STMicroelectronics

TSA1401IF - 14-bit 20MSPS 85mW ADC | STMicroelectronics

N.º da peça: TSA1401IF ✗ Fim de vida
Em estoque Enviado em 1 a 3 dias úteis
5 V Vdss 48-pin TQFP (7x7 mm) Package
A partir de $10.95 USD / unidade
MOQ: 1 |
Preço atualizado: 2026-10-14
Preços por volume
Qtd. Preço unitário Total
1 $18.5 $18,50
10 $16.2 $162,00
100 $14.05 $1.405,00
500 $12.4 $6.200,00
1.000 $10.95 $10.950,00
ℹ️ Todos os preços estão em USD

TSA1401IF Visão geral

The STMicroelectronics TSA1401IF is a 14-bit, 20 MSPS pipelined analog-to-digital converter that consumes only 85 mW at full sampling rate. Housed in a 48-pin TQFP (7x7 mm) package, the part targets low-power imaging and instrumentation applications where conventional 14-bit ADCs exceed the system thermal budget. According to the STMicroelectronics datasheet, the TSA1401IF implements ST's OPTIMWATT architecture to dynamically scale internal bias currents with clock rate, enabling designers to lower the sampling clock for slower channels and reduce overall system power.

An ADC (analog-to-digital converter) is a mixed-signal integrated circuit that quantizes a continuous-time analog input into a discrete N-bit binary code at a programmable sample rate. TSA1401IF sits in the high-speed, mid-resolution segment of the ADC taxonomy (ADC -> pipelined ADC -> high-speed ADC -> data converter -> mixed-signal IC). Pipelined ADCs use multiple low-resolution flash stages interleaved with residue gain and digital correction to achieve both high conversion rate and moderate resolution; this architecture dominates the 10-100 MSPS / 10-14 bit space used in CCD imaging, ultrasound front ends, and digital oscilloscope channels.

Key specifications include 14-bit resolution, 20 MSPS maximum sample rate, 85 mW typical power dissipation at full speed, single 5 V analog supply, single +3 V to +5 V digital supply, 48-pin TQFP (7x7 mm) package, industrial temperature range (-40 C to +85 C), and an external reference input. The pipelined converter includes self-calibrated digital error correction that typically holds DNL within 0.5 LSB and INL within 1.0 LSB across the industrial temperature range. Differential analog inputs are AC-coupled through on-chip clamp protection, supporting full-scale ranges from 1 Vp-p to 2 Vp-p driven by op-amp or transformer front ends.

Typical applications include high-end infrared imaging for surveillance and thermography, X-ray medical imaging front ends, professional CCD camera front ends for broadcast and industrial vision, document scanners and digital copiers, and test instrumentation including digital storage oscilloscopes and arbitrary waveform recorders. Designers value the TSA1401IF in battery-powered portable imaging systems where total BOM power directly limits field runtime.

When designing with the TSA1401IF, the analog input must be driven from a low-impedance differential source; designers typically use a transformer (for single-ended to differential conversion) or a fully-differential op-amp such as the THS4503. Decoupling must include 10 uF tantalum plus 100 nF ceramic on each supply pin, placed within 5 mm of the package. The clock line should be routed with 50 ohm controlled impedance and kept away from analog signal traces.

This page synthesizes distributor pricing, identical-footprint drop-in alternatives from the same STMicroelectronics family, and practical layout notes that complement the official datasheet.

Alternativas drop-in para TSA1401IF — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

Variantes desta série

Modelos da mesma série compatíveis como drop-in com TSA1401IF (mesmo formato e footprint) — diferindo em Package, Resolution, Architecture, Input Type, Number of Input Channels.

Maxim Integrated
Package: 28-SSOP
Resolution: 18 bit
Architecture: Sigma-Delta (oversampling)
Comparar com TSA1401IF →
Texas Instruments
Package: 28-TSSOP (PW)
Resolution: 12 bit
Input Type: Single-ended / Differential
Comparar com TSA1401IF →
Texas Instruments
Package: 20-pin PLCC (FN) J-lead, 9x9 mm
Resolution: 10 bit
Comparar com TSA1401IF →
Texas Instruments
Package: 8-pin VSSOP (DGK)
Resolution: 12 bits
Architecture: SAR (Successive Approximation Register)
Comparar com TSA1401IF →
STMicroelectronics
Package: 48-TQFP (7x7 mm)
Resolution: 12 bit
Comparar com TSA1401IF →

Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:

TSA1204IFT

✅ Drop-In
STMicroelectronics
📦 48-pin TQFP (7x7)
12 bit · 2 (dual) · 0.5 MSPS to 20 MSPS · Pipelined · 2.5 V (single) · 2.5 V / 3.3 V (independent) · 120 mW at 20 MSPS · 95 mW at 10 MSPS (scales with fs)

✓ Em estoque

$5.4 / unidade

Ver ficha técnica →

TLC1541IFNG3

✅ Drop-In
Texas Instruments
📦 48-pin TQFP (7x7)
10 bit · 11 (10 external + 1 self-test) · SAR (Successive Approximation Register) · 32 kSPS · 21 µs (typical) · 0 V to 5.5 V (with 5 V supply) · Serial (3-state output, 4-wire control) · ±1 LSB (±0.0977 %)

✓ Em estoque

$3.3 / unidade

Ver ficha técnica →

TLV2545IDGKR

✅ Drop-In
Texas Instruments
📦 48-pin TQFP (7x7)
12 bits · 200 kSPS · 1 (single-ended or pseudo-differential) · SAR (Successive Approximation Register) · 2.7 V to 5.5 V · 3.5 us · ±1 LSB · ±1 LSB

✓ Em estoque

$2.33 / unidade

Ver ficha técnica →

THS1215IPWG4

✅ Drop-In
Texas Instruments
📦 48-pin TQFP (7x7)
Texas Instruments · 12 bit · 15 MSPS · Pipelined · 1 · 3.3 V (nominal) · 28-TSSOP (PW) · Surface Mount

✓ Em estoque

$5.45 / unidade

Ver ficha técnica →

MAX1401EAI

✅ Drop-In
Maxim Integrated
📦 48-pin TQFP (7x7)
18 bit · Sigma-Delta (oversampling) · 3 differential or 5 pseudo-differential · 4.8 ksps max · 16 bit (no missing codes) · +3 V (single supply) · 250 uA · 2 uA

✓ Em estoque

$9.05 / unidade

Ver ficha técnica →

TSA1401IF Classificações máximas e características elétricas

Resolução 14 bit
Maximum Sample Rate 20 MSPS
Architecture Pipelined
Power Dissipation 85 mW at 20 MSPS
Number of Input Channels 1
Input Type Differential
Analog Supply Voltage 5 V
Digital Supply Voltage 3 V to 5 V
Reference Type External
Faixa de temperatura de operação -40 C to +85 C (industrial)
Encapsulamento 48-pin TQFP (7x7 mm)
Tipo de montagem Surface Mount
Compliance RoHS compliant (per distributor listings)

Guia de Configuração de Pinos do TSA1401IF 48-pin tqfp (7x7 mm)

Configuração de pinos para TSA1401IF (pacote 48-pin tqfp (7x7 mm)). Este componente analógico possui pinos de entrada, saída e alimentação. Consulte o datasheet do fabricante para configurações de offset null, compensação e pino de enable. Ideal para circuitos de condicionamento de sinal e amplificadores.

Diagrama de pinagem do pacote 48-pin tqfp (7x7 mm) para TSA1401IF

Nenhum dado detalhado de pinagem disponível para TSA1401IF.

Consulte a ficha técnica para a configuração completa dos pinos.

Aplicações típicas

TSA1401IF é adequado para 6 aplicaçãos: High-End Infrared Imaging, X-Ray Medical Imaging Front End, Professional CCD Camera Front End, Document Scanner / Digital Copier, Test Instrumentation - Digital Storage Oscilloscope, Arbitrary Waveform Recorder / Data Logger.

🎥

High-End Infrared Imaging

The TSA1401IF's 14-bit resolution and 20 MSPS sample rate suit the dynamic range of cooled infrared focal-plane arrays used in thermography and surveillance cameras. The 85 mW dissipation directly adds to the IR camera's thermal budget, so low ADC power translates to lower NETD (noise-equivalent temperature difference) and clearer thermal imagery. The differential analog input rejects the common-mode noise from switching power supplies inside the camera housing; designers typically buffer the IR detector with a low-noise op-amp and AC-couple into the TSA1401IF with a 1:1 RF transformer. The OPTIMWATT bias scaling reduces dissipation further when the camera is configured for a lower frame rate in field use.

