XRD87L99AIQ-F - 10-Bit 2 MSPS 8-Ch MUX ADC | MaxLinear
N.º da peça: XRD87L99AIQ-F ✗ Fim de vida| Qtd. | Preço unitário | Total |
|---|---|---|
| 1 | $7.2 | $7,20 |
| 10 | $6.48 | $64,80 |
| 100 | $5.76 | $576,00 |
| 500 | $5.04 | $2.520,00 |
| 1.000 | $4.32 | $4.320,00 |
XRD87L99AIQ-F Visão geral
An ADC (analog-to-digital converter) is a mixed-signal integrated circuit that samples continuous analog voltages into a parallel digital word at a defined clock rate. ADCs sit within the broader hierarchy of data acquisition ICs -> data converters -> mixed-signal ICs -> integrated circuits, and they are the critical bridge between analog sensors and digital processors. Multi-channel, low-power ADCs like the XRD87L99AIQ-F are typically used to digitize several sensors with one converter, reducing board area, BOM cost, and software overhead in embedded designs.
Key features of the XRD87L99AIQ-F include 10-bit resolution, an integrated 8-to-1 analog multiplexer with channel-address latches, a parallel microprocessor-compatible digital interface, an external reference input, and a hardware power-down pin. Its wide input range covers GND to VDD, which lets the device directly digitize rail-to-rail sensor outputs. The 44-QFP package is industry-standard and supports conventional surface-mount assembly.
Typical applications for the XRD87L99AIQ-F include multi-channel data acquisition systems, CCD signal processing chains in scanner and copier subsystems, portable and battery-powered instrumentation, industrial process monitoring, and embedded control boards that need to read several analog sensors at moderate speeds. In each case the device's low power dissipation, integrated mux, and parallel interface reduce both component count and software complexity.
Designers should remember that the XRD87L99AIQ-F is in EOL/last-time-buy status according to distributor lifecycle fields, so long-life designs should plan for a qualified replacement or place a last-time-buy order. Drive the analog inputs with low-impedance sources to keep the input settling error inside the 10-bit budget, and place the 0.1uF VDD decoupling capacitor within a few millimeters of the supply pin.
Alternativas drop-in para XRD87L99AIQ-F — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Variantes desta série
Modelos da mesma série compatíveis como drop-in com XRD87L99AIQ-F (mesmo formato e footprint) — diferindo em Package, Resolution, Input Type, Architecture, Number of Input Channels.
Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:
XRD87L99AIQ
✅ Drop-In ⚠️ Especificações não verificadas📋 Alternativa de referência (fora do catálogo)
MAX1285BCSA
✅ Drop-In✓ Em estoque
$5.4 / unidade
Ver ficha técnica →MAX1285BCSA-T
✅ Drop-In✓ Em estoque
$4.89 / unidade
Ver ficha técnica →MAX1285BESA
✅ Drop-In✓ Em estoque
$7.97 / unidade
Ver ficha técnica →TLC549CD
✅ Drop-In✓ Em estoque
$1.02 / unidade
Ver ficha técnica →XRD87L99AIQ-F Classificações máximas e características elétricas
| Resolução | 10 bits |
| Taxa de amostragem | 2 MSPS |
| Number of Input Channels | 8 (analog MUX) |
| Architecture | Successive Approximation |
| Data Interface | Parallel |
| Input Type | Single-Ended |
| Faixa de tensão de entrada | GND to VDD |
| Reference Type | External |
| Power Dissipation (Active, typ) | 24 mW |
| Power Dissipation (Power-Down, typ) | 0.1 mW |
| Number of ADC Converters | 1 |
| Sample-and-Hold | Internal (no external S/H required for inputs <100 kHz or CCD signals) |
| Temperatura de operação | -40C to +85C |
| Encapsulamento | 44-QFP |
| Tipo de montagem | Surface Mount |
| Packaging | Tray |
| Status | Obsolete / Last Time Buy |
Guia de Configuração de Pinos do XRD87L99AIQ-F 44-qfp
Configuração de pinos para XRD87L99AIQ-F (pacote 44-qfp). Este componente analógico possui pinos de entrada, saída e alimentação. Consulte o datasheet do fabricante para configurações de offset null, compensação e pino de enable. Ideal para circuitos de condicionamento de sinal e amplificadores.
Nenhum dado detalhado de pinagem disponível para XRD87L99AIQ-F.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
XRD87L99AIQ-F é adequado para 6 aplicaçãos: Multi-Channel Data Acquisition Systems, CCD Signal Processing in Scanners and Copiers, Portable and Battery-Powered Instrumentation, Industrial Process Monitoring, Embedded Control Boards with Multiple Sensors, Medical Monitoring Front Ends.
Multi-Channel Data Acquisition Systems
The XRD87L99AIQ-F's 8-to-1 analog input multiplexer lets a single ADC service up to eight sensors, which is ideal for multi-channel data acquisition front ends. At 2 MSPS, the converter can digitize up to eight channels sequentially at 250 kSPS each, well above typical 10 kHz transducer bandwidths. Its 24 mW active dissipation keeps the front end cool even in sealed enclosures. Place a 0.1uF decoupling capacitor near the VDD pin to keep digital switching noise out of the analog rail.
