NXP Semiconductors

MPXM2102GS - 100kPa Vented Gauge Pressure Sensor | NXP

MPN: MPXM2102GS ✗ End of Life
In Stock Ships in 1-3 business days
0 mV to 40 mV at 10 V excitation Vdss 5-SMD Module, M-PAC (MPAK-4) Package
From $4.35 USD / Unit
MOQ: 1 |
Price updated: 2026-10-15
Volume Pricing
Qty Unit Price Extended
1 $8.95 $8.95
10 $7.85 $78.50
100 $6.4 $640.00
500 $5.2 $2,600.00
1,000 $4.35 $4,350.00
ℹ️ All prices are in USD

MPXM2102GS Overview

The NXP MPXM2102GS is a 100 kPa piezoresistive silicon pressure sensor with a vented-gauge (Gage) topology, providing an analog output voltage proportional to applied pressure in a 5-pin M-PAC (MPAK-4) surface-mount module with a top-mounted tube port. According to NXP product information, the device outputs 0 mV to 40 mV at 10 V excitation over a 0 to 100 kPa pressure range, delivering a linear response suitable for direct ADC conversion after instrumentation amplification.

A piezoresistive pressure sensor is a solid-state transducer in which strain gauges diffused into a silicon diaphragm change resistance when the diaphragm flexes under pressure; the resulting Wheatstone bridge produces a differential voltage proportional to pressure. Piezoresistive pressure sensors sit in the transducer hierarchy: pressure sensor -> MEMS sensor -> sensor -> discrete semiconductor, and serve as the front-end element in medical, HVAC, and industrial instrumentation.

Key features of the MPXM2102GS include on-chip temperature compensation and calibration via laser-trimmed thin-film resistors, providing span and offset accuracy that minimizes external calibration circuitry. The single monolithic diaphragm with integrated strain gauge network ensures long-term stability and mechanical robustness. Operating pressure range is 0 to 100 kPa (approximately 0 to 14.5 PSI), with sensitivity near 0.4 mV/kPa at 10 V supply. The 5-pin M-PAC (MPAK-4) package with top port simplifies tubing connections in pressure test setups.

Typical applications include barometric and altitude measurement for weather monitoring stations, medical spirometers and non-invasive blood pressure monitors, HVAC differential pressure sensing, and industrial process control loops requiring accurate low-pressure measurement. The vented-gauge reference (port exposed to atmosphere through the package vent) makes the device ideal for applications where the measurement differential versus ambient pressure is the quantity of interest.

When designing with the MPXM2102GS, use an instrumentation amplifier such as INA333 or AD620 to amplify the millivolt-level output to a 0-5 V or 4-20 mA range; provide a stable low-noise 10 V excitation; and add adequate filtering on the supply to reject EMI. Do not apply pressure exceeding the rated 100 kPa range to avoid permanent diaphragm damage.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet, with all entries cross-referenced against NXP's product information page and DigiKey parametric data.

Drop-in alternatives for MPXM2102GS — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with MPXM2102GS (same form factor and footprint) — differing in Operating Pressure Range, Output Type, Package, Operating Temperature, Temperature Compensation.

NXP Semiconductors
Operating Pressure Range: 0 kPa to 10 kPa (0 to 1.45 PSI)
Output Type: Wheatstone Bridge (analog, differential mV)
Package: 5-SMD Module, top port
Compare with MPXM2102GS →
STMicroelectronics
Output Type: Wheatstone Bridge (analog, differential)
Package: 5-SMD Module, M-PAK (4 leads + Tab)
Operating Temperature: 0 °C to +85 °C (compensated)
Compare with MPXM2102GS →
NXP Semiconductors
Operating Pressure Range: 0 kPa to 100 kPa (0 psi to 14.5 psi)
Output Type: Analog Voltage (Wheatstone bridge, ratiometric)
Package: 5-SMD Module (M-PAK)
Compare with MPXM2102GS →
NXP Semiconductors
Operating Pressure Range: 0 kPa to 200 kPa (0 to 29.01 PSI)
Output Type: Analog Wheatstone bridge (differential mV)
Package: M-PAC-5 (5-SMD module with top port)
Compare with MPXM2102GS →
STMicroelectronics
Operating Pressure Range: 0 kPa to 200 kPa (0 psi to 29.01 psi)
Output Type: Analog Wheatstone bridge (millivolt differential)
Package: 5-SMD M-PAK module, top port
Compare with MPXM2102GS →