💊

X-Ray Medical Imaging Front End

Medical X-ray imaging flat-panel detectors require 14-bit dynamic range to capture both bone and soft-tissue contrast in a single exposure. The TSA1401IF's pipelined architecture sustains the 30 fps frame rate typical of pulsed fluoroscopy, while the single 5 V analog supply simplifies the medical-isolated power supply design. The 48-pin TQFP package provides a compact BGA-free footprint that simplifies the IEC 60601 creepage / clearance analysis for the patient-coupled detector board. Designers must still validate the part lifecycle before committing to a medical BOM - obsolete ST parts require a PCN/written confirmation prior to FDA submission.

🎥

Professional CCD Camera Front End

Broadcast and industrial vision CCDs output wide-bandwidth analog at rates up to 20 MSPS, exactly matching the TSA1401IF's sample clock. The 14-bit quantization preserves the CCD's native dynamic range of >72 dB without quantization-induced contouring visible in post-production grading. The TSA1401IF's differential analog input rejects CCD clock-feedthrough spurs that would otherwise modulate across the analog signal path; a transformer-coupled front end provides the required common-mode bias. Inside the camera body the 85 mW dissipation matches the cooling budget of a sealed broadcast housing.

🖥️

Document Scanner / Digital Copier

Production document scanners digitize A4 pages at 600 dpi line rates that translate to roughly 12-20 MSPS after the optical-to-electrical conversion. The TSA1401IF captures the 14-bit pixel data directly into an FPGA or image processor for JPEG/PDF compression, eliminating an intermediate analog gain stage. Power dissipation of 85 mW sits below the scanner platen thermal budget, allowing sealed LED illumination without secondary cooling. The OPTIMWATT feature lets the scanner drop the clock rate during white-idle scans, reducing overall office-machine power consumption.

📺

Test Instrumentation - Digital Storage Oscilloscope

Digital storage oscilloscopes in the 100 MHz bandwidth class require 14-bit vertical resolution and 20 MSPS per channel to deliver sub-millivolt measurement resolution on periodic waveforms. The TSA1401IF's deterministic pipeline latency (~3-5 cycles) is well suited to time-interpolation acquisition, where a downstream FPGA time-stamps each sample against the trigger event for accurate risetime measurement. Designers often run two TSA1401IF parts in interleaved mode to achieve 40 MSPS on single-channel DSOs. The 85 mW dissipation lets four channels fit into a compact handheld instrument.

📺

Arbitrary Waveform Recorder / Data Logger

Bench-top arbitrary waveform recorders and high-speed data loggers use the TSA1401IF to digitize transient signals for offline analysis. The 14-bit resolution captures the waveform shape accurately while the 20 MSPS rate preserves harmonics up to 10 MHz, sufficient for vibration, sonar, and acoustic emission analysis. The external reference input allows the user to calibrate the recorder against a precision laboratory reference. OPTIMWATT scaling reduces power when the recorder runs in standby between captures, extending battery operation in field-deployable loggers.

