM2202AS when you need a 0-200 kPa absolute pressure reading from a sealed M-PAC-5 top-port module with 10 V excitation and 0-40 mV analog output. It is the right pick for barometric instruments, ventilator side-stream monitoring, and HVAC duct static-pressure transmitters where an internal vacuum reference prevents drift. If your application vents to atmosphere, choose the MPXM2202GS instead (gauge). If you need only 0-100 kPa, choose the MPXM2102A for the same footprint but lower sensitivity to span. Avoid the MPXM2202AS for new high-volume designs because of the NXP EOL notice - consider the digital-output NXP MPL3115A2 for new 3.3 V native designs, or the MPXM2202A/GS family if staying within the analog MPX2202 lineage is required.

Comparação com alternativas

Parâmetro Este produto MPXM2202A MPXM2202GS MPXM2202GST1 MPXM2202D MPXM2102A
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package M-PAC-5 (5-SMD module) M-PAC-5 - same M-PAC-5 - same M-PAC-5 - same M-PAC-5 - same M-PAC-5 - same
Pressure Type Absolute Absolute Gauge Gauge Differential Absolute
Operating Pressure Range 0 to 200 kPa 0 to 200 kPa 0 to 200 kPa 0 to 200 kPa 0 to 200 kPa 0 to 100 kPa
Full-Scale Output 0 to 40 mV at 10 V 0 to 40 mV at 10 V 0 to 40 mV at 10 V 0 to 40 mV at 10 V 0 to 40 mV at 10 V 0 to 20 mV at 10 V
Sensitivity 0.2 mV/kPa 0.2 mV/kPa 0.2 mV/kPa 0.2 mV/kPa 0.2 mV/kPa 0.2 mV/kPa
Excitation Voltage 10 V typical 10 V typical 10 V typical 10 V typical 10 V typical 10 V typical
Port Style Top port, 0.12 in tube Axial port Top port Top port, tape-and-reel Dual port Axial port
Lifecycle Status Last-time-buy (EOL notice) Active Active Active Active Active

Principais diferenciais

  • Absolute pressure reference sealed inside the M-PAC module (vs MPXM2202GS)
  • Wider 200 kPa range vs 100 kPa alternatives (vs MPXM2102A)
  • Mature, broadly documented M-PAC-5 footprint (vs MPXM2202A (axial port variant))

Notas de projeto

The MPXM2202AS output is a differential mV-level signal on pins 2 and 4; route these traces as a guarded pair on inner PCB layers to reject common-mode noise. Keep traces shorter than 50 mm and place the instrumentation amplifier within 25 mm of the sensor to avoid picking up 50/60 Hz pickup. Twisted-pair cabling from the sensor to a remote amplifier is acceptable, but add a 10 nF bypass cap at the amplifier inputs.

Apply the 10 V excitation through a low-noise LDO such as the TPS7A4701 rather than directly from a switching converter. Bridge self-heating from ripple current shifts the zero-pressure offset; using an LDO with <5 uVrms output noise limits the drift contribution to under 0.01%FS. Estimate: a 5 mA excitation current and 10 V supply produces 50 mW dissipation at the bridge, well within thermal limits.

Despite on-chip 0C-85C temperature compensation, do not place the MPXM2202AS adjacent to power components. A 10C local temperature rise shifts the zero offset by up to 0.5%FS even with compensation. Mount the sensor on an isothermal copper pour separated from the rest of the board, and avoid forced-air heating from adjacent regulators.

Do not expose the MPXM2202AS to liquids or corrosive media - the silicon die is exposed to the gas through the top port. For water or fuel sensing, fit a media-isolated diaphragm in the pneumatic line. Also avoid miswiring pins 1 and 3 (excitation) - reversed polarity produces negative output that saturates downstream amplifiers without indicating a fault to software.

Informações de conformidade

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sem chumbo
Unknown
Sem halogênios
Unknown
Minerais de conflito
Unknown

Compliance flags not directly confirmed in the verified web data snippets. The NXP product page does not display the green-compliance badge in the retrieved excerpt, so RoHS/REACH status is set to 'unknown' pending direct datasheet verification. AEC-Q100 is not applicable because this is a sensor module, not an automotive-grade IC line.

Dados verificados em: 2026-10-15 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

MPXM2202AS MPXM2202AS datasheet PDF NXP MPXM2202AS pressure sensor 200 kPa absolute pressure sensor M-PAC MPXM2202AS M-PAC-5 pinout MPXM2202AS vs MPXM2202GS MPXM2202AS drop-in replacement buy MPXM2202AS online MPXM2202AS lead time EOL piezoresistive pressure sensor 10V excitation MEMS barometric sensor analog mV output what is the sensitivity of MPXM2202AS

Componentes & termos relacionados

NXP Semiconductors MPXM2202AS MPXM2202A MPXM2202GS MPXM2202GST1 MPXM2202D MPXM2102A MPXM2102AS MPXM2102GS piezoresistive pressure sensor MEMS sensor absolute pressure sensor Wheatstone bridge M-PAC-5 package MPX2202 family RoHS compliance EOL / last-time-buy barometric altimeter HVAC duct pressure medical ventilator instrumentation amplifier 10 V excitation rail temperature compensation
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
Total: $0.00 USD
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue
Ver detalhes da RFQ