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

No drop-in alternatives available for this product.

Request Alternatives

MPXM2102GS Maximum Ratings & Electrical Characteristics

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 100 kPa (0 to 14.5 PSI)
Output Voltage 0 mV to 40 mV at 10 V excitation
Supply Voltage 10 V typical (max 16 V)
Sensitivity 0.4 mV/kPa nominal
Pressure Port Top-mounted tube (0.12" / 2.97 mm)
Port Configuration Single port, vented gauge
Package Type 5-SMD Module, M-PAC (MPAK-4)
Operating Temperature -40 C to +125 C
Technology Piezoresistive silicon strain gauge
Temperature Compensation On-chip (laser-trimmed)
Mounting Type Surface Mount
Diaphragm Single monolithic silicon
Series MPX2102
RoHS Status unknown

MPXM2102GS Pin Configuration

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pin 1 Vout+ — Positive bridge output (differential pressure signal, positive side)
Pin 2 GND — Ground reference
Pin 3 VS+ — Supply voltage (10 V typical)
Pin 4 Vout- — Negative bridge output (differential pressure signal, negative side)
Pin 5 NC / Tab — Not connected electrically; tab is mechanical pressure-port ground reference

Typical Applications

MPXM2102GS is suitable for 6 applications: Barometric Pressure & Altitude Sensing, Medical Spirometry & Respiratory Monitoring, HVAC Differential Pressure Sensing, Industrial Process Control Loops, Portable Altimeter & Wearable Devices, Automotive Manifold & MAP Sensing Reference.

🌐

Barometric Pressure & Altitude Sensing

The MPXM2102GS is well suited to barometric pressure and altitude measurement in weather stations, handheld GPS, and drones. Its 0 to 100 kPa vented-gauge range covers the full atmospheric pressure envelope from sea level (~101 kPa) to high altitude (~30 kPa at 9000 m). The on-chip temperature compensation keeps span and offset stable across -40 C to +125 C, which is critical for outdoor environmental monitoring where ambient temperature varies widely. The 0.4 mV/kPa nominal sensitivity at 10 V excitation, after amplification by an INA333 or AD620 instrumentation amplifier, delivers enough resolution for 0.1 kPa altitude-accuracy targets. The vented-gauge topology references against ambient through the top port, which is essential because absolute atmospheric pressure is the quantity of interest in weather and altitude applications.

💊

Medical Spirometry & Respiratory Monitoring

The MPXM2102GS fits medical spirometry and respiratory flow-pressure measurement where differential pressure is low and accuracy matters. The 0 to 100 kPa range covers typical breathing-circuit pressures, and the piezoresistive silicon diaphragm is small, lightweight, and inexpensive enough for single-use or low-cost reusable medical instruments. The on-chip temperature compensation reduces drift during warm-up and across body-temperature operating conditions. The vented-gauge configuration simplifies the medical circuit by referencing the patient-side ambient directly through the top port. An external instrumentation amplifier converts the 40 mV full-scale output to a 0-5 V signal for the ADC; the same signal chain supports both inspiratory and expiratory pressure monitoring.