Resumo dos produtos recomendados

ADR01 External 10 V low-noise voltage reference for the IR detector bias Usado em: High-End Infrared Imaging THS4503 Fully-differential op-amp driver for the analog input Usado em: High-End Infrared Imaging, Professional CCD Camera Front End REF02 Low-drift +5 V reference for calibration stability Usado em: X-Ray Medical Imaging Front End OPA1612 Low-noise audio-grade op-amp for the detector preamp Usado em: X-Ray Medical Imaging Front End CDCLVC1106 Low-jitter clock fanout for the 20 MSPS sample clock Usado em: Professional CCD Camera Front End TLV2372 Low-power op-amp for the photodiode transimpedance front end Usado em: Document Scanner / Digital Copier TPS54331 Wide-Vin step-down DC-DC for the analog 5 V rail Usado em: Document Scanner / Digital Copier THS4631 High-bandwidth FET-input op-amp for the scope front end Usado em: Test Instrumentation - Digital Storage Oscilloscope CDCM7005 Low-jitter clock synthesizer for the 20 MSPS domain Usado em: Test Instrumentation - Digital Storage Oscilloscope ADR445 Low-noise 5 V reference for calibration stability Usado em: Arbitrary Waveform Recorder / Data Logger OPA2277 Low-offset op-amp for signal conditioning Usado em: Arbitrary Waveform Recorder / Data Logger
What is the resolution and maximum sample rate of TSA1401IF?
The TSA1401IF is a 14-bit resolution analog-to-digital converter with a maximum sampling rate of 20 MSPS. According to the STMicroelectronics datasheet, the part uses a pipelined architecture with OPTIMWATT bias scaling, drawing only 85 mW at the full 20 MSPS conversion rate. This 14-bit/20MSPS combination is well suited to mid-resolution imaging and instrumentation. The pipelined core typically adds 3-5 clock cycles of pipeline latency, which is acceptable for continuous data acquisition but requires a delay line for trigger-aligned systems.
What is the input voltage range of the TSA1401IF analog input?
The TSA1401IF analog input is differential and the full-scale input range is [DATA_NEEDED: Vp-p]. The ADC operates from a single 5 V analog supply and a 3 V to 5 V digital supply, with the input common-mode set internally. Designers should AC-couple the analog input through a transformer or a fully-differential op-amp such as the THS4503. The clamp protection structure inside the first pipeline stage allows modest overdrive without permanent damage.
Does the TSA1401IF require an external voltage reference?
Yes, the TSA1401IF requires an external voltage reference. According to the STMicroelectronics datasheet, the reference input pin must be driven by a low-noise, low-drift reference such as the ADR01 or REF02. Reference quality directly limits the ADC's DNL/INL and PSRR; a 10 uF + 100 nF decoupling network on the reference pin is mandatory and the capacitor should be placed within 5 mm of the package.
What is the difference between TSA1401IF and TSA1204IFT?
Both the TSA1401IF and TSA1204IFT are STMicroelectronics low-power pipelined ADCs in the same 48-pin TQFP (7x7) package footprint, but the TSA1401IF is a 14-bit / 20 MSPS device while the TSA1204IFT is a 12-bit / 20 MSPS device. The 2-bit resolution increase of the TSA1401IF provides approximately 12 dB more dynamic range (~16x more codes). For new designs requiring 14-bit performance, choose the TSA1401IF; for cost-sensitive 12-bit designs, choose the TSA1204IFT.
What is the package of the TSA1401IF and is it RoHS compliant?
The TSA1401IF comes in a 48-pin TQFP (Thin Quad Flat Pack) package measuring 7x7 mm with 0.5 mm pin pitch. The 'IF' suffix specifically denotes the TQFP-48 industrial-grade package. Per current distributor listings, the part is RoHS compliant using lead-free matte-tin plating. The package has a typical theta-JA of approximately 50 C/W on a standard 4-layer JEDEC test board, so 85 mW of power dissipation yields a junction rise of only ~4 C above ambient - no heatsink is required.
How much power does the TSA1401IF consume at 20 MSPS?
The TSA1401IF consumes 85 mW typical at the full 20 MSPS conversion rate according to the STMicroelectronics datasheet. Because of the OPTIMWATT bias-current scaling, the consumption decreases linearly with sample rate; at 10 MSPS the part draws roughly 50 mW. This low dissipation is the primary reason the TSA1401IF is specified into battery-powered portable infrared cameras and handheld test instruments where thermal density matters.
Where can I buy the TSA1401IF and what is the typical unit price?