Recomendado
CCD Signal Processing in Scanners and Copiers
The XRD87L99AIQ-F datasheet explicitly states that no external sample-and-hold is required for CCD signals, making the part a natural fit for scanner, copier, and machine-vision front ends. The 2 MSPS throughput captures multi-megapixel CCD line rates, and the GND-to-VDD input range accommodates CCD output stages biased near the analog supply. Use an external precision reference (e.g. a low-drift bandgap) on the VHF pin to maximize 10-bit linearity.
Recomendado
Portable and Battery-Powered Instrumentation
Battery-powered instruments benefit from the XRD87L99AIQ-F's 24 mW active power and 0.1 mW power-down dissipation, which together extend runtime when conversions are bursty. The hardware power-down pin can be toggled between sample bursts, and the parallel interface lets low-cost MCUs read the conversion result in a single bus cycle. Designers should also enable the MCU's idle mode so the system quiescent current stays in the sub-milliamp range.
Recomendado
Industrial Process Monitoring
Industrial process monitoring typically reads 4-20 mA loops, thermocouples, and bridge sensors, all of which fit naturally into the XRD87L99AIQ-G's GND-to-VDD analog input range. The 8-channel MUX eliminates an external analog switch tree, and the -40C to +85C industrial operating range covers plant-floor environments. Pair the converter with op-amp signal conditioning and an external precision reference to achieve better than 10-bit absolute accuracy in noisy cabinets.
Recomendado
Embedded Control Boards with Multiple Sensors
Embedded control boards commonly need to monitor several analog sensors (temperature, pressure, light, current) from a single MCU, and the XRD87L99AIQ-F's 8-channel MUX addresses all of them from one converter. The parallel digital interface is compatible with most 8/16-bit MCU external memory buses, so no specialized peripheral is required. A 4-wire SPI-friendly variant is not offered, but the parallel bus allows direct DMA-style capture on microcontrollers that support it.
Recomendado
Medical Monitoring Front Ends
In low-power medical monitoring designs, the XRD87L99AIQ-F can digitize ECG, pulse oximetry, or temperature sensor signals across its eight analog inputs with 10-bit resolution adequate for trend logging. The 24 mW dissipation keeps thermal rise near the patient interface low, and the parallel output bus feeds directly into a microcontroller or DSP for waveform analysis. As with all medical designs, validate the full signal chain against IEC 60601-1 EMI/EMC limits before release.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para XRD87L99AIQ-F — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | XRD87L99AIQ | MAX1285BCSA | MAX1285BESA | TLC549CD |
|---|---|---|---|---|---|
| Package | 44-QFP | 44-QFP - same | 16-SOIC | 16-SOIC | 8-SOIC |
| Brand | MaxLinear (formerly Exar) | MaxLinear (formerly Exar) | Analog Devices (formerly Maxim) | Analog Devices (formerly Maxim) | Texas Instruments |
| Resolution | 10 bits | 10 bits | 12 bits | 12 bits | 10 bits |
| Input Channels | 8 (MUX) | 8 (MUX) | 8 (MUX) | 8 (MUX) | 1 |
| Data Interface | Parallel | Parallel | Serial/SPI | Serial/SPI | Serial/SPI |
| Operating Temperature | -40C to +85C | -40C to +85C | 0C to +70C (commercial) | -40C to +85C | 0C to +70C |
| Lifecycle Status | Obsolete (EOL) | Obsolete (EOL) | Active | Active | Active |
Principais diferenciais
- 8-channel MUX integrated on-die (vs TLC549CD)
- 2 MSPS throughput vs ~45 kSPS on legacy single-channel SARs (vs TLC549CD)
- Parallel digital bus for high-throughput MCU interfaces (vs MAX1285BCSA)
- Wide 44-QFP package simplifies hand prototyping (vs MAX1285BCSA)
Notas de projeto
The XRD87L99AIQ-F's 24 mW active dissipation at 2 MSPS is the headline low-power figure, but burst-mode designs should keep the device idle most of the time. Toggle the hardware power-down pin between conversions so that quiescent dissipation drops to 0.1 mW typical. Decouple VDD with a 0.1uF ceramic placed within a few millimeters of the supply pin to keep digital switching noise out of the analog rail.
Drive each analog input with a low-impedance source (<= 1 kohm) so that the internal sample capacitor settles within the 10-bit accuracy window before conversion. The datasheet's 'no external S/H required below 100 kHz' specification assumes such a source. For higher-frequency inputs, add a wideband op-amp buffer (e.g. AD8031 or equivalent) right at the AIN pin to preserve aperture accuracy.
Because the XRD87L99AIQ-F is marked Obsolete (EOL), do not design it into new production volumes without a last-time-buy plan. Place a sufficient last-time-buy order once the design is frozen, or redesign around a current-generation 8-channel SAR ADC in a smaller, lead-free package such as MAX1285BCSA (16-SOIC) or TLV2545 (MSOP-10) to avoid line-down risk later in the product lifecycle.
Route the parallel digital output bus away from the analog input traces and the VREF pin. Place a ground guard ring around the analog input bank and tie AGND and DGND together at a single star point near the ADC's ground pin. Use a solid analog ground pour under the 44-QFP and keep switching converters at least one inch away from the analog input traces.
Informações de conformidade
RoHS-compliant lead-free finish indicated by '-F' designation per MaxLinear/Exar part numbering. Halogen-free status not stated in distributor data and is marked unknown. Not AEC-Q100 qualified; intended for industrial/consumer designs.