🏭

HVAC Differential Pressure Sensing

The MPXM2102GS is a strong fit for HVAC duct and filter differential pressure measurement in building automation systems. The 100 kPa range easily covers typical duct static pressures of 0-2.5 kPa with substantial headroom for over-pressure events. Its on-chip temperature compensation across -40 C to +125 C tolerates rooftop and mechanical-room environments where ambient swings are large. The vented-gauge topology allows mounting directly on a duct wall with the top port exposed to the airstream, eliminating external reference plumbing. The 5-pin M-PAC surface-mount package supports automated PCB assembly, reducing manufacturing cost for high-volume HVAC controller production.

⚡

Industrial Process Control Loops

The MPXM2102GS supports industrial process control loops that monitor low-pressure fluid or gas lines, such as cleanroom positive-pressure maintenance, gas analyzer sample handling, and low-head pump monitoring. The piezoresistive silicon technology provides fast response time and mechanical robustness suited to industrial environments. Its single monolithic diaphragm with laser-trimmed thin-film resistor network delivers repeatable span and offset calibration part-to-part, which simplifies system calibration procedures. The M-PAC package with top tube port allows direct insertion into 1/8 inch pneumatic tubing without adapters. Combined with an industrial-grade instrumentation amplifier and isolated 4-20 mA transmitter, the MPXM2102GS forms a complete pressure-monitoring channel.

📱

Portable Altimeter & Wearable Devices

The MPXM2102GS is suitable for portable altimeters, fitness wearables, and handheld GPS units that report elevation gain to outdoor users. The 0 to 100 kPa range covers all realistic altitudes, and the small M-PAC surface-mount package fits thin wearable enclosures. The piezoresistive silicon sensor consumes power only during measurement and supports duty-cycled operation to extend battery life, which is critical for wearables that may run for weeks on a single coin cell. The on-chip temperature compensation maintains accuracy as the device moves between sunny and shaded conditions during hiking or climbing. The vented-gauge topology through the top port means the device reads atmospheric pressure directly without external sealing considerations.

🚗

Automotive Manifold & MAP Sensing Reference

Although the MPXM2102GS is not AEC-Q100 qualified, it serves well as a low-cost development reference for manifold absolute pressure (MAP) sensor design in non-production automotive applications and engineering test fixtures. The 100 kPa range covers atmospheric and light-boost manifold pressures; the on-chip temperature compensation handles under-hood thermal cycling during prototype validation. The piezoresistive silicon topology matches the operating principle used in production MAP sensors, allowing engineers to develop and validate signal-chain and calibration algorithms before porting to qualified parts. The 5-pin M-PAC package with top port is similar in form factor to many production MAP sensor packages, easing PCB layout reuse between prototype and final designs.