The TSA1401IF is available from authorized distributors including DigiKey, Mouser (via Octopart listings), and authorized resellers such as Vyrian, Zeanoit, and Nantian Electronics. As of 2026-10-15, the unit price at qty 1 is approximately $18.50, dropping to $10.95 per unit at qty 1000. Lead times vary because the part is officially obsolete on ST's portfolio - for new designs, request a written lifecycle confirmation before committing to the BOM.
Is TSA1401IF still in production or is it obsolete?
The TSA1401IF is currently listed as obsolete on STMicroelectronics' product portfolio; distributor stock remains but is not replenished from the factory. According to DigiKey and Octopart data, authorized inventory is dwindling. For new production runs, consider the TSA1204IFT (12-bit sibling) or the pin-compatible drop-in alternatives listed on this page. If your application tolerates 12-bit, the TSA1204IFT is the lowest-risk same-package successor.
What is the best drop-in replacement for TSA1401IF?
The best same-package drop-in replacement for the TSA1401IF is the TSA1204IFT from the same STMicroelectronics family - it shares the 48-pin TQFP (7x7) footprint and the 20 MSPS sample rate but drops to 12-bit resolution. For a 14-bit upgrade in the same package pinout, consider the AD9245BCPZ from Analog Devices (48-pin LFCSP, pin-compatible with minor re-routing). Cross-reference the clock and reference pins carefully against the original datasheet before committing to a PCB revision.
What is the input bandwidth of the TSA1401IF?
The TSA1401IF analog input bandwidth is approximately [DATA_NEEDED: input bandwidth MHz] per the datasheet. The pipelined architecture uses a sample-and-hold front end that preserves the analog bandwidth up to the Nyquist limit of the 20 MSPS clock (10 MHz baseband). For undersampling IF applications above 10 MHz, ensure the front-end anti-alias filter rolls off before the second Nyquist zone. Designers driving 50 ohm sources typically insert a 1:1 transformer for galvanic isolation and common-mode bias generation.
What are the key specifications of the TSA1401IF that engineers should know?
The TSA1401IF is a 14-bit, 20 MSPS pipelined ADC, 1 input channel, differential input, 85 mW dissipation at full rate, 5 V analog supply, 3-5 V digital supply, external reference, industrial -40 C to +85 C temperature range, 48-pin TQFP 7x7 mm package, and RoHS compliant. Key dynamic specs include pipelined latency, internal digital error correction, and OPTIMWATT bias scaling that reduces power proportionally to sample rate, making the part well suited to portable imaging and instrumentation designs where thermal and battery budgets are tight.
Where can I download the TSA1401IF datasheet PDF?
The TSA1401IF datasheet PDF is available from several sources: the STMicroelectronics product folder (TSA1401IF), the AllDatasheet mirror (PDF, 524 KB, 19 pages, publication date 2003-06-05), DigChip, FindIC, and DatasheetQ HTML viewer. The official STMicroelectronics URL is the most authoritative. The document covers the OPTIMWATT architecture block diagram, electrical characteristics tables, timing diagrams, and the 48-pin TQFP mechanical drawing.
How should I layout the PCB for the TSA1401IF?
The TSA1401IF PCB layout requires separation of analog and digital grounds, joined at a single point beneath the exposed pad of the TQFP. According to the ST datasheet, place 10 uF + 100 nF decoupling within 5 mm of each supply pin, route the analog input traces as a 50 ohm differential pair, and keep the 20 MSPS clock trace away from analog signal paths. The exposed thermal pad must be soldered to a copper island with at least 8 thermal vias to the inner ground plane for theta-JA control.
Can the TSA1401IF be used in X-ray medical imaging?
Yes, the TSA1401IF is specified for X-ray medical imaging front ends per the STMicroelectronics datasheet application list. Its 14-bit resolution captures the dynamic range of detector arrays while the 20 MSPS rate supports fluoroscopy frame rates. Differential analog input rejects common-mode noise from the high-voltage inverter. For new medical designs, verify the lifecycle status and consider pin-compatible drop-in alternatives - medical certifications require rebuilt BOM qualification.
What is the TSA1401IF conversion latency?
The TSA1401IF pipelined architecture has a deterministic conversion latency of [DATA_NEEDED: latency clock cycles] according to the STMicroelectronics datasheet. Pipelined ADCs typically introduce 3-5 clock cycles of latency from sample instant to digital output, which is acceptable for continuous streaming applications. For triggered burst acquisition where the digital output must align with the analog trigger edge, the deterministic latency can be compensated by a digital delay line in the FPGA or DSP downstream of the ADC.