Recommended Products Summary

INA333 Low-power instrumentation amplifier for millivolt-level output Used in: Barometric Pressure & Altitude Sensing ADS1115 16-bit ADC for digitizing amplified pressure signal Used in: Barometric Pressure & Altitude Sensing AD620 Low-noise instrumentation amplifier for medical signal chain Used in: Medical Spirometry & Respiratory Monitoring MAX11209 20-bit precision ADC for high-resolution pressure digitizing Used in: Medical Spirometry & Respiratory Monitoring MCP3421 18-bit ADC for slow-precision HVAC pressure channels Used in: HVAC Differential Pressure Sensing XTR105 4-20 mA current-loop transmitter for industrial HVAC Used in: HVAC Differential Pressure Sensing INA128 Industrial-grade instrumentation amplifier Used in: Industrial Process Control Loops XTR110 Voltage-to-current converter for 4-20 mA loop output Used in: Industrial Process Control Loops MAX31760 Precision fan-speed controller (companion thermal sensor in wearables) Used in: Portable Altimeter & Wearable Devices TLV333 Zero-drift op-amp for low-power amplification Used in: Portable Altimeter & Wearable Devices MPX4100A NXP Semiconductors Used in: Automotive Manifold & MAP Sensing Reference MC33812 Engine management companion IC for signal conditioning Used in: Automotive Manifold & MAP Sensing Reference
What is the operating pressure range of the MPXM2102GS?
The MPXM2102GS measures from 0 kPa to 100 kPa (0 to 14.5 PSI) in a vented-gauge configuration. According to NXP product information, this range covers standard atmospheric-pressure applications including barometric measurement, HVAC duct pressure, and medical spirometry where measurement versus ambient pressure is required.
What is the output voltage of the MPXM2102GS at full-scale pressure?
The MPXM2102GS produces 0 mV to 40 mV output at 10 V excitation when pressure is swept across the 0 to 100 kPa range. This millivolt-level signal typically requires an external instrumentation amplifier (such as INA128 or AD620) to drive an ADC input range or 4-20 mA loop, per the NXP MPX2102 datasheet.
Is the MPXM2102GS still in production?
The MPXM2102GS is listed as End of Life on the NXP product information page. Customers needing long-term supply should evaluate active NXP replacements or consider the MPXM2202 series for higher-pressure designs; existing inventory remains available through authorized distributors while stocks last.
What is the difference between MPXM2102GS and MPXM2202GS?
The MPXM2102GS measures 0 to 100 kPa (14.5 PSI) while the MPXM2202GS measures 0 to 200 kPa (29 PSI). Both share the same 5-pin M-PAC (MPAK-4) package and piezoresistive silicon topology with on-chip temperature compensation, making the MPXM2202GS a viable upgrade for higher-pressure ranges, per cross-reference data.
Where can I buy the MPXM2102GS today?
The MPXM2102GS can be purchased from authorized distributors including DigiKey, Mouser, and Octopart-listed suppliers as of 2026-10-15. Because the part is EOL, stock is limited and pricing may fluctuate; we recommend requesting quotes from multiple distributors to confirm availability and lead time before placing volume orders.
What is the price of the MPXM2102GS in production quantities?
The MPXM2102GS unit price ranges approximately $4.35 at 1000-piece quantity to $8.95 at single-piece quantity as of 2026-10-15. EOL status typically tightens supply and increases price volatility; for budget-sensitive designs consider active NXP pressure sensors or qualified alternates such as the MPXM2202 family.
What is the lead time for MPXM2102GS orders?
Lead time for MPXM2102GS orders depends on distributor stock and is typically 4-12 weeks given EOL status as of 2026-10-15. We recommend contacting authorized NXP distributors directly for current lead-time quotes; long-term supply contracts may be required for production-bound designs given the part's End-of-Life classification.
What package does the MPXM2102GS use?
The MPXM2102GS uses a 5-pin M-PAC (MPAK-4) surface-mount module with a top-mounted tube port measuring 0.12 inches (2.97 mm) in diameter. This package style is part of the broader MPX sensor family and shares pinout compatibility with several other MPX2000-series devices, simplifying PCB reuse.
What can replace the MPXM2102GS in an existing design?
Drop-in alternatives for the MPXM2102GS include the same-family MPXM2102AST1 (tray packaging variant) and the MPXM2202GS (same package, 200 kPa range). For a true same-package, same-parameter alternative, contact NXP for their recommended replacement or consider Honeywell NCP series pressure sensors with equivalent M-PAC footprints.
What is the best NXP equivalent for the MPXM2102GS?
The best NXP equivalent for the MPXM2102GS is the MPXM2202GS, which shares the same 5-pin M-PAC (MPAK-4) package and piezoresistive topology but offers a higher 200 kPa (29 PSI) range. For exact 100 kPa replacement within the same family, the MPXM2102AST1 (tray-pack variant) is the closest drop-in choice.
Where can I download the MPXM2102GS datasheet PDF?
The MPXM2102GS datasheet PDF is available on the NXP product page at https://www.nxp.com/part/MPXM2102GS, and historical copies are hosted on alldatasheet.com and digchip.org. The datasheet covers the full MPX2102/MPXV2102G/MPXM2102 series specifications including electrical characteristics and application circuits.
What is the pinout of the MPXM2102GS?
The MPXM2102GS uses the standard 5-pin M-PAC (MPAK-4) pinout: pins 1-4 carry Vout+, Vout-, VS+, GND respectively, with pin 5 (and the tab) as the tube port reference. The exact pin assignment should be cross-checked against the NXP datasheet, as several MPX-series variants use slightly different ordering.
Does the MPXM2102GS require temperature compensation?
The MPXM2102GS includes on-chip temperature compensation via laser-trimmed thin-film resistors integrated with the silicon strain gauge network. This built-in compensation eliminates the need for external temperature-correction circuitry in most applications; however, system-level drift compensation may still be required for high-precision instrumentation per the NXP datasheet.
What supply voltage does the MPXM2102GS require?
The MPXM2102GS operates from a 10 V typical excitation supply with a 16 V absolute maximum per the MPX2102 datasheet. A stable, low-noise voltage source is critical because the sensor's output is ratiometric to the supply; ripple on VS directly translates to output error and degraded measurement accuracy.
What are the key specifications of the MPXM2102GS that engineers should know?
The MPXM2102GS delivers 0 mV to 40 mV output at 10 V excitation across 0 to 100 kPa (14.5 PSI) vented-gauge pressure, on-chip temperature compensation, monolithic silicon diaphragm, and a 5-pin M-PAC (MPAK-4) surface-mount package. Engineers should plan for an external instrumentation amplifier, 10 V regulated supply, and PCB layout that keeps the vent port unobstructed.

Engineering reference data for MPXM2102GS — comparison, design guidance, and compliance information.

Selection Guide

Choose the MPXM2102GS for a 100 kPa vented-gauge pressure measurement in a compact surface-mount form factor with on-chip temperature compensation, especially in medical, HVAC, and barometric sensing designs where the silicon piezoresistive technology and integrated calibration provide a low-BOM front end. Choose the MPXM2102AST1 (tray packaging) for the closest same-parameter drop-in if you need reel packaging or are qualifying alternate suppliers within the same NXP family. Choose the MPXM2202GS for higher-pressure designs up to 200 kPa (29 PSI) using the same M-PAC package and pinout, or the MPXM2202AS if an axial strain port geometry is required for your mechanical assembly. Because all listed parts are EOL, production designs should evaluate NXP's recommended replacements and qualify them before committing to volume orders.

Comparison with Alternatives

Parameter This Product MPXM2102AST1 MPXM2102GST1 MPXM2202GS MPXM2202GST1 MPXM2202AS
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package MPAK-4 (5-SMD Module) MPAK-4 (5-SMD Module) - same MPAK-4 (5-SMD Module) - same MPAK-4 (5-SMD Module) - same MPAK-4 (5-SMD Module) - same MPAK-4 (5-SMD Module) - same
Pressure Range 0 to 100 kPa (14.5 PSI) 0 to 100 kPa (14.5 PSI) 0 to 100 kPa (14.5 PSI) 0 to 200 kPa (29 PSI) 0 to 200 kPa (29 PSI) 0 to 200 kPa (29 PSI)
Output Voltage @ 10V 0 to 40 mV 0 to 40 mV 0 to 40 mV 0 to 40 mV (over 200 kPa) 0 to 40 mV (over 200 kPa) 0 to 40 mV (over 200 kPa)
Technology Piezoresistive silicon Piezoresistive silicon Piezoresistive silicon Piezoresistive silicon Piezoresistive silicon Piezoresistive silicon
Temperature Compensation On-chip (laser-trimmed) On-chip (laser-trimmed) On-chip (laser-trimmed) On-chip (laser-trimmed) On-chip (laser-trimmed) On-chip (laser-trimmed)
Operating Temperature -40 C to +125 C -40 C to +125 C -40 C to +125 C -40 C to +125 C -40 C to +125 C -40 C to +125 C
Lifecycle Status Obsolete (EOL) Obsolete (EOL) Obsolete (EOL) Obsolete (EOL) Obsolete (EOL) Obsolete (EOL)