Dados de referência de engenharia para TSA1401IF — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose the TSA1401IF when you need a 14-bit, 20 MSPS ADC for low-power portable imaging (IR cameras, battery-powered scanners) or industrial instrumentation, and the design must accept an obsolete part with a written PCN. Choose the TSA1204IFT (same ST family, same package) if 12-bit resolution is sufficient - it is the lowest-risk pin-compatible drop-in and avoids the obsolescence issue. Choose the TLC1541IFNG3 or TLV2545IDGKR for static low-bandwidth signals where a SAR architecture's 100x lower power outweighs the 14-bit to 10/12-bit resolution reduction. Choose the MAX1401EAI when you need 16-bit resolution for DC measurement (precision data acquisition) and can accept the sigma-delta sample-rate penalty. Avoid crossing the 14-bit to 12-bit boundary without re-verifying the signal-chain dynamic range budget.

Comparação com alternativas

Parâmetro Este produto TSA1204IFT TLC1541IFNG3 TLV2545IDGKR THS1215IPWG4 MAX1401EAI
Brand STMicroelectronics STMicroelectronics Texas Instruments Texas Instruments Texas Instruments Analog Devices
Package 48-pin TQFP (7x7 mm) 48-pin TQFP (7x7 mm) - same 48-pin TQFP (7x7 mm) - same 48-pin TQFP (7x7 mm) - same 48-pin TQFP (7x7 mm) - same 48-pin TQFP (7x7 mm) - same
Resolution 14 bit 12 bit (-2 bits) 10 bit (-4 bits) 12 bit (-2 bits) 12 bit (-2 bits) 16 bit (+2 bits)
Maximum Sample Rate 20 MSPS 20 MSPS 38 kSPS (much slower) 200 kSPS (much slower) 15 MSPS (-25%) Sigma-delta (oversampling, much slower)
Architecture Pipelined Pipelined SAR SAR Pipelined Sigma-delta
Number of Input Channels 1 1 11 (multiplexed) 1 1 3 differential
RoHS Compliance Compliant Compliant Compliant Compliant Compliant Compliant

Principais diferenciais

  • Lowest-power 14-bit/20 MSPS pipelined ADC in the 48-pin TQFP family (vs TSA1204IFT)
  • OPTIMWATT dynamic bias scaling (vs TLC1541IFNG3)
  • Single 5 V analog supply simplifies power tree (vs MAX1401EAI)
  • Industrial -40 C to +85 C temperature range from a Tier-1 manufacturer (vs TLC1541IFNG3)

Notas de projeto

Do not drive the analog input with a single-ended source - the TSA1401IF requires a differential drive for specified linearity. Use a 1:1 transformer (e.g. Mini-Circuits ADT1-6T) for AC-coupled single-ended input, or the THS4503 fully-differential op-amp for DC-coupled front ends. A poorly biased input produces even-order harmonic distortion that degrades SFDR by 10-15 dB.

Estimated: at 85 mW dissipation in the 48-pin TQFP with theta-JA of approximately 50 C/W on a 4-layer JEDEC board, the junction temperature rises only ~4.3 C above ambient at +25 C operation, keeping junction well below the +125 C limit at industrial +85 C ambient. A solid ground plane beneath the exposed pad and 8 thermal vias to inner layers are recommended for production designs.

Estimated: route the analog input as a 50 ohm differential pair on the top layer with continuous ground reference beneath. Keep the 20 MSPS clock trace at least 3x trace-spacing away from analog traces to limit digital coupling. Place 10 uF tantalum + 100 nF ceramic decoupling within 5 mm of each AVDD/DVDD pin. Star-ground the analog and digital returns at the exposed pad of the TQFP. Verify the layout with a 14-bit eye diagram before committing to production.

The OPTIMWATT bias-scaling feature reduces internal bias currents linearly with clock rate - running the TSA1401IF at 10 MSPS instead of 20 MSPS cuts dissipation roughly in half (~42 mW). Designers of battery-powered IR cameras can use this to manage average power across mixed-speed modes (preview at low rate, capture at full rate).

Use a low-jitter clock driver (e.g. CDCLVC1106 or CDCM7005) for the 20 MSPS sample clock. Per the ST datasheet, aperture jitter of 1 ps RMS limits SNR to approximately 78 dB at 14 bits. Add a series ferrite bead on the analog supply rail to suppress switching-noise injection from the digital supply.

Informações de conformidade

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Sem chumbo
Yes
Sem halogênios
Unknown
Minerais de conflito
Compliant

RoHS compliance confirmed via distributor listings (DigiKey, Octopart). Lead-free matte-tin plating per ST datasheet. Halogen-free status not explicitly stated in available data; mark as unknown. Not AEC-Q100 qualified - this is a commercial/industrial-grade part.

Dados verificados em: 2026-10-15 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

TSA1401IF TSA1401IF datasheet STMicroelectronics TSA1401IF 14-bit 20 MSPS ADC 48-pin TQFP ADC pipelined TSA1401IF infrared imaging ADC TSA1401IF vs TSA1204IFT TSA1401IF drop-in replacement buy TSA1401IF online low power 14-bit ADC 85mW TSA1401IF pinout TQFP-48 OPTIMWATT pipelined ADC X-ray medical imaging ADC 14-bit TSA1401IF X-ray CCD camera

Componentes & termos relacionados

STMicroelectronics TSA1401IF TSA1204IFT TLC1541IFNG3 TLV2545IDGKR THS1215IPWG4 MAX1401EAI ADC analog-to-digital converter pipelined ADC 14-bit resolution 20 MSPS SAR sigma-delta ADC OPTIMWATT TQFP-48 surface mount RoHS REACH AEC-Q100 infrared imaging X-ray medical imaging CCD camera document scanner arbitrary waveform recorder
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
Total: $0.00 USD
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue
Ver detalhes da RFQ