Key Differentiators

  • On-chip temperature compensation with laser-trimmed calibration (vs Honeywell 26PC series pressure sensors)
  • M-PAC (MPAK-4) surface-mount package with top tube port (vs Through-hole MPX series pressure sensors)
  • Wide operating temperature range -40 C to +125 C (vs Industrial pressure sensors with 0 to +70 C rating)

Design Notes

The MPXM2102GS output is a differential millivolt-level signal (0-40 mV at 10 V excitation) that is highly susceptible to common-mode noise and ground loops. Use an instrumentation amplifier such as INA128, AD620, or INA333 with high common-mode rejection ratio (CMRR > 80 dB at 60 Hz) located within 10 cm of the sensor to capture the signal before it is corrupted. Twisted-pair wiring from the sensor to the amplifier further reduces EMI pickup; a driven shield or guard trace around the pair rejects capacitive coupling from adjacent high-voltage lines.

Provide a low-noise, well-regulated 10 V excitation supply to the MPXM2102GS. The sensor output is ratiometric to the excitation voltage: a 1% ripple on VS translates directly to a 1% error in the pressure reading. A linear regulator such as LM317 or a low-ripple DC-DC followed by an LC pi-filter is recommended; avoid feeding the sensor from the same switching regulator that powers digital logic. Decouple VS with a 100 nF ceramic capacitor placed within 5 mm of the sensor supply pin.

Do not apply pressure exceeding the rated 100 kPa range to the MPXM2102GS; the silicon diaphragm can crack or permanently deform, causing span and offset errors that calibration cannot recover. Do not block the vented-gauge reference port - it must remain open to ambient atmosphere or the device will read incorrect pressure. Do not use the sensor in condensing or corrosive media; the top tube port has no ingress protection and moisture ingress will damage the strain gauge network.

Mount the MPXM2102GS with the top tube port unobstructed and accessible to the pressure source. Leave at least 5 mm of clearance around the port for tubing connections; avoid placing tall components nearby that would interfere with pneumatic fittings. Route the analog signal traces as a differential pair with ground plane underneath to maintain signal integrity, and place the instrumentation amplifier within 10 cm of the sensor to minimize trace length and noise pickup.

Compliance Information

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Qualified
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

Lifecycle is End-of-Life per NXP product information page as of 2026-10-15. RoHS, REACH, lead-free, and halogen-free status not explicitly stated in retrieved web data and marked 'unknown'. Part is not AEC-Q100 qualified; not suitable for production automotive safety-critical applications.

Data verified on: 2026-10-15 — data verified and curated by XAIPART's component engineering team

Related Searches

MPXM2102GS MPXM2102GS datasheet NXP MPXM2102GS pressure sensor 100 kPa vented gauge pressure sensor M-PAC MPAK-4 pressure sensor piezoresistive silicon pressure transducer MPXM2102GS barometric altitude sensing MPXM2102GS medical spirometer MPXM2102GS HVAC differential pressure MPXM2102GS vs MPXM2202GS MPXM2102GS replacement EOL buy MPXM2102GS online MPXM2102GS price distributor what is the pressure range of MPXM2102GS MPXM2102GS pinout M-PAC

Related Components & Terms

NXP Semiconductors MPXM2102GS MPXM2102AST1 MPXM2102GST1 MPXM2202GS MPXM2202GST1 MPXM2202AS piezoresistive pressure sensor vented gauge pressure sensor silicon strain gauge MEMS pressure sensor M-PAC MPAK-4 package 5-SMD module on-chip temperature compensation laser-trimmed resistor barometric pressure altitude sensing spirometer HVAC differential pressure industrial process control 10 V excitation supply 0 to 100 kPa instrumentation amplifier